IBM FlashSystem 5200 unlocks the power of your data with IBM Spectrum Virtualize, IBM FlashCore Modules, and storage-class memory

IBM United States Hardware Announcement 121-004
February 9, 2021

Table of contents
OverviewOverviewPublicationsPublications
Key requirementsKey requirementsTechnical informationTechnical information
Planned availability datePlanned availability dateTerms and conditionsTerms and conditions
DescriptionDescriptionPricesPrices
Product numberProduct number


At a glance

Top rule

IBM FlashSystem® 5200 is a powerful, compact NVMe end-to-end platform delivering the full capabilities of IBM FlashCore® Modules, storage-class memory, and IBM Spectrum® Virtualize to the entry-level enterprise.



Back to topBack to top

Overview

Top rule

FlashSystem 5200 systems are virtualized, NVMe-based, all-flash, software-defined storage solutions designed to unlock the power of your data by combining IBM® Spectrum Virtualize, IBM FlashCore Modules, and storage-class memory.

IBM FlashSystem 5200 NVMe control enclosures feature:

  • Two node canisters, each with an eight-core processor
  • 64 GB, 256 GB, and 512 GB cache options (32 GB, 128 GB, or 256 GB per canister)
  • 10 Gb iSCSI (copper) connectivity standard with optional 32/16 Gb FC, 12 Gb SAS, and 25/10 Gb iSCSI (optical) connectivity
  • 12 Gb SAS ports for expansion enclosure attachment
  • Twelve slots for 2.5-inch SFF NVMe drives

FlashSystem 5200 offers three 12 Gb SAS expansion enclosure models:

  • FlashSystem 5200 small form factor (SFF) Expansion Enclosure Model 24G supports up to twenty-four 2.5-inch SAS drives
  • FlashSystem 5200 large form factor (LFF) Expansion Enclosure Model 12G supports up to twelve 3.5-inch SAS drives
  • FlashSystem 5200 high-density (HD) Expansion Enclosure Model 92G supports up to ninety-two SAS drives in 3.5-inch carriers

Expansion enclosures can be intermixed within a FlashSystem 5200 system.

FlashSystem 5200 systems scale up to 748 drives with the attachment of FlashSystem 5200 expansion enclosures. FlashSystem 5200 systems can be clustered to help deliver greater performance, bandwidth, and scalability. A FlashSystem 5200 clustered system can contain up to four FlashSystem 5200 systems and up to 2,992 drives.

All FlashSystem 5200 functional capabilities are provided through IBM Spectrum Virtualize licensed machine code.



Back to topBack to top

Key requirements

Top rule

FlashSystem 5200 requires IBM Spectrum Virtualize licensed machine code level 8.4.0.1, or later.

FlashSystem 5200 control enclosures support external storage virtualization. Use of the external virtualization capability is entitled through the acquisition of IBM Spectrum Virtualize Software for SAN Volume Controller (SW PID 5641-VC8 in AAS and SW PID 5725-M19 in Passport Advantage®).

See the FlashSystem 5200 product documentation and the IBM Support site for additional information about licensed machine code levels and other requirements.

For a comprehensive list of supported environments, devices, and configurations, go to the IBM System Storage Interoperation Center (SSIC).



Back to topBack to top

Planned availability date

Top rule

  • February 19, 2021: All IBM FlashSystem 5200 models and features, except as noted below
  • June 11, 2021: TAA Compliance (feature number 0983)



Back to topBack to top

Description

Top rule

FlashSystem 5200 offerings consist of a control enclosure and three expansion enclosure models.

FlashSystem 5200 control enclosure Model 6H2

  • Two node canisters, each with an eight-core processor
  • 64 GB, 256 GB, and 512 GB cache options (32 GB, 128 GB, or 256 GB per canister)
  • 10 Gb iSCSI (copper) connectivity standard with optional 32/16 Gb FC, 12 Gb SAS, and 25/10 Gb iSCSI (optical) connectivity
  • 12 Gb SAS ports for expansion enclosure attachment
  • Twelve slots for 2.5-inch SFF NVMe drives
  • 1U, 19-inch rack mount enclosure with 200 - 240 V AC power supplies

FlashSystem 5200 expansion enclosure models 12G and 24G

  • Two expansion canisters
  • 12 Gb SAS port for control enclosure and expansion enclosure attachment
  • Twelve slots for 3.5-inch LFF SAS drives (Model 12G) and twenty-four slots for 2.5-inch SFF SAS drives (Model 24G)
  • 2U, 19-inch rack mount enclosure with 100 - 240 V AC power supplies

FlashSystem 5200 expansion enclosure Model 92G

  • Two expansion canisters
  • 12 Gb SAS port for control enclosure and expansion enclosure attachment
  • Ninety-two slots for 3.5-inch LFF SAS drives
  • 5U, 19-inch rack mount enclosure with 180 - 264 V AC power supplies

All models are available with a one-year warranty and IBM Storage Proactive Care Base and Advanced options.

FC, SAS, and iSCSI connectivity with intermix flexibility

FlashSystem 5200 systems include four 10 Gb Ethernet ports standard for iSCSI connectivity and two 1 Gb Ethernet ports for service technician use. These models can be configured with up to four I/O adapter cards to provide up to eight 32 Gb ports, up to sixteen 16 Gb FC ports, or up to eight 25/10 Gb Ethernet ports.

Storage-class memory

FlashSystem 5200 supports up to twelve storage-class memory NVMe drives. These small capacity, ultra-low latency drives can be used in conjunction with Easy Tier® to further improve the overall performance of your NVMe workloads, or as a stand-alone flash storage tier with even higher performance.

The following NVMe storage-class memory drives are supported in FlashSystem 5200 control enclosures:

  • 375 GB NVMe storage-class memory drive
  • 750 GB NVMe storage-class memory drive
  • 800 GB NVMe storage-class memory drive
  • 1.6 TB NVMe storage-class memory drive

IBM FlashCore Modules and industry-standard NVMe drive options

FlashSystem 5200 is designed to support FlashCore Modules, industry-standard flash drives, and an intermix of both.

FlashCore Modules integrate IBM MicroLatency® technology, advanced flash management, and reliability into a 2.5-inch SFF NVMe with built-in performance-neutral hardware compression and encryption.

For improved flexibility, FlashSystem 5200 systems also support a variety of industry-standard, self-encrypting NVMe flash drives. Deployments requiring higher flexibility, scalability, density, and cost benefits of hard disk drives can take advantage of FlashSystem 5200 expansion enclosures.

The following NVMe FlashCore Modules are supported in FlashSystem 5200 control enclosures:

  • 4.8 TB NVMe FlashCore Module
  • 9.6 TB NVMe FlashCore Module
  • 19.2 TB NVMe FlashCore Module
  • 38.4 TB NVMe FlashCore Module

The following NVMe industry-standard drives are supported in FlashSystem 5200 control enclosures:

  • 800 GB 3DWPD NVMe flash drive
  • 1.92 TB NVMe flash drive
  • 3.84 TB NVMe flash drive
  • 7.68 TB NVMe flash drive
  • 15.36 TB NVMe flash drive

All drives are dual-port and hot-swappable. Drives can be intermixed in the control enclosure as long as configuration rules are followed. Expansion enclosures can be intermixed behind the control enclosure

Drive options and intermix flexibility meet a complete range of needs

FlashSystem 5200 is designed to support a complete range of data storage requirements, from highly utilized applications to high-capacity, low usage applications with hybrid or all-flash solutions.

The following 3.5-inch LFF drives are supported:

  • High-performance, enterprise-class disk drives: 900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10,000 rpm1
  • High-capacity, archival-class nearline disk drives: 4 TB, 6 TB, 8 TB, 10 TB, 12 TB, 14 TB, 16 TB, and 18 TB 7,200 rpm

1 These are 2.5-inch drives packaged in a 3.5-inch carrier.

The following 2.5-inch SFF drives are supported:

  • Flash drives: 800 GB, 1.92 TB, 3.84 TB, 7.68 TB, 15.36 TB, and 30.72 TB
  • High-performance, enterprise-class disk drives: 900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10,000 rpm
  • High-capacity, archival-class nearline disk drives: 2 TB 7,200 rpm

All drives are dual-port and hot-swappable. Drives of the same form factor can be intermixed within an enclosure, and LFF and SFF expansion enclosures can be intermixed behind either a LFF or SFF control enclosure.

Scalable configurations respond to growing capacity needs

FlashSystem 5200 systems scale to 748 drives per system with the attachment of eight FlashSystem 5200 high-density LFF expansion enclosures. FlashSystem 5200 systems can be clustered to help deliver even greater performance, bandwidth, and storage capacity. With four-way system clustering, the maximum size of a FlashSystem 5200 system increases to 2,992 drives.

Further scalability can be achieved with virtualization of external storage. When FlashSystem 5200 virtualizes an external storage system, capacity in the external system inherits the functional richness and ease of use of FlashSystem 5200.

Designed for high availability

FlashSystem 5200 is designed to offer high system and data availability with the following features:

  • HyperSwap® for high availability with dual-site, active-active access to a volume
  • Dual-active, intelligent node canisters with mirrored cache
  • Dual-port drives with automatic drive failure detection
  • Distributed RAID levels 1, 5, and 6
  • Redundant hardware, including power supplies and fans
  • Hot-swappable and client replaceable components
  • Automated path failover support for the data path between the server and the drives

Rich set of functional capabilities standard with every system

As a member of the FlashSystem family, FlashSystem 5200 leverages IBM Spectrum Virtualize functions and management tools. The following functions are included with FlashSystem 5200 models:

  • Distributed RAID 1, 5, and 6 provides the flexibility to choose the level of data protection required.
  • Virtualization of internal storage enables rapid, flexible provisioning and simple configuration changes.
  • Thin provisioning optimizes efficiency by allocating disk storage space in a flexible manner among multiple users, based on the minimum space required by each user at any given time. With thin provisioning, applications consume only the space they are actually using, not the total space that has been allocated to them.
  • Data reduction pools increase existing infrastructure capacity utilization by leveraging the following efficiency functions:
    • Automatically deallocate and reclaim capacity of thin-provisioned volumes containing deleted data and, for the first time, enable this reclaimed capacity to be reused by other volumes.
    • Block deduplication for increased efficiency of storage usage by utilizing pointers in duplicate blocks rather than keeping multiple copies.
    • Compression that improves efficiency by storing more active primary data in the same physical disk space.
  • Dynamic migration delivers efficiency and business value through a nondisruptive migration function.
  • FlashCopy® enables creation of copies of data for backup, parallel processing, testing, and development, and allows the copies to be available almost immediately. FlashSystem 5200 supports up to 8,192 FlashCopy targets per system.
  • Graphical user interface delivers intuitive data management designed with point-and-click system management capabilities.

Encryption for enhanced data security

FlashSystem 5200 supports encryption for data at rest. Encryption is performed by the control enclosure for data stored within the entire system, the FlashSystem 5200 control enclosure, and all attached FlashSystem 5200 expansion enclosures.

Encryption is enabled on FlashSystem 5200 through the acquisition of the Encryption Enablement feature. This feature enables encryption on the entire system.

The Encryption USB Flash Drives (four pack) feature or IBM Security™ Key Manager (SKLM) are required for encryption keys management.

IBM Storage Insights

Available at no charge, cloud-based IBM Storage Insights provides a single dashboard that gives you a clear view of all your IBM block storage. You'll be able to make better decisions by seeing trends in performance and capacity. Storage health information enables you to focus on areas needing attention and when IBM support is needed, Storage Insights simplifies uploading logs, speeds resolution with online configuration data, and provides an overview of open tickets all in one place. Storage Insights Pro is a subscription service that provides longer historical views of data, more reporting and optimization options, and supports IBM file and block storage together with EMC VNX and VMAX.

