Resolving a power problem

Learn how to identify the service action that is needed to resolve a power problem.

Procedure

  1. Is the identify LED on the front of the system flashing red slowly at 0.25 Hz? For more information about LEDs, see LEDs on the 9006-12P system or LEDs on the 5104-22C, 9006-22C, or 9006-22P system.
    If Then
    Yes: Continue with the next step.
    No: No service action is required. This ends the procedure.
  2. Perform the following actions, one at a time until the problem is resolved:
    1. Ensure that all of the power cords are fully seated in the power supplies.
    2. Ensure that the power supply is fully seated in the system.
    3. Ensure that the power supply fan is not blocked.
    4. Ensure that all of the power cords are fully seated in the power distribution units (PDUs) or wall outlets.
    5. If the power cords are plugged into PDUs, ensure that the PDUs are turned on.
    6. Replace the power cords.
    7. Replace the power supplies.
      • If your system is a 5104-22C or 9006-22C, go to 5104-22C or 9006-22C locations to identify the physical location and the removal and replacement procedure.
      • If your system is a 9006-12P, go to 9006-12P locations to identify the physical location and the removal and replacement procedure.
      • If your system is a 9006-22P, go to 9006-22P locations to identify the physical location and the removal and replacement procedure.
    This ends the procedure.