Multiple enhancements for IBM Power Systems I/O and servers are introduced

IBM United States Hardware Announcement 115-089
October 5, 2015

Table of contents
OverviewOverviewPublicationsPublications
Planned availability datePlanned availability dateTechnical informationTechnical information
DescriptionDescriptionTerms and conditionsTerms and conditions
Product numberProduct numberPricesPrices


Top rule
At a glance
Bottom rule

Power Systems™ enhancements include:

  • Power® S822 adds support for IBM® i partitions with special terms and conditions
  • Enhanced reliability, availability, and serviceability (RAS) for the PCIe Gen3 I/O Drawer
  • High voltage dc (HVDC) power supply options that enable Power servers to improve data center energy efficiency
  • Expanded configuration flexibility for existing PCIe adapters
    • 4-port 8Gb Fibre Channel Adapter (#EN12) on POWER8® servers
    • 2-port 10GbE NIC&RoCE Adapter (#EC2M, #EC2N, #EC37, #EC38, #EL3X, or #EL40) on POWER7+™ servers
    • Additional PCIe adapter support for Power E850
  • Support of LTO-7 tape drives in IBM Storage products such as the Removable Media Drawer



Back to topBack to top

Top rule
Overview
Bottom rule

Multiple Power Systems enhancements for both the server and server I/O are announced.

The Power S822 is enhanced with the ability to run IBM i with special terms and conditions. The new offering provides support for a very space-efficient footprint for IBM i clients with partitions of two or fewer cores using virtual I/O at a P10 software tier. Firmware 840 or later is required.

With the latest 8.4 firmware level, the PCIe Gen3 I/O Drawer has several RAS enhancements. I/O drawers can now be added to Power E870 or E880 while the server is running. Concurrent maintenance is also enhanced with the ability to service a Fan-out Module in a PCIe Gen3 I/O Drawer while the other Fan-out Module in that drawer continues to run for all models. Cable RAS is also enhanced, allowing the drawer to continue operation if either top or bottom cable is detached or fails for all models.

HVDC power supplies, HVDC power cords, and HVDC PDUs are now an option for the POWER8 system units and nodes and for the PCIe Gen3 I/O Drawer. Compared to typical 200-240 V ac power, using 380 V dc power can improve the energy efficiency in the data center by several percent for these devices. Note that ac power is required on the EXP24S disk/SSD drawer, HMC, and Multimedia drawer.

Two adapters previously available on POWER8 servers are given expanded configuration flexibility. The PCIe2 LP 8Gb 4-port Fibre Channel Adapter (#EN0Y), which was previously available only in low profile slots, is now also available as a full high adapter (#EN12) and available in many more PCIe slots. The PCIe3 2-port 10GbE NIC&RoCE SR Adapter (#EC2M, #EC2N, #EC37, #EC38, #EL3X, or #EL40) with NIM and Linux™ Network capability is now supported on POWER7+ servers.

In addition to the above #EN12 adapter, the Power E850 is expanding its PCIe adapter configuration flexibility. The previously announced #5708 10GbE Adapter and #EJ27 Crypto Adapter and #EC2N/EC38 10GbE NIC&RoCE Adapter are now supported on the Power E850.

The new LTO-7 tape drives available in IBM Storage products such as the 7226-1U3 Multimedia Storage Enclosure are supported by POWER8 servers. LTO-7 offers increased capacity and improved price performance.



Back to topBack to top

Top rule
Planned availability date
Bottom rule

October 30, 2015

Note: The PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter (#EC38, #EC37, #EL3X) and PCIe3 2-port 10GbE NIC&RoCE SR Adapter (#EC2N, #EC2M, #EL40) are not available in the following countries: Abu Dhabi, Algeria, Bahrain, Comoros, Djibouti, Dubai, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia, United Arab Emirates, and Yemen.



Back to topBack to top

Top rule
Description
Bottom rule


Power S822 supports IBM i

With firmware code level 840, the 2U Power S822 (8284-22A) supports IBM i 7.2 or IBM i 7.1 with special terms and conditions. Technology Refresh 3 or later for IBM i 7.2 or Technology Refresh 11 or later for IBM i 7.1 is required. Multiple IBM i partitions each up to a maximum of two cores are supported. IBM i partitions needing more than two cores can be run on a different model server. The Power S822 software tier is only P10.