There is no ordering required. For registration and installation information, see the IBM Storage Insights Enrollment website.

IBM Power® Private Cloud Rack Solution

IBM FlashSystem 5200 is an integral part of the IBM Power Private Cloud Rack Solution, providing an easy-to-order, prepackaged solution of Red Hat® software, IBM Power servers, IBM FlashSystem 5200, IBM SAN switches, and IBM rack. It comes preconfigured and ready to go with all you need to quickly inject modernization into your existing applications.

Accessibility by people with disabilities

Accessibility Compliance Reports (previously known as a VPAT) containing details on accessibility compliance to standards, including the Worldwide Consortium Web Content Accessibility Guidelines, European Standard EN 301 349, and US Section 508, can be found on the IBM Accessibility Conformance Report Request website.



Back to topBack to top

Product number

Top rule

The following are newly announced features and models on the specified models of the IBM System Storage 4662 machine type:

Description Machine type Model Feature
IBM FlashSystem 5200 LFF Expansion Enclosure 4662 12G  
JEMT Indicator 4662 12G 0021
TAA Compliance 4662 12G 0983
Bulk Order Indicator 4662 12G 5555
Power Cord - EMEA 4662 12G 9716
Power Cord - Australia / New Zealand 4662 12G 9717
Power Cord - Europe / Africa 4662 12G 9718
Power Cord - Denmark 4662 12G 9719
Power Cord - South Africa 4662 12G 9720
Power Cord - Switzerland 4662 12G 9721
Power Cord - Chile / Italy 4662 12G 9722
Power Cord - Israel 4662 12G 9723
Power Cord - Argentina 4662 12G 9725
Power Cord - China 4662 12G 9726
Power Cord - PDU Connection 4662 12G 9730
Power Cord - US/Group 1 4662 12G 9731
Power Cord - Taiwan 4662 12G 9732
Power Cord - Brazil 4662 12G 9733
Power Cord - India 4662 12G 9734
Power Cord - Japan 4662 12G 9735
Power Cord - Korea 4662 12G 9736
Power Cord - Chicago 4662 12G 9737
RFID AG/AP: 902-928 MHz 4662 12G A2EV
RFID EMEA: 865.6-867.8 MHz 4662 12G A2EW
0.6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 12G ACUA
1.5m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 12G ACUB
3m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 12G ACUC
6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 12G ACUE
Generic Bezel 4662 12G ACZA
Generic Packaging 4662 12G ACZF
Order Type 1 Indicator - CTO 4662 12G ADN1
Order Type 2 Indicator - MTM Only 4662 12G ADN2
Order Type 3 Indicator - FC Only 4662 12G ADN3
No Rules Order Indicator 4662 12G ADNR
TAA Designated Country 4662 12G ADZ1
Shipping and Handling - No Charge 4662 12G AG00
Shipping and Handling 4662 12G AGJW
Power Cord - PDU Connection (C20) 4662 12G AHP6
AC Power Supply High Efficiency (Pair) 4662 12G AHPA
Future use - reserved 1 4662 12G AHY1
Future use - reserved 2 4662 12G AHY2
Future use - reserved 3 4662 12G AHY3
Future use - reserved 4 4662 12G AHY4
Future use - reserved 5 4662 12G AHY5
Future use - reserved 6 4662 12G AHY6
Future use - reserved 7 4662 12G AHY7
Future use - reserved 8 4662 12G AHY8
Future use - reserved 9 4662 12G AHY9
Haversack Solution Indicator 4662 12G AHZC
Hybrid Flash Indicator 4662 12G AHZE
900 GB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 4662 12G AL27
1.2 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 4662 12G AL28
1.8 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 4662 12G AL29
2.4 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 4662 12G AL2A
4 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL39
6 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL3A
8 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL3B
10 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL3C
12 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL3D
14 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL3E
16 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL3F
18 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 12G AL3G
IBM Storage Expert Care Indicator 4662 12G ALH0
IBM Storage Expert Care Basic 1 Year 4662 12G ALJ1
IBM Storage Expert Care Basic 2 Year 4662 12G ALJ2
IBM Storage Expert Care Basic 3 Year 4662 12G ALJ3
IBM Storage Expert Care Basic 4 Year 4662 12G ALJ4
IBM Storage Expert Care Basic 5 Year 4662 12G ALJ5
IBM Storage Expert Care Advanced 1 Year 4662 12G ALK1
IBM Storage Expert Care Advanced 2 Year 4662 12G ALK2
IBM Storage Expert Care Advanced 3 Year 4662 12G ALK3
IBM Storage Expert Care Advanced 4 Year 4662 12G ALK4
IBM Storage Expert Care Advanced 5 Year 4662 12G ALK5
CSC ORDER ROUTING INDICATOR - GUADALAJARA 4662 12G ECSM
Route to Power Manufacturing Indicator 4662 12G EFD0
BP Post-Sale Services 4662 12G SVBP
IBM Systems Lab Services Post-Sale Services 4662 12G SVCS
Other IBM Post-Sale Services 4662 12G SVNN
IBM FlashSystem 5200 SFF Expansion Enclosure 4662 24G  
JEMT Indicator 4662 24G 0021
TAA Compliance 4662 24G 0983
Bulk Order Indicator 4662 24G 5555
Power Cord - EMEA 4662 24G 9716
Power Cord - Australia / New Zealand 4662 24G 9717
Power Cord - Europe / Africa 4662 24G 9718
Power Cord - Denmark 4662 24G 9719
Power Cord - South Africa 4662 24G 9720
Power Cord - Switzerland 4662 24G 9721
Power Cord - Chile / Italy 4662 24G 9722
Power Cord - Israel 4662 24G 9723
Power Cord - Argentina 4662 24G 9725
Power Cord - China 4662 24G 9726
Power Cord - PDU Connection 4662 24G 9730
Power Cord - US/Group 1 4662 24G 9731
Power Cord - Taiwan 4662 24G 9732
Power Cord - Brazil 4662 24G 9733
Power Cord - India 4662 24G 9734
Power Cord - Japan 4662 24G 9735
Power Cord - Korea 4662 24G 9736
Power Cord - Chicago 4662 24G 9737
RFID AG/AP: 902-928 MHz 4662 24G A2EV
RFID EMEA: 865.6-867.8 MHz 4662 24G A2EW
0.6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 24G ACUA
1.5m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 24G ACUB
3m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 24G ACUC
6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 24G ACUE
Generic Bezel 4662 24G ACZA
Generic Packaging 4662 24G ACZF
Order Type 1 Indicator - CTO 4662 24G ADN1
Order Type 2 Indicator - MTM Only 4662 24G ADN2
Order Type 3 Indicator - FC Only 4662 24G ADN3
No Rules Order Indicator 4662 24G ADNR
TAA Designated Country 4662 24G ADZ1
Shipping and Handling - No Charge 4662 24G AG00
Shipping and Handling 4662 24G AGJW
Power Cord - PDU Connection (C20) 4662 24G AHP6
AC Power Supply High Efficiency (Pair) 4662 24G AHPA
Future use - reserved 1 4662 24G AHY1
Future use - reserved 2 4662 24G AHY2
Future use - reserved 3 4662 24G AHY3
Future use - reserved 4 4662 24G AHY4
Future use - reserved 5 4662 24G AHY5
Future use - reserved 6 4662 24G AHY6
Future use - reserved 7 4662 24G AHY7
Future use - reserved 8 4662 24G AHY8
Future use - reserved 9 4662 24G AHY9
Haversack Solution Indicator 4662 24G AHZC
All Flash Solution Indicator 4662 24G AHZD
Hybrid Flash Indicator 4662 24G AHZE
900 GB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 4662 24G AL68
1.2 TB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 4662 24G AL69
1.8 TB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 4662 24G AL6A
2.4 TB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 4662 24G AL6B
2 TB 7,200 rpm 12 Gb SAS NL 2.5 Inch HDD 4662 24G AL76
1.92TB 12 Gb SAS 2.5 Inch Flash Drive 4662 24G AL80
3.84TB 12 Gb SAS 2.5 Inch Flash Drive 4662 24G AL81
7.68TB 12 Gb SAS 2.5 Inch Flash Drive 4662 24G AL82
15.36TB 12 Gb SAS 2.5 Inch Flash Drive 4662 24G AL83
30.72TB 12 Gb SAS 2.5 Inch Flash Drive 4662 24G AL84
800 GB 3DWPD 12 Gb SAS 2.5 Inch Flash Drive 4662 24G AL8A
IBM Storage Expert Care Indicator 4662 24G ALH0
IBM Storage Expert Care Basic 1 Year 4662 24G ALJ1
IBM Storage Expert Care Basic 2 Year 4662 24G ALJ2
IBM Storage Expert Care Basic 3 Year 4662 24G ALJ3
IBM Storage Expert Care Basic 4 Year 4662 24G ALJ4
IBM Storage Expert Care Basic 5 Year 4662 24G ALJ5
IBM Storage Expert Care Advanced 1 Year 4662 24G ALK1
IBM Storage Expert Care Advanced 2 Year 4662 24G ALK2
IBM Storage Expert Care Advanced 3 Year 4662 24G ALK3
IBM Storage Expert Care Advanced 4 Year 4662 24G ALK4
IBM Storage Expert Care Advanced 5 Year 4662 24G ALK5
CSC ORDER ROUTING INDICATOR - GUADALAJARA 4662 24G ECSM
Route to Power Manufacturing Indicator 4662 24G EFD0
BP Post-Sale Services 4662 24G SVBP
IBM Systems Lab Services Post-Sale Services 4662 24G SVCS
Other IBM Post-Sale Services 4662 24G SVNN
IBM FlashSystem 5200 NVMe Control Enclosure 4662 6H2  
JEMT Indicator 4662 6H2 0021
TAA Compliance 4662 6H2 0983
Rack Indicator None 4662 6H2 4650
Rack Indicator Rack 1 4662 6H2 4651
Rack Indicator Rack 2 4662 6H2 4652
Rack Indicator Rack 3 4662 6H2 4653
Rack Indicator Rack 4 4662 6H2 4654
Rack Indicator Rack 5 4662 6H2 4655
Rack Indicator Rack 6 4662 6H2 4656
Rack Indicator Rack 7 4662 6H2 4657
Rack Indicator Rack 8 4662 6H2 4658
Rack Indicator Rack 9 4662 6H2 4659
Rack Indicator Rack 10 4662 6H2 4660
Rack Indicator Rack 11 4662 6H2 4661
Rack Indicator Rack 12 4662 6H2 4662
Rack Indicator Rack 13 4662 6H2 4663
Rack Indicator Rack 14 4662 6H2 4664
Rack Indicator Rack 15 4662 6H2 4665
Rack Indicator Rack 16 4662 6H2 4666
Bulk Order Indicator 4662 6H2 5555
Power Cord - EMEA 4662 6H2 9716
Power Cord - Australia / New Zealand 4662 6H2 9717
Power Cord - Europe / Africa 4662 6H2 9718
Power Cord - Denmark 4662 6H2 9719
Power Cord - South Africa 4662 6H2 9720
Power Cord - Switzerland 4662 6H2 9721
Power Cord - Chile / Italy 4662 6H2 9722
Power Cord - Israel 4662 6H2 9723
Power Cord - Argentina 4662 6H2 9725
Power Cord - China 4662 6H2 9726
Power Cord - PDU Connection 4662 6H2 9730
Power Cord - Brazil 4662 6H2 9733
Power Cord - India 4662 6H2 9734
Power Cord - Korea 4662 6H2 9736
RFID AG/AP: 902-928 MHz 4662 6H2 A2EV
RFID EMEA: 865.6-867.8 MHz 4662 6H2 A2EW
25 GbE SW SFP28 Transceivers (Four) 4662 6H2 ACHP
10 GbE SW SFP+ Transceivers (Four) 4662 6H2 ACHQ
16 Gb FC LW SFP Transceivers(Pair) 4662 6H2 ACHU
1m OM3 Fiber Cable (LC) 4662 6H2 ACSQ
5m OM3 Fiber Cable (LC) 4662 6H2 ACSR
10m OM3 Fiber Cable (LC) 4662 6H2 ACSS
25m OM3 Fiber Cable (LC) 4662 6H2 ACST
0.6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 6H2 ACUA
1.5m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 6H2 ACUB
3m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 6H2 ACUC
6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 6H2 ACUE
Generic Bezel 4662 6H2 ACZA
Generic Packaging 4662 6H2 ACZF
Order Type 1 Indicator - CTO 4662 6H2 ADN1
Order Type 2 Indicator - MTM Only 4662 6H2 ADN2
Order Type 3 Indicator - FC Only 4662 6H2 ADN3
No Rules Order Indicator 4662 6H2 ADNR
TAA Designated Country 4662 6H2 ADZ1
Shipping and Handling - No Charge 4662 6H2 AG00
Shipping and Handling 4662 6H2 AGJW
4.8 TB NVMe Flash Core Module 4662 6H2 AGS5
9.6 TB NVMe Flash Core Module 4662 6H2 AGS6
19.2 TB NVMe Flash Core Module 4662 6H2 AGS7
38.4 TB NVMe Flash Core Module 4662 6H2 AGS8
800 GB NVMe Flash Drive 4662 6H2 AGT1
1.92 TB NVMe Flash Drive 4662 6H2 AGT2
3.84 TB NVMe Flash Drive 4662 6H2 AGT3
7.68 TB NVMe Flash Drive 4662 6H2 AGT4
15.36 TB NVMe Flash Drive 4662 6H2 AGT5
375 GB NVMe Storage Class Memory Drive 4662 6H2 AGTA
750 GB NVMe Storage Class Memory Drive 4662 6H2 AGTB
800 GB NVMe Storage Class Memory Drive 4662 6H2 AGTE
1.6 TB NVMe Storage Class Memory Drive 4662 6H2 AGTF
Power Cord - PDU Connection (C20) 4662 6H2 AHP6
AC Power Supply (Pair) 4662 6H2 AHPE
Future use - reserved 1 4662 6H2 AHY1
Future use - reserved 2 4662 6H2 AHY2
Future use - reserved 3 4662 6H2 AHY3
Future use - reserved 4 4662 6H2 AHY4
Future use - reserved 5 4662 6H2 AHY5
Future use - reserved 6 4662 6H2 AHY6
Future use - reserved 7 4662 6H2 AHY7
Future use - reserved 8 4662 6H2 AHY8
Future use - reserved 9 4662 6H2 AHY9
Haversack Solution Indicator 4662 6H2 AHZC
All Flash Solution Indicator 4662 6H2 AHZD
Hybrid Flash Indicator 4662 6H2 AHZE
Red Hat® OpenShift® Indicator 4662 6H2 AJGH
16 Gb FC 4 Port Adapter Cards (Pair) 4662 6H2 ALBJ
32 Gb FC 2 Port Adapter Cards (Pair) 4662 6H2 ALBK
10 Gb Ethernet 4 Port Adapter Cards (Pair) 4662 6H2 ALBL
25/10 GbE (RoCE) 2 Port Adapter Cards (Pair) 4662 6H2 ALBM
25/10 GbE (iWARP) 2 Port Adapter Cards (Pair) 4662 6H2 ALBN
12 Gb SAS 4 Port Adapter Cards (Pair) 4662 6H2 ALBP
SAS Expansion Enclosure Attach Card (Pair) 4662 6H2 ALBQ
Encryption Enablement 4662 6H2 ALE0
Encryption USB Flash Drives (Four Pack) 4662 6H2 ALEC
64 GB Base Cache 4662 6H2 ALG0
512 GB Base Cache 4662 6H2 ALG1
192 GB Cache Upgrade 4662 6H2 ALGC
512 GB Cache Upgrade 4662 6H2 ALGD
IBM Storage Expert Care Indicator 4662 6H2 ALH0
IBM Storage Expert Care Basic 1 Year 4662 6H2 ALJ1
IBM Storage Expert Care Basic 2 Year 4662 6H2 ALJ2
IBM Storage Expert Care Basic 3 Year 4662 6H2 ALJ3
IBM Storage Expert Care Basic 4 Year 4662 6H2 ALJ4
IBM Storage Expert Care Basic 5 Year 4662 6H2 ALJ5
IBM Storage Expert Care Advanced 1 Year 4662 6H2 ALK1
IBM Storage Expert Care Advanced 2 Year 4662 6H2 ALK2
IBM Storage Expert Care Advanced 3 Year 4662 6H2 ALK3
IBM Storage Expert Care Advanced 4 Year 4662 6H2 ALK4
IBM Storage Expert Care Advanced 5 Year 4662 6H2 ALK5
CSC ORDER ROUTING INDICATOR - GUADALAJARA 4662 6H2 ECSM
Route to Power Manufacturing Indicator 4662 6H2 EFD0
IBM Power® Private Cloud Rack Solution Indicator 4662 6H2 ELG2
BP Post-Sale Services 4662 6H2 SVBP
IBM Systems Lab Services Post-Sale Services 4662 6H2 SVCS
Other IBM Post-Sale Services 4662 6H2 SVNN
IBM FlashSystem 5200 High Density Expansion Enclosure 4662 92G  
JEMT Indicator 4662 92G 0021
TAA Compliance 4662 92G 0983
Bulk Order Indicator 4662 92G 5555
RFID AG/AP: 902-928 MHz 4662 92G A2EV
RFID EMEA: 865.6-867.8 MHz 4662 92G A2EW
3m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 92G ACUC
6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 92G ACUE
Generic Bezel 4662 92G ACZA
Generic Packaging 4662 92G ACZF
Order Type 1 Indicator - CTO 4662 92G ADN1
Order Type 2 Indicator - MTM Only 4662 92G ADN2
Order Type 3 Indicator - FC Only 4662 92G ADN3
No Rules Order Indicator 4662 92G ADNR
TAA Designated Country 4662 92G ADZ1
Shipping and Handling - No Charge 4662 92G AG00
Shipping and Handling 4662 92G AGJW
Power Cord - PDU High Density Expansion 4662 92G AHP5
Future use - reserved 1 4662 92G AHY1
Future use - reserved 2 4662 92G AHY2
Future use - reserved 3 4662 92G AHY3
Future use - reserved 4 4662 92G AHY4
Future use - reserved 5 4662 92G AHY5
Future use - reserved 6 4662 92G AHY6
Future use - reserved 7 4662 92G AHY7
Future use - reserved 8 4662 92G AHY8
Future use - reserved 9 4662 92G AHY9
Haversack Solution Indicator 4662 92G AHZC
All Flash Solution Indicator 4662 92G AHZD
Hybrid Flash Indicator 4662 92G AHZE
1.2 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 4662 92G AL43
1.8 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 4662 92G AL44
2.4 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 4662 92G AL45
6 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 92G AL47
8 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 92G AL48
10 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 92G AL49
12 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 92G AL4A
14 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 92G AL4B
16 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 92G AL4C
18 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 4662 92G AL4D
1.92TB 12 Gb SAS 3.5 Inch Flash Drive 4662 92G AL4J
3.84TB 12 Gb SAS 3.5 Inch Flash Drive 4662 92G AL4K
7.68TB 12 Gb SAS 3.5 Inch Flash Drive 4662 92G AL4L
15.36TB 12 Gb SAS 3.5 Inch Flash Drive 4662 92G AL4M
30.72TB 12 Gb SAS 3.5 Inch Flash Drive 4662 92G AL4N
IBM Storage Expert Care Indicator 4662 92G ALH0
IBM Storage Expert Care Basic 1 Year 4662 92G ALJ1
IBM Storage Expert Care Basic 2 Year 4662 92G ALJ2
IBM Storage Expert Care Basic 3 Year 4662 92G ALJ3
IBM Storage Expert Care Basic 4 Year 4662 92G ALJ4
IBM Storage Expert Care Basic 5 Year 4662 92G ALJ5
IBM Storage Expert Care Advanced 1 Year 4662 92G ALK1
IBM Storage Expert Care Advanced 2 Year 4662 92G ALK2
IBM Storage Expert Care Advanced 3 Year 4662 92G ALK3
IBM Storage Expert Care Advanced 4 Year 4662 92G ALK4
IBM Storage Expert Care Advanced 5 Year 4662 92G ALK5
CSC ORDER ROUTING INDICATOR - GUADALAJARA 4662 92G ECSM
Route to Power Manufacturing Indicator 4662 92G EFD0
BP Post-Sale Services 4662 92G SVBP
IBM Systems Lab Services Post-Sale Services 4662 92G SVCS
Other IBM Post-Sale Services 4662 92G SVNN
IBM FlashSystem 5200 Utility NVMe Control Enclosure 4662 UH6  
JEMT Indicator 4662 UH6 0021
TAA Compliance 4662 UH6 0983
Bulk Order Indicator 4662 UH6 5555
Power Cord - EMEA 4662 UH6 9716
Power Cord - Australia / New Zealand 4662 UH6 9717
Power Cord - Europe / Africa 4662 UH6 9718
Power Cord - Denmark 4662 UH6 9719
Power Cord - South Africa 4662 UH6 9720
Power Cord - Switzerland 4662 UH6 9721
Power Cord - Chile / Italy 4662 UH6 9722
Power Cord - Israel 4662 UH6 9723
Power Cord - Argentina 4662 UH6 9725
Power Cord - China 4662 UH6 9726
Power Cord - PDU Connection 4662 UH6 9730
Power Cord - Brazil 4662 UH6 9733
Power Cord - India 4662 UH6 9734
Power Cord - Korea 4662 UH6 9736
RFID AG/AP: 902-928 MHz 4662 UH6 A2EV
RFID EMEA: 865.6-867.8 MHz 4662 UH6 A2EW
25 GbE SW SFP28 Transceivers (Four) 4662 UH6 ACHP
10 GbE SW SFP+ Transceivers (Four) 4662 UH6 ACHQ
16 Gb FC LW SFP Transceivers(Pair) 4662 UH6 ACHU
1m OM3 Fiber Cable (LC) 4662 UH6 ACSQ
5m OM3 Fiber Cable (LC) 4662 UH6 ACSR
10m OM3 Fiber Cable (LC) 4662 UH6 ACSS
25m OM3 Fiber Cable (LC) 4662 UH6 ACST
0.6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 UH6 ACUA
1.5m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 UH6 ACUB
3m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 UH6 ACUC
6m 12 Gb SAS Cable (mSAS HD to mSAS HD) 4662 UH6 ACUE
Generic Bezel 4662 UH6 ACZA
Generic Packaging 4662 UH6 ACZF
Order Type 1 Indicator - CTO 4662 UH6 ADN1
Order Type 2 Indicator - MTM Only 4662 UH6 ADN2
Order Type 3 Indicator - FC Only 4662 UH6 ADN3
No Rules Order Indicator 4662 UH6 ADNR
TAA Designated Country 4662 UH6 ADZ1
Variable Usage 1TB/month 4662 UH6 AE00
Variable Usage 10TB/month 4662 UH6 AE01
Variable Usage 100TB/month 4662 UH6 AE02
Shipping and Handling - No Charge 4662 UH6 AG00
Shipping and Handling 4662 UH6 AGJW
4.8 TB NVMe Flash Core Module 4662 UH6 AGS5
9.6 TB NVMe Flash Core Module 4662 UH6 AGS6
19.2 TB NVMe Flash Core Module 4662 UH6 AGS7
38.4 TB NVMe Flash Core Module 4662 UH6 AGS8
800 GB NVMe Flash Drive 4662 UH6 AGT1
1.92 TB NVMe Flash Drive 4662 UH6 AGT2
3.84 TB NVMe Flash Drive 4662 UH6 AGT3
7.68 TB NVMe Flash Drive 4662 UH6 AGT4
15.36 TB NVMe Flash Drive 4662 UH6 AGT5
375 GB NVMe Storage Class Memory Drive 4662 UH6 AGTA
750 GB NVMe Storage Class Memory Drive 4662 UH6 AGTB
800 GB NVMe Storage Class Memory Drive 4662 UH6 AGTE
1.6 TB NVMe Storage Class Memory Drive 4662 UH6 AGTF
Power Cord - PDU Connection (C20) 4662 UH6 AHP6
AC Power Supply (Pair) 4662 UH6 AHPE
Future use - reserved 1 4662 UH6 AHY1
Future use - reserved 2 4662 UH6 AHY2
Future use - reserved 3 4662 UH6 AHY3
Future use - reserved 4 4662 UH6 AHY4
Future use - reserved 5 4662 UH6 AHY5
Future use - reserved 6 4662 UH6 AHY6
Future use - reserved 7 4662 UH6 AHY7
Future use - reserved 8 4662 UH6 AHY8
Future use - reserved 9 4662 UH6 AHY9
Haversack Solution Indicator 4662 UH6 AHZC
All Flash Solution Indicator 4662 UH6 AHZD
Hybrid Flash Indicator 4662 UH6 AHZE
Red Hat OpenShift Indicator 4662 UH6 AJGH
16 Gb FC 4 Port Adapter Cards (Pair) 4662 UH6 ALBJ
32 Gb FC 2 Port Adapter Cards (Pair) 4662 UH6 ALBK
10 Gb Ethernet 4 Port Adapter Cards (Pair) 4662 UH6 ALBL
25/10 GbE (RoCE) 2 Port Adapter Cards (Pair) 4662 UH6 ALBM
25/10 GbE (iWARP) 2 Port Adapter Cards (Pair) 4662 UH6 ALBN
12 Gb SAS 4 Port Adapter Cards (Pair) 4662 UH6 ALBP
SAS Expansion Enclosure Attach Card (Pair) 4662 UH6 ALBQ
Encryption Enablement 4662 UH6 ALE0
Encryption USB Flash Drives (Four Pack) 4662 UH6 ALEC
64 GB Base Cache 4662 UH6 ALG0
512 GB Base Cache 4662 UH6 ALG1
192 GB Cache Upgrade 4662 UH6 ALGC
512 GB Cache Upgrade 4662 UH6 ALGD
IBM Storage Expert Care Indicator 4662 UH6 ALH0
IBM Storage Expert Care Basic 1 Year 4662 UH6 ALJ1
IBM Storage Expert Care Basic 2 Year 4662 UH6 ALJ2
IBM Storage Expert Care Basic 3 Year 4662 UH6 ALJ3
IBM Storage Expert Care Basic 4 Year 4662 UH6 ALJ4
IBM Storage Expert Care Basic 5 Year 4662 UH6 ALJ5
IBM Storage Expert Care Advanced 1 Year 4662 UH6 ALK1
IBM Storage Expert Care Advanced 2 Year 4662 UH6 ALK2
IBM Storage Expert Care Advanced 3 Year 4662 UH6 ALK3
IBM Storage Expert Care Advanced 4 Year 4662 UH6 ALK4
IBM Storage Expert Care Advanced 5 Year 4662 UH6 ALK5
No Ship MES 4662 UH6 AQQQ
CSC ORDER ROUTING INDICATOR - GUADALAJARA 4662 UH6 ECSM
Route to Power Manufacturing Indicator 4662 UH6 EFD0
BP Post-Sale Services 4662 UH6 SVBP
IBM Systems Lab Services Post-Sale Services 4662 UH6 SVCS
Other IBM Post-Sale Services 4662 UH6 SVNN



