You might need to install memory modules in the server. Use the procedure in this section to perform this task.
If your system is managed by the Hardware Management Console (HMC), see Table 1 for the order in which you place the memory modules, and then use the HMC to complete the steps for installing memory modules. For instructions, see Install a feature using the Hardware Management Console. If you do not have an HMC, complete the following steps to install memory modules:

| System unit | Processor card | Where to install memory modules |
|---|---|---|
| Enclosure 1 | P2-C1 | Slots C1, C3, C6, and C8 |
| Enclosure 1 | P2-C2 | Slots C1, C3, C6, and C8 |
| Enclosure 2 | P2-C1 | Slots C1, C3, C6, and C8 |
| Enclosure 2 | P2-C2 | Slots C1, C3, C6, and C8 |
| Enclosure 3 | P2-C1 | Slots C1, C3, C6, and C8 |
| Enclosure 3 | P2-C2 | Slots C1, C3, C6, and C8 |
| Enclosure 4 | P2-C1 | Slots C1, C3, C6, and C8 |
| Enclosure 4 | P2-C2 | Slots C1, C3, C6, and C8 |
| Enclosure 4 | P2-C1 | Slots C2, C4, C5, and C7 |
| Enclosure 4 | P2-C2 | Slots C2, C4, C5, and C7 |
| Enclosure 3 | P2-C1 | Slots C2, C4, C5, and C7 |
| Enclosure 3 | P2-C2 | Slots C2, C4, C5, and C7 |
| Enclosure 2 | P2-C1 | Slots C2, C4, C5, and C7 |
| Enclosure 2 | P2-C2 | Slots C2, C4, C5, and C7 |
| Enclosure 1 | P2-C1 | Slots C2, C4, C5, and C7 |
| Enclosure 1 | P2-C2 | Slots C2, C4, C5, and C7 |