IBM PureFlex and IBM Flex System enhanced with new Flex p260 node
IBM United States Hardware Announcement 112-169November 13, 2012
|
At a glance |
The IBM Flex System p260 Compute Node is a standard-width node with two 4-core, 64-bit, 4.0 GHz POWER7+ processors, or two 8-core 64-bit, 3.6 GHz or 4.1 GHz POWER7+ processors and 16 DIMM slots, which can contain up to a maximum of 512 GB of memory. Two optional SAS small form factor (SFF) 2.5-inch hard disk drives (HDDs) or 1.8-inch SATA solid-state drives (SSDs) can be installed in the p260 Compute Node. The p260 is part of IBM Flex System , a new category of computing that integrates multiple server architectures, networking, storage, and system management capability into a single system.
For ordering, contact your IBM® representative, an IBM Business Partner, or IBM Americas Call Centers at 800-IBM-CALL (Reference: YE001).
|
Overview |
To meet today's complex and ever-changing business demands, you need a solid foundation of compute, storage, networking, and software resources that is simple to deploy and can quickly and automatically adapt to changing conditions. You also need to be able to take advantage of broad expertise and proven best practices in systems management, applications, hardware maintenance, and more. The IBM PureFlex System combines leading-edge compute capabilities and advanced IBM storage hardware and storage management along with patterns of expertise and integrates them in complete, optimized solutions.
IBM Flex System p260 Compute Nodes are POWER7® and POWER7+ based servers optimized for virtualization, performance, and extraordinary efficiency. The nodes support IBM AIX® , IBM i, or Linux operating environments and are designed to run a wide variety of workloads in your PureFlex System or Flex System.
|
Key prerequisites |
- An IBM Flex System Enterprise Chassis (7893-92X)
- An operating system ( IBM AIX , IBM i, Red Hat Linux , or SUSE Linux operating systems)
|
Planned availability date |
December 3, 2012, except for features EFD1, EFD2, EFD3, EFD4, EFD5, EFD6, EFD7, and EFD8, which are available December 10, 2012.
|
Description |
IBM Flex System p260 Compute Node
The IBM Flex System p260 Compute Node is the latest high-density Information Technology Element (ITE) server with POWER7+ and EnergyScale technology.
The IBM Flex System p260 Compute Node is a standard-width node with two 4-core, 64-bit, 4.0 GHz POWER7+ processors, or two 8-core, 64-bit, 3.6 GHz or 4.1 GHz POWER7+ processors and 16 DIMM slots, which can contain up to a maximum of 512 GB of memory. Two optional SAS SFF 2.5-inch HDDs or 1.8-inch SATA solid-state drives (SSDs) can be installed in the p260 Compute Node.
Integrated features on the p260 Compute Node include:
- USB 2.0 controller with one front panel port
- SAS controller
- Service processor
- Two PCIe expansion card slots
The IBM Flex System p260 Compute Node can be installed only in the IBM Flex System Enterprise Chassis (7893-92X). The chassis has 14 ITE bays for ITE servers and supports up to 14 standard-width nodes or 7 double-width nodes.
In short-term extended thermal conditions, the p260 Compute Node automatically reduces the frequency of the processor to maintain acceptable thermal or power levels. The processor frequency will automatically cycle back up as thermal or power conditions improve.
Clients should be aware that there may be applications that are sensitive to processor frequency changes. For instance, frequency reductions could potentially impact benchmarking or applications and tools that depend on execution times for accounting, CPU utilization, or profiling. It is recommended that clients check with their individual application vendors to see if there are possible impacts.
IBM Flex System p260 Compute Node features and benefits include:
- Highly efficient and flexible design of the IBM ITE
- Densely pack more servers into a smaller space.
- Tailor the system to meet varied business requirements.
- Integrate networking switch infrastructure for improved cabling and data center maintenance.
- Deploy in virtually any office environment for quieter, highly secure, and contaminant-protected operation.
- Pioneering IBM EnergyScale technology and software, an optional feature available for an additional charge
- Designed to generate less heat by managing application utilization and server energy consumption.
- Designed to use less energy to cool the system.
- Industry-leading PowerVM® virtualization technology
- Potentially reduce infrastructure costs by doing more with fewer servers.
- Simplify IT operations to leverage storage, network, and computing resources to control costs and be more responsive.
- Innovative reliability features and systems management
- Help expedite hardware repairs and reduce service time.
- Enable scheduled maintenance with proactive monitoring of critical system components to help reduce unplanned failures.
- Choice of IBM AIX , IBM i, or Linux operating environment
- Standardize on a single platform that runs the large and varied portfolio of applications that support your business.
IBM PureFlex System
The IBM PureFlex System consists of predefined, preconfigured Flex System components to simplify purchasing and provide the total Flex System integrated value proposition.
The IBM Flex System p260 Compute Node can be ordered as part of a PureFlex System. There are three IBM PureFlex System offerings available:
- IBM PureFlex System Express® for smaller installations (#EFD1)
- IBM PureFlex System Standard for application systems (#EFD2)
- IBM PureFlex System Enterprise scalable cloud deployments; includes redundancy for resilient operation (#EFD3)
A PureFlex System consists of:
A Flex System Compute Node, chosen from:
- Flex System p260 (7895-22X/7895-23X)
- Flex System p460 (7895-42X)
- Flex System x240 (7863-10X)
- Flex System p24L (1457-7FL)
- Flex System x440 (7917-45X)
- Flex System x220 (7906-25X)
Note: IBM PureFlex System Enterprise requires two compute nodes.
- A Flex System Chassis (7893-92X)
- A Flex System Manager (7955-01M)
- A Storwize® V7000 Disk System (2076-124) or an IBM Flex System V7000 Storage Node (4939-A49)
- Two IBM 1455 BNT® Rack Switch G8264R Model 64C (with IBM Flex Enterprise only, with the Flex System p460)
- Two IBM 1455 BNT Rack Switch G8052R Model 48E (with IBM Flex Enterprise only, with the Flex System p460)
- Two IBM 2498 SAN24B-4 Express Model B24 (with IBM Flex Enterprise only, with the Flex System p460)
- An IBM PureFlex System 42U Rack (7953-94X)
Additional Flex System Compute Nodes, Flex System Chassis, Flex System Managers, and IBM PureFlex System 42U Racks can be ordered once the basic requirements for the Flex System are met. These additional orders will be indicated by feature number EFD4 (Expansion Option) along with EFD6, EFD7, or EFD8, or feature number EFD5 (Custom Expansion). Storwize V7000 Disk Systems or IBM Flex System V7000 Storage Nodes can be ordered separately without meeting the requirements for the Flex System.
The maximum number of machine type/models (MTMs) allowed with PureFlex System Express (#EFD1), PureFlex System Standard (#EFD2), PureFlex System Enterprise (#EFD3), and the Expansion Option (#EFD4) are:
Machine type/Model Express Standard Enterprise 7953-94X Rack 2 2 2 7893-92X Chassis 3 3 3 7955-01M FSM 1 1 1 2076-124 Controller 2 2 2 2076-224 Expansion 18 18 18 4939-A49 Controller 9 9 9 4939-A29 Expansion 6 6 6 1455-64C Switch 1 1 2 1455-48E Switch 1 1 2 2498-B24 Switch 1 2 2 Maximum compute nodes with 3 x 7893-92X Chassis: 7895-42X p460 ITE 20 20 20 7895-22X p260 ITE 41 41 41 7895-23X p260 ITE 41 41 41 1457-7FL p24L ITE 41 41 41 7863-10X x240 ITE 41 41 41 7917-45X x440 ITE 20 20 20 7906-25X x220 ITE 41 41 41
Components of the PureFlex System may be separately orderable on a special bid basis from your IBM representative or Business Partner.
Contact your local IBM representative for custom configuration requests.
Information on minimum configurations and options when ordering those products can be found in their online Sales Manuals at
Product Sales Manual IBM Flex System p260 Compute Node 7895-22X/7895-23X IBM Flex System p460 Compute Node 7895-42X IBM Flex System x240 Compute Node 7863-10X IBM Flex System p24L Compute Node 1457-7FL IBM Flex System x440 Compute Node 7917-45X IBM Flex System x220 Compute Node 7906-25X IBM Flex System Enterprise Chassis 7893-92X IBM PureFlex System 42U Rack 7953-94X IBM Storwize V7000 Disk System 2076-124 IBM Flex System V7000 Storage Node 4939-A49 IBM 1455 BNT Rack Switch G8264 1455-64C IBM 1455 BNT Rack Switch G8052 1455-48E IBM 2498 SAN24B-4 Express Model B24 2498-B24
For more information on IBM PureFlex Systems, visit
IBM PureFlex System Express
The IBM PureFlex System Express requirements when ordering the IBM Flex System p260 (7895-23X) Compute Node are:
1 x Flex System p260 Compute Node (7895-23X), with the following features: 1 x #EPRA, #EPRB, or #EPRD Processor Module 8 x #8491 with #EPRD Processor Activations or 16 x #8491 with Processor Activations #EPRA/#EPRB 4 or 8 x #EEMD 64 GB Minimum Memory with EPRD 128 GB Minimum Memory with EPRA/EPRB 1 x #1762 IBM Flex System EN4054 4-port 10Gb Ethernet Adapter 1 x #1764 IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter 1 x #4646 Integrate ITE in Chassis 1 x #4651 Rack indicator, Rack #1 1 x #4681 Chassis specify, Chassis #1 1 x #5005 Software Preinstall 1 x #2145 or #2146 or #2147 Operating System Indicator 1 x #0265 or #0266 or #0267 Partition Specify 1 x #7067 Top Cover, No HDDs or SSDs 8/16 x #5227 PowerVM Standard (per core) 1 x #ED31-#ED3E Installation/User Guide 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD1 or #EFD4/#EFD6 PureFlex System Order Indicator
Note: Features 1762 and 1764 are always required in the configuration. Features EEMD, 5277, and 7067 are minimums and can be replaced. Feature 0566 or 0567 is required with feature 2145.