Back to topBack to top

Business Partner information

Top rule

If you are a Direct Reseller - System Reseller acquiring products from IBM, you may link directly to Business Partner information for this announcement. A PartnerWorld ID and password are required (use IBMid).

BP Attachment for Announcement Letter 121-004


Back to topBack to top

Education support

Top rule

IBM Global Services IT Education Services provides education and training to support many IBM offerings. Course descriptions, training paths, and links to other IBM learning resources are available at the IBM Authorized Training website.



Back to topBack to top

Publications

Top rule

To order additional hardcopy publications for a fee or download free PDF format publications, go to the IBM Publications Center website.

IBM Knowledge Center provides you with a single point of reference where you can access product documentation for IBM systems hardware, operating systems, and server software. Through a consistent framework, you can efficiently find information and personalize your access by going to IBM Knowledge Center for all your product information needs.

To access the IBM Publications Center Portal, go to the IBM Publications Center website.

The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, which can currently be downloaded.



Back to topBack to top

Services

Top rule

IBM Systems Lab Services

IBM Systems Lab Services offers a wide array of services available for your enterprise. It brings expertise on the latest technologies from the IBM development community and can help with your most difficult technical challenges.

IBM Systems Lab Services exists to help you successfully implement emerging technologies so as to accelerate your return on investment and improve your satisfaction with your IBM systems and solutions. Services examples include initial implementation, integration, migration, and skills transfer on IBM systems solution capabilities and recommended practices. IBM Systems Lab Services is one of the service organizations of IBM's world-renowned IBM Systems Group development labs.

For details on available services, contact your IBM representative or go to the Lab Services website.

Global Technology Services

IBM services include business consulting, outsourcing, hosting services, applications, and other technology management.

These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an on-demand business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-IBM offerings. IBM is your one-stop shop for IT support needs.

For details on available services, contact your IBM representative or go to the IBM Global Technology Services® website.

For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or go to the Business Continuity website.

Details on education offerings related to specific products can be found on the IBM Training website.



Back to topBack to top

Technical information

Top rule

Specified operating environment

Physical specifications

Control enclosure

  • Height: 4.3 cm (1.7 in.)
  • Width: 44.6 cm (17.5 in.) (19 in. rack standard)
  • Depth: 77.0 cm (30.3 in.)
  • Approximate weight:
    • Empty: 15.9kg (35.0 lb)
    • Fully configured: 19.5kg (43.0 lb)

2U expansion enclosures

  • Height: 8.7 cm (3.4 in)
  • Width: 48.3 cm (19.0 in)
  • Depth: 55.6 cm (21.9 in)
  • Approximate weight:
    • LFF expansion enclosure:
      • Empty: 16.4 kg (36.1 lb)
      • Fully configured: 26.7 kg (58.7 lb)
    • SFF expansion enclosure:
      • Empty: 16.7 kg (36.7 lb)
      • Fully configured: 25.0 kg (55.0 lb)

5U expansion enclosure

  • Height: 220 mm (8.66 in.)
  • Width: 438 mm (17.24 in.)
  • Depth: 1013 mm (39.88 in.)
  • Approximate weight:
    • Empty: 42.5 kg (93.7 lb)
    • Fully configured with flash drives: 78.6 kg (173.3 lb)
    • Fully configured with 10k rpm HDDs: 86 kg (189.6 lb)
    • Fully configured with 7.2k rpm HDDs: 138.6 kg (305.6 lb)

To assure installability and serviceability in non-IBM industry-standard racks, review the installation planning information for any product-specific installation requirements.

Standards

Note: This product was designed, tested, manufactured, and certified for safe operation. It complies with IEC 60950-1 and/or IEC 62368-1 and where required, to relevant national differences/deviations (NDs) to these IEC base standards. This includes, but is not limited to: EN (European Norms including all Amendments under the Low Voltage Directive), UL/CSA (North America bi-national harmonized and marked per accredited NRTL agency listings), and other such derivative certifications according to corporate determinations and latest regional publication compliance standardized requirements.

  • Regulatory Model ID (RMID, for control system base platform): FBIII

(Relevant machine type - models may also be used to supplement identification for worldwide co-compliance filings or registrations with regulatory bodies.)

Operating environment

Air temperature

  • Control enclosure: Operating: 10°C - 35°C (50°F - 95°F) up to 950 m (3,117 ft) above sea level. Above 950 m, de-rate maximum air temperature 1 degree per 175 m.
  • 2U expansion enclosures: 10°C - 35°C (41°F - 104°F) up to 950 m (3,117 ft) above sea level. Above 950 m, de-rate maximum air temperature 1 degree per 175 m.
  • HD expansion enclosure: 5°C - 35°C (41°F - 95°F) up to 950 m (3,117 ft) above sea level. Above 950 m, de-rate maximum air temperature 1 degree per 175 m.
  • Nonoperating: 1°C - 60°C (33.8°F - 140°F)

Relative humidity

  • Operating: 8% - 85%
  • Nonoperating: 8% - 85%

Electrical power

Power consumption will vary with configuration. The product documentation in IBM Knowledge Center contains further examples of measured power consumption.

Control enclosure

  • Voltage range: 200 - 240 V AC
  • Frequency: 50 - 60 Hz
  • Power supply unit (platinum): 1500 watts
  • Maximum power rating: 900 watts
  • Heat dissipation: 3,071 BTU per hour

2U expansion enclosures

  • Voltage range: 100 - 240 V AC
  • Frequency: 50 - 60 Hz
  • Power rating (platinum): 800 watts
  • Heat dissipation: 2,730 BTU per hour

5U expansion enclosure

  • Voltage range: 200 - 240 V AC
  • Frequency: 50 - 60 Hz
  • Power rating (platinum): 2400 watts
  • Heat dissipation: 8,189 BTU per hour

Acoustical noise emission

  • Control enclosure:
    • 6.7 bels (idling)
    • 6.7 bels (operating)
  • LFF expansion enclosure:
    • 6.1 bels (idling)
    • 6.1 bels (operating)
  • SFF expansion enclosure:
    • 6.2 bels (idling)
    • 6.2 bels (operating)
  • HD expansion enclosure:
    • 7.8 bels (idling)
    • 7.8 bels (operating)
Software requirements

FlashSystem 5200 requires IBM Spectrum Virtualize licensed machine code level 8.4.0.1, or later.

IBM FlashSystem 5200 models 6H2 and UH6 support external virtualization. Use of the external virtualization capability is entitled through the acquisition of IBM Spectrum Virtualize software for SAN Volume Controller (SW PID 5641-VC8 in AAS and SW PID 5725-M19 in Passport Advantage).

See the FlashSystem 5200 product documentation and the IBM Support site for additional information on licensed machine code levels and other requirements.

For a comprehensive list of supported environments, devices, and configurations, go to the IBM SSIC website.

Compatibility

For a comprehensive list of supported environments, devices, and configurations, go to the IBM SSIC.

Limitations

Data Reduction Pool deduplication

Deduplication in Data Reduction Pools requires at least 256 GB of cache for operation.

Drive considerations

Distributed RAID 1, 5, and 6 configurations are supported.

Configuration limitations and restrictions

For FlashSystem 5200 configuration limitations and restrictions, go to the IBM Support Portal and enter "FlashSystem 5200 configuration limitations and restrictions" in the Search support box.

Consider the following rules when planning for the maximum configuration in terms of drive slots and expansion enclosures that a specific system can be configured with.

Expansion enclosure attachment rules:

Product Machine type Model SAS chains per control enclosure or node pair Max. expansion enclosure per SAS chain (2U- / 5U-92G) Max. qty of drives per SAS expansion chain Max. qty of drives per control enclosure or node pair Max. qty of drives per clustered system
FlashSystem 5200 4662 6H2 2 10/4 368 736 2,992

2U expansion enclosures and 5U expansion enclosure mix rules:

  Maximum # of Drive Slots per SAS expansion string

5U

                     
2U   0 1 2 3 4 5 6 7 8 9 10
  0 0 24 48 72 96 120 144 168 192 216 240
  1 92 116 140 164 188 212 236 260 - - -
  2 184 208 232 256 280 304 - - - - -
  3 276 300 324 - - - - - - - -
  4 368 - - - - - - - - - -

Encryption

The Encryption Enablement feature (number ALE0) and the Encryption USB Drive Pack feature (feature number ALEC) are not available in the following countries:

  • Belarus
  • Kazakhstan
  • People's Republic of China
  • Russia

Shipments to Australia, India, Korea, New Zealand, Russia, and Taiwan

FlashSystem 5200 machines shipped prior to the published planned availability date for these countries are not compliant with associated country certifications and product labeling requirements. If you did not acquire your machine from IBM as a direct shipment to these countries, you are responsible for validating the machine has the appropriate certifications and product labels.

