Product specifications
- System specifications
- Fibre Channel
- LEDs
- Weight and physical dimensions
- Environmental requirements
- Power supply specifications (per PSU)
- Data port specifications (Fibre Channel)
- Serial port specifications (pinout RJ-45)
- Memory specifications
- Regulatory compliance (EMC)
- Regulatory compliance (safety)
- Regulatory compliance (environmental)
System specifications
| System component | Description |
|---|---|
Enclosure |
1U, nonport-side front-to-back exhaust airflow, power from back |
Power inlet |
C14 |
Power supplies |
Dual, hot-swappable redundant power supplies with integrated system cooling fans |
Fans |
Three fans per power supply and fan assembly unit |
Cooling |
Port side to the nonport-side of the switch (nonport-side exhaust) and nonport-side to the port side (port-side exhaust) |
System architecture |
Nonblocking shared memory switch |
System processors |
Freescale T1022 CPU |
Port-to-port latency |
< 70 nanoseconds with no contention (destination port is free) |
Fibre Channel
| System component | Description |
|---|---|
Fibre Channel ports |
48 SFP+ ports that support any combination of Short Wavelength (SWL) and Long Wavelength (LWL) or Extended Long Wavelength (ELWL) optical media. 4 QSFP ports that support 32-Gbps QSFP transceivers. The SFP+ ports are capable of auto-negotiating
to 4, 8, 16, or 32 Gbps speed depending on the SFP+ model and the
minimum supported speed of the optical transceiver at the other end
of the link.
|
ANSI Fibre Channel protocol |
FC-PH (Fibre Channel Physical and Signaling Interface standard) |
Modes of operation |
Fibre Channel Class 2 and Class 3 |
Fabric initialization |
Complies with FC-SW-3 Rev. 6.6 |
FCIP (IP over Fibre Channel) |
Complies with FC-IP 2.3 of FCA profile |
Port Status |
Bicolor LED (amber/green) |
Other
| System component | Description |
|---|---|
Serial console port |
One three-wire (Tx, Rx, Gnd) UART serial port |
Ethernet management port |
One 1000Base-X / 100Base-TX port / 10Base-T |
USB port |
One external USB port |
LEDs
| System component | Description |
|---|---|
System power LED |
One green system power status LED (upper) on the port side. |
System status LED |
One bicolor (green/amber) system status LED (lower) on the port side. |
Ethernet port link LED |
One link LED on the left of the RJ45 connector. Glows green for 1000 Mbps and amber for 100/10 Mbps. |
Ethernet port activity LED |
One activity LED on the right of the RJ45 connector. |
Serial console port LED |
The serial console port LEDs remain off at all times, even when a cable is inserted and the link is active. |
FC port status LED |
64 bicolor (green/amber) port status LEDs. One for each SFP+ port and four for each QSFP port on the switch. |
Power supply and fan assembly status LED |
One green power supply and fan assembly status LED on each power supply and fan assembly on the nonport-side of the switch. |
Other
| System component | Description |
|---|---|
Serial cable |
RJ-45 console cable |
RJ-45 to DB9 adapter |
RJ-45 to DB9 for console cable |
RJ-45 connector |
Uses an RJ-45 connector for the serial port |
Weight and physical dimensions
Empty weight refers to the device with two power supply and fan assemblies installed but no SFP+ or QSFP transceivers.