1 x Flex System Enterprise Chassis (7893-92X), with the following features: 1 x #3593 IBM Flex System EN4093 10Gb Virtual Fabric Scalable Switch 1 x #3595 IBM Flex System FC3171 8Gb SAN Switch or 1 x #3771 IBM Flex System FC5022 16Gb SAN Switch 4 or 6 x #EB29 1000Base-T SFP RJ45 Transceiver 2 x #3282 10 GbE SFP+ Transceiver 2 x #3286 8 GB SFP+ Transceiver (Must be ordered when #3595 and V7000 Disk System (2076-124) are both selected) 2 x #5370 Brocade 8 Gb SFP+ Transceiver (Must be ordered when #3771 and Storwize V7000 Disk System (2076-124) are both selected) 1 x #9039 Base CME 1 x #3592 Redundant CME 2 x #9059 Base Power Module (2X) 2 x #3590 Additional Power Module (2x) 2 x #4558 Power Cord (2.5M) to PDU/UPS 2 x #4560 Power Cord (4.3M), To Wall (208V/16A) 1 x #9038 Base Fans (4X) 1 x #7805 Additional fans (2x) 1 x #4649 Rack Integration Services 1 x #4651 Rack Indicator, Rack #1 2 x #4681 Chassis Specify, Chassis #1 2 x #1111 CAT5E Ethernet Cable, 3M Blue 1 x #ECS3 Integrate p260 in Chassis 1 x #0466 Integrate FSM in Chassis 1 x #ECS2 Integrate Flex System V7000 in Chassis (When 2076-124 is ordered) 1 x #EFM1 Open Fabric Manager 1 x #EPU1-#EPUE System Documentation and Software 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD1 or #EFD4/#EFD6 PureFlex System Order Indicator
Note: Quantity of EB29 required is four when IBM Flex System V7000 Storage Node is selected and six when IBM Storwize V7000 Disk System is selected. Features 3591 and 3771 may not be mixed in the chassis. Feature EFD4 does not require the following features: 0466, 3282, or EB29. Feature EFD4 requires feature 0492.
1 x Flex System Manager (7955-01M), with the following features: 1 x #EB31 Platform Manager S/W Bundle 4 x #EM09 32 GB Memory 2 x #1771 IBM 200 GB 1.8" SATA SSD 1 x #3767 1TB 7.2K RPM 2.5" SATA Disk Drive 1 x #4646 Integrate ITE in Chassis 1 x #4651 Rack Indicator, Rack #1 1 x #4681 Chassis Specify, Chassis #1 1 x #ED11-ED1E System Publications and Media 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD1 or #EFD4/#EFD6 PureFlex System Order Indicator
Note: Either the IBM Flex System V7000 Storage Node (4939-A49) or the Storwize V7000 Disk System (2076-124) must be selected. Both may not be selected.
1 x IBM Flex System V7000 Storage Node (4939-A49), with the following features: 1 x #4646 Integrate ITE in Chassis 1 x #4681 Chassis Specify, Chassis #1 2 x #AD41 or #AD43 200 or 400 GB 2.5-inch SSD 8 x #AD23 or #AD24 600 or 900 GB 2.5-inch HDD or 16 x #AD21 or #AD32 300 GB 10k or 15k 2.5-inch HDD 2 x #ADB2 8 Gb Fibre Channel 4-port Card 1 x #4651 Rack Indicator, Rack #1 1 x #9170 Controller # 1 Group 1 x #AD00 Controller Enclosure 1 x #EFD1 or #EFD4/#EFD6 PureFlex System Order Indicator
Note: Feature AD41 is the default and can be replaced by feature AD43. After meeting the SSD minimum of 2 and HDD minimum of 8 or 16, any SSD or HDD drive can be chosen to a maximum of 24. Feature AD0Z must then be ordered in quantity of 24 minus the total quantity of SSDs and HDDs ordered. Feature EFD4 does not require feature 9170. Feature EFD4 requires feature 9171 or 9172.
1 x Storwize V7000 Disk System (2076-124), with the following features: 1 x #0010 Storage Engine Preload 2 x #5305 5 m Fiber Optic Cable 8 x #3546 or #3549 600 or 900 GB 2.5-inch HDD or 16 x #3543 or #3253 300 GB 10k or 15k 2.5-inch HDD 2 x #6008 Cache 8 GB 1 x #9730 Power Cord - PDU Connection 2 x #9801 AC Power Supply 1 x #4651 Rack Indicator, Rack #1 1 x #EFD0 V7000 Routing Code 1 x #9170 Controller # 1 Group 1 x #EFD1 or #EFD4/#EFD6 PureFlex System Order Indicator
Note: Two pieces of feature 3512 are defaulted on the order but can be removed. Maximum amount of SSDs and HDDs is 24 for the first V7000 controller. Feature EFD4 does not require the following features: 3206, 3512, 3514, or 9170. Feature EFD4 requires feature 9171.
1 x IBM PureFlex System 42U Rack (7953-94X), with the following features: 4 x #4651 Rack Indicator, Rack #1 2 x #7189 or #7196 Optional PDUs 1 x #ER01 Integrate Chassis in Rack 1 x #ER04 Rack Content Specify - 2076-124 (If 2076-124 selected) 1 x #ER1B Reserve 1U empty space - bottom 1 x #ER1T Reserve 1U empty space - top 1 x #EC02 or #EC05 Rack Rear Door or RDHX 1 x #EC03 Side Doors 1 x #EU21 or #EC01 Rack Front Door 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD1 or #EFD4/#EFD6 PureFlex System Order Indicator
Note: Feature EFD4 does not require the following features: ER01, ER03, ER04, 4651, 7189, or 7196. Feature EFD4 requires feature 4652 and either feature EC03 or EC04.
IBM PureFlex System Standard
The IBM PureFlex System Standard requirements when ordering the IBM Flex System p260 Compute Node are:
1 x Flex System p260 Compute Node (7895-23X), with the following features: 1 x #EPRA, #EPRB, or #EPRD Processor Module 8 x #8491 with #EPRD Processor Activations or 16 x #8491 with Processor Activations #EPRA/#EPRB 4 or 8 x #EEMD 64 GB Minimum Memory with EPRD; 128 GB Minimum Memory with EPRA/EPRB 1 x #1762 IBM Flex System EN4054 4-port 10Gb Ethernet Adapter 1 x #1764 IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter 1 x #4646 Integrate ITE in Chassis 1 x #4651 Rack Indicator, Rack #1 1 x #4681 Chassis specify, Chassis #1 1 x #5005 Software Preinstall 1 x #2145 or #2146 or #2147 Operating System Indicator 1 x #0265 or #0266 or #0277 Partition Specify 1 x #7067 Top Cover, No HDDs or SSDs 8/16 x #5228 PowerVM Enterprise (per core) 1 x #ED31-#ED3E Installation/User Guide 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD2 or #EFD4/#EFD7 PureFlex System Order Indicator
Note: Features 1762 and 1764 are always required in the configuration. Features EEMD and 7067 are minimums and can be replaced. Feature 0566 or 0567 is required with feature 2145.
1 x Flex System Enterprise Chassis (7893-92X), with the following features: 1 x #3593 IBM Flex System EN4093 10Gb Virtual Fabric Scalable Switch 2 x #3595 IBM Flex System FC3171 8Gb SAN Switch or 2 x #3771 IBM Flex System FC5022 16Gb SAN Switch 4 or 6 x #EB29 1000Base-T SFP RJ45 Transceiver 4 x #3286 8 Gb SFP+ Transceiver (Must be ordered when #3595 and V7000 Disk System (2076-124) are both selected) 4 x #5370 Brocade 8 Gb SFP+ Transceiver (Must be ordered when #3771 and V7000 Disk System (2076-124) are both selected) 4 x #3282 10 GbE SFP+ Transceiver 1 x #9039 Base CME 1 x #3592 Redundant CME 2 x #9059 Base Power Module (2X) 2 x #3590 Redundant Power Module 4 x #4558 Power Cord (2.5M) to PDU/UPS 4 x #4560 Power Cord (4.3M), To Wall (208V/16A) 1 x #9038 Base Fans (4X) 1 x #7805 Additional Fans (2X) 1 x #4649 Rack Integration Services 1 x #4651 Rack Indicator, Rack #1 2 x #4681 Chassis Specify, Chassis #1 2 x #1111 CAT5E Ethernet Cable, 3M Blue 1 x #ECS3 Integrate p260 in Chassis 1 x #0466 Integrate FSM in Chassis 1 x #ECS2 Integrate Flex System V7000 in Chassis (When 2076-124 is ordered) 1 x #EFM1 Open Fabric Manager 1 x #EPU1-#EPUE System Documentation and Software 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD2 or #EFD4/#EFD7 PureFlex System Order Indicator
Note: Quantity of feature EB29 required is four when IBM Flex System V7000 Storage Node is selected and six when IBM Storwize V7000 Disk System is selected. Features 3591 and 3771 may not be mixed in the chassis. Feature EFD4 does not require the following features: 0466, 3282, or EB29. Feature EFD4 requires feature 0492.
1 x Flex System Manager (7955-01M), with the following features: 1 x #EB31 Platform Manager Software Bundle Indicator 1 x #EB32 Virtualization Manager S/W Bundle Indicator 4 x #EM09 32 GB Memory 2 x #1771 IBM 200 GB 1.8" SATA SSD 1 x #3767 1TB 7.2K RPM 2.5" SATA Disk Drive 1 x #4646 Integrate ITE in Chassis 1 x #4651 Rack Indicator, Rack #1 1 x #4681 Chassis Specify, Chassis #1 1 x #ED11-ED1E System Publications and Media 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD2 or #EFD4/#EFD7 PureFlex System Order Indicator
Note: Either the IBM Flex System V7000 Storage Node (4939-A49) or the Storwize V7000 Disk System (2076-124) must be selected. Both may not be selected.