Virtual I/O Server (VIOS) is required for all the I/O that IBM i accesses. There is no "native" IBM i support for I/O. Note that async or bisync adapters or crypto cards are not supported under VIOS. Thus IBM i applications requiring use of these adapters are not a good fit for the Power S822. Note IBM i 7.2 clients can connect to a LAN-attached OEM device that has downstream async connections. IBM i partitions accessing direct attached disk or SSD through VIOS must use 4k byte sector drives, not 5xx byte sector drives. The 4k drives are required for performance reasons.


PCIe Gen3 I/O Drawer RAS

The 8.4 firmware level provides the PCIe Gen3 I/O Drawer (feature #EMX0 or #ELMX) with expanded reliability, availability, and serviceability (RAS) capabilities.

All POWER8 models with firmware 8.4 are enhanced with the ability to concurrently service a Fan-out Module in a PCIe Gen3 I/O Drawer without taking the server down or taking down a Fan-out Module located in the same PCIe Gen3 I/O Drawer. After the service action is completed the Fan-out Module is returned to the server while the server is running. Note that when a Fan-out Module is being serviced, all six PCIe slots in the module are not available to the server.

All POWER8 models with firmware 8.4 are enhanced with the ability to disconnect either of the cables attaching a Fan-out Module to a system PCIe3 Optical Cable Adapter (#EJ05, #EJ07, or #EJ08). Previously only the top cable could be disconnected and still have the I/O drawer continue running. And previously restoring the configuration to full two-cable bandwidth required scheduled downtime of both sides of the I/O drawer (two Fan-out Modules). With firmware 8.4 the detached cable can be replaced or reattached while the system is running and scheduled downtime is required only for the one Fan-out Module with cabling changes to restore two-cable bandwidth.

The Power E870/E880 with firmware 8.4 can now concurrently add one or more PCIe3 Optical Cable Adapters (feature #EJ07) to a system node and one or more PCIe Gen3 I/O Drawers (feature #EMX0) with either one or two 6-Slot Fan-out Modules (EMXF) while the server is running. Other server models do not have this concurrent add capability. Note adding a second Fan-out Module to an already installed PCIe Gen3 I/O Drawer with only one Fan-out Module initially installed does not have concurrent add capability.


HVDC

Using high voltage dc (HVDC) power instead of ac power to run servers in a data center saves energy and avoids heat. The savings is not to the server or I/O drawer itself. The savings is to the data center since there are fewer conversions being done to the electrical power before being given to the HVDC servers and HVDC I/O. The amount of savings depends on how much electrical power is being used and on the voltage initially being brought into the data center and the efficiency of different ac components. Typical savings will be about 4.5% to 8% for HVDC equipment.

Power Systems adding this capability are the models S822, S814, S824, E850, E870, E880, S812L, S822L, and S824L. System units using HVDC need the appropriate HVDC power supplies (feature #EB2N , #EL1D, or #EBAD) instead of ac power supplies. HVDC power supply feature #EMXB is used for a PCIe Gen3 I/O Drawer. The ac and dc power supplies can not be mixed in the same system unit or CEC. But two different components of the same system, such as a CEC and an I/O drawer, can have different types of power.

Mixing of dc and ac power in the same rack must use grounding that is done in accordance with the applicable electrical code. IBM provides documentation for different ac and dc products as to their disconnecting means for service. Refer to that documentation to determine if the disconnecting means should differ. Mixing ac and dc in the same rack is atypical and given the possibility a client might easily incorrectly wire the grounding, IBM Manufacturing does not support integrating both ac and dc power in the same rack for client safety reasons. Note this might cause more than one rack to be configured in e-config if factory integration has been requested or it might cause some components to be shipped outside of a rack.

The HVDC power supply uses HVDC power cords and attaches to HVDC power distribution units (PDUs). Use feature #EPAD to select a 2.5-meter HVDC power cord for the server or I/O drawer. Or alternatively, use feature #EPAC to let IBM Manufacturing select an HVDC power cord (either 1.0 m, 1.5 m, or 2.5 m) for the server or I/O drawer.

