The partition firmware detected a failure. The first eight characters in the display represent the SRC. Any additional characters represent the associated location code. Record the location code as well as the reference code, then find the SRC in the following table.
Table 1. (DAxx) Partition firmware reference (error) codes
| Reference Code | Description/Action Perform all actions before exchanging Failing Items | Failing Item |
|---|---|---|
| DA080001 | An IDE device remained busy for a longer period than the time out period | FWFWPBL |
| DA080002 | The IDE controller senses IDE devices but with errors.
|
|
| DA080010 | An IDE device is busy longer than specified
time-out period.
Retry the operation. |
FWIDE1 |
| DA080011 | An IDE command timed out; command is exceeding
the period allowed to complete.
Retry the operation. |
FWIDE1 |
| DA080012 | The ATA command failed | FWIDE2 |
| DA080013 | The media is not present in the tray
Retry the operation. |
FWIDE1 |
| DA080014 | The media has been changed
Retry the operation. |
FWIDE1 |
| DA080015 | The packet command failed; the media might
not be readable.
Retry the operation. |
FWIDE1 |