1 x IBM Flex System V7000 Storage Node (4939-A49), with the following features: 1 x #4646 Integrate ITE in Chassis 1 x #4681 Chassis Specify, Chassis #1 2 x #AD41 or #AD43 200 or 400 GB 2.5-inch SSD 8 x #AD23 or #AD24 600 or 900 GB 2.5-inch HDD or 16 x #AD21 or #AD32 300 GB 10k or 15k 2.5-inch HDD 2 x #ADB2 8 Gb Fibre Channel 4-port Card 1 x #4651 Rack Indicator, Rack #1 1 x #9170 Controller # 1 Group 1 x #AD00 Controller Enclosure 1 x #EFD2 or #EFD4/#EFD7 PureFlex System Order Indicator
Note: Feature AD41 is the default and can be replaced by feature AD43. After meeting the SSD minimum of 2 and HDD minimum of 8 or 16, any SSD or HDD drive can be chosen to a maximum of 24. Feature AD0Z must then be ordered in quantity of 24 minus the total quantity of SSDs and HDDs ordered. Feature EFD4 does not require feature 9170. Feature EFD4 requires feature 9171 or 9172.
1 x Storwize V7000 Disk System (2076-124), with the following features: 1 x #0010 Storwize V7000 S/W Preload 4 x #5305 5m Fiber Optic Cable 2 x #3512 or #3514 200 or 400 GB 2.5-inch SSD 8 x #3546 or #3549 600 or 900 GB 2.5-inch HDD or 16 x #3543 or #3253 300 GB 10k or 15k 2.5-inch HDD 2 x #6008 Cache 8 GB 1 x #9730 Power Cord - PDU Connection 2 x #9801 AC Power Supply 1 x #9170 Controller #1 Group 1 x #4651 Rack Indicator, Rack #1 1 x #EFD0 V7000 Routing Indicator 1 x #EFD2 or #EFD4/#EFD7 PureFlex System Order Indicator
Note: Maximum amount of SSDs and HDDs is 24 for the first V7000 controller. Feature EFD4 does not require the following features: 3206, 3512, 3514, or 9170. Feature EFD4 requires feature 9171.
1 x IBM PureFlex System 42U Rack (7953-94X), with the following features: 4 x #4651 Rack Indicator, Rack #1 2 x #7189 or #7196 Optional PDUs 1 x #ER01 Integrate Chassis in Rack 1 x #ER04 Rack Content Specify - 2076-124 (If 2076-124 selected) 1 x #ER1B Reserve 1U empty space - bottom 1 x #ER1T Reserve 1U empty space - top 1 x #EC02 or #EC05 Rack Rear Door or RDHX 1 x #EC03 Side Doors 1 x #EU21 or #EC21 Rack Front Door 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD2 or #EFD4/#EFD7 PureFlex System Order Indicator
Note: Feature EFD4 does not require the following features: ER01, ER03, ER04, 4651, 7189, or 7196. Feature EFD4 requires feature 4652 and either feature EC03 or EC04.
IBM PureFlex System Enterprise
The IBM PureFlex System Enterprise requirements when ordering the IBM Flex System p260 Compute Node are:
2 x Flex System p260 Compute Node (7895-23X), each with the following features: 1 x #EPRA, #EPRB, or #EPRD Processor Module 8 x #8491 with #EPRD Processor Activations or 16 x #8491 with #EPRA/#EPRD Processor Activations 4 or 8 x #EEMD 64 GB Minimum Memory with EPRD; 128 GB Minimum Memory with EPRA/EPRB 1 x #1762 IBM Flex System EN4054 4-port 10Gb Ethernet Adapter 1 x #1764 IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter 1 x #4646 Integrate ITE in Chassis 1 x #4651 Rack Indicator, Rack #1 1 x #4681 Chassis specify, Chassis #1 1 x #5005 Software Preinstall 1 x #2145 or #2146 or #2147 Operating System Indicator 1 x #0265 or #0266 or #0277 Partition Specify 1 x #7067 Top Cover, No HDDs or SSDs 8/16 x #5228 PowerVM Enterprise (per core) 1 x #ED31-#ED3E Installation/User Guide 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD3 or #EFD4/#EFD8 PureFlex System Order Indicator
Note: Features 1762 and 1764 are always required in the configuration. Features EEMD and 7067 are minimums and can be replaced. Feature 0566 or 0567 is required with feature 2145.
1 x Flex System Enterprise Chassis (7893-92X), with the following features: 2 x #3593 IBM Flex System EN4093 10Gb Virtual Fabric Scalable Switch 2 x #3596 EN4093 Switch Upgrade 1 2 x #3597 EN4093 Switch Upgrade 2 2 x #3595 IBM Flex System FC3171 8Gb SAN Switch or 2 x #3771 IBM Flex System FC5022 16Gb SAN Switch 4 or 6 x #EB29 1000Base-T SFP RJ45 Transceiver 8 x #3286 8 GB SFP+ Transceiver (Must be ordered when #3595 and V7000 Disk System (2076-124) are both selected) 8 x #5370 Brocade 8 Gb SFP+ Transceiver (Must be ordered when #3771 and V7000 Disk System (2076-124) are both selected) 4 x #3282 10 GbE SFP+ Transceiver 1 x #9039 Base CME 1 x #3592 Redundant CME 2 x #9059 Base Power Module (2X) 4 x #3590 Redundant Power Module 6 x #4558 Power Cord (2.5M) to PDU/UPS 6 x #4560 Power Cord (4.3M), To Wall (208V/16A) 1 x #9038 Base Fans (4X) 2 x #7805 Additional Fans (2X) 1 x #4649 Rack Integration Services 1 x #4651 Rack Indicator, Rack #1 3 x #4681 Chassis Specify, Chassis #1 2 x #1111 CAT5E Ethernet Cable, 3M Blue 4 x #ECB4 1m 10 GbE SFP+ DAC Cable 2 x #ECS3 Integrate p260 in Chassis 1 x #0466 Integrate FSM in Chassis 1 x #ECS2 Integrate Flex System V7000 in Chassis (When 2076-124 is ordered) 1 x #EFM1 Open Fabric Manager 1 x #EPU1-#EPUE System Documentation and Software 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD3 or #EFD4/#EFD8 PureFlex System Order Indicator
Note: Quantity of features EB29 required is four when IBM Flex System V7000 Storage Node is selected and six when IBM Storwize V7000 Disk System is selected. Features 3591 and 3771 may not be mixed in the chassis. Feature EFD4 does not require the following features: 0466, 3282, or EB29. Feature EFD4 requires feature 0492.
1 x Flex System Manager (7955-01M), with the following features: 1 x #EB31 Platform Manager Software Bundle Indicator 1 x #EB32 Virtualization Manager S/W Bundle Indicator 4 x #EM09 32 GB Memory 2 x #1771 IBM 200 GB 1.8" SATA SSD 1 x #3767 1TB 7.2K RPM 2.5" SATA Disk Drive 1 x #4646 Integrate ITE in Chassis 1 x #4651 Rack Indicator, Rack #1 1 x #4681 Chassis Specify, Chassis #1 1 x #ED11-ED1E System Publications and Media 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD3 or #EFD4/#EFD8 PureFlex System Order Indicator
Note: Either the IBM Flex System V7000 Storage Node (4939-A49) or the Storwize V7000 Disk System (2076-124) must be selected. Both may not be selected.
1 x IBM Flex System V7000 Storage Node (4939-A49), with the following features: 1 x #4646 Integrate ITE in Chassis 1 x #4681 Chassis Specify, Chassis #1 4 x #AD41 or #AD43 200 or 400 GB 2.5-inch SSD 8 x #AD23 or #AD24 600 or 900 GB 2.5-inch HDD or 16 x #AD21 or #AD32 300 GB 10k or 15k 2.5-inch HDD 2 x #ADB2 8 Gb Fibre Channel 4-port Card 1 x #4651 Rack Indicator, Rack #1 1 x #9170 Controller #1 Group 1 x #AD00 Controller Enclosure 1 x #EFD3 or #EFD4/#EFD8 PureFlex System Order Indicator
Note: Feature AD41 is the default and can be replaced by feature AD43. After meeting the SSD minimum of 4 and HDD maximum of 8 or 16, any SSD or HDD drive can be chosen to a maximum of 24. Feature AD0Z must then be ordered in quantity of 24 minus the total quantity of SSDs and HDDs ordered. Feature EFD4 does not require feature 9170. Feature EFD4 requires feature 9171 or 9172.
1 x Storwize V7000 Disk System (2076-124), with the following features: 1 x #0010 Storwize V7000 S/W Preload 8 x #5305 5m Fiber Optic Cable 2 x #3512 or #3514 200 or 400 GB 2.5-inch SSD 8 x #3546 or #3549 600 or 900 GB 2.5-inch HDD or 16 x #3543 or #3253 300 GB 10k or 15k 2.5-inch HDD 2 x #6008 Cache 8 GB 1 x #9730 Power Cord - PDU Connection 2 x #9801 AC Power Supply 1 x #9170 Controller #1 Group 1 x #4651 Rack Indicator, Rack #1 1 x #EFD0 V7000 Routing Indicator 1 x #EFD3 or #EFD4/#EFD8 PureFlex System Order Indicator
Note: Maximum amount of SSDs and HDDs is 24 for the first V7000 controller. Feature EFD4 does not require the following features: 3206, 3512, 3514, or 9170. Feature EFD4 requires feature 9171.
1 x IBM PureFlex System 42U Rack (7953-94X), with the following features: 5 x #4651 Rack Indicator, Rack #1 2 x #7189 or #7196 Optional PDUs 1 x #ER01 Integrate Chassis in Rack 1 x #ER04 Rack Content Specify - 2076-124 (If 2076-124 selected) 1 x #ER1B Reserve 1U empty space - bottom 1 x #ER1T Reserve 1U empty space - top 1 x #EC02 or #EC05 Rack Rear Door or RDHX 1 x #EC03 Side Doors 1 x #EU21 or #EC01 Rack Front Door 1 x #ESC0 Shipping and Handling (no charge) 1 x #EFD3 or #EFD4/#EFD8 PureFlex System Order Indicator
Note: Feature EFD4 does not require the following features: ER01, ER03, ER04, 4651, 7189, or 7196. Feature EFD4 requires feature 4652 and either feature EC03 or EC04.
PowerVM Editions (Advanced Power Virtualization) (Optional)
The IBM Flex System p260 Compute Node supports PowerVM technology. The p260 is designed to make it more affordable to consolidate multiple independent applications on a single ITE server using the same proven virtualization technologies offered on IBM Power® servers.