The IBM Power Systems HVDC PDU feature code used depends on country-specific electrical codes (feature #EPAA or #EPAF). The PDU includes vertical mounting hardware for a rack side pocket or horizontal mounting hardware. Often horizontal mounting is preferred to provide better access to power cords and an optional horizontal mounting specify feature #EBA5 communicates this desire to IBM Manufacturing.


LTO-7

The new LTO-7 tape drives available in IBM Storage products such as the 7226-1U3 Multimedia Storage Enclosure are supported by POWER8 servers. LTO-7 offers more than 2X more capacity, providing approximately 6 TB vs the previous 2.5 TB LTO-6 capacity. This provides a lower cost per TB. The drive is attached using an 8Gb or 16Gb Fibre Channel adapter with a maximum bandwidth on Power Systems of 8 Gb.



Back to topBack to top

Top rule
Business Partner information
Bottom rule

If you are a Direct Reseller - System Reseller acquiring products from IBM, you may link directly to Business Partner information for this announcement. A PartnerWorld® ID and password are required (use IBM ID).

BP Attachment for Announcement Letter 115-089


Back to topBack to top

Top rule
Product number
Bottom rule

The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:

Planned Availability Date October 30, 2015

New Feature

Description                                       MT    Model   Feature
DC Power Supply - 1400W (180-400V)                8284  22A     EB2N 
                                                  8286  41A          
                                                  8286  42A          
                                                  8408  E8E          
HVDC PDU Horizontal Mounting                      7014  T00     EBA5 
                                                  7014  T42          
                                                  7965  94Y          
                                                  8247  21L          
                                                  8247  22L          
                                                  8247  42L          
                                                  8284  22A          
                                                  8286  41A          
                                                  8286  42A          
                                                  8408  E8E          
                                                  9119  MHE          
                                                  9119  MME          
DC Power Chunnels                                 9119  MHE     EBAD 
                                                  9119  MME          
DC Power Supply - 1400W (180-400V)                8247  21L     EL1D 
                                                  8247  22L          
                                                  8247  42L          
DC Power Supply Conduit for PCIe3 Expansion
Drawer                                            8247  21L     EMXB 
                                                  8247  22L          
                                                  8247  42L          
                                                  8284  22A          
                                                  8286  41A          
                                                  8286  42A          
                                                  8408  E8E          
                                                  9119  MHE          
                                                  9119  MME          
HVDC PDU - 90A 6xOutlet                           7014  T00     EPAA 
                                                  7014  T42          
                                                  7965  94Y          
                                                  8247  21L          
                                                  8247  22L          
                                                  8247  42L          
                                                  8284  22A          
                                                  8286  41A          
                                                  8286  42A          
                                                  8408  E8E          
                                                  9119  MHE          
                                                  9119  MME          
Auto Selected HVDC Power Cord                     8247  21L     EPAC 
                                                  8247  22L          
                                                  8247  42L          
                                                  8284  22A          
                                                  8286  41A          
                                                  8286  42A          
                                                  8408  E8E          
                                                  9119  MHE          
                                                  9119  MME          
2.5 Meter HVDC Power Cord                         8247  21L     EPAD 
                                                  8247  22L          
                                                  8247  42L          
                                                  8284  22A          
                                                  8286  41A          
                                                  8286  42A          
                                                  8408  E8E          
                                                  9119  MHE          
                                                  9119  MME          
HVDC PDU - 90A 6xOutlet Alternate Base            7014  T00     EPAF 
                                                  7014  T42          
Rack Content Specify 1U Horizontal PDU - 1 EIA    7965  94Y     ER14 

The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:

