Server specifications provide detailed information for your server, including dimensions, electrical, power, temperature, environment, and service clearances.
Use the following specifications to plan for your server.
| Pictured is model 9406-820. The 5074, 5079, 507, or 5078 expansion unit is available with model 9406-820. Dimensions are shown for model 9406-820 only. |
![]() |
||
| Dimensions | Width | Depth | Height |
| Metric | 483 mm | 728 mm | 610 mm |
| English | 19.0 in. | 28.7 in. | 24.0 in. |
| Maximum configuration weight | 96 kg (210 lb.) | ||
| Electrical | |||
| kVA (maximum) | 0.862 | ||
| Rated voltage and frequency | 100-127/200-240 V ac at 50-60 plus or minus 0.5 Hz | ||
| Thermal output (maximum) | 2867 Btu/hr | ||
| Power requirements (maximum) | 840 W | ||
| Power factor | 0.95 | ||
| Inrush current | 90 A | ||
| Leakage current (maximum) | 3.5 mA | ||
| Phase | 1 | ||
| Compatible plug types | 45, 6, 10, 18, 19, 22, 23, 24, 25, 32, 34 | ||
| Power cord length | 1.8 m (6 ft.) (U.S. only), 4.3 m (14 ft.) | ||
| High-speed link (HSL) cable requirements | |||
| Temperature requirements | |||
| Operating | 10 degrees to 38 degrees C (50 degrees to 100.4 degrees F) | ||
| Nonoperating | 1 degrees to 60 degrees C (33.8 degrees to 140 degrees F) | ||
| Environment requirements | Operating | Nonoperating | |
| Noncondensing humidity | 8 to 80% | 8 to 80% | |
| Wet bulb temperature | 22.8 degrees C (73 degrees F) | 27 degrees C (80.6 degrees F) | |
| Maximum altitude | 3048m (10000 ft.) | ||
| Noise emissions1 | Operating | Idle | |
| LWAd Category 2E, General Business | 6.1 bel | 5.9 bel | |
| LpAm (1-meter bystander) | 43 dB | 40 dB | |
| Service clearances | |||
| Front | Back | Sides2 | Top2 |
| 762 mm | 762 mm | 762 mm | 762 mm |
| 30 in. | 30 in. | 30 in. | 30 in. |
Notes:
|
|||