The p260 supports two leading-edge virtualization technologies: PowerVM Standard Edition (#5227) and PowerVM Enterprise Edition (#5228).
- PowerVM Standard Edition makes the p260 an ideal platform for consolidation of AIX , Linux , and IBM i operating system applications, designed to help clients reduce infrastructure complexity and cost. Offering an intuitive, web-based interface for managing virtualization within a single compute node, the IVM component of VIOS allows the small business IT manager to quickly and easily set up and manage logical partitions (LPARs). It also enables Virtual I/O and Virtual Ethernet so that storage and communications adapters can be shared among all the LPARs running on the p260. Ultimately, IBM Micro-Partitioning® technology allows each processor core to be subdivided into as many as 10 virtual servers. And because the p260 is built with POWER7+ technology, other advanced virtualization functions such as Shared Dedicated Capacity may be exploited.
- PowerVM Enterprise Edition includes all the features of PowerVM Standard Edition plus a capability called Live Partition Mobility. Live Partition Mobility allows for the movement of a running AIX or Linux partition from one POWER6® , POWER7 or POWER7+ processor-based server to another. Designed to have no application downtime, Live Partition Mobility could result in better system utilization, improved application availability, and potential energy savings. With Live Partition Mobility, planned application downtime due to regular server maintenance can be a thing of the past. Software Maintenance for Virtual I/O Server (577x-PVE) must be purchased with VIOS (5765-PVE). PowerVM Enterprise Edition must be purchased separately.
Capacity Backup (CBU) Support for IBM i on the IBM Flex System p260 Compute Node
The CBU designation can help meet your requirements for use of a second system as backup, high availability, and disaster recovery. It enables you to temporarily transfer IBM i processor entitlements and IBM i user entitlements purchased for a primary machine to a secondary CBU system. Temporarily transferring these resources, instead of purchasing them for a secondary system, may result in significant savings.
The CBU specify feature number 4898 for the IBM Flex System p260 Compute Node (7895-23X) is available as part of a new compute node purchase. This CBU feature cannot be added to an existing compute node.
Certain system prerequisites must be met, and system registration and approval is required before the CBU specify feature can be applied on a new server.
Standard IBM i terms and conditions do not allow either IBM i processor entitlements or IBM i user entitlements to be transferred permanently or temporarily. These entitlements remain with the machine for which they were ordered. When you register the association between a primary and on-order CBU system, you must agree to certain terms and conditions regarding the temporary transfer. After a CBU system designation is approved and the system is installed, you can temporarily move your optional IBM i processor entitlement and user entitlements from the primary system to the CBU system for any purpose, provided the corresponding primary system processors are not being used concurrently for production purposes. The CBU system can therefore better support failover and role swapping for a full range of test, disaster recovery, and high availability scenarios. Temporary entitlement transfer means that the entitlement is a property transferred from the primary system to the CBU system, and may remain in use on the CBU as long as the registered primary and CBU systems are in deployment for the high availability or disaster recovery operation.
Primary System Capacity Backup System (Processor Group) (Processor Group) JS23/JS43 (P10) PS701/PS702 (P10), PS700 (P05) JS23/JS43 (P10) PS701/PS702 (P10), PS700 (P05) JS22 (P10) PS701/PS702 (P10), PS700 (P05) JS23/JS43 (P10) PS700 (P05) PS701/PS702 (P10) PS701/PS702 (P10), PS700 (P05) PS701/PS702 (P10) PS700 (P05) PS701/PS702 (P10) PS700 (P05) PS700 (P05) PS700 (P05) PS703 (P10) PS703 (P10) PS704 (P10) PS703 (P10), PS704 (P10) PS704 (P10) PS700 (P05) PS704 (P10) PS700 (P05) P260 (P10) P703 (P10), P704(P10), P260(P10), P460 (P10) P460 (P10) P703 (P10), P704(P10), P260(P10), P460 (P10)
These systems have IBM i software licenses with an IBM i P05 or P10 processor group. The primary machine must be in the same enterprise and country as the CBU system.
Before you can temporarily transfer IBM i processor entitlements from the registered primary system, you must have more than one IBM i processor entitlement on the primary machine and at least one IBM i processor entitlement on the CBU server. You can then transfer any IBM i processor entitlements above the minimum one, assuming the total IBM i workload on the primary system does not require the IBM i entitlement that you want to transfer during the time of the transfer. During this temporary transfer, the CBU system's internal records of its total number of IBM i processor entitlements are not updated, and you may see IBM i license noncompliance warning messages from the CBU system. These warning messages in this situation do not mean you are not in compliance.
The p260 high availability options include PowerHA® with Geographic Mirroring. You may also use Metro Mirror or Global Mirror replication solutions provided by the storage subsystem, and other third-party software replication packages.
Before you can temporarily transfer IBM i user entitlements, you must have more than five IBM i user entitlements on the p260 primary server and at least five IBM user entitlements on the CBU server. You can transfer optional entitlements (any IBM i user entitlements above the minimum five) from the primary to the CBU. The user entitlements transferred to the CBU may not be used concurrently on the primary server from which they were transferred. If the primary server is of a P10 processor group, then the primary server must have a minimum of 10 user entitlements and the optional user entitlements (those over the 10 required) may be transferred temporarily to the CBU. As a general principle of the CBU on i offering, temporary entitlement transfer cannot originate on the CBU.
For example, if you have a p260 as your primary system with two IBM i processor entitlements (one above the minimum) and 50 IBM i user entitlements (40 above the minimum), you can temporarily transfer up to one IBM i processor entitlement and up to 40 user entitlements. During this temporary transfer, the CBU system's internal records of its total number of IBM i processor and user entitlements are not updated, and you may see IBM i license noncompliance warning messages from the CBU system.
If your primary or CBU machine is sold or discontinued from use, any temporary entitlement transfers must be returned to the machine on which they were originally acquired.
For CBU registration and further details, visit
N_Port ID Virtualization - NPIV
NPIV provides direct access to Fibre Channel adapters from multiple client partitions, simplifying the management of Fibre Channel SAN environments. NPIV support is included with PowerVM Standard and Enterprise Editions.
Systems Management and Administrative Tools
Integrated diagnostic and administrative tools like IBM Predicative Failure Analysis and light path diagnostics are designed to simplify administration to help lower costs and improve control of the IT environment. Remote management capabilities allow automating IT networking tasks.
Proven technology like VIOS allows the sharing of disk drives, communications, and Fibre Channel adapters.
Systems management support for IBM Flex System p260 Compute Node
The compute node supports the IBM Flex System Manager management software and IBM Flex System Chassis Management Module (CMM).
- IBM Flex System Manager management software is a platform-management foundation that streamlines the way you manage physical and virtual systems in a heterogeneous environment. By using industry standards, IBM Flex System Manager management software supports multiple operating systems and virtualization technologies.
- CMM is a hot-swap module that provides system management functions for all components in an IBM Flex System chassis. It controls a serial port for remote connection and a 10/100 Mbps Ethernet remote-management connection.
IBM Flex System p260 Compute Node highlights
Note: Minimum requirements are for EFD5 (Custom Expansion) only.
- Form factor
The IBM Flex System p260 Compute Node is a standard-width node for the IBM Flex System Enterprise Chassis.
- Processor cores
The p260 contains either two 4-core 64-bit 4.0 GHz or two 8-core 3.6 GHz or 4.1 GHz POWER7+ processors.
- Level 2 (L2) cache
256 KB per processor core
- Level 3 (L3) cache
4 MB per processor core
- Memory (standard and maximum)
Base offering: 16 GB. Up to 512 GB maximum in 16 DIMM slots. ECC and Chipkill DDR3 SDRAM memory running at 1066 MHz.
Note: Maximum of 128 GB with HDDs installed. - Internal drive storage maximums (optional)
- Two 300 GB, 600 GB, or 900 GB 2.5-inch Serial Attached SCSI (SAS) 10,000 RPM non-hot-swappable HDDs
- Two 177 GB 1.8-inch SATA SSDs
- Integrated RAID 0 or RAID 1 standard on ITE with support for disk mirroring
- I/O
Two PCIe slots available.
- Optional connectivity
- IBM Flex System IB6132 2-port QDR InfiniBand Adapter (#1761)
- IBM Flex System EN4054 4-port 10Gb Ethernet Adapter (#1762)
- IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter (#1764)
- IBM Flex System EN2024 4-port 1Gb Ethernet Adapter (#1763)
- IBM Flex System CN4058 8-port 10Gb Converged Adapter (#EC24)
- IBM Flex System EN4132 2-port 10Gb RoCE Adapter (#EC26)
- PowerVM Standard Edition
Virtual LAN, POWER Hypervisor , Micro-Partitioning , Virtual I/O Server with Integrated Virtualization Manager, Shared Dedicated Capacity, and PowerVM Lx86
- PowerVM Enterprise Edition (optional, when running AIX or Linux )
All the features of PowerVM Standard Edition plus Live Partition Mobility and Active Memory Sharing
- Systems management
Integrated systems management processor, light path diagnostics, Predictive Failure Analysis, Cluster Systems Management for AIX (CSM), Serial Over LAN, and IPMI-compliant
- RAS features
- IBM Chipkill ECC detection and correction
- Processor Instruction Retry
- Service processor with fault monitoring
- Hot-plug power supplies and cooling fans (on chassis)
- Dynamic processor deallocation
- Dynamic deallocation of logical partitions and PCIe bus slots
- Extended error handling on PCIe slots
- Redundant power supplies and cooling fans (on chassis)
- High availability
- IBM PowerHA family
Support for IBM i 6.1 and IBM i 7.1
Support for IBM Flex System p260 Compute Node:
IBM i 6.1 and IBM i 7.1 support the IBM Flex System p260 Compute Node. For IBM i, the p260 ITE server is supported in the IBM Flex System Enterprise Chassis. The p260 also supports AIX and Linux operating systems.
IBM i uses the PowerVM VIOS partition for access to Flex System resources and storage devices. The VIOS partition owns adapters on the compute node and virtualizes the resources to the IBM i partition.