Planned Availability Date November 20, 2015

New Feature

Description                                       MT    Model   Feature
10Gb FCoE PCIe Dual Port Adapter                  8408  E8E     5708 
Lift Tool                                         8408  E8E     EB2Z 
OPAL with PowerKVM 3.1                            8247  21L     EC40 
                                                  8247  22L          
                                                  8247  42L          
PCIe Crypto Coprocessor No BSC 4765-001           8408  E8E     EJ27 
Quantity 150 of #EL1Q                             8247  42L     ELQQ 
PCIe2 8Gb 4-port Fibre Channel Adapter            8247  21L     EN12 
                                                  8247  22L          
                                                  8247  42L          
                                                  8284  22A          
                                                  8286  41A          
                                                  8286  42A          
                                                  8408  E8E          
                                                  9119  MHE          
                                                  9119  MME          
Rear rack extension                               8408  E8E     ERG0 

The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:

Planned Availability Date December 11, 2015

New Feature

Description                                       MT    Model   Feature
PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter         8202  E4D     EC2M 
                                                  8205  E6D          
                                                  8231  E1D          
                                                  8231  E2D     


                                                  8268  E1D         



PCIe3 2-port 10GbE NIC&RoCE SR Adapter            8202  E4D     EC2N 
                                                  8205  E6D          
                                                  8248  L4T          
                                                  8412  EAD          
                                                  9109  RMD          
                                                  9117  MMD          
                                                  9179  MHD          
PCIe3 2-port 10GbE NIC&RoCE SR Adapter            8408  E8D     EC2N 
PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper
Adapter                                           8202  E4D     EC37 
                                                  8205  E6D          
                                                  8231  E1D          
                                                  8231  E2D  


                                                  8268  E1D          



PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter   8202  E4D     EC38 
                                                  8205  E6D          
                                                  8248  L4T          
                                                  8412  EAD          
                                                  9109  RMD          
                                                  9117  MMD          
                                                  9179  MHD          
PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter   8408  E8D     EC38 
PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper
Adapter                                           8246  L1D     EL3X 
                                                  8246  L1T          
                                                  8246  L2D          
                                                  8246  L2T          
PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter         8246  L1D     EL40 
                                                  8246  L1T          
                                                  8246  L2D          
                                                  8246  L2T          

Feature conversions

The existing components being replaced during a model or feature conversion become the property of IBM and must be returned.

Feature conversions are always implemented on a "quantity of one for quantity of one" basis. Multiple existing features may not be converted to a single new feature. Single existing features may not be converted to multiple new features.

The following conversions are available to customers.

Feature conversions for 9119-MHE processor features:

                                                          Return
From FC:                     To FC:                       parts
ELJ6 - Power IFL Processor   ELJ8 - Power IFL Processor   No       
Activation                   Activation                  
EPBB - 4.35 GHz, 32-core     EPBD - 4.02 GHz 48-core      Yes      
POWER8 processor             POWER8 processor            
EPBK - 1 core Processor      EPBM - 1 core Processor      No       
Activation for #EPBB         Activation for #EPBD        
EPBP - 1 core Processor      EPBR - 1 core Processor      No       
Activation for #EPBB,        Activation for #EPBD,       
Mobile Eabled                Mobile Eabled               


Back to topBack to top

Top rule
Publications
Bottom rule

No publications are shipped with the announced products.

The IBM Publications Center Portal is located on

http://www.ibm.com/shop/publications/order

The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, which can currently be downloaded.



Back to topBack to top

Top rule
Services
Bottom rule

Global Technology Services

IBM services include business consulting, outsourcing, hosting services, applications, and other technology management.

These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an on-demand business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-IBM offerings. IBM is your one-stop shop for IT support needs.

For details on available services, contact your IBM representative or see

http://www.ibm.com/services/

For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or go to

http://www.ibm.com/services/continuity

For details on education offerings related to specific products, go to

http://www.ibm.com/services/learning/ites.wss/zz/en?pageType=tp_search_new


Back to topBack to top

Top rule
Technical information
Bottom rule

Specified operating environment

Physical specifications

For physical specifications, refer to the Sales Manual.

To assure installability and serviceability in non-IBM industry-standard racks, review the installation planning information for any product-specific installation requirements.

Planning information

Cable orders

No cables are required.

Security, auditability, and control

The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.