Contact your IBM sales representative or IBM Business Partner for assistance with this validation.

Certifications and product labels

Machines directly shipped from IBM are compliant with certification and product labeling requirements for the country into which the machine is shipped. You are responsible for validating that the machine has the appropriate certifications and product labels if the machine is relocated to another country.

Contact your IBM sales representative or IBM Business Partner for assistance with this validation.

Planning information

Client responsibilities

Physical configuration and installation planning are client responsibilities.

You are responsible for downloading or obtaining from IBM, and installing designated Machine Code (microcode, basic input/output system code (called BIOS), utility programs, device drivers, and diagnostics delivered with an IBM machine) and other software updates in a timely manner from an IBM internet website or from other electronic media, and following the instructions that IBM provides. You may request IBM to install Machine Code changes; however, you may be charged for that service.

Cable orders

Cables are required for the following:

  • I/O connectivity to servers and fabric components
  • Expansion enclosure attachment
  • System management

As a convenience, a limited selection of cables can be ordered with the FlashSystem 5200 machine. See the Product number section for features numbers.

Cables, along with installation services, are also available from IBM Network Integration and Deployment Services, an IBM Global Services offering.

I/O connectivity cables

Host interface cables are required to connect FlashSystem 5200 I/O ports to server or fabric ports.

32 / 16 Gb FC and 25 / 10 Gb Ethernet (optical): FlashSystem 5200 requires a 50.0/125 micrometer fiber optic cable terminated with an LC Duplex connector. The following fiber optic cables can be ordered with FlashSystem 5200 control enclosure models:

  • 1-meter OM3 fiber cable (LC)
  • 5-meter OM3 fiber cable (LC)
  • 25-meter OM3 fiber cable (LC)
  • 10-meter OM3 fiber cable (LC)

10 Gb Ethernet (copper): The 10 Gb Ethernet ports standard on FlashSystem 5200 require a 10GBASE-T Category 6A shielded cable terminated with an 8P8C modular connector (RJ45 compatible connector). This cable is not available for ordering with the machine and must be supplied by the client.

If these ports are used at a 1 Gb link speed, the 1 Gb Ethernet cables described below can be used.

1 Gb Ethernet: FlashSystem 5200 requires a Category 5 or Category 5E Ethernet cable terminated with an 8P8C modular connector (RJ45 compatible connector). This cable is not available for ordering with the machine and must be supplied by the client.

12 Gb SAS: Control enclosure to host connections, expansion enclosure to control enclosure and to another expansion enclosure connections require 12 Gb mini-SAS HD 4x cables terminated with an SFF-8644 (HD) connector. The following SAS cables can be ordered with FlashSystem 5200 control and expansion enclosure models:

Cables terminated with a SFF-8644 (HD) connector for attachment to the server SAS port:

  • 0.6-meter 12 Gb SAS cable (mSAS HD)
  • 1.5-meter 12 Gb SAS cable (mSAS HD)
  • 3-meter 12 Gb SAS cable (mSAS HD)
  • 6-meter 12 Gb SAS cable (mSAS HD)

Expansion enclosure attachment cables

Expansion enclosure attachment cables are required to connect a FlashSystem 5200 expansion enclosure to the control enclosure and to another expansion enclosure. This requires a 12 Gb mini-SAS HD 4x cable terminated with SFF-8644 (HD) connectors.

The following SAS cables can be ordered with FlashSystem 5200 expansion enclosure models:

  • 0.6-meter 12 Gb SAS cable (mSAS HD)
  • 1.5-meter 12 Gb SAS cable (mSAS HD)
  • 3-meter 12 Gb SAS cable (mSAS HD)
  • 6-meter 12 Gb SAS cable (mSAS HD)

System management cables

FlashSystem 5200 requires:

  • A 10GBASE-T Category 6A shielded cable terminated with an 8P8C modular connector (RJ45 compatible connector) when system management is performed over a 10 Gb link speed.
  • A Category 5 or Category 5E Ethernet cable terminated with an 8P8C modular connector (RJ45 compatible connector) when system management is performed over a 1 Gb link speed.

These cables are not available for ordering with the machine and must be supplied by the client.

Security, auditability, and control

This product uses the security and auditability features of the preloaded application software.

The client is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.

IBM Systems Lab Services

For details on available services, contact your IBM representative or go to the Lab Services website.



Back to topBack to top

Terms and conditions

Top rule

Volume orders

Contact your IBM representative.

IBM Global Financing

Yes

Products - terms and conditions

Warranty period
Warranty and additional coverage options Coverage summary 2

Warranty Period:

Service Level:

One year standard warranty

IBM CRU and On-Site Limited, 9x5 Next Business Day

Service upgrade options 3  
IBM Storage Expert Care Basic Available in 1-5 years

IBM On-Site Repair, 9x5 Next Business Day

Licensed Machine Code Subscription and Support

IBM Storage Expert Care Services:

  • Installation, usage, and configuration support line
  • Predictive alerting
  • Automated ticket management

IBM Storage Expert Care Advanced

Available in 1-5 years

IBM On-Site Repair, 24x7 Same Day

Licensed Machine Code Subscription and Support

IBM Storage Expert Care Services:

  • Installation, usage, and configuration support line
  • Proactive issue resolution
  • Predictive alerting
  • Automated ticket management

2 An IBM Storage Expert Care Service upgrade option is highly recommended but not mandatory.
3 See complete coverage details below.

To obtain copies of the IBM Statement of Limited Warranty, contact your reseller or IBM. An IBM part or feature installed during the initial installation of an IBM machine is subject to the full warranty period specified by IBM. An IBM part or feature that replaces a previously installed part or feature assumes the remainder of the warranty period for the replaced part or feature. An IBM part or feature added to a machine without replacing a previously installed part or feature is subject to a full warranty. Unless specified otherwise, the warranty period, type of warranty service, and service level of a part or feature are the same as those for the machine in which it is installed.

For complete information about the IBM Storage Expert Care Service and Support offerings, see Services Announcement 621-003, dated February 9, 2021.

Warranty service

If required, IBM provides repair or exchange service depending on the types of warranty service specified for the machine. IBM will attempt to resolve your problem over the telephone, or electronically through an IBM website. Certain machines contain remote support capabilities for direct problem reporting, remote problem determination, and resolution with IBM. You must follow the problem determination and resolution procedures that IBM specifies. Following problem determination, if IBM determines on-site service is required, scheduling of service will depend upon the time of your call, machine technology and redundancy, and availability of parts. If applicable to your product, parts considered Client Replaceable Units (CRUs) will be provided as part of the machine's standard warranty service.

Service levels are response-time objectives and are not guaranteed. The specified level of warranty service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country-specific and location-specific information.

CRU Service

IBM provides replacement CRUs to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request. CRUs are designated as being either a Tier 1 (mandatory) or a Tier 2 (optional) CRU.

Tier 1 (mandatory) CRU

Installation of Tier 1 CRUs, as specified in this announcement, is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation.

The following parts have been designated as Tier 1 CRUs (5200 control enclosure):

  • Power Cable
  • I/O adapter
  • SFP
  • DIMM
  • system disk
  • Fiber cable
  • SAS cable
  • Drive
  • Coin cell
  • Bezel
  • Node battery
  • PSU
  • Rail kit
  • Drive blank
  • Node canister

The following parts have been designated as Tier 1 CRUs (5200 2U expansion enclosures):

  • Power cable
  • Drive
  • Bezel
  • PSU
  • Rail kit
  • Drive blank
  • Mini SAS-HD cable
  • Expansion canister

The following parts have been designated as Tier 1 CRUs (5200 5U expansion enclosures):

  • Power cable
  • Drive
  • Fascia
  • PSU
  • Rail kit
  • Fan module
  • Drive blank
  • Mini SAS-HD cable
  • Control panel
  • SAS expander module
  • Cable management arms
  • Lid
  • Fan interface board
  • Expansion canister
  • Enclosure
Tier 2 (optional) CRU

You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge.

Based upon availability, CRUs will be shipped for next business day (NBD) delivery. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM. When return is required, return instructions and a container are shipped with the replacement CRU. You may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.

CRU and On-site Service

At IBM's discretion, you will receive specified CRU service, or IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.

Service level is:

  • 9 hours per day, Monday through Friday, excluding holidays, next business day response. Calls must be received by 5:00 PM local time in order to qualify for next business day response.

Non-IBM parts service

IBM is now shipping machines with selected non-IBM parts that contain an IBM field replaceable unit (FRU) part number label. These parts are to be serviced during the IBM machine warranty period. IBM is covering the service on these selected non-IBM parts as an accommodation to their clients, and normal warranty service procedures for the IBM machine apply.

International Warranty Service

Machine type 4662 is eligible for International Warranty Service. International Warranty Service allows you to relocate any machine that is eligible for International Warranty Service and receive continued warranty service in any country where the IBM machine is serviced. If you move your machine to a different country, you are required to report the machine information to your Business Partner or IBM representative.

The warranty service type and the service level provided in the servicing country may be different from that provided in the country in which the machine was purchased. Warranty service will be provided with the prevailing warranty service type and service level available for the eligible machine type in the servicing country, and the warranty period observed will be that of the country in which the machine was purchased.

The following types of information can be found on the International Warranty Service website

  • Machine warranty entitlement and eligibility
  • Directory of contacts by country with technical support contact information
  • Announcement Letters
Maintenance service options
Maintenance services

If required, IBM provides repair or exchange service depending on the types of maintenance service specified for the machine. IBM will attempt to resolve your problem over the telephone or electronically, through an IBM website. Certain machines contain remote support capabilities for direct problem reporting, remote problem determination, and resolution with IBM. You must follow the problem determination and resolution procedures that IBM specifies. Following problem determination, if IBM determines on-site service is required, scheduling of service will depend upon the time of your call, machine technology and redundancy, and availability of parts. Service levels are response-time objectives and are not guaranteed. The specified level of maintenance service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country-specific and location-specific information. The following service selections are available as maintenance options for your machine type.


On-site Service

IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.

  • On-Site Repair, Monday through Friday (excluding holidays), 8 AM to 5 PM, next business day.
  • On-Site Repair, Monday through Friday (excluding holidays), 8 AM to 5 PM, 4 hour response objective. Response times are objectives and are not guaranteed.
  • On-Site Repair, 7 days a week, 24 hours per day.
  • On-Site Repair, 7 days a week, 24 hours per day, 2 hour response objective. Response times are objectives and are not guaranteed.

Client Replaceable Unit (CRU) Service

If your problem can be resolved with a CRU (for example, DIMM, battery, power supply, drive, or hard disk drive), and depending upon the maintenance service offerings in your geography, IBM will ship the replacement CRU to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request.

Based upon availability, CRUs will be shipped for next business day delivery. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM. When return is required, 1) return instructions and a container are shipped with the replacement CRU, and 2) you may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.

CRUs are designated as being either a Tier 1 (mandatory) or a Tier 2 (optional) CRU.

Tier 1 (mandatory) CRUs: Installation of Tier 1 CRUs, as specified in this announcement, is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation.

For machines with On-site Same-day Response Service, IBM will replace a Tier 1 CRU part at your request, at no additional charge.