IBM i operating system supports the following I/O adapters and storage options on the p260:
- IBM Flex System EN4054 4-port 10Gb Ethernet Adapter (#1762)
- IBM Flex System EN2024 4-port 1Gb Ethernet Adapter (#1763)
- IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter (#1764)
- IBM Flex System CN4058 8-port 10Gb Converged Adapter (#EC24)
- IBM 300 GB SAS 10K SFF HDD (#8274)
- IBM 600 GB SAS 10K SFF HDD (#8276)
- IBM 900 GB SAS 10K SFF HDD (#8311)
- IBM 177 GB SATA SSD (#8207)
For use with IBM i, the compute node can be deployed with one VIOS partition and one IBM i partition, with one VIOS partition and multiple IBM i partitions, or with one VIOS partition and a combination of IBM i, AIX , and Linux partitions.
IBM i 6.1 (5761-SS1) and IBM i 7.1 (5770-SS1) include per processor core and per user entitlements for compute nodes.
|
Product positioning |
IBM PureFlex System suits multiple delivery models, from highly customizable hardware platforms to a fully integrated and optimized system:
- IBM PureFlex System hardware "building blocks" made up of individual components that can be mixed and matched, and are fully customizable with optional management
- IBM PureFlex System solutions made up of chassis with integrated management appliance, IBM networking, and storage standard
- IBM PureFlex System optimized offerings made up of preconfigured, highly customized systems, focused on selected workloads or single-purpose applications such as IBM PureFlex System
|
Statement of general direction |
IBM intends to provide to those clients with AIX 5.3 Technology Level 12 (and the associated service extension offering) the ability to run that environment on the IBM Flex System p260 Compute Nodes (7895-23X).
For IBM PureFlex Systems with Power compute nodes, IBM intends to update IBM Flex System Manager by providing capabilities for Qbg.
IBM's statements regarding its plans, directions, and intent are subject to change or withdrawal without notice at IBM's sole discretion. Information regarding potential future products is intended to outline our general product direction and it should not be relied on in making a purchasing decision. The information mentioned regarding potential future products is not a commitment, promise, or legal obligation to deliver any material, code, or functionality. Information about potential future products may not be incorporated into any contract. The development, release, and timing of any future features or functionality described for our products remains at our sole discretion.
|
Reference information |
Refer to Hardware Announcement 112-017, dated April 11, 2012 .
Refer to Hardware Announcement 112-018, dated April 11, 2012 .
Refer to Hardware Announcement 112-080, dated April 11, 2012 .
|
Product number |
The following are newly announced features on the specific models of the IBM Power Systems 7895 machine type:
Machine Feature Description type Model number
IBM Power Systems 7895 7895 23X Linux Software Preinstall 7895 23X 8143 Linux Software Preinstall (Business Partners) 7895 23X 8144 AIX/VIOS Software Preinstall 7895 23X 8146 AIX/VIOS Software Preinstall (Business Partners) 7895 23X 8147 IBM Flex System CN4058 8-port 10Gb Converged Adapter 7895 23X EC24 IBM Flex System EN4132 2-port 10Gb RoCE Adapter 7895 23X EC26 System Guides - English 7895 23X ED31 System Guides - UK English 7895 23X ED32 System Guides - Brazilian Portuguese 7895 23X ED33 System Guides - Japanese 7895 23X ED34 System Guides - Japanese English 7895 23X ED35 System Guides - Korean 7895 23X ED36 System Guides - Korean English 7895 23X ED37 System Guides - Chinese English 7895 23X ED38 System Guides - Chinese Hong Kong 7895 23X ED39 System Guides - Chinese Taiwan 7895 23X ED3A System Guides - French 7895 23X ED3B System Guides - Spanish 7895 23X ED3C System Guides - German 7895 23X ED3D System Guides - Italian 7895 23X ED3E 64GB (2 x 32GB RDIMMs) 4Gb DDR3 1066 MHz System Memory 7895 23X EEMF IBM PureFlex System Express Expansion Indicator 7895 23X EFD6 IBM PureFlex System Standard Expansion Indicator 7895 23X EFD7 IBM PureFlex System Enterprise Expansion Indicator 7895 23X EFD8 Build-To-Order Indicator 7895 23X EFD9 16-core 4.1 GHz POWER7+ Processor Module 7895 23X EPRA 16-core 3.6 GHz POWER7+ Processor Module 7895 23X EPRB 8-core 4.0 GHz POWER7+ Processor Module 7895 23X EPRD RDX USB External Docking Station for Removable Disk Cartridge 7895 23X EU04
The following are features already announced for the IBM Power Systems 7895 machine type:
Machine Feature Description type Model number
One CSC Billing Unit 7895 23X 0010 Ten CSC Billing Units 7895 23X 0011 AIX Partition Specify 7895 23X 0265 Linux Partition Specify 7895 23X 0266 IBM i Operating System Partition Specify 7895 23X 0267 IBM i 6.1 with 6.1.1 Machine Code Specify Code 7895 23X 0566 IBM i 7.1 Specify Code 7895 23X 0567 US TAA Compliance Indicator 7895 23X 0983 USB External Docking Station for Removable Disk Drive 7895 23X 1104 USB 500 GB Removable Disk Drive 7895 23X 1107 Custom Service Specify, Rochester Minn, USA 7895 23X 1140 IBM Flex System IB6132 2-port QDR InfiniBand Adapter 7895 23X 1761 IBM Flex System EN4054 4-port 10Gb Ethernet Adapter 7895 23X 1762 IBM Flex System EN2024 4-port 1Gb Ethernet Adapter 7895 23X 1763 IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter 7895 23X 1764 Primary OS - IBM i 7895 23X 2145 Primary OS - AIX 7895 23X 2146 Primary OS - Linux 7895 23X 2147 Factory Deconfiguration of 1-core 7895 23X 2319 Integrate Blade Server in Chassis (BP) 7895 23X 4645 Integrate ITE in Chassis 7895 23X 4646 One and only one rack indicator feature is required on all orders (#4650 to #4666). Rack Indicator- Not Factory Integrated 7895 23X 4650 Rack Indicator, Rack #1 7895 23X 4651 Rack Indicator, Rack #2 7895 23X 4652 Rack Indicator, Rack #3 7895 23X 4653 Rack Indicator, Rack #4 7895 23X 4654 Rack Indicator, Rack #5 7895 23X 4655 Rack Indicator, Rack #6 7895 23X 4656 Rack Indicator, Rack #7 7895 23X 4657 Rack Indicator, Rack #8 7895 23X 4658 Rack Indicator, Rack #9 7895 23X 4659 Rack Indicator, Rack #10 7895 23X 4660 Rack Indicator, Rack #11 7895 23X 4661 Rack Indicator, Rack #12 7895 23X 4662 Rack Indicator, Rack #13 7895 23X 4663 Rack Indicator, Rack #14 7895 23X 4664 Rack Indicator, Rack #15 7895 23X 4665 Rack Indicator, Rack #16 7895 23X 4666 Chassis indicator-Not Factory Integrated 7895 23X 4680 Chassis specify, Chassis #1 7895 23X 4681 Chassis specify, Chassis #2 7895 23X 4682 Chassis specify, Chassis #3 7895 23X 4683 Chassis specify, Chassis #4 7895 23X 4684 Chassis specify, Chassis #5 7895 23X 4685 Chassis specify, Chassis #6 7895 23X 4686 Chassis specify, Chassis #7 7895 23X 4687 Chassis specify, Chassis #8 7895 23X 4688 Chassis specify, Chassis #9 7895 23X 4689 IBM i CBU Specify Code 7895 23X 4898 Software Preinstall 7895 23X 5005 PowerVM Standard Edition 7895 23X 5227 PowerVM Enterprise Edition 7895 23X 5228 Top Cover, Diskless Model 7895 23X 7067 Top Cover, SSDs Installed 7895 23X 7068 Top Cover, HDDs Installed 7895 23X 7069 8GB (2x4GB RDIMMs) DDR3 1066 MHz System Memory 7895 23X 8196 177 GB 1.8" SATA Solid State Drive 7895 23X 8207 300 GB SAS 10K RPM SFF HDD 7895 23X 8274 600 GB SAS 10K RPM SFF HDD 7895 23X 8276 900 GB SAS 10K RPM SFF HDD 7895 23X 8311 One Processor Entitlement 7895 23X 8491 Order Routing Indicator- System Plant 7895 23X 9169 New AIX License Core Counter 7895 23X 9440 New IBM i License Core Counter 7895 23X 9441 New Red Hat License Core Counter 7895 23X 9442 New SUSE License Core Counter 7895 23X 9443 Other AIX License Core Counter 7895 23X 9444 Other Linux License Core Counter 7895 23X 9445 3rd Party Linux License Core Counter 7895 23X 9446 VIOS Core Counter 7895 23X 9447 Month Indicator 7895 23X 9461 Day Indicator 7895 23X 9462 Hour Indicator 7895 23X 9463 Minute Indicator 7895 23X 9464 Qty Indicator 7895 23X 9465 Countable Member Indicator 7895 23X 9466 16GB (2 x 8GB RDIMMs) 4Gb DDR3 1066 MHz System Memory 7895 23X EEMD 32GB (2 x 16GB RDIMMs) 4Gb DDR3 1066 MHz System Memory 7895 23X EEME IBM PureFlex System Express Indicator 7895 23X EFD1 IBM PureFlex System Standard Indicator 7895 23X EFD2 IBM PureFlex System Enterprise Indicator 7895 23X EFD3 IBM PureFlex System Expansion Indicator 7895 23X EFD4 IBM PureFlex System Custom Configuration Indicator 7895 23X EFD5 Trial PowerVM Live Partition Mobility 7895 23X ELPM RFID Tags for Servers, Compute Nodes, Chassis, Racks, and HMCs 7895 23X ERF1 S&H - No Charge 7895 23X ESC0 S&H 7895 23X ESC4 1TB Removable Disk Drive Cartridge 7895 23X EU01 RDX 320 GB Removable Disk Drive 7895 23X EU08
Feature conversions
The existing components being replaced during a model or feature conversion become the property of IBM and must be returned.