Back to topBack to top

Top rule
IBM Electronic Services
Bottom rule

IBM has transformed its delivery of hardware and software support services to help you achieve higher system availability. Electronic Services is a web-enabled solution that offers an exclusive, no-additional-charge enhancement to the service and support available for IBM servers. These services are designed to provide the opportunity for greater system availability with faster problem resolution and preemptive monitoring. Electronic Services comprises two separate, but complementary, elements: Electronic Services news page and Electronic Services Agent.

The Electronic Services news page is a single Internet entry point that replaces the multiple entry points traditionally used to access IBM Internet services and support. The news page enables you to gain easier access to IBM resources for assistance in resolving technical problems.

The Electronic Service Agent™ is no-additional-charge software that resides on your server. It monitors events and transmits system inventory information to IBM on a periodic, client-defined timetable. The Electronic Service Agent automatically reports hardware problems to IBM. Early knowledge about potential problems enables IBM to deliver proactive service that may result in higher system availability and performance. In addition, information collected through the Service Agent is made available to IBM service support representatives when they help answer your questions or diagnose problems. Installation and use of IBM Electronic Service Agent for problem reporting enables IBM to provide better support and service for your IBM server.

To learn how Electronic Services can work for you, see

http://www.ibm.com/support/electronic


Back to topBack to top

Top rule
Terms and conditions
Bottom rule


MES discount applicable

Equal to the volume commitment discount


Field-installable feature

Yes


Warranty period

To obtain copies of the IBM Statement of Limited Warranty, contact your reseller or IBM.

An IBM part or feature installed during the initial installation of an IBM machine is subject to the full warranty period specified by IBM. An IBM part or feature that replaces a previously installed part or feature assumes the remainder of the warranty period for the replaced part or feature. An IBM part or feature added to a machine without replacing a previously installed part or feature is subject to a full warranty. Unless specified otherwise, the warranty period, type of warranty service, and service level of a part or feature are the same as those for the machine in which it is installed.


Customer setup

Yes


Machine code

Same license terms and conditions as base machine



Back to topBack to top

Top rule
Prices
Bottom rule

The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:

