subscribe iconSubscribe to this information

MASBUS

The multi-adapter bridge detected a problem with a connection to a PCI adapter that it controls either in a physical card location or embedded in a FRU.

The problem is either in the bus between the multi-adapter bridge and the adapter, or with the card slot. The card location may or may not have an installed card.

  1. Are you working from the serviceable event view and a card location is listed with this FRU?
    • Yes: Then the listed card location is where the error is located. Continue with the next step.
    • No: Record the bus number value, BBBB, in word 7 of the reference code (see Breaking down a RIO/HSL or PCI bus reference code). Search for the bus number in the resource view available to you on the HMC or operating system, or in the System Configuration Listing, to determine which system unit or I/O unit contains the failing component. Record the unit's machine type, model, or feature and continue with the next step.
  2. The failing component is the FRU containing the physical or embedded card slot that is controlled by the multi-adapter bridge. Identify the system model, I/O unit, or machine type that is indicated by the location in the serviceable event view, or by using the bus number. Use the following table to find the appropriate service information.
    Table 1. Failing component service information for MASBUS
    Model or expansion unit Name of FRU to exchange FRU location Link to locations information
    515, 520, 525 System unit logic planar -P1 Locations — Model 515, 520, 525
    550 and OpenPower® 720 System unit logic planar -P1 Locations — OpenPower 720 and Model 550
    570 Logic planar for system primary unit or secondary unit -P1 Locations — Model 570
    575 System backplane -P1 Locations — model 575
    5074, 8079-002, 8093-002 expansion I/O tower Tower card CB1 Locations — 5074, 8079-002, and 8093-002 expansion I/O units
    5079 expansion tower Tower card CB1 Locations — 5079 expansion I/O unit
    5088, 0588 expansion unit Tower card CB1 Locations — 5088 and 0588 expansion I/O units
    5094, 5294, 8094-002 expansion I/O unit Tower card CB1 Locations — 5094, 5294, and 8094-002 expansion I/O units
    5095, 0595 expansion tower Tower card CB1 Locations — 5095 and 0595 expansion I/O units
    Type 1519 — external xSeries® server Integrated xSeries adapter card Follow the RIO/HSL cables Locations — Integrated xSeries adapter card (IXA)
    7311-D10, 7311-D11, and 5790 I/O unit logic planar -P1 Locations — 7311-D10 and 7311-D11 and 5790 expansion unit
    7040-61D I/O unit logic planar -P1 Locations — 61D
    -P2

This ends the procedure.