Tier 2 (optional) CRUs: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge.

The following parts have been designated as Tier 1 CRUs (control enclosure):

  • Power Cable
  • I/O adapter
  • SFP
  • DIMM
  • Fan modules
  • Fiber cable
  • SAS cable
  • Drive
  • Coin cell
  • Bezel
  • Node battery
  • PSU
  • Rail kit
  • Drive blank
  • Node canister

The following parts have been designated as Tier 1 CRUs (2U expansion enclosures):

  • Power cable
  • Drive
  • Bezel
  • PSU
  • Rail kit
  • Drive blank
  • Mini SAS-HD cable
  • Expansion canister

The following parts have been designated as Tier 1 CRUs (5U expansion enclosures):

  • Power cable
  • Drive
  • Fascia
  • PSU
  • Rail kit
  • Fan module
  • Drive blank
  • Mini SAS-HD cable
  • Control panel
  • SAS expander module
  • Cable management arms
  • Lid
  • Fan interface board
  • Expansion canister
  • Enclosure

Non-IBM parts service

Under certain conditions, IBM provides services for selected non-IBM parts at no additional charge for machines that are covered under warranty service upgrades or maintenance services.

This service includes hardware problem determination (PD) on the non-IBM parts (for example, adapter cards, PCMCIA cards, disk drives, memory) installed within IBM machines and provides the labor to replace the failing parts at no additional charge.

If IBM has a Technical Service Agreement with the manufacturer of the failing part, or if the failing part is an accommodations part (a part with an IBM FRU label), IBM may also source and replace the failing part at no additional charge. For all other non-IBM parts, clients are responsible for sourcing the parts. Installation labor is provided at no additional charge, if the machine is covered under a warranty service upgrade or a maintenance service.

Usage plan machine

No

IBM hourly service rate classification

Two

When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order.

General terms and conditions

Field-installable features

Yes

Model conversions

No

Machine installation

Client setup. Clients are responsible for installation according to the instructions IBM provides with the machine.

Graduated program license charges apply

No

Licensed Machine Code

IBM Machine Code is licensed for use by a client on the IBM machine for which it was provided by IBM under the terms and conditions of the IBM License Agreement for Machine Code, to enable the machine to function in accordance with its specifications, and only for the capacity authorized by IBM and acquired by the client. You can obtain the agreement from the License Agreement for Machine Code and Licensed Internal Code website.

Access to Machine Code updates is conditioned on entitlement and license validation in accordance with IBM policy and practice. IBM may verify entitlement through customer number, serial number, electronic restrictions, or any other means or methods employed by IBM in its discretion.

You may also obtain updated code by contacting your IBM representative.

If the machine does not function as warranted and your problem can be resolved through your application of downloadable Machine Code, you are responsible for downloading and installing these designated Machine Code changes as IBM specifies. If you would prefer, you may request IBM to install downloadable Machine Code changes; however, you may be charged for that service.

Machine Code License Acceptance Requirement

A.) Acceptance-By-Use Machine: Yes, acceptance of the Machine Code license terms is conveyed through the user's initial use of the Machine.

Educational allowance

A reduced charge is available to qualified education clients. The educational allowance may not be added to any other discount or allowance.

The educational allowance is 15% for the products in this announcement.



Back to topBack to top

Prices

Top rule

For additional information and current prices, contact your local IBM representative or IBM Business Partner.

The following are newly announced features and models on the specified models of the IBM System Storage 4662 machine type:

