subscribe iconSubscribe to this information

Model 9406-270 server specifications

Server specifications provide detailed information for your server, including dimensions, electrical, power, temperature, environment, and service clearances.

Use the following specifications to plan for your server.

Table 1. Server specifications

Pictured is model 9406-270.

The 7104 expansion unit is available with model 9406-270.

The 7104 expansion unit requires a power cord.

Dimensions are shown for model 9406-270 only.

model 9406-270

Dimensions 9406-270 Width 9406-270 with 7104 Width 9406-270 Depth 9406-270 Height
Metric 366 mm 552 mm 728 mm 610 mm
English 14.5 in. 21.9 in. 28.7 in. 24.0 in.
  Model 9406-270 Model 9406-270 with 7104
Maximum configuration weight 52.7 kg (116 lb.) 79.5 kg (175 lb.)
Electrical Model 9406-270 7104 expansion unit
Maximum kVA (each has its own power cord) 0.421 0.368
Rated voltage and frequency3 100-127/200-240 V ac at 50-60 plus or minus 0.5 Hz
Thermal output (maximum) 1365 Btu/hr 1194 Btu/hr
Power requirements (IP measurement) maximum (watts) 400 350
Power factor 0.95
Inrush current 41 A
Leakage current (maximum) 3.5 mA
Phase 1
Compatible plug types 4, 5, 6, 10, 18, 19, 22, 23, 24, 25, 32, 34
Power cord length 2.7 m (9 ft.), 1.8 m (6 ft.) (U.S. and Canada only), 4.3 m (14 ft.)
Temperature requirements
Operating 10 degrees to 38 degrees C (50 degrees to 100.4 degrees F)
Nonoperating 1 degrees to 60 degrees C (33.8 degrees to 140 degrees F)
Environment requirements Operating Nonoperating
Noncondensing humidity 8 to 80% 8 to 80%
Wet bulb temperature 23 degrees C (73.4 degrees F) 27 degrees C (80.6 degrees F)
Maximum altitude 3048 m (10000 ft.)
Noise emissions1 Operating Idle
LWAd (Category 2E, General business) 9406-270 only 5.9 bels 5.8 bels
LWAd (Category 2E, General business) 9406-270 with 7104 6.3 bels 6.1 bels
LpAm (1-meter bystander) 9406-270 only 41 dB 40 dB
LpAm (1-meter bystander) 9406-270 with 7104 45 dB 43 dB
Service clearances
Front Back Sides 2 Top 2
762 mm 762 mm 762 mm 762 mm
30 in. 30 in. 30 in. 30 in.

Notes:

  1. For a description of noise emission values, see Acoustics.
  2. Side and top clearances are optional when operating.
  3. The power supplies automatically accept any voltage with the published rated voltage range. If dual power supplies are installed and operating, the power supplies draw approximately equal current from the utility (mains) and provide approximately equal current to the load.

Send feedback | Rate this page