B6006908

Explanation

High Speed Link (HSL) or PCI bridge card slot I/O bridge failure.

Response

LIC data in the I/O bus VPD could not be accessed. The I/O Bus identified in the SRC may not have become operational.

If there is a B6xx 6906 reference code, close this problem in the serviceable event view you are working with and work the 6906 error.

For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed.

If the Service Action Log or serviceable event view on the hardware management console or service processor is available then use the failing item list presented there for servicing this reference code.

If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed.

NOTE: A fiber optic cleaning kit may be required for optical HSL connections.

Failing Item