Feature conversions are always implemented on a "quantity of one for quantity of one" basis. Multiple existing features may not be converted to a single new feature. Single existing features may not be converted to multiple new features.
The following conversions are available to customers:
Feature conversions for 7895-23X virtualization engine features
Return From FC: To FC: parts
5227 - PowerVM Standard 5228 - PowerVM Enterprise No Edition Edition
Business Partner information
If you are a Direct Reseller - System Reseller acquiring products from IBM , you may link directly to Business Partner information for this announcement. A PartnerWorld® ID and password are required (use IBM ID).
Reliability, Availability, and Serviceability (RAS)
The reliability of the IBM Flex System p260 Compute Node (7895-23X) starts with components, devices, and subsystems that are designed to be fault-tolerant. POWER7+ uses lower voltage technology in the processor SCMs that improves reliability and stacked latches to reduce soft error (SER) susceptibility. During the design and development process, subsystems go through rigorous verification and integration testing processes. During system manufacturing, systems go through a thorough testing process to help ensure high product quality levels.
The processor and memory subsystem contains a number of features designed to avoid or correct environmentally induced, single-bit, intermittent failures as well as handle solid faults in components, including selective redundancy to tolerate certain faults without requiring an outage or parts replacement.
|
Publications |
No publications are shipped with the announced product.
The IBM Systems Information Center provides you with a single information center where you can access product documentation for IBM systems hardware, operating systems, and server software. Through a consistent framework, you can efficiently find information and personalize your access. The IBM Systems Information Center is at
|
Services |
Global Technology Services
IBM services include business consulting, outsourcing, hosting services, applications, and other technology management.
These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an On Demand Business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-IBM offerings. IBM is your one-stop shop for IT support needs.
For details on available services, contact your IBM representative or visit
For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or visit
For details on education offerings related to specific products, visit
Select your country, and then select the product as the category.
|
Technical information |
Specified operating environment
Physical specifications
- IBM Flex System p260 Compute Node (7895-23X)
- Height: 55.9 mm (2.2 in)
- Width: 218.4 mm (8.6 in)
- Depth: 492.7 mm (19.4 in)
- Weight: 7.7 kg (17.0 lb)
- IBM Flex System Enterprise Chassis (7893-92X)
- Height: 440 mm (17.5 in)
- Width: 447 mm (17.6 in)
- Depth: 800 mm (31.5 in)
- Weight: 159 kg (350 lb)
To assure installability and serviceability in non-IBM industry-standard racks, review the installation planning information for any product-specific installation requirements.
Operating environment
- Temperature:
- 10° to 35°C (50° to 95°F) at 0 to 914 m (0 to 3,000 ft)
- 10° to 32°C (50° to 90°F) at 914 to 2,133 m (3,000 to 7,000 ft)
- Relative humidity: 8% to 80%
- Maximum altitude: 2,133 m (7,000 ft)
- Power consumption (@ +12 V supplied by Flex System Enterprise Chassis): 634 watts maximum
Note: The maximum measured value is the worst case power consumption expected from a fully populated server under an intensive workload. The maximum measured value also accounts for component tolerance and non-ideal operating conditions. Power consumption and heat load vary greatly by server configuration and utilization. The IBM Systems Energy Estimator should be used to obtain a heat output estimate based on a specific configuration.
EMC conformance
- US: FCC - Verified to comply with Part 15 of the FCC Rules Class A
- Canada: ICES-004, issue 3 Class A
- EMEA: EN55022: 2006 + A1:2007 Class A
- EMEA: EN55024: 1998 + A1:2001 + A2:2003
- Australia and New Zealand: CISPR 22, Class A
Safety certifications
- US: (UL Mark) UL 60950-1 1st Edition
- CAN: (cUL Mark) CAN/CSA22.2 No.60950-1 1st Edition
- Europe: EN 60950-1:2006+A11:2009
- CB: IEC60950-1, 2nd Edition
- Russia: (GOST Mark) IEC60950-1
Hardware requirements
IBM Flex System p260 Compute Node:
L3 7895-23X Processor Cache Memory Local Storage 8-core 4.0/ 4 MB/ 16 GB - Two optional 2.5" 16-core 3.6/ core 512 GB HDDs or 1.8" SSDs 16-core 4.1 GHz POWER7+
Minimum system configuration
The IBM Flex System p260 Compute Node can be ordered as a Custom Expansion (#EFD5) order.
Each Custom Expansion 7895-23X configuration must contain a minimum of:
- One processor chosen from:
- 8-core (2 x 4-core) 4.0 GHz 2-socket planar (#EPRD)
- 16-core (2 x 8-core) 3.6 GHz 2-socket planar (#EPRA)
- 16-core (2 x 8-core) 4.1 GHz 2-socket planar (#EPRB)
- Eight or sixteen Processor Entitlements (one of these):
- 8 x #8491 with #EPRD
- 16 x #8491 with #EPRA and #EPRB
- 16 GB memory chosen from:
- 8 GB (2 x 4 GB DIMMs) DDR3 1066 MHz (#8196)
- 16 GB (2 x 8 GB DIMMs) DDR3 1066 MHz (#EEMD)
- 32 GB (2 x 16 GB DIMMs) DDR3 1066 MHz (#EEME)
- 64 GB (2 x 32 GB DIMMs) DDR3 1066 MHz (#EEMF)
Note: If HDDs are installed, features EEME and EEMF are not allowed. - One Ethernet adapter, chosen from:
- IBM Flex System EN4054 4-port 10Gb Ethernet Adapter (#1762)
- IBM Flex System EN2024 4-port 1Gb Ethernet Adapter (#1763)
- IBM Flex System CN4058 8-port 10Gb Converged Adapter (#EC24)
- PowerVM Standard Edition (#5227) or PowerVM Enterprise Edition (#5228)
- One top cover, chosen from:
- No HDDs or SSDs installed (#7067)
- SSDs (#8207, or follow-on) installed (#7068)
- HDDs (#8274/#8276/#8311, or follow-on) installed (#7069)
- One Primary Operating System Indicator, chosen from:
- IBM i (#2145 -- requires #0565 or #0566)
- AIX (#2146)
- Linux (2147)
- 1 x #ESC0 Shipping and Handling (no charge)
- 1 x #EFD5 PureFlex System Order Indicator
Note: A minimum of one copy of the IBM Flex System p260/p460 Compute Node Installation/User Guide (ED31-ED3E) is required at each customer installation.
Optional and additional features
- Up to 512 GB of system memory
- A maximum of eight memory features (16 DIMMs) may be installed in the 7895-23X.
- If an HDD is installed in the 7895-23X, then only 8 GB (#8196) or 16 GB (#EEMD) memory features are allowed.
- Minimum memory with an SSD or no SSD/HDD installed is 16 GB with a maximum of 512 GB. Minimum memory with an HDD installed is 16 GB with a maximum of 128 GB.
- Memory DIMMs must be installed in matched pairs (same size and speed) but memory features may be mixed.
- The p260 supports Memory Scrubbing, ECC, and Chipkill.
- Memory features operate at 1066 MHz.
- Storage devices
- The p260 does not support removable media within the compute node.
- The p260 has two locations for installation of one or two optional 2.5-inch SAS SFF HDDs.
- The p260 has two locations for installation of one or two optional 1.8-inch SATA SSDs.
- SSDs and HDDs may not be mixed in the p260.
Expansion cards
The IBM Flex System p260 Compute Node has two slots supporting the following PCIe expansion cards:
- IBM Flex System IB6132 2-port QDR InfiniBand Adapter (#1761)
- IBM Flex System EN4054 4-port 10Gb Ethernet Adapter (#1762)
- IBM Flex System EN2024 4-port 1Gb Ethernet Adapter (#1763)
- IBM Flex System FC3172 2-port 8Gb FC Adapter (#1764)
- IBM Flex System CN4058 8-port 10Gb Converged Adapter (#EC24)
- IBM Flex System EN4132 2-port 10Gb RoCE Adapter (#EC26)
A maximum of 1 x #EC26, #1761, or #1764 is allowed.
A maximum of 2 x #EC24, #1762, or #1763 is allowed.
Software requirements
The IBM Flex System p260 Compute Node server supports the AIX , Linux , and IBM i operating systems, providing the flexibility of using applications written for any one of the three. IBM has qualified two popular Linux distributions for use with the p260:
- Red Hat Enterprise Linux for POWER®
- SUSE Linux Enterprise Server for POWER
One or more of the following operating systems is required for an operational IBM Flex System p260 Compute Node:
If installing the AIX operating system (one of these):
- AIX V7.1 with the 7100-02 Technology Level, or later
- AIX V6.1 with the 6100-08 Technology Level, or later
If installing the IBM i operating system:
- IBM i 6.1 with i 6.1.1 machine code, or later
- IBM i 7.1, or later
For more detailed information about IBM i support for this announcement, refer to the IBM i Technology Updates at
Note: VIOS is required with the IBM i operating system.
If installing VIOS:
- VIOS 2.2.2.0
If installing the Linux operating system (one of these):
- SUSE Linux Enterprise Server 11 Service Pack 2 for POWER , with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux for POWER 6.3, or later
Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
Note: For systems ordered with the Linux operating system, IBM ships the most current versions available from the distributor. If your hardware requires a different version of a Linux OS than that shipped by IBM , you must obtain it by downloading it from the Linux distributor's website. Information concerning access to a distributor's website is located on the product registration card delivered to you as part of your Linux OS order.
Processor is the unit of measure by which this program is licensed. A processor (commonly called a processor core or CPU ) is a functional unit within a computing device that interprets and executes instructions. A processor consists of at least an instruction control unit and one or more arithmetic or logic units. With multicore technology, each core is considered a processor. For programs eligible for sub-capacity licensing, a Proof of Entitlement (PoE) must be acquired for all activated processors available for use in each partition (utilizing eligible partitioning technologies) where the program runs. A PoE must be acquired for all activated processor cores available for use on the server.
Limitations
Solid state memory cells have an intrinsic, finite number of write cycles that each cell can incur. As a result, each solid-state device has a maximum amount of write cycles it can be subjected to, documented as TBW (Total Bytes Written). IBM is not responsible for replacement of hardware that has reached the maximum guaranteed number of write cycles. This limit may be revealed as the device failing to communicate to system generated commands or become incapable of being written to.
