MAP 3242
Use this MAP to resolve the following problem:
Configuration error: incorrect connection between cascaded enclosures (SRN nnnn-4010) for a PCIe3 controller.
- Incorrect cabling of cascaded device enclosures
- Use of an unsupported device enclosure
Step 3242-1
- Follow the steps in Examining the hardware error log and return here.
- Obtain the Resource field from the Detail Data / PROBLEM
DATA section as illustrated in the following example:
Detail Data PROBLEM DATA 0001 0800 1910 00F0 0408 0100 0101 0000 0150 003E 0000 0030 57B5 4100 0000 0001 0004 FFFF FFFF FFFF 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0004 AA98 ^ | Resource is 0004FFFF
Using the resource found in step 2, see SAS resource locations to understand how to identify the controller's port to which the device, or device enclosure, is attached.
For example, if the resource is 0004FFFF, port 04 on the adapter is used to attach the device or device enclosure that is experiencing the problem.
Step 3242-2
Review the device enclosure cabling and correct the cabling as required. To see example device configurations with SAS cabling, see Planning for serial-attached SCSI cables.
If unsupported device enclosures are attached, then either remove or replace them with supported device enclosures.
Step 3242-3
- Start Diagnostics and select Task Selection on the Function Selection display.
- Select Run Diagnostics.
- Select the adapter resource.
- Select System Verification.
- No
- Go to Step 3242-4.
- Yes
- Contact your hardware service provider.
Step 3242-4
When the problem is resolved, see the removal and replacement procedures topic for the system unit on which you are working and perform the Verifying a repair procedure.