Preparing the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S system for operation after permanently removing a memory module

To prepare the system for operation after you permanently remove memory modules, complete the steps in this procedure.

Procedure

  1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface. If not, do so now.
  2. Slide the service access cover (A) onto the system unit.
  3. Close the release latch (B) by pushing it in the direction shown.
    Figure 1. Installing the service access cover
    Installing the service access cover
  4. Unlock the blue rail safety latches (A) by pushing them inward.
    Ensure that the cable management arms can move freely. Ensure that the cables at the rear of the unit do not catch or bind as you push the unit into the operating position.
    Figure 2. Placing the system into the operating position
    Placing the system into the operating position
  5. Push the system unit (B) back into the rack until both release latches of the system unit lock into position.
    Secure the cable management arm with hook-and-loop fasteners around the back side of the cable management arm, but not around the cables.
  6. Using your labels, reconnect the power cords (A) to the system unit.
    Fasten the power cords to the system using the hook-and-loop fasteners (B) as shown in Figure 3.
    Figure 3. Connecting the power cords
    Connecting the power cords
  7. Start the system. For instructions, see Starting a system.
  8. Turn off the identify LED. For instructions, see Deactivating an identify LED.