Resolving a power problem
Learn how to identify the service action that is needed to resolve a power problem.
Procedure
-
Is the identify LED on the front of the system flashing red slowly at 0.25 Hz? For more
information about LEDs, see LEDs on the 9006-12P system or LEDs on the 5104-22C, 9006-22C, or 9006-22P system.
If Then Yes: Continue with the next step. No: No service action is required. This ends the procedure. -
Perform the following actions, one at a time until the problem is resolved:
- Ensure that all of the power cords are fully seated in the power supplies.
- Ensure that the power supply is fully seated in the system.
- Ensure that the power supply fan is not blocked.
- Ensure that all of the power cords are fully seated in the power distribution units (PDUs) or wall outlets.
- If the power cords are plugged into PDUs, ensure that the PDUs are turned on.
- Replace the power cords.
- Replace the power supplies.
- If your system is a 5104-22C or 9006-22C, go to 5104-22C or 9006-22C locations to identify the physical location and the removal and replacement procedure.
- If your system is a 9006-12P, go to 9006-12P locations to identify the physical location and the removal and replacement procedure.
- If your system is a 9006-22P, go to 9006-22P locations to identify the physical location and the removal and replacement procedure.