The battery charger is reporting a load fault.
- Is the reference code 4414?
- No: Go to Start of call procedure.
This
ends the procedure.
- Yes: Perform the first four steps of PWR1906 to
isolate the failing item, then return here and continue with the next step.
- Is the reference code 4414 still present?
- No: Continue with the next step.
- Yes: Replace the battery power unit charger (see Part number catalog).
This
ends the procedure.
- Power on the system. Does the failing expansion unit power on successfully?
- Remove the ac line cord from the outlet. Does a battery power unit
charger fault occur?
- Yes: Replace the battery power unit charger (see Part number catalog).
This
ends the procedure.
- No: This ends the procedure.