                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 7014      number  number     support  CSU MES 
HVDC PDU Horizontal Mounting
                       T00     EBA5       Both     Yes No 
                       T42                Both     Yes No 
HVDC PDU - 90A 6xOutlet
                       T00     EPAA       Both     Yes No 
                       T42                Both     Yes No 
HVDC PDU 90A 6xOutlet Alt Base
                       T00     EPAF       Initial  N/A No 
                       T42                Initial  N/A No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 7965      number  number     support  CSU MES 
HVDC PDU Horizontal Mounting
                       94Y     EBA5       Both     Yes No 
HVDC PDU - 90A 6xOutlet
                       94Y     EPAA       Both     Yes No 
Specify 1U PDU - 1 EIA
                       94Y     ER14       Initial  N/A No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8202      number  number     support  CSU MES 
PCIe3 LP 2-port 10GbE NIC&R SR
                       E4D     EC2M       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE SR
                       E4D     EC2N       Both     Yes No 
PCIe3 LP 2-port 10GbE NIC&R Cu
                       E4D     EC37       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       E4D     EC38       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8205      number  numbers    support  CSU MES 
PCIe3 LP 2-port 10GbE NIC&R SR
                       E6D     EC2M       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE SR
                       E6D     EC2N       Both     Yes No 
PCIe3 LP 2-port 10GbE NIC&R Cu
                       E6D     EC37       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       E6D     EC38       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8231      number  number     support  CSU MES 
PCIe3 LP 2-port 10GbE NIC&R SR
                       E1D     EC2M       Both     Yes No 
                       E2D                Both     Yes No 
PCIe3 LP 2-port 10GbE NIC&R Cu
                       E1D     EC37       Both     Yes No 
                       E2D                Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8246      number  number     support  CSU MES 
PCIe3 LP 2-port 10GbE NIC&R CU
                       L1D     EL3X       Both     Yes No 
                       L1T                Both     Yes No 
                       L2D                Both     Yes No 
                       L2T                Both     Yes No 
PCIe3 LP 2-port 10GbE NIC&R SR
                       L1D     EL40       Both     Yes No 
                       L1T                Both     Yes No 
                       L2D                Both     Yes No 
                       L2T                Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8247      number  number     support  CSU MES 
HVDC PDU Horizontal Mounting
                       21L     EBA5       MES      Yes No 
                       22L                MES      Yes No 
                       42L                MES      Yes No 
Opal with PowerKVM 3.1
                       21L     EC40       Initial  N/A No 
                       22L                Initial  N/A No 
                       42L                Initial  N/A No 
DC  Power  Supply - 1400W
                       21L     EL1D       Both     Yes No 
                       22L                Both     Yes No 
                       42L                Both     Yes No 
DC  Power  Supply Conduit
                       21L     EMXB       Both     Yes No 
                       22L                Both     Yes No 
                       42L                Both     Yes No 
PCIe2 8Gb 4-port Fibre Channel
                       21L     EN12       Both     Yes No 
                       22L                Both     Yes No 
                       42L                Both     Yes No 
HVDC PDU - 90A 6xOutlet
                       21L     EPAA       MES      Yes No 
                       22L                MES      Yes No 
                       42L                MES      Yes No 
Auto Selected HVDC  Power  Cord
                       21L     EPAC       Initial  N/A No 
                       22L                Initial  N/A No 
                       42L                Initial  N/A No 
2.5 Meter HVDC  Power  Cord
                       21L     EPAD       Both     Yes No 
                       22L                Both     Yes No 
                       42L                Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8248      number  number     support  CSU MES 
PCIe3 2-port 10GbE NIC&RoCE SR
                       L4T     EC2N       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       L4T     EC38       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8268      number  number     support  CSU MES 
PCIe3 LP 2-port 10GbE NIC&R SR
                       E1D     EC2M       Both     Yes No 
PCIe3 LP 2-port 10GbE NIC&R Cu
                       E1D     EC37       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8284      number  number     support  CSU MES 
DC  Power  Supply - 1400W
                       22A     EB2N       Both     Yes No 
HVDC PDU Horizontal Mounting
                       22A     EBA5       MES      Yes No 
DC  Power  Supply Conduit
                       22A     EMXB       Both     Yes No 
PCIe2 8Gb 4-port Fibre Channel
                       22A     EN12       Both     Yes No 
HVDC PDU - 90A 6xOutlet
                       22A     EPAA       MES      Yes No 
Auto Selected HVDC  Power  Cord
                       22A     EPAC       Initial  N/A No 
2.5 Meter HVDC  Power  Cord
                       22A     EPAD       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8286      number  number     support  CSU MES 
DC  Power  Supply - 1400W
                       41A     EB2N       Both     Yes No 
                       42A                Both     Yes No 
HVDC PDU Horizontal Mounting
                       41A     EBA5       MES      Yes No 
                       42A                MES      Yes No 
DC  Power  Supply Conduit
                       41A     EMXB       Both     Yes No 
                       42A                Both     Yes No 
PCIe2 8Gb 4-port Fibre Channel
                       41A     EN12       Both     Yes No 
                       42A                Both     Yes No 
HVDC PDU - 90A 6xOutlet
                       41A     EPAA       MES      Yes No 
                       42A                MES      Yes No 
Auto Selected HVDC  Power  Cord
                       41A     EPAC       Initial  N/A No 
                       42A                Initial  N/A No 
2.5 Meter HVDC  Power  Cord
                       41A     EPAD       Both     Yes No 
                       42A                Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8408      number  number     support  CSU MES 
DC  Power  Supply - 1400W
                       E8E     EB2N       Both     Yes No 
Lift Tool
                       E8E     EB2Z       Both     Yes No 
HVDC PDU Horizontal Mounting
                       E8E     EBA5       MES      Yes No 
PCIe Crypto Coprocessor No BSC
                       E8E     EJ27       Both     Yes No 
DC  Power  Supply Conduit
                       E8E     EMXB       Both     Yes No 
PCIe2 8Gb 4-port Fibre Channel
                       E8E     EN12       Both     Yes No 
HVDC PDU - 90A 6xOutlet
                       E8E     EPAA       MES      Yes No 
Auto Selected HVDC  Power  Cord
                       E8E     EPAC       Initial  N/A No 
2.5 Meter HVDC  Power  Cord
                       E8E     EPAD       Both     Yes No 
Rear rack extension
                       E8E     ERG0       MES      Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8412      number  number     support  CSU MES 
PCIe3 2-port 10GbE NIC&RoCE SR
                       EAD     EC2N       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       EAD     EC38       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 9109      number  numbers    support  CSU MES 
PCIe3 2-port 10GbE NIC&RoCE SR
                       RMD     EC2N       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       RMD     EC38       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both/        RP  
Machine type 9117      number  number     support  CSU MES 
PCIe3 2-port 10GbE NIC&RoCE SR
                       MMD     EC2N       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       MMD     EC38       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 9119      number  number     support  CSU MES 
HVDC PDU Horizontal Mounting
                       MHE     EBA5       MES      Yes No 
                       MME                MES      Yes No 
DC  Power  Chunnels
                       MHE     EBAD       Both     Yes No 
                       MME                Both     Yes No 
DC  Power  Supply Conduit
                       MHE     EMXB       Both     Yes No 
                       MME                Both     Yes No 
PCIe2 8Gb 4-port Fibre Channel
                       MHE     EN12       Both     Yes No 
                       MME                Both     Yes No 
HVDC PDU - 90A 6xOutlet
                       MHE     EPAA       MES      Yes No 
                       MME                MES      Yes No 
Auto Selected HVDC  Power  Cord
                       MHE     EPAC       Initial  N/A No 
                       MME                Initial  N/A No 
2.5 Meter HVDC  Power  Cord
                       MHE     EPAD       Both     Yes No 
                       MME                Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 9179      number  number     support  CSU MES 
PCIe3 2-port 10GbE NIC&RoCE SR
                       MHD     EC2N       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       MHD     EC38       Both     Yes No 