Planning information
Cable orders
No cables are required.
Security, auditability, and control
Security and auditability features include:
- A power-on password function provides control of who has access to the data and server setup program on the server.
- A selectable boot sequence can be used to prevent unauthorized installation of software or removal of data from the diskette drive.
Limitations: The IBM Flex System Enterprise Chassis and the IBM Flex System p260 Compute Node have no security-intrusion detection.
The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.
|
IBM Electronic Services |
IBM has transformed its delivery of hardware and software support services to help you achieve higher system availability. Electronic Services is a Web-enabled solution that offers an exclusive, no-additional-charge enhancement to the service and support available for IBM servers. These services are designed to provide the opportunity for greater system availability with faster problem resolution and preemptive monitoring. Electronic Services comprises two separate, but complementary, elements: Electronic Services news page and Electronic Services Agent.
The Electronic Services news page is a single Internet entry point that replaces the multiple entry points traditionally used to access IBM Internet services and support. The news page enables you to gain easier access to IBM resources for assistance in resolving technical problems.
The Electronic Service Agent is no-additional-charge software that resides on your server. It monitors events and transmits system inventory information to IBM on a periodic, client-defined timetable. The Electronic Service Agent automatically reports hardware problems to IBM . Early knowledge about potential problems enables IBM to deliver proactive service that may result in higher system availability and performance. In addition, information collected through the Service Agent is made available to IBM service support representatives when they help answer your questions or diagnose problems. Installation and use of IBM Electronic Service Agent for problem reporting enables IBM to provide better support and service for your IBM server.
To learn how Electronic Services can work for you, visit
|
Terms and conditions |
Volume orders: Contact your IBM representative.
IBM Global Financing
Yes
Warranty period
Three years.
Note: For configurations that support the RAID Battery, the RAID battery will be warranted for one year effective on its "Date of Installation." All other product warranty terms for the machine remain unchanged.
An IBM part or feature installed during the initial installation of an IBM machine is subject to a full warranty effective on the date of installation of the machine. An IBM part or feature that replaces a previously installed part or feature assumes the remainder of the warranty period for the replaced part or feature. An IBM part or feature added to a machine without replacing a previously installed part or feature is subject to a full warranty effective on its date of installation. Unless specified otherwise, the warranty period, type of warranty service, and service level of a part or feature are the same as those for the machine in which it is installed.
Warranty services
If required, IBM provides repair or exchange service depending on the types of warranty service specified for the machine. IBM will attempt to resolve your problem over the telephone, or electronically via an IBM website. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability. If applicable to your product, parts considered Customer Replaceable Units (CRUs) will be provided as part of the machine's standard warranty service.
Service levels are response-time objectives and are not guaranteed. The specified level of warranty service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country- and location-specific information.
CRU Service
IBM provides replacement CRUs to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request. CRUs are designated as being either a Tier 1 or a Tier 2 CRU.
Tier 1 CRU
Installation of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation.
Tier 2 CRU
You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge.
Based upon availability, CRUs will be shipped for next business day (NBD) delivery. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM . When return is required, return instructions and a container are shipped with the replacement CRU, you may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.
The following parts have been designated as Tier 1 CRUs:
- Hard disk drive
- Hard disk drive flex cable
- Hard disk drive interposer
- Mezzanine cards
- Battery
- Bezel
- Memory DIMMs
- Top cover
- Management card
On-site Service
IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.
The service level is:
- 9 hours per day, Monday through Friday, excluding holidays, next business day response. Calls must be received by 5 p.m. local time in order to qualify for next-business-day response.
Non-IBM parts service
IBM is now shipping machines with selected non-IBM parts that contain an IBM field replaceable unit (FRU) part number label. These parts are to be serviced during the IBM machine warranty period. IBM is covering the service on these selected non-IBM parts as an accommodation to their customers, and normal warranty service procedures for the IBM machine apply.
International warranty service
International Warranty Service (IWS) is available in selected countries or regions.
The warranty service type and the service level provided in the servicing country may be different from that provided in the country in which the machine was purchased.
Under IWS, warranty service will be provided with the prevailing warranty service type and service level available for the IWS-eligible machine type in the servicing country and the warranty period observed will be that of the country in which the machine was purchased.
To determine the eligibility of your machine and to view a list of countries where service is available, visit
For more information on IWS, refer to Services Announcement 601-034, dated September 25, 2001 .
Warranty service upgrades
During the warranty period, a warranty service upgrades provides an enhanced level of On-site Service for an additional charge. A warranty service upgrade must be purchased during the warranty period and is for a fixed term (duration). It is not refundable or transferable and may not be prorated. If required, IBM will provide the warranty service upgrade enhanced level of On-site Service acquired by the customer. Service levels are response-time objectives and are not guaranteed. See the Warranty services section for additional details.
IBM will attempt to resolve your problem over the telephone or electronically by access to an IBM website. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability.
CRUs will be provided as part of the machine's standard warranty CRU Service except that you may install a Tier 1 CRU yourself or request IBM installation, at no additional charge, under one of the On-site Service levels specified below. For additional information on the CRU Service, see the warranty information.
On-site Service:
IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.
The service level is:
- 9 hours per day, Monday through Friday, excluding holidays, 4-hour average response, same-business-day response.
- 24 hours per day, 7 days a week, 4-hour average response
- 24 hours per day, 7 days a week, 2-hour average response
Note: Canada does not offer 2-hour response option.
Customer Replaceable Units (CRUs) may be provided as part of the machine's standard warranty CRU Service except that you may install a CRU yourself or request IBM installation, at no additional charge, under one of the On-site service levels specified above. For additional information on the CRU service, see warranty information.
Maintenance services
If required, IBM provides repair or exchange service depending on the types of maintenance service specified for the machine. IBM will attempt to resolve your problem over the telephone or electronically, via an IBM website. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability. Service levels are response-time objectives and are not guaranteed. The specified level of maintenance service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country-specific and location-specific information. The following service selections are available as maintenance options for your machine type.
On-site Service
IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.
The service level is:
- 9 hours per day, Monday through Friday, excluding holidays, next-business-day response.
- 9 hours per day, Monday through Friday, excluding holidays, 4-hour average response.
- 24 hours per day, 7 days a week, 4-hour average response
- 24 hours per day, 7 days a week, 2-hour average response
Note: Canada does not offer 2-hour response option.
Customer Replaceable Unit (CRU) Service
If your problem can be resolved with a CRU (for example, memory, or hard disk drive), and depending upon the maintenance service offerings in your geography, IBM will ship the replacement CRU to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM at any time upon your request.
Based upon availability, CRUs will be shipped for next business day delivery. IBM specifies in the materials shipped with a replacement CRU whether a defective CRU must be returned to IBM . When return is required, return instructions and a container are shipped with the replacement CRU, and you may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.
CRUs may be provided as part of the machine's standard maintenance service except that you may install a CRU yourself or request IBM installation, at no additional charge, under any of the On-site Service levels specified above.
Non-IBM parts service
Under certain conditions, IBM provides services for selected non-IBM parts at no additional charge for machines that are covered under warranty service upgrades or maintenance services.
This service includes hardware problem determination (PD) on the non-IBM parts (for example, adapter cards, PCMCIA cards, disk drives, memory) installed within IBM machines and provides the labor to replace the failing parts at no additional charge.
If IBM has a Technical Service Agreement with the manufacturer of the failing part, or if the failing part is an accommodations part (a part with an IBM FRU label), IBM may also source and replace the failing part at no additional charge. For all other non-IBM parts, customers are responsible for sourcing the parts. Installation labor is provided at no additional charge, if the machine is covered under a warranty service upgrade or a maintenance service.
Warranty service upgrades
Usage plan machine
No
IBM hourly service rate classification
One
When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order.
Field-installable features
Yes
Model conversions
No
Machine installation
Customer setup. Customers are responsible for installation according to the instructions IBM provides with the machine.
Graduated program license charges apply
Yes.
The applicable processor tier is Small.
Licensed machine code
IBM Machine Code is licensed for use by a customer on the IBM machine for which it was provided by IBM under the terms and conditions of the IBM License Agreement for Machine Code, to enable the machine to function in accordance with its specifications, and only for the capacity authorized by IBM and acquired by the customer. You can obtain the agreement by contacting your IBM representative or visiting
Machine using LMC Type Model 7895-23X
Access to Machine Code updates is conditioned on entitlement and license validation in accordance with IBM policy and practice. IBM may verify entitlement through customer number, serial number, electronic restrictions, or any other means or methods employed by IBM in its discretion.
If the machine does not function as warranted and your problem can be resolved through your application of downloadable Machine Code, you are responsible for downloading and installing these designated Machine Code changes as IBM specifies. If you would prefer, you may request IBM to install downloadable Machine Code changes; however, you may be charged for that service.
Access to " IBM PureFlex System" fix downloads will be granted upon entitlement validation. The terms and conditions for fixes will be covered under the License Agreement for Machine Code, International Program License Agreement, International License Agreement for Non-Warranted Programs and/or other terms provided with the fix, as applicable.
Educational allowance
A reduced charge is available to qualified education customers. The educational allowance may not be added to any other discount or allowance.
The educational allowance is 5% for the products in this announcement.
|
Prices |
For additional information and current prices, contact your local IBM representative.
