The battery for the time-of-day battery is low or failing.
Use the table below to determine which FRU to replace and how to replace it.
To determine which Time-of-day (TOD) battery to replace on a model 570, 590, or 595, use the last byte in word 3 of the primary SRC.
If you have access to the Advanced System Management Interface (ASMI), log on and display the details of the service processor error log. Using the Platform Event Log id (shown in the first table of each detail of the log), look at the first byte.
If you have access to an Hardware Management Console (HMC), log in as PE user and bring up Manage Serviceable Events under the Service Focal Point screen. Display the events for the corresponding service processor system, then double-click the system to see the details. Look at the Field Platform log ID, which contains a decimal value that you need to convert to a hexadecimal value.
| System model | Name of symbolic FRU to locate | FRU name | Link to locations information |
|---|---|---|---|
| 505 | TOD_BAT | Time-of-day (TOD) battery | Locations — model 505 |
| 510 and OpenPower® 710 | TOD_BAT | Time-of-day (TOD) battery | Locations — model 510 and OpenPower 710 |
| 520 | TOD_BAT | Time-of-day (TOD) battery | Locations — Model 520 |
| 550 and OpenPower 720 | TOD_BAT | Time-of-day (TOD) battery | Locations — OpenPower 720 and Model 550 |
| 570 | TOD_BAT | Primary unit, Time-of-day (TOD) batterySecondary unit 1, Time-of-day (TOD) battery | Locations — Model 570 |
| 575 | TOD_BAT | Time-of-day (TOD) battery | Locations — model 575 |
| 590 and 595 | TOD_BAT | Service processor card 0Service processor card 1 | Locations — model 590 and 595 |
This ends the procedure.