Description Model number Feature numbers Initial / MES / Both / Support CSU RP MES
FlashSytem 5200 Utility UH6   Both Yes  
FS 5200 LFF Expansion 12G   Both Yes  
FS 5200 HD Expansion 92G   Both Yes  
FlashSytem 5200 Control 6H2   Both Yes  
FS 5200 SFF Expansion 24G   Both Yes  
JEMT Indicator 12G 0021 Initial Yes No
TAA Compliance 12G 0983 Initial Yes No
Bulk Order Indicator 12G 5555 MES Yes No
Power Cord - EMEA 12G 9716 Both Yes No
Power Cord - Australia / New Zealand 12G 9717 Both Yes No
Power Cord - Europe / Africa 12G 9718 Both Yes No
Power Cord - Denmark 12G 9719 Both Yes No
Power Cord - South Africa 12G 9720 Both Yes No
Power Cord - Switzerland 12G 9721 Both Yes No
Power Cord - Chile / Italy 12G 9722 Both Yes No
Power Cord - Israel 12G 9723 Both Yes No
Power Cord - Argentina 12G 9725 Both Yes No
Power Cord - China 12G 9726 Both Yes No
Power Cord - PDU Connection 12G 9730 Both Yes No
Power Cord - US/Group 1 12G 9731 Both Yes No
Power Cord - Taiwan 12G 9732 Both Yes No
Power Cord - Brazil 12G 9733 Both Yes No
Power Cord - India 12G 9734 Both Yes No
Power Cord - Japan 12G 9735 Both Yes No
Power Cord - Korea 12G 9736 Both Yes No
Power Cord - Chicago 12G 9737 Both Yes No
RFID AG/AP: 902-928 MHz 12G A2EV Initial Yes No
RFID EMEA: 865.6-867.8 MHz 12G A2EW Initial Yes No
0.6m 12 Gb SAS Cable (mSAS HD) 12G ACUA Both Yes No
1.5m 12 Gb SAS Cable (mSAS HD) 12G ACUB Both Yes No
3m 12 Gb SAS Cable (mSAS HD) 12G ACUC Both Yes No
6m 12 Gb SAS cable (mSAS HD) 12G ACUE Both Yes No
Generic Bezel 12G ACZA Initial Yes No
Generic Packaging 12G ACZF Initial Yes No
Order Type 1 Indicator - CTO 12G ADN1 Initial Yes No
Order Type 2 Indicator - MTM Only 12G ADN2 Initial Yes No
Order Type 3 Indicator - FC Only 12G ADN3 MES Yes No
No Rules Order Indicator 12G ADNR Both Yes No
TAA Designated Country 12G ADZ1 Initial Yes No
Shipping and Handling NC 12G AG00 Initial Yes No
Shipping and Handling 12G AGJW Initial Yes No
Power Cord - PDU C20 12G AHP6 Both Yes No
AC Power Supply HE 12G AHPA Initial Yes No
Future use - reserved 1 12G AHY1 Initial Yes No
Future use - reserved 2 12G AHY2 Initial Yes No
Future use - reserved 3 12G AHY3 Initial Yes No
Future use - reserved 4 12G AHY4 Initial Yes No
Future use - reserved 5 12G AHY5 Initial Yes No
Future use - reserved 6 12G AHY6 Initial Yes No
Future use - reserved 7 12G AHY7 Initial Yes No
Future use - reserved 8 12G AHY8 Initial Yes No
Future use - reserved 9 12G AHY9 Initial Yes No
Haversack Solution Indicator 12G AHZC Initial Yes No
Hybrid Flash Indicator 12G AHZE Initial Yes No
900 GB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 12G AL27 Both Yes No
1.2 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 12G AL28 Both Yes No
1.8 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 12G AL29 Both Yes No
2.4 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 12G AL2A Both Yes No
4 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL39 Both Yes No
6 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL3A Both Yes No
8 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL3B Both Yes No
10 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL3C Both Yes No
12 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL3D Both Yes No
14 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL3E Both Yes No
16 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL3F Both Yes No
18 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 12G AL3G Both Yes No
Expert Care Indicator 12G ALH0 Initial Yes No
EC Basic 1 Year 12G ALJ1 Initial Yes No
EC Basic 2 Year 12G ALJ2 Initial Yes No
EC Basic 3 Year 12G ALJ3 Initial Yes No
EC Basic 4 Year 12G ALJ4 Initial Yes No
EC Basic 5 Year 12G ALJ5 Initial Yes No
EC Advanced 1 Year 12G ALK1 Initial Yes No
EC Advanced 2 Year 12G ALK2 Initial Yes No
EC Advanced 3 Year 12G ALK3 Initial Yes No
EC Advanced 4 Year 12G ALK4 Initial Yes No
EC Advanced 5 Year 12G ALK5 Initial Yes No
CSC ORDER ROUTING INDICATOR - GUADALAJARA 12G ECSM Both Yes No
Route to Power Manufacturing Indicator 12G EFD0 Initial Yes No
BP Post-Sale Services 12G SVBP Both Yes No
IBM Systems Lab Services Post-Sale Services 12G SVCS Both Yes No
Other IBM Post-Sale Services 12G SVNN Both Yes No
JEMT Indicator 24G 0021 Initial Yes No
TAA Compliance 24G 0983 Initial Yes No
Bulk Order Indicator 24G 5555 MES Yes No
Power Cord - EMEA 24G 9716 Both Yes No
Power Cord - Australia / New Zealand 24G 9717 Both Yes No
Power Cord - Europe / Africa 24G 9718 Both Yes No
Power Cord - Denmark 24G 9719 Both Yes No
Power Cord - South Africa 24G 9720 Both Yes No
Power Cord - Switzerland 24G 9721 Both Yes No
Power Cord - Chile / Italy 24G 9722 Both Yes No
Power Cord - Israel 24G 9723 Both Yes No
Power Cord - Argentina 24G 9725 Both Yes No
Power Cord - China 24G 9726 Both Yes No
Power Cord - PDU Connection 24G 9730 Both Yes No
Power Cord - US/Group 1 24G 9731 Both Yes No
Power Cord - Taiwan 24G 9732 Both Yes No
Power Cord - Brazil 24G 9733 Both Yes No
Power Cord - India 24G 9734 Both Yes No
Power Cord - Japan 24G 9735 Both Yes No
Power Cord - Korea 24G 9736 Both Yes No
Power Cord - Chicago 24G 9737 Both Yes No
RFID AG/AP: 902-928 MHz 24G A2EV Initial Yes No
RFID EMEA: 865.6-867.8 MHz 24G A2EW Initial Yes No
0.6m 12 Gb SAS Cable (mSAS HD) 24G ACUA Both Yes No
1.5m 12 Gb SAS Cable (mSAS HD) 24G ACUB Both Yes No
3m 12 Gb SAS Cable (mSAS HD) 24G ACUC Both Yes No
6m 12 Gb SAS cable (mSAS HD) 24G ACUE Both Yes No
Generic Bezel 24G ACZA Initial Yes No
Generic Packaging 24G ACZF Initial Yes No
Order Type 1 Indicator - CTO 24G ADN1 Initial Yes No
Order Type 2 Indicator - MTM Only 24G ADN2 Initial Yes No
Order Type 3 Indicator - FC Only 24G ADN3 MES Yes No
No Rules Order Indicator 24G ADNR Both Yes No
TAA Designated Country 24G ADZ1 Initial Yes No
Shipping and Handling NC 24G AG00 Initial Yes No
Shipping and Handling 24G AGJW Initial Yes No
Power Cord - PDU C20 24G AHP6 Both Yes No
AC Power Supply HE 24G AHPA Initial Yes No
Future use - reserved 1 24G AHY1 Initial Yes No
Future use - reserved 2 24G AHY2 Initial Yes No
Future use - reserved 3 24G AHY3 Initial Yes No
Future use - reserved 4 24G AHY4 Initial Yes No
Future use - reserved 5 24G AHY5 Initial Yes No
Future use - reserved 6 24G AHY6 Initial Yes No
Future use - reserved 7 24G AHY7 Initial Yes No
Future use - reserved 8 24G AHY8 Initial Yes No
Future use - reserved 9 24G AHY9 Initial Yes No
Haversack Solution Indicator 24G AHZC Initial Yes No
All Flash Solution Indicator 24G AHZD Initial Yes No
Hybrid Flash Indicator 24G AHZE Initial Yes No
900 GB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 24G AL68 Both Yes No
1.2 TB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 24G AL69 Both Yes No
1.8 TB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 24G AL6A Both Yes No
2.4 TB 10,000 rpm 12 Gb SAS 2.5 Inch HDD 24G AL6B Both Yes No
2 TB 7,200 rpm 12 Gb SAS NL 2.5 Inch HDD 24G AL76 Both Yes No
1.92TB 12 Gb SAS 2.5 Inch Flash Drive 24G AL80 Both Yes No
3.84TB 12 Gb SAS 2.5 Inch Flash Drive 24G AL81 Both Yes No
7.68TB 12 Gb SAS 2.5 Inch Flash Drive 24G AL82 Both Yes No
15.36TB 12 Gb SAS 2.5 Inch Flash Drive 24G AL83 Both Yes No
30.72TB 12 Gb SAS 2.5 Inch Flash Drive 24G AL84 Both Yes No
800 GB 3DWPD 12 Gb SAS 2.5 Inch Flash Drive 24G AL8A Both Yes No
Expert Care Indicator 24G ALH0 Initial Yes No
EC Basic 1 Year 24G ALJ1 Initial Yes No
EC Basic 2 Year 24G ALJ2 Initial Yes No
EC Basic 3 Year 24G ALJ3 Initial Yes No
EC Basic 4 Year 24G ALJ4 Initial Yes No
EC Basic 5 Year 24G ALJ5 Initial Yes No
EC Advanced 1 Year 24G ALK1 Initial Yes No
EC Advanced 2 Year 24G ALK2 Initial Yes No
EC Advanced 3 Year 24G ALK3 Initial Yes No
EC Advanced 4 Year 24G ALK4 Initial Yes No
EC Advanced 5 Year 24G ALK5 Initial Yes No
CSC ORDER ROUTING INDICATOR - GUADALAJARA 24G ECSM Both Yes No
Route to Power Manufacturing Indicator 24G EFD0 Initial Yes No
BP Post-Sale Services 24G SVBP Both Yes No
IBM Systems Lab Services Post-Sale Services 24G SVCS Both Yes No
Other IBM Post-Sale Services 24G SVNN Both Yes No
JEMT Indicator 6H2 0021 Initial Yes No
TAA Compliance 6H2 0983 Initial Yes No
Rack Indicator None 6H2 4650 Initial Yes No
Rack Indicator Rack 1 6H2 4651 Initial Yes No
Rack Indicator Rack 2 6H2 4652 Initial Yes No
Rack Indicator Rack 3 6H2 4653 Initial Yes No
Rack Indicator Rack 4 6H2 4654 Initial Yes No
Rack Indicator Rack 5 6H2 4655 Initial Yes No
Rack Indicator Rack 6 6H2 4656 Initial Yes No
Rack Indicator Rack 7 6H2 4657 Initial Yes No
Rack Indicator Rack 8 6H2 4658 Initial Yes No
Rack Indicator Rack 9 6H2 4659 Initial Yes No
Rack Indicator Rack 10 6H2 4660 Initial Yes No
Rack Indicator Rack 11 6H2 4661 Initial Yes No
Rack Indicator Rack 12 6H2 4662 Initial Yes No
Rack Indicator Rack 13 6H2 4663 Initial Yes No
Rack Indicator Rack 14 6H2 4664 Initial Yes No
Rack Indicator Rack 15 6H2 4665 Initial Yes No
Rack Indicator Rack 16 6H2 4666 Initial Yes No
Bulk Order Indicator 6H2 5555 MES Yes No
Power Cord - EMEA 6H2 9716 Both Yes No
Power Cord - Australia / New Zealand 6H2 9717 Both Yes No
Power Cord - Europe / Africa 6H2 9718 Both Yes No
Power Cord - Denmark 6H2 9719 Both Yes No
Power Cord - South Africa 6H2 9720 Both Yes No
Power Cord - Switzerland 6H2 9721 Both Yes No
Power Cord - Chile / Italy 6H2 9722 Both Yes No
Power Cord - Israel 6H2 9723 Both Yes No
Power Cord - Argentina 6H2 9725 Both Yes No
Power Cord - China 6H2 9726 Both Yes No
Power Cord - PDU Connection 6H2 9730 Both Yes No
Power Cord - Brazil 6H2 9733 Both Yes No
Power Cord - India 6H2 9734 Both Yes No
Power Cord - Korea 6H2 9736 Both Yes No
RFID AG/AP: 902-928 MHz 6H2 A2EV Initial Yes No
RFID EMEA: 865.6-867.8 MHz 6H2 A2EW Initial Yes No
25 GbE SW SFP28 Transceivers (Four) 6H2 ACHP Both Yes No
10 GbE SW SFP+ Transceivers (Four) 6H2 ACHQ Both Yes No
16 Gb FC LW SFP Transceivers(Pair) 6H2 ACHU Both Yes No
1m OM3 Fiber Cable (LC) 6H2 ACSQ Both Yes No
5m OM3 Fiber Cable (LC) 6H2 ACSR Both Yes No
10m OM3 Fiber Cable (LC) 6H2 ACSS Both Yes No
25m OM3 Fiber Cable (LC) 6H2 ACST Both Yes No
0.6m 12 Gb SAS Cable (mSAS HD) 6H2 ACUA Both Yes No
1.5m 12 Gb SAS Cable (mSAS HD) 6H2 ACUB Both Yes No
3m 12 Gb SAS Cable (mSAS HD) 6H2 ACUC Both Yes No
6m 12 Gb SAS cable (mSAS HD) 6H2 ACUE Both Yes No
Generic Bezel 6H2 ACZA Initial Yes No
Generic Packaging 6H2 ACZF Initial Yes No
Order Type 1 Indicator - CTO 6H2 ADN1 Initial Yes No
Order Type 2 Indicator - MTM Only 6H2 ADN2 Initial Yes No
Order Type 3 Indicator - FC Only 6H2 ADN3 MES Yes No
No Rules Order Indicator 6H2 ADNR Both Yes No
TAA Designated Country 6H2 ADZ1 Initial Yes No
Shipping and Handling NC 6H2 AG00 Initial Yes No
Shipping and Handling 6H2 AGJW Initial Yes No
4.8 TB NVMe Flash Core Module 6H2 AGS5 Both Yes No
9.6 TB NVMe Flash Core Module 6H2 AGS6 Both Yes No
19.2 TB NVMe Flash Core Module 6H2 AGS7 Both Yes No
38.4 TB NVMe Flash Core Module 6H2 AGS8 Both Yes No
