(BF75) Linux reference codes

The Linux® operating system detected a failure in the ipr driver.

The first five characters (BFxxx) of these SRCs indicate the driver or subsystem responsible for the error, and the last three characters specifies the error condition. The last three characters of the SRCs are arranged such that 1xx is lowest severity and Fxx is highest severity. For example:

Use the following table to locate the last four characters of the (BF75) Linux SRC that you want to find, then perform the suggested actions.

Note:
If the suggested action in the Description/Action column does not work (or if that column does not contain a suggested action), use the action specified in the Failing Item column.

Table 1. (BF75) Linux reference codes

Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
1800 8155: An unknown error was received.

Have the customer update the device driver.

NEXTLVL
1A00 Firmware file %s not found.

Have the customer update the adapter microcode.

NEXTLVL
1A01 Invalid microcode buffer.

Have the customer update the adapter microcode.

NEXTLVL
1A02 Microcode buffer allocation failed.

Have the customer update the adapter microcode.

NEXTLVL
1A03 Microcode buffer copy to DMA buffer failed.

Have the customer update the adapter microcode.

NEXTLVL
1A04 Microcode download required.

Have the customer update the adapter microcode.

NEXTLVL
1A05 Failed to map microcode download buffer.

Have the customer update the adapter microcode.

NEXTLVL
1A06 8151: IOA microcode error.

Have the customer update the adapter microcode and the device driver.

NEXTLVL
1C00 Adapter being reset due to command timeout.

Have the customer update the adapter microcode.

IOADPTR
1C01 Invalid resource address.

Have the customer update the device driver.

IOADPTR
1D00 7001: IOA sector reassignment successful. Media error. IO_DEV
1D01 Unsolicited device bus message received. IO_DEV
1D02 Device hardware error. IO_DEV
1D03 Predictive failure analysis. IO_DEV
1D04 Device error. May occur normally during concurrent maintenance. IO_DEV
1D05 Out of alternate sectors for disk storage. IO_DEV
1D06 9031: Array protection temporarily suspended, protection resuming.

Hardware configuration error.

Perform MAP 3310 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D07 This message indicates one of the following conditions:
  • Array protection temporarily suspended
  • IOA detected device error
  • Cache data belongs to devices other than those attached
  • Maximum number of arrays already exist
  • Incorrect hardware configuration change has been detected

Perform MAP 3390 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D08 IOA detected a SCSI bus configuration error. Device bus error, message or command phase.

Perform MAP 3350 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D09 IOA cache data exists for a missing or failed device.

Perform MAP 3332 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D0A Disk unit has been modified after the last known status. Incorrect hardware configuration change has been detected.

Perform MAP 3333 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D0B A permanent cache battery pack failure occurred.

Perform MAP 3300 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D0C Cache data associated with attached devices cannot be found.

Perform MAP 3320 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D0D Array missing two or more devices with only one device present.

Perform MAP 3311 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D0E One or more array members not at required physical locations.

Perform MAP 3312 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D0F Array is missing a device and parity is out of sync.

Perform MAP 3313 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D10 Required cache data cannot be located for a disk unit.

Perform MAP 3331 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D11 IOA resources not available due to previous problems.

Perform MAP 3321 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1D12 Disk unit requires initialization before use.

Perform MAP 3334 in the PCI-X SCSI RAID Controller Reference Guide for Linux.

Link outside information center
NEXTLVL
1F00 Permanent IOA failure. IOADPTR
1F01 Invalid response handle from IOA. IOADPTR
1F02 IOA unit check with no data. IOADPTR
1F03 IOA taken offline - error recovery failed. IOADPTR
1F04 Adapter not supported in this hardware configuration.

Remove the unsupported adapter from the system.

IOADPTR
1F05 Failed to set PCI DMA mask. IOADPTR
1F06 Write of cache line size failed. IOADPTR
1F07 Failed to save PCI configuration space. IOADPTR
1F08 PCI bus error. IOADPTR
1F08 Soft PCI bus error. IOADPTR
1F09 Adapter hardware error. IOADPTR

Send feedback |  Rate this page