Removing an adapter from the 9040-MR9 system
To remove an adapter from the system, complete the steps in this procedure.
Procedure
- Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface. If not, do so now.
-
Remove the cassette from the slot:
-
Squeeze the latch lever (A) and press down on the latch
(B) in the direction shown.
This action pivots the cassette forward and releases the cassette from the slot.
-
Pull out the cassette from its slot.
Figure 1. Removing an adapter cassette from the 9040-MR9 system 
-
Squeeze the latch lever (A) and press down on the latch
(B) in the direction shown.
- Choose from the following options:
-
If your cassette has two adapter retainers and strips, complete the following steps to remove
an adapter from a cassette.
- Open the tailstock clamp (A) by rotating the clamp in the direction that is shown.
- Remove the adapter retainers (B) by rotating them in the direction that is shown and moving them all the way off the strips.
- Open the cassette by pressing and sliding the release bar (C) in the direction that is shown.
-
Remove the adapter.
Figure 2. Removing an adapter from a cassette for the 9040-MR9 system 
-
If your cassette doesn't have two adapter retainers and strips, complete the following steps to
remove the adapter from the cassette.
- Open the tailstock clamp (A) by rotating the clamp in the direction that is shown.
- Open the cassette by pressing and sliding the release bar (B) in the direction that is shown.
-
Remove the adapter.
Figure 3. Removing an adapter from a cassette for the 9040-MR9 system 
- Place the removed adapter on an approved ESD surface.