800 GB NVMe Flash Drive 6H2 AGT1 Both Yes No
1.92 TB NVMe Flash Drive 6H2 AGT2 Both Yes No
3.84 TB NVMe Flash Drive 6H2 AGT3 Both Yes No
7.68 TB NVMe Flash Drive 6H2 AGT4 Both Yes No
15.36 TB NVMe Flash Drive 6H2 AGT5 Both Yes No
375 GB NVMe Storage Class Memory Drive 6H2 AGTA Both Yes No
750 GB NVMe Storage Class Memory Drive 6H2 AGTB Both Yes No
800 GB NVMe Storage Class Memory Drive 6H2 AGTE Both Yes No
1.6 TB NVMe Storage Class Memory Drive 6H2 AGTF Both Yes No
Power Cord - PDU C20 6H2 AHP6 Both Yes No
AC Power Supply (Pair) 6H2 AHPE Initial Yes No
Future use - reserved 1 6H2 AHY1 Initial Yes No
Future use - reserved 2 6H2 AHY2 Initial Yes No
Future use - reserved 3 6H2 AHY3 Initial Yes No
Future use - reserved 4 6H2 AHY4 Initial Yes No
Future use - reserved 5 6H2 AHY5 Initial Yes No
Future use - reserved 6 6H2 AHY6 Initial Yes No
Future use - reserved 7 6H2 AHY7 Initial Yes No
Future use - reserved 8 6H2 AHY8 Initial Yes No
Future use - reserved 9 6H2 AHY9 Initial Yes No
Haversack Solution Indicator 6H2 AHZC Initial Yes No
All Flash Solution Indicator 6H2 AHZD Initial Yes No
Hybrid Flash Indicator 6H2 AHZE Initial Yes No
Red Hat OpenShift Indicator 6H2 AJGH Initial Yes No
16 Gb FC 4 Port Adapter Cards (Pair) 6H2 ALBJ Both Yes No
32 Gb FC 2 Port Adapter Cards (Pair) 6H2 ALBK Both Yes No
10 Gb Ethernet 4 Port Adapter Cards (Pair) 6H2 ALBL Both Yes No
25/10 GbE (RoCE) 2 Port Adapter Cards (Pair) 6H2 ALBM Both Yes No
25/10 GbE (iWARP) 2 Port Adapter Cards (Pair) 6H2 ALBN Both Yes No
12 Gb SAS 4 Port Adapter Cards (Pair) 6H2 ALBP Both Yes No
SAS Expansion Enclosure Attach Card (Pair) 6H2 ALBQ Both Yes No
Encryption Enablement 6H2 ALE0 Both Yes No
Encryption USB Flash Drives (Four Pack) 6H2 ALEC Both Yes No
64 GB Base Cache 6H2 ALG0 Initial Yes No
512 GB Base Cache 6H2 ALG1 Initial Yes No
192 GB Cache Upgrade 6H2 ALGC Both Yes No
512 GB Cache Upgrade 6H2 ALGD MES Yes No
Expert Care Indicator 6H2 ALH0 Initial Yes No
EC Basic 1 Year 6H2 ALJ1 Initial Yes No
EC Basic 2 Year 6H2 ALJ2 Initial Yes No
EC Basic 3 Year 6H2 ALJ3 Initial Yes No
EC Basic 4 Year 6H2 ALJ4 Initial Yes No
EC Basic 5 Year 6H2 ALJ5 Initial Yes No
EC Advanced 1 Year 6H2 ALK1 Initial Yes No
EC Advanced 2 Year 6H2 ALK2 Initial Yes No
EC Advanced 3 Year 6H2 ALK3 Initial Yes No
EC Advanced 4 Year 6H2 ALK4 Initial Yes No
EC Advanced 5 Year 6H2 ALK5 Initial Yes No
CSC ORDER ROUTING INDICATOR - GUADALAJARA 6H2 ECSM Both Yes No
Route to Power Manufacturing Indicator 6H2 EFD0 Initial Yes No
IBM Power Private Cloud Rack Solution Indicator 6H2 ELG2 Initial Yes No
BP Post-Sale Services 6H2 SVBP Both Yes No
IBM Systems Lab Services Post-Sale Services 6H2 SVCS Both Yes No
Other IBM Post-Sale Services 6H2 SVNN Both Yes No
JEMT Indicator 92G 0021 Initial Yes No
TAA Compliance 92G 0983 Initial Yes No
Bulk Order Indicator 92G 5555 MES Yes No
RFID AG/AP: 902-928 MHz 92G A2EV Initial Yes No
RFID EMEA: 865.6-867.8 MHz 92G A2EW Initial Yes No
3m 12 Gb SAS Cable (mSAS HD) 92G ACUC Both Yes No
6m 12 Gb SAS cable (mSAS HD) 92G ACUE Both Yes No
Generic Bezel 92G ACZA Initial Yes No
Generic Packaging 92G ACZF Initial Yes No
Order Type 1 Indicator - CTO 92G ADN1 Initial Yes No
Order Type 2 Indicator - MTM Only 92G ADN2 Initial Yes No
Order Type 3 Indicator - FC Only 92G ADN3 MES Yes No
No Rules Order Indicator 92G ADNR Both Yes No
TAA Designated Country 92G ADZ1 Initial Yes No
Shipping and Handling NC 92G AG00 Initial Yes No
Shipping and Handling 92G AGJW Initial Yes No
Power Cord - PDU HD Exp. 92G AHP5 Both Yes No
Future use - reserved 1 92G AHY1 Initial Yes No
Future use - reserved 2 92G AHY2 Initial Yes No
Future use - reserved 3 92G AHY3 Initial Yes No
Future use - reserved 4 92G AHY4 Initial Yes No
Future use - reserved 5 92G AHY5 Initial Yes No
Future use - reserved 6 92G AHY6 Initial Yes No
Future use - reserved 7 92G AHY7 Initial Yes No
Future use - reserved 8 92G AHY8 Initial Yes No
Future use - reserved 9 92G AHY9 Initial Yes No
Haversack Solution Indicator 92G AHZC Initial Yes No
All Flash Solution Indicator 92G AHZD Initial Yes No
Hybrid Flash Indicator 92G AHZE Initial Yes No
1.2 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 92G AL43 Both Yes No
1.8 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 92G AL44 Both Yes No
2.4 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD 92G AL45 Both Yes No
6 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 92G AL47 Both Yes No
8 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 92G AL48 Both Yes No
10 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 92G AL49 Both Yes No
12 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 92G AL4A Both Yes No
14 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 92G AL4B Both Yes No
16 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 92G AL4C Both Yes No
18 TB 7,200 rpm 12 Gb SAS NL 3.5 Inch HDD 92G AL4D Both Yes No
1.92TB 12 Gb SAS 3.5 Inch Flash Drive 92G AL4J Both Yes No
3.84TB 12 Gb SAS 3.5 Inch Flash Drive 92G AL4K Both Yes No
7.68TB 12 Gb SAS 3.5 Inch Flash Drive 92G AL4L Both Yes No
15.36TB 12 Gb SAS 3.5 Inch Flash Drive 92G AL4M Both Yes No
30.72TB 12 Gb SAS 3.5 Inch Flash Drive 92G AL4N Both Yes No
Expert Care Indicator 92G ALH0 Initial Yes No
EC Basic 1 Year 92G ALJ1 Initial Yes No
EC Basic 2 Year 92G ALJ2 Initial Yes No
EC Basic 3 Year 92G ALJ3 Initial Yes No
EC Basic 4 Year 92G ALJ4 Initial Yes No
EC Basic 5 Year 92G ALJ5 Initial Yes No
EC Advanced 1 Year 92G ALK1 Initial Yes No
EC Advanced 2 Year 92G ALK2 Initial Yes No
EC Advanced 3 Year 92G ALK3 Initial Yes No
EC Advanced 4 Year 92G ALK4 Initial Yes No
EC Advanced 5 Year 92G ALK5 Initial Yes No
CSC ORDER ROUTING INDICATOR - GUADALAJARA 92G ECSM Both Yes No
Route to Power Manufacturing Indicator 92G EFD0 Initial Yes No
BP Post-Sale Services 92G SVBP Both Yes No
IBM Systems Lab Services Post-Sale Services 92G SVCS Both Yes No
Other IBM Post-Sale Services 92G SVNN Both Yes No
JEMT Indicator UH6 0021 Initial Yes No
TAA Compliance UH6 0983 Initial Yes No
Bulk Order Indicator UH6 5555 MES Yes No
Power Cord - EMEA UH6 9716 Both Yes No
Power Cord - Australia / New Zealand UH6 9717 Both Yes No
Power Cord - Europe / Africa UH6 9718 Both Yes No
Power Cord - Denmark UH6 9719 Both Yes No
Power Cord - South Africa UH6 9720 Both Yes No
Power Cord - Switzerland UH6 9721 Both Yes No
Power Cord - Chile / Italy UH6 9722 Both Yes No
Power Cord - Israel UH6 9723 Both Yes No
Power Cord - Argentina UH6 9725 Both Yes No
Power Cord - China UH6 9726 Both Yes No
Power Cord - PDU Connection UH6 9730 Both Yes No
Power Cord - Brazil UH6 9733 Both Yes No
Power Cord - India UH6 9734 Both Yes No
Power Cord - Korea UH6 9736 Both Yes No
RFID AG/AP: 902-928 MHz UH6 A2EV Initial Yes No
RFID EMEA: 865.6-867.8 MHz UH6 A2EW Initial Yes No
25 GbE SW SFP28 Transceivers (Four) UH6 ACHP Both Yes No
10 GbE SW SFP+ Transceivers (Four) UH6 ACHQ Both Yes No
16 Gb FC LW SFP Transceivers(Pair) UH6 ACHU Both Yes No
1m OM3 Fiber Cable (LC) UH6 ACSQ Both Yes No
5m OM3 Fiber Cable (LC) UH6 ACSR Both Yes No
10m OM3 Fiber Cable (LC) UH6 ACSS Both Yes No
25m OM3 Fiber Cable (LC) UH6 ACST Both Yes No
0.6m 12 Gb SAS Cable (mSAS HD) UH6 ACUA Both Yes No
1.5m 12 Gb SAS Cable (mSAS HD) UH6 ACUB Both Yes No
3m 12 Gb SAS Cable (mSAS HD) UH6 ACUC Both Yes No
6m 12 Gb SAS cable (mSAS HD) UH6 ACUE Both Yes No
Generic Bezel UH6 ACZA Initial Yes No
Generic Packaging UH6 ACZF Initial Yes No
Order Type 1 Indicator - CTO UH6 ADN1 Initial Yes No
Order Type 2 Indicator - MTM Only UH6 ADN2 Initial Yes No
Order Type 3 Indicator - FC Only UH6 ADN3 MES Yes No
No Rules Order Indicator UH6 ADNR Both Yes No
TAA Designated Country UH6 ADZ1 Initial Yes No
Variable Usage 1TB/month UH6 AE00 MES Yes No
Variable Usage 10TB/month UH6 AE01 MES Yes No
Variable Usage 100TB/month UH6 AE02 MES Yes No
Shipping and Handling NC UH6 AG00 Initial Yes No
Shipping and Handling UH6 AGJW Initial Yes No
4.8 TB NVMe Flash Core Module UH6 AGS5 Both Yes No
9.6 TB NVMe Flash Core Module UH6 AGS6 Both Yes No
19.2 TB NVMe Flash Core Module UH6 AGS7 Both Yes No
38.4 TB NVMe Flash Core Module UH6 AGS8 Both Yes No
800 GB NVMe Flash Drive UH6 AGT1 Both Yes No
1.92 TB NVMe Flash Drive UH6 AGT2 Both Yes No
3.84 TB NVMe Flash Drive UH6 AGT3 Both Yes No
7.68 TB NVMe Flash Drive UH6 AGT4 Both Yes No
15.36 TB NVMe Flash Drive UH6 AGT5 Both Yes No
375 GB NVMe Storage Class Memory Drive UH6 AGTA Both Yes No
750 GB NVMe Storage Class Memory Drive UH6 AGTB Both Yes No
800 GB NVMe Storage Class Memory Drive UH6 AGTE Both Yes No
1.6 TB NVMe Storage Class Memory Drive UH6 AGTF Both Yes No
Power Cord - PDU C20 UH6 AHP6 Both Yes No
AC Power Supply (Pair) UH6 AHPE Initial Yes No
Future use - reserved 1 UH6 AHY1 Initial Yes No
Future use - reserved 2 UH6 AHY2 Initial Yes No
Future use - reserved 3 UH6 AHY3 Initial Yes No
Future use - reserved 4 UH6 AHY4 Initial Yes No
Future use - reserved 5 UH6 AHY5 Initial Yes No
Future use - reserved 6 UH6 AHY6 Initial Yes No
Future use - reserved 7 UH6 AHY7 Initial Yes No
Future use - reserved 8 UH6 AHY8 Initial Yes No
Future use - reserved 9 UH6 AHY9 Initial Yes No
Haversack Solution Indicator UH6 AHZC Initial Yes No
All Flash Solution Indicator UH6 AHZD Initial Yes No
Hybrid Flash Indicator UH6 AHZE Initial Yes No
Red Hat OpenShift Indicator UH6 AJGH Initial Yes No
16 Gb FC 4 Port Adapter Cards (Pair) UH6 ALBJ Both Yes No
32 Gb FC 2 Port Adapter Cards (Pair) UH6 ALBK Both Yes No
10 Gb Ethernet 4 Port Adapter Cards (Pair) UH6 ALBL Both Yes No
25/10 GbE (RoCE) 2 Port Adapter Cards (Pair) UH6 ALBM Both Yes No
25/10 GbE (iWARP) 2 Port Adapter Cards (Pair) UH6 ALBN Both Yes No
12 Gb SAS 4 Port Adapter Cards (Pair) UH6 ALBP Both Yes No
SAS Expansion Enclosure Attach Card (Pair) UH6 ALBQ Both Yes No
Encryption Enablement UH6 ALE0 Both Yes No
Encryption USB Flash Drives (Four Pack) UH6 ALEC Both Yes No
64 GB Base Cache UH6 ALG0 Initial Yes No
512 GB Base Cache UH6 ALG1 Initial Yes No
192 GB Cache Upgrade UH6 ALGC Both Yes No
512 GB Cache Upgrade UH6 ALGD MES Yes No
Expert Care Indicator UH6 ALH0 Initial Yes No
EC Basic 1 Year UH6 ALJ1 Initial Yes No
EC Basic 2 Year UH6 ALJ2 Initial Yes No
EC Basic 3 Year UH6 ALJ3 Initial Yes No
EC Basic 4 Year UH6 ALJ4 Initial Yes No
EC Basic 5 Year UH6 ALJ5 Initial Yes No
EC Advanced 1 Year UH6 ALK1 Initial Yes No
EC Advanced 2 Year UH6 ALK2 Initial Yes No
EC Advanced 3 Year UH6 ALK3 Initial Yes No
EC Advanced 4 Year UH6 ALK4 Initial Yes No
EC Advanced 5 Year UH6 ALK5 Initial Yes No
No Ship MES UH6 AQQQ MES Yes No
CSC ORDER ROUTING INDICATOR - GUADALAJARA UH6 ECSM Both Yes No
Route to Power Manufacturing Indicator UH6 EFD0 Initial Yes No
BP Post-Sale Services UH6 SVBP Both Yes No
IBM Systems Lab Services Post-Sale Services UH6 SVCS Both Yes No
Other IBM Post-Sale Services UH6 SVNN Both Yes No