| Model | Height | Width | Depth | Weight (empty) | Weight (fully loaded) |
|---|---|---|---|---|---|
SAN64B-6 switch |
4.39 cm 1.73 inches |
44.00 cm 17.32 inches |
35.56 cm 14.00 inches |
7.71 kg 17.00 lb |
8.53 kg 18.80 lb |
Environmental requirements
| Condition | Operational | Non-operational |
|---|---|---|
Ambient temperature |
0°C to 40°C (32°F to 104°F) |
-25°C to 70°C (-13°F to 158°F) |
Relative humidity (non-condensing) |
10% to 85% at 40°C (104°F) |
10% to 90% non-condensing |
Altitude (above sea level) |
0 to 3000 m (9,842 feet) |
0 to 12000 m (39,370 feet) |
Shock |
20.0 G, 6 ms, half-sine wave |
33.0 G, 11 ms, half-sine wave, 3G Axis |
Vibration |
0.25 G sine, 0.4 gms random, 5 – 500 Hz |
5Hz at 0.5grms, 10-500Hz at 1.0grms (sine vibration); 3-500Hz at 1.12grms (random vibration) |
Airflow |
Maximum: 71.36 cmh (42 cfm) Nominal: 59.47 cmh (35 cfm) |
N/A |
Heat dissipation |
Refer to the Power consumption table |
N/A |
Operating noise |
Maximum: 65 dB |
N/A |
Power supply specifications (per PSU)
| Power supply model | Maximum output power rating (DC) | Input voltage | Input line frequency | Maximum input current | Input line protection | Maximum inrush current |
|---|---|---|---|---|---|---|
XBR-G250WPSAC-F |
250 W |
100 - 240 VAC (nominal) 90 - 264 VAC (range) |
50/60 Hz (nominal) 47 - 63 Hz (range) |
3.5 A |
Line fused |
50 A peak @ 240 VAC for <0ms, 10 ms - 150 ms, <15A peak. 50 A peak @ 240 VAC at cold start for <10ms. 15 A peak for cycles 10 ms - 150 ms. <3.5 A peak for >150 ms |
XBR-G250WPSAC-R |
250 W |
100 – 240 VAC (nominal) 90 – 264 VAC (range) |
50/60 Hz (nominal) 47 – 63 Hz (range) |
3.5 A |
Line Fused |
50 A peak @ 240 VAC for <10 ms, 10 ms - 150 ms, <15 A peak. 50 A peak @ 240 VAC at cold start for <10 ms. 15 A peak for cycles 10 ms - 150 ms. <3.5 A peak for >150 ms |
Power consumption (typical configuration)
| Model name | @100 VAC input | @200 VAC input | @48 VDC input | Minimum number of power supplies | Notes |
|---|---|---|---|---|---|
SAN64B-6 switch |
1.93 A 192 W 655 BTU/hr |
0.97 A 190 W 649 BTU/hr |
N/A |
1 (But, input current is for 1 PSU. Watts and BTUs/hr are with 2 PSUs). |
Fully configured all ports with 25% traffic rate, fans at high speed, and input power +/- 5% tolerance. |
Power consumption (maximum configuration)
| Model name | @100 VAC input | @200 VAC input | @48 VDC input | Minimum number of power supplies | Notes |
|---|---|---|---|---|---|
SAN64B-6 switch |
2.07 A 204 W 696 BTU/hr |
1.03 A 202 W 690 BTU/hr |
N/A |
2 (But, input current is for 1 PSU. Watts and BTUs/hr are with 2 PSUs). |
Fully configured all ports with 100% traffic rate, fans at high speed, and input power +/- 5% tolerance. |
Power consumption (idle configuration)
| Model name | @100 VAC input | @200 VAC input | @48 VDC input | Minimum number of power supplies | Notes |
|---|---|---|---|---|---|
SAN64B-6 switch |
1.54 A 155 W 529 BTU/hr |
0.77 A 154 W 526 BTU/hr |
N/A |
1 (But, input current is for 1 PSU. Watts and BTUs/hr are with 2 PSUs). |
All optics loaded but not initialized and the system completed boot up, fans at nominal speed, and input power +/- 5% tolerance. |
Data port specifications (Fibre Channel)
