You must properly place a disk unit within a system unit or expansion unit before you use the disk unit as the load source for an i5/OS® logical partition. The placement rules depend upon the server unit or expansion unit in which the load source is located and the I/O adapter (IOA) that controls the load source.
The load source disk for an i5/OS logical partition must be placed as follows.
| Server or expansion unit | IOA | Disk slot |
|---|---|---|
| 515 | Imbedded controller | P3-D2, P3-D3, P3-D4 |
| SCSI bus port 0 of Optional PCI storage IOA controlling P2 disk slots | P2-D2, P2-D3, P2-D4 | |
| 520 | Imbedded controller | P3-D2, P3-D3, P3-D4 |
| SCSI bus port 0 of Optional PCI storage IOA controlling P2 disk slots | P2-D2, P2-D3, P2-D4 | |
| 525 | Imbedded controller | P3-D2, P3-D3, P3-D4 |
| SCSI bus port 0 of Optional PCI storage IOA controlling P2 disk slots | P2-D2, P2-D3, P2-D4 | |
| 550 | Imbedded controller | P2-D2, P2-D3, P2-D4 |
| SCSI bus port 0 of Optional PCI storage IOA controlling P3 disk slots | P3-D2, P3-D3, P3-D4 | |
| 570 | Imbedded controller | P3-D4, P3-D5, P3-D6 |
| 595 | SCSI bus port 0 of any storage IOA to which a load source disk unit is connected in the base PCI-X expansion tower (9194) | D01, D02, D11, D12, D21, D22, D06, D07, D16, D17, D26, D27, D31, D32, D33, D34 of base PCI-X expansion tower (9194) |
| 5074 or 5079 | IOA controlling device board slot 3 | D31, D32, D33, D34 |
| IOA controlling device board slot 1 | D01, D02 | |
| IOA controlling device board slot 2 | D06, D07 | |
| 5094 or 5294 | SCSI bus port 0 of any storage IOA to which a load source disk unit is connected. | D01, D02, D11, D12, D21, D22, D06, D07, D16, D17, D26, D27, D31, D32, D33, D34 |
| 5095 | IOA controlling device board slot 1 | D01, D02, D03, D04 |
| IOA controlling device board slot 2 | D07, D08, D09, D10 | |
| 5786 or 5787 | SCSI bus port 0 of any storage IOA to which a load source disk unit is connected | P1-D1, P1-D2, P1-D3 can contain the load source only if slot C3 contains a single SCSI (506E) repeater card that is connected to port 0 on a SCSI I/O Adapter (IOA) in the system unit but is not connected to slot C2. P1-D7, P1-D8, P1-D9 can contain the load source only if the SCSI repeater card in slot C2 is connected to port 0 on a SCSI IOA in the system unit. P2-D1, P2-D2, P2-D3 can contain the load source only if slot C4 contains a single SCSI (506E) repeater card that is connected to port 0 on a SCSI IOA in the system unit but is not connected to slot C5. P2-D7, P2-D8, P2-D9 can contain the load source only if the SCSI repeater card in slot C4 is connected to port 0 on a SCSI IOA in the system unit. |
| 5790 or 5796 | SCSI bus port 0 of any storage IOA to which a load source disk unit in a 5786 or 5787 expansion unit is connected | P1-D1, P1-D2, P1-D3 can contain the load source only if slot C3 contains a single SCSI (506E) repeater card that is connected to port 0 on a SCSI I/O Adapter (IOA) in the 5790 expansion unit but is not connected to slot C2. P1-D7, P1-D8, P1-D9 can contain the load source only if the SCSI repeater card in slot C2 is connected to port 0 on a SCSI IOA in the 5790 expansion unit. P2-D1, P2-D2, P2-D3 can contain the load source only if slot C4 contains a single SCSI (506E) repeater card that is connected to port 0 on a SCSI IOA in the 5790 expansion unit but is not connected to slot C5. P2-D7, P2-D8, P2-D9 can contain the load source only if the SCSI repeater card in slot C4 is connected to port 0 on a SCSI IOA in the 5790 expansion unit. |
Read the following rules about load source placement for i5/OS logical partitions: