8335-GTB locations

Use this information to find the location of a FRU in the system unit.

Rack views

The following diagrams show field-replaceable unit (FRU) layouts in the system. Use these diagrams with the following tables.

Figure 1. Front view
Front view
Table 1. Front view locations
Index number FRU description FRU removal and replacement procedures
1 Fan 1 See Removing and replacing fans in the 8335-GTB.
2 Fan 2
3 Fan 3
4 Fan 4
5 HDD 0 See Removing and replacing a disk drive in the 8335-GTB.
6 HDD 1
7 Power switch and cable See Removing and replacing the power switch and cable in the 8335-GTB.
8 Front USB cable and connector See Removing and replacing the front USB cable and connector in the 8335-GTB.
Figure 2. Top view
Top view
Table 2. Top view locations
Index number FRU description FRU removal and replacement procedures
7 Power switch and cable See Removing and replacing the power switch and cable in the 8335-GTB.
8 Front USB cable and connector See Removing and replacing the front USB cable and connector in the 8335-GTB.
9 Disk drive and fan card See Removing and replacing the disk drive and fan card in the 8335-GTB.
10 Memory riser 1 See Removing and replacing memory risers in the 8335-GTB.
11 Memory riser 2
12 Memory riser 3
13 Memory riser 4
14 Memory riser 5
15 Memory riser 6
16 Memory riser 7
17 Memory riser 8
18 Disk and fan signal cable See Removing and replacing the disk and fan signal cable in the 8335-GTB.
19 Fan power cable See Removing and replacing the fan power cable in the 8335-GTB.
20 CPU 1 See Removing and replacing a system processor module for the 8335-GTB.
21 CPU 2
22 Time-of-day battery See Removing and replacing the time-of-day battery in the 8335-GTB.
23 Power riser with time-of-day battery See Removing and replacing power risers in the 8335-GTB.
24 Power riser without time-of-day battery
25 GPU 1 See Removing and replacing a graphics processing unit in the 8335-GTB.
26 GPU 2
27 GPU 3
28 GPU 4
Figure 3. Rear view
Rear view
Table 3. Rear view locations
Index number FRU description FRU removal and replacement procedures
29 PSU 2 See Removing and replacing a power supply in the 8335-GTB.
30 PSU 1
31 Baseboard management controller (BMC) card See Removing and replacing the BMC card in the 8335-GTB.
32 PCIe adapter 1 See Removing and replacing PCIe adapters in the 8335-GTB.
33 PCIe adapter 2
34 PCIe adapter 3

Memory locations

The following diagram shows memory riser cards and their corresponding field-replaceable unit (FRU) layouts in the system. Use this diagram with the following table.

Figure 4. Memory locations on memory riser cards
Memory locations on memory riser cards

The following table provides the memory locations on the memory riser cards.

Table 4. Memory locations on memory riser cards
Index number Memory riser card FRU description FRU removal and replacement procedures
35 Memory riser 1 DIMM 1 See Removing and replacing memory DIMM in the 8335-GTB.
Memory riser 2 DIMM 5
Memory riser 3 DIMM 9
Memory riser 4 DIMM 13
Memory riser 5 DIMM 17
Memory riser 6 DIMM 21
Memory riser 7 DIMM 25
Memory riser 8 DIMM 29
36 Memory riser 1 DIMM 2 See Removing and replacing memory DIMM in the 8335-GTB.
Memory riser 2 DIMM 6
Memory riser 3 DIMM 10
Memory riser 4 DIMM 14
Memory riser 5 DIMM 18
Memory riser 6 DIMM 22
Memory riser 7 DIMM 26
Memory riser 8 DIMM 30
37 Memory riser 1 DIMM 3 See Removing and replacing memory DIMM in the 8335-GTB.
Memory riser 2 DIMM 7
Memory riser 3 DIMM 11
Memory riser 4 DIMM 15
Memory riser 5 DIMM 19
Memory riser 6 DIMM 23
Memory riser 7 DIMM 27
Memory riser 8 DIMM 31
38 Memory riser 1 DIMM 4 See Removing and replacing memory DIMM in the 8335-GTB.
Memory riser 2 DIMM 8
Memory riser 3 DIMM 12
Memory riser 4 DIMM 16
Memory riser 5 DIMM 20
Memory riser 6 DIMM 24
Memory riser 7 DIMM 28
Memory riser 8 DIMM 32



Last updated: Thu, November 07, 2019