CSU = Customer setup

RP MES = Returnable part MES

ServiceElect (ESA) charges

For ServiceElect (ESA) maintenance service charges, contact IBM Global Services at 888-IBM-4343 (426-4343).

IBM Global Financing

IBM Global Financing offers competitive financing to credit-qualified clients to assist them in acquiring IT solutions. Offerings include financing for IT acquisition, including hardware, software, and services, from both IBM and other manufacturers or vendors. Offerings (for all client segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or go to the IBM Global Financing website for more information.

IBM Global Financing offerings are provided through IBM Credit LLC in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension, or withdrawal without notice.

Financing solutions from IBM Global Financing can help you stretch your budget and affordably acquire the new product. But beyond the initial acquisition, our end-to-end approach to IT management can also help keep your technologies current, reduce costs, minimize risk, and preserve your ability to make flexible equipment decisions throughout the entire technology lifecycle.

Trademarks

IBM Security is a trademark of IBM Corporation in the United States, other countries, or both.

IBM FlashSystem, IBM Spectrum, IBM FlashCore, IBM, Passport Advantage, Power, Global Technology Services, Easy Tier, MicroLatency, HyperSwap and FlashCopy are registered trademarks of IBM Corporation in the United States, other countries, or both.

Red Hat and OpenShift are registered trademarks of Red Hat Inc. in the U.S. and other countries.

Other company, product, and service names may be trademarks or service marks of others.

Terms of use

IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this announcement at any time without notice. This announcement is provided for your information only. Additional terms of use are located at

Terms of use

For the most current information regarding IBM products, consult your IBM representative or reseller, or go to the IBM worldwide contacts page

IBM United States