subscribe iconSubscribe to this information

Converting the loop number to NIC port location labels

Use the following table to convert the HSL/RIO loop number to NIC port location labels.

Note: If you are working on a 570, exchange the FRU on the correct unit (primary or secondary) by matching the serial number (if available in the FRU list on the serviceable event view) or by matching the loop number to the correct unit.
Note: To simplify this information, secondary units on the 570 server are numbered 1 through 3-secondary unit 1 being nearest to the primary unit and secondary unit 3 being furthest.
Model 5705/70 with secondary units
Table 1. Converting the loop number to NIC port location labels
Loop number (hex / dec) Model NIC's FRU position HSL port labels on system unit or processor tower
0684 / 1668 515,520, 525, 550, OpenPower® 720, 570, primary unit, 575 -P1 Internal
Node 0 on 590 or 595 -P2 Internal
Note: The normal loop status is OPEN because the internal links are not joined to form a loop.
0685 / 1669 515,520, 525 -P1 -P1-T3-P1-T4
550, OpenPower 720 -P1 -P1-T11-P1-T12
570 primary unit -P1 -P1-T8-P1-T9
575 -P1 -P1-T7-P1-T8
Node 0 on 590 or 595 -P2-C1 -P2-C1-T1-P2-C1-T2
0686 / 1670 550, OpenPower 720 -P1-C6 -P1-C6-T1-P1-C6-T2
570 primary unit -P1-C7 -P1-C7-T1-P1-C7-T2
Node 0 on 590 or 595 -P2 Internal
0687 / 1671 570 secondary unit 1 -P1 Internal (see note above)
Node 0 on 590 or 595 -P2-C3 -P2-C3-T1-P2-C3-T2
0688 / 1672 570 secondary unit 1 -P1 -P1-T8-P1-T9 (see note above)
Node 0 on 590 or 595 -P2-C5 -P2-C5-T1-P2-C5-T2
0689 / 1673 570 secondary unit 1 -P1-C7 -P1-C7-T1-P1-C7-T2 (see note above)
068A / 1674 570 secondary unit 2 -P1 Internal (see note above)
Node 0 on 590 or 595 -P2-C6 -P2-C6-T1-P2-C6-T2
068B / 1675 570 secondary unit 2 -P1 -P1-T8-P1-T9 (see note above)
068C / 1676 570 secondary unit 2 -P1-C7 -P1-C7-T1-P1-C7-T2 (see note above)
Node 0 on 590 or 595 -P2-C8 -P2-C8-T1-P2-C8-T2
068D / 1677 570 secondary unit 3 -P1 Internal (see note above)
068E / 1678 570 secondary unit 3 -P1 -P1-T8-P1-T9 (see note above)
Node 0 on 590 or 595 -P2-C9 -P2-C9-T1-P2-C9-T2
068F / 1679 570 secondary unit 3 -P1-C7 -P1-C7-T1-P1-C7-T2 (see note above)
0690 / 1680 Node 0 on 590 or 595 -P2-C11 -P2-C11-T1-P2-C11-T2
0692 / 1682 Node 0 on 590 or 595 -P2-C13 -P2-C13-T1-P2-C13-T2
0694 / 1684 Node 1 on 590 or 595 -P3 Internal
Note: The normal loop status is OPEN because the internal links are not joined to form a loop.
0695 / 1685 Node 1 on 590 or 595 -P3-C1 -P3-C1-T1-P3-C1-T2
0696 / 1686 Node 1 on 590 or 595 -P3 Internal
0697 / 1687 Node 1 on 590 or 595 -P3-C3 -P3-C3-T1-P3-C3-T2
0698 / 1688 Node 1 on 590 or 595 -P3-C5 -P3-C5-T1-P3-C5-T2
069A / 1690 Node 1 on 590 or 595 -P3-C6 -P3-C6-T1-P3-C6-T2
069C / 1692 Node 1 on 590 or 595 -P3-C8 -P3-C8-T1-P3-C8-T2
069E / 1694 Node 1 on 590 or 595 -P3-C9 -P3-C9-T1-P3-C9-T2
06A0 / 1696 Node 1 on 590 or 595 -P3-C11 -P3-C11-T1-P3-C11-T2
06A2 / 1698 Node 1 on 590 or 595 -P3-C13 -P3-C13-T1-P3-C13-T2
06A4 / 1700 Node 2 on 590 or 595 -P4-C1 -P4-C1-T1-P4-C1-T2
06A6 / 1702 Node 2 on 590 or 595 -P4-C3 -P4-C3-T1-P4-C3-T2
06A8 / 1704 Node 2 on 590 or 595 -P4-C5 -P4-C5-T1-P4-C5-T2
06AA / 1706 Node 2 on 590 or 595 -P4-C6 -P4-C6-T1-P4-C6-T2
06AC / 1708 Node 2 on 590 or 595 -P4-C8 -P4-C8-T1-P4-C8-T2
06AE / 1710 Node 2 on 590 or 595 -P4-C9 -P4-C9-T1-P4-C9-T2
06B0 / 1712 Node 2 on 590 or 595 -P4-C11 -P4-C11-T1-P4-C11-T2
06B2 / 1714 Node 2 on 590 or 595 -P4-C13 -P4-C13-T1-P4-C13-T2
06B4 / 1716 Node 3 on 590 or 595 -P5-C1 -P5-C1-T1-P5-C1-T2
06B6 / 1718 Node 3 on 590 or 595 -P5-C3 -P5-C3-T1-P5-C3-T2
06B8 / 1720 Node 3 on 590 or 595 -P5-C5 -P5-C5-T1-P5-C5-T2
06BA / 1722 Node 3 on 590 or 595 -P5-C6 -P5-C6-T1-P5-C6-T2
06BC / 1724 Node 3 on 590 or 595 -P5-C8 -P5-C8-T1-P5-C8-T2
06BE / 1726 Node 3 on 590 or 595 -P5-C9 -P5-C9-T1-P5-C9-T2
06C0 / 1728 Node 3 on 590 or 595 -P5-C11 -P5-C11-T1-P5-C11-T2
06C2 / 1730 Node 3 on 590 or 595 -P5-C13 -P5-C13-T1-P5-C13-T2