| Name | Port Numbers | Media Type | Description |
|---|---|---|---|
SAN64B-6 switch |
0 to 47 |
10-, 16-, or 32-Gbps SFP+ optical ports |
Can be an F_Port, N_Port, E_Port, or EX_Port |
48 to 63 |
4 x 16-Gbps (64 Gbps) or 4 x 32-Gbps (128 Gbps) QSFP optical ports |
Can be an E_Port or EX_Port |
Fibre Channel data transmission ranges
| Port speed (Gbps) | Cable size (microns) | Short wavelength (SWL) | Long wavelength (LWL) | Extended long wavelength (ELWL) |
|---|---|---|---|---|
4 |
50 |
150 m (492 ft) (OM2) 380 m (1,264 ft) (OM3) 400 m (1,312 ft) (OM4) |
N/A |
N/A |
62.5 |
70 m (229 ft) |
N/A |
N/A |
|
9 |
N/A |
30 km (18.6 miles) |
N/A |
|
8 |
50 |
50 m (164 ft) (OM2) 150 m (492 ft) (OM3) 190 m (623 ft) (OM4) |
N/A |
N/A |
62.5 |
21 m (68 ft) |
N/A |
N/A |
|
9 |
N/A |
10 km (6.2 miles) |
N/A |
|
10 |
50 |
82 m (269 ft) (OM2) 300 m (984 ft) (OM3) 550 m (1,804 ft) (OM4) |
N/A |
N/A |
62.5 |
33 m (108 ft) |
N/A |
N/A |
|
9 |
N/A |
10 km (6.2 miles) |
N/A |
|
16 |
50 |
35 m (115 ft) (OM2) 100 m (328 ft) (OM3) 125 m (410 ft) (OM4) |
N/A |
N/A |
62.5 |
15 m (49 ft) |
N/A |
N/A |
|
9 |
N/A |
10 km (6.2 miles) |
N/A |
|
32 |
50 |
70 m (230 ft) (OM3) 100 m (328 ft) (OM4) |
N/A |
N/A |
62.5 |
N/A |
N/A |
N/A |
|
9 |
N/A |
10 km (6.2 miles) |
N/A |
Serial port specifications (pinout RJ-45)
| Pin | Signal | Description |
|---|---|---|
1 |
Not supported |
N/A |
2 |
Not supported |
N/A |
3 |
UART1_RXD |
Receive data |
4 |
GND |
Logic ground |
5 |
GND |
Logic ground |
6 |
UART2_TXD |
Transmit data |
7 |
Not supported |
N/A |
8 |
Not supported |
N/A |
Serial port specifications (protocol)
| Parameter | Value |
|---|---|
Baud |
9600 |
Data bits |
8 |
Parity |
None |
Flow control |
None |
Stop bits |
1 |
Memory specifications
| Memory | Type | Size |
|---|---|---|
Main Memory |
DDR3L SDRAM with 8-bit ECC, SORDIMM package, operating at 1200 MT/s |
2 GB, 64-bit |
Boot Flash |
Parallel NOR flash embedded memory |
16 MB |
eUSB Module |
- |
2 GB |
Regulatory compliance (EMC)
- FCC Part 15, Subpart B (Class A)
- EN 55022 (CE mark) (Class A)
- EN 55024 (CE mark) (Immunity) for Information Technology Equipment
- ICES-003 (Canada) (Class A)
- AS/NZ 55022 (Australia) (Class A)
- VCCI (Japan) (Class A)
- EN 61000-3-2
- EN 61000-3-3
- EN 61000-6-1
Regulatory compliance (safety)
- CAN/CSA-C22.2 No. 60950/UL 60950
- EN 60825 Safety of Laser Products
- EN 60950/IEC 60950 Safety of Information Technology Equipment
Regulatory compliance (environmental)
- 2014/35/EU and 2014/30/EU
- 2011/65/EU - Restriction of the use of certain hazardous substance in electrical and electronic equipment (EU RoHS).
- 2012/19/EU - Waste electrical and electronic equipment (EU WEEE).
- 94/62/EC - packaging and packaging waste (EU).
- 2006/66/EC - batteries and accumulators and waste batteries and accumulators (EU battery directive).
- 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (EU REACH).
- Section 1502 of the Dodd-Frank Wall Street Reform and Consumer Protection Act of 2010 - U.S. Conflict Minerals.
- 30/2011/TT-BCT - Vietnam circular.
- SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China).
- SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China).