SIP3149

Use this procedure to resolve the following problem: Incomplete multipath connection between adapter and remote adapter (SRC xxxx9075)

About this task

The possible cause is a failure in the embedded SAS fabric. Use the following table to determine the service action to perform.

Table 1. Service actions for a failure in the embedded SAS fabric
Location of device or devices Service action
5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S This isolation procedure is not supported on these models. Contact your next level of support.
9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S Replace the following FRUs, one at a time, in the order shown until the problem is resolved. See 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S locations to determine the location, part number, and replacement procedure to use for each FRU.
  1. Replace the adapter that logged the error.
    • PCIe3 x8 cache SAS RAID internal adapter (Un-P1-C49 and Un-P1-C49-E1 or Un-P1-C50 and Un-P1-C50-E1)
  2. Replace the partner adapter of the adapter that logged the error.
    • PCIe3 x8 cache SAS RAID internal adapter (Un-P1-C49 and Un-P1-C49-E1 or Un-P1-C50 and Un-P1-C50-E1)
  3. Replace the system backplane at location Un-P1.
9040-MR9 This isolation procedure is not supported on these models. Contact your next level of support.
9080-M9S This isolation procedure is not supported on these models. Contact your next level of support.

This ends the procedure.