The following are newly announced features on the specific models of the IBM Power Systems 7895 machine type:
Minimum Initial/ Monthly MES/ Model Feature Purchase Maint. Both/ RP Description number number Price Charge Support CSU MES
IBM 7895-23X 23X Yes One CSC Billing Unit 23X 0010 Both Yes No Ten CSC Billing Units 23X 0011 Both Yes No AIX Partition Specify 23X 0265 Both Yes No Linux Partition Specify 23X 0266 Both Yes No IBM i Partition Specify 23X 0267 Both Yes No IBM i 6.1 w/6.1.1 Machine Code 23X 0566 Both Yes No IBM i 7.1 Specify Code 23X 0567 Both Yes No US TAA Compliance Indicator 23X 0983 Both Yes No USB External Docking Station R 23X 1104 Support Yes No USB 500 GB Removable Disk Dr 23X 1107 Both Yes No Custom Serv. Specify, Roch 23X 1140 Both Yes No IB6132 2-port QDR InfiniBand 23X 1761 Both Yes No EN4054 4-port 10Gb E'net Adapt 23X 1762 Both Yes No EN2024 4-port 1Gb E'net Adaptr 23X 1763 Both Yes No FC3172 2-port 8Gb FC Adapter 23X 1764 Both Yes No Primary OS - IBM i 23X 2145 Both Yes No Primary OS AIX 23X 2146 Both Yes No Primary OS Linux 23X 2147 Both Yes No Factory Deconfiguration of 1 c 23X 2319 Initial N/A No Integrate Blade Server Chassis 23X 4645 Initial N/A No Integrate ITE in Chassis 23X 4646 Initial N/A No One and only one rack indicator feature is required on all orders (#4650 to #4666). No Factory Integration Ind. 23X 4650 Initial N/A No Rack Indicator, Rack 1 23X 4651 Initial N/A No Rack Indicator, Rack 2 23X 4652 Initial N/A No Rack Indicator, Rack 3 23X 4653 Initial N/A No Rack Indicator, Rack 4 23X 4654 Initial N/A No Rack Indicator, Rack 5 23X 4655 Initial N/A No Rack Indicator, Rack 6 23X 4656 Initial N/A No Rack Indicator, Rack 7 23X 4657 Initial N/A No Rack Indicator, Rack 8 23X 4658 Initial N/A No Rack Indicator, Rack 9 23X 4659 Initial N/A No Rack Indicator, Rack 10 23X 4660 Initial N/A No Rack Indicator, Rack 11 23X 4661 Initial N/A No Rack Indicator, Rack 12 23X 4662 Initial N/A No Rack Indicator, Rack 13 23X 4663 Initial N/A No Rack Indicator, Rack 14 23X 4664 Initial N/A No Rack Indicator, Rack 15 23X 4665 Initial N/A No Rack Indicator, Rack 16 23X 4666 Initial N/A No ChasIndicator-Not fact integr 23X 4680 Initial N/A No Chassis specify, Chassis #1 23X 4681 Initial N/A No Chassis specify, Chassis #2 23X 4682 Initial N/A No Chassis specify, Chassis #3 23X 4683 Initial N/A No Chassis specify, Chassis #4 23X 4684 Initial N/A No Chassis specify, Chassis #5 23X 4685 Initial N/A No Chassis specify, Chassis #6 23X 4686 Initial N/A No Chassis specify, Chassis #7 23X 4687 Initial N/A No Chassis specify, Chassis #8 23X 4688 Initial N/A No Chassis specify, Chassis #9 23X 4689 Initial N/A No IBM i CBU Specify Code 23X 4898 Both Yes No Software Preinstall 23X 5005 Initial N/A No PowerVM Standard Edition 23X 5227 Both Yes No PowerVM Enterprise Edition 23X 5228 Both Yes No Top Cover, Diskless Model 23X 7067 Both Yes No Top Cover, SSDs Installed 23X 7068 Both Yes No Top Cover, HDDs Installed 23X 7069 Both Yes No Linux Software Preinstall 23X 8143 Initial N/A No Linux Software Preinstall BP 23X 8144 Initial N/A No Software Preinstall 23X 8146 Initial N/A No 8GB (2x4GB RDIMMs) Memory 23X 8196 Both Yes No 177 GB Solid State Drive 23X 8207 Both Yes No 300 GB SAS 10K RPM SAS HDD 23X 8274 Both Yes No 600 GB SAS 10K RPM SFF 23X 8276 Both Yes No 900 GB SAS 10K RPM SFF 23X 8311 Both Yes No One Processor Entitlement 23X 8491 Both Yes No Order Routing Indicator Syste 23X 9169 Initial N/A No New AIX License Core Counter 23X 9440 NC Initial N/A No New IBM i Lic Core Counter 23X 9441 NC Initial N/A No New Red Hat Lic Core Counter 23X 9442 NC Initial N/A No New SUSE Lic Core Counter 23X 9443 NC Initial N/A No Other AIX Lic Core Counter 23X 9444 NC Initial N/A No Other Linux Lic Core Counter 23X 9445 NC Initial N/A No 3rd Party Linux Lic Core Cnt 23X 9446 NC Initial N/A No VIOS Core Counter 23X 9447 NC Initial N/A No Month Indicator 23X 9461 Initial N/A No Day Indicator 23X 9462 Initial N/A No Hour Indicator 23X 9463 Initial N/A No Minute Indicator 23X 9464 Initial N/A No Qty Indicator 23X 9465 Initial N/A No Countable Member Indicator 23X 9466 Initial N/A No CN4058 8-port 10Gb Converged 23X EC24 Both Yes No EN4132 2-port 10Gb RoCE Adaptr 23X EC26 Both Yes No Custom Serv. Specify, Shen 23X ECSC Both Yes No System Guides - English 23X ED31 Both Yes No System Guides - UK English 23X ED32 Both Yes No System Guides - Braz Portugues 23X ED33 Both Yes No System Guides - Japanese 23X ED34 Both Yes No System Guides - Japanese Eng. 23X ED35 Both Yes No System Guides - Korean 23X ED36 Both Yes No System Guides - Korean English 23X ED37 Both Yes No System Guides - Chinese Eng. 23X ED38 Both Yes No System Guides - Chinese HK 23X ED39 Both Yes No System Guides - Chinese Taiwan 23X ED3A Both Yes No System Guides - French 23X ED3B Both Yes No System Guides - Spanish 23X ED3C Both Yes No System Guides - German 23X ED3D Both Yes No System Guides - Italian 23X ED3E Both Yes No 16GB (2 x 8GB RDIMMs) Memory 23X EEMD Both Yes No 32GB (2 x 16GB RDIMMs) Memory 23X EEME Both Yes No 64GB (2 x 32GB RDIMMs) Memory 23X EEMF Both Yes No PureFlex System Express Ind. 23X EFD1 Initial N/A No PureFlex System Standard Ind. 23X EFD2 Initial N/A No PureFlex System Enterprise Ind 23X EFD3 Initial N/A No PureFlex System Expansion Ind 23X EFD4 Initial N/A No PureFlex System Custom Ind. 23X EFD5 Initial N/A No PureFlex Express Expansion Ind 23X EFD6 Initial N/A No PureFlex Standard Expansion In 23X EFD7 Initial N/A No PureFlex Enterprise Expansion 23X EFD8 Initial N/A No BTO Indicator 23X EFD9 Initial N/A No Trial Live Partition Mobility 23X ELPM Both Yes No 16-core 4.1 GHz POWER7+ Proc 23X EPRA Initial N/A No 16-core 3.6 GHz POWER7+ Proc 23X EPRB Initial N/A No 8-core 4.0 GHz POWER7+ Proc 23X EPRD Initial N/A No RFID Tags for Compute Nodes 23X ERF1 Initial N/A No S&H - No Charge 23X ESC0 Initial N/A No S&H 23X ESC4 Initial N/A No 1TB Removable Disk Cartridge 23X EU01 Both Yes No RDX USB External Docking 23X EU04 Both Yes No RDX 320 GB Removable Disk Driv 23X EU08 Both Yes No
Feature conversions
Feature conversions for 7895-23X virtualization engine features:
Parts Purchase From FC: To FC: Returned Price 5227 - PowerVM Standard 5228 - PowerVM No Edition Enterprise Edition
Pricing terms
Prices in the following PDF prices link are suggested list prices on day of announcement for the U.S. only. They are provided for your information only. Dealer prices may vary, and prices may also vary by country. IBM list price does not include tax or shipping and is subject to change without notice.
ServicePac prices
For ServiceElect (ESA) maintenance service charges, contact IBM Global Services at 888-IBM-4343 (426-4343).
IBM Global Financing
IBM Global Financing offers competitive financing to credit-qualified customers to assist them in acquiring IT solutions. Offerings include financing for IT acquisition, including hardware, software, and services, from both IBM and other manufacturers or vendors. Offerings (for all customer segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or visit
IBM Global Financing offerings are provided through IBM Credit LLC in the United States, and other IBM subsidiaries and divisions worldwide to qualified commercial and government customers. Rates are based on a customer's credit rating, financing terms, offering type, equipment type, and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension, or withdrawal without notice.
Financing solutions from IBM Global Financing can help you stretch your budget and affordably acquire the new product. But beyond the initial acquisition, our end-to-end approach to IT management can also help keep your technologies current, reduce costs, minimize risk, and preserve your ability to make flexible equipment decisions throughout the entire technology life cycle.
|
Order now |
To order, contact the Americas Call Centers or your local IBM representative, or your IBM Business Partner.
To identify your local IBM representative or IBM Business Partner, call 800-IBM-4YOU (426-4968).
Phone: 800-IBM-CALL (426-2255) Fax: 800-2IBM-FAX (242-6329) For IBM representative: callserv@ca.ibm.com For IBM Business Partner: pwswna@us.ibm.com Mail: IBM Teleweb Customer Support ibm.com® Sales Execution Center, Americas North 3500 Steeles Ave. East, Tower 3/4 Markham, Ontario Canada L3R 2Z1
Reference: YE001
The Americas Call Centers, our national direct marketing organization, can add your name to the mailing list for catalogs of IBM products.
Note: Shipments will begin after the planned availability date.
Trademarks
IBM Flex System, POWER7+, PureFlex, EnergyScale, IBM Flex System Manager, POWER Hypervisor, Active Memory, Power Systems and Electronic Service Agent are trademarks of IBM Corporation in the United States, other countries, or both.
IBM, POWER7, AIX, PowerVM, Express, Storwize, BNT, Power, Micro-Partitioning, POWER6, PowerHA, PartnerWorld, POWER and ibm.com are registered trademarks of IBM Corporation in the United States, other countries, or both.
Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.
Other company, product, and service names may be trademarks or service marks of others.
Terms of use
IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this announcement at any time without notice. This announcement is provided for your information only. Additional terms of use are located at
For the most current information regarding IBM products, consult your IBM representative or reseller, or visit the IBM worldwide contacts page