The following are features already announced for the IBM Power Systems 8247 and 8408 machine types:

                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine type 8247      number  number     support  CSU MES 
Quantity 150 of #EL1Q
                       42L     ELQQ       Both     Yes No 
                                          Initial/         
                                          MES/             
Description            Model   Feature    Both         RP  
Machine Type 8408      number  number     support  CSU MES 
10Gb FCoE PCIe Dual Port Adapt
                       E8E     5708       Support  Yes No 
PCIe3 2-port 10GbE NIC&RoCE SR
                       E8D     EC2N       Both     Yes No 
PCIe3 2-port 10GbE NIC&RoCE Cu
                       E8D     EC38       Both     Yes No 

Feature conversions

Feature conversions for 9119-MHE processor features:

                                                    Parts    
From FC:                  To FC:                    returned  
 
ELJ6 - Power IFL          ELJ8 - Power IFL          No           
Processor Activation      Processor Activation     
EPBB - 4.35 GHz, 32-core  EPBD - 4.02 GHz 48-core   Yes          
POWER8 processor          POWER8 processor         
EPBK - 1 core Processor   EPBM - 1 core Processor   No           
Activation for #EPBB      Activation for #EPBD     
EPBP - 1 core Processor   EPBR - 1 core Processor   No           
Activation for #EPBB,     Activation for #EPBD,    
Mobile Eabled             Mobile Eabled            



Back to topBack to top

Top rule
Pricing terms
Bottom rule

Prices in the following PDF prices link are suggested list prices on day of announcement for the U.S. only. They are provided for your information only. Dealer prices may vary, and prices may also vary by country. IBM list price does not include tax or shipping and is subject to change without notice.

ENUS-115-089-LIST_PRICES_2015_10_05.PDF ENUS-115-089-LIST_PRICES_2015_10_05.PDF

Trademarks

Power Systems, POWER7+ and Electronic Service Agent are trademarks of IBM Corporation in the United States, other countries, or both.

Power, IBM, POWER8, PartnerWorld and Global Technology Services are registered trademarks of IBM Corporation in the United States, other countries, or both.

Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.

Other company, product, and service names may be trademarks or service marks of others.

Terms of use

IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this announcement at any time without notice. This announcement is provided for your information only. Additional terms of use are located on

Terms of use

For the most current information regarding IBM products, consult your IBM representative or reseller, or visit the IBM worldwide contacts page

http://www.ibm.com/planetwide/us/