Multiple enhancements for IBM Power Systems I/O and servers are introduced
IBM United States Hardware Announcement 115-089October 5, 2015
Table of contents | ||||||||||||||||
|
At a glance |
Power Systems enhancements include:
- Power® S822 adds support for IBM® i partitions with special terms and conditions
- Enhanced reliability, availability, and serviceability (RAS) for the PCIe Gen3 I/O Drawer
- High voltage dc (HVDC) power supply options that enable Power servers to improve data center energy efficiency
- Expanded configuration flexibility for existing PCIe adapters
- 4-port 8Gb Fibre Channel Adapter (#EN12) on POWER8® servers
- 2-port 10GbE NIC&RoCE Adapter (#EC2M, #EC2N, #EC37, #EC38, #EL3X, or #EL40) on POWER7+ servers
- Additional PCIe adapter support for Power E850
- Support of LTO-7 tape drives in IBM Storage products such as the Removable Media Drawer
Overview |
Multiple Power Systems enhancements for both the server and server I/O are announced.
The Power S822 is enhanced with the ability to run IBM i with special terms and conditions. The new offering provides support for a very space-efficient footprint for IBM i clients with partitions of two or fewer cores using virtual I/O at a P10 software tier. Firmware 840 or later is required.
With the latest 8.4 firmware level, the PCIe Gen3 I/O Drawer has several RAS enhancements. I/O drawers can now be added to Power E870 or E880 while the server is running. Concurrent maintenance is also enhanced with the ability to service a Fan-out Module in a PCIe Gen3 I/O Drawer while the other Fan-out Module in that drawer continues to run for all models. Cable RAS is also enhanced, allowing the drawer to continue operation if either top or bottom cable is detached or fails for all models.
HVDC power supplies, HVDC power cords, and HVDC PDUs are now an option for the POWER8 system units and nodes and for the PCIe Gen3 I/O Drawer. Compared to typical 200-240 V ac power, using 380 V dc power can improve the energy efficiency in the data center by several percent for these devices. Note that ac power is required on the EXP24S disk/SSD drawer, HMC, and Multimedia drawer.
Two adapters previously available on POWER8 servers are given expanded configuration flexibility. The PCIe2 LP 8Gb 4-port Fibre Channel Adapter (#EN0Y), which was previously available only in low profile slots, is now also available as a full high adapter (#EN12) and available in many more PCIe slots. The PCIe3 2-port 10GbE NIC&RoCE SR Adapter (#EC2M, #EC2N, #EC37, #EC38, #EL3X, or #EL40) with NIM and Linux Network capability is now supported on POWER7+ servers.
In addition to the above #EN12 adapter, the Power E850 is expanding its PCIe adapter configuration flexibility. The previously announced #5708 10GbE Adapter and #EJ27 Crypto Adapter and #EC2N/EC38 10GbE NIC&RoCE Adapter are now supported on the Power E850.
The new LTO-7 tape drives available in IBM Storage products such as the 7226-1U3 Multimedia Storage Enclosure are supported by POWER8 servers. LTO-7 offers increased capacity and improved price performance.
Planned availability date |
October 30, 2015
Note: The PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter (#EC38, #EC37, #EL3X) and PCIe3 2-port 10GbE NIC&RoCE SR Adapter (#EC2N, #EC2M, #EL40) are not available in the following countries: Abu Dhabi, Algeria, Bahrain, Comoros, Djibouti, Dubai, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia, United Arab Emirates, and Yemen.
Description |
Power S822 supports IBM i
With firmware code level 840, the 2U Power S822 (8284-22A) supports IBM i 7.2 or IBM i 7.1 with special terms and conditions. Technology Refresh 3 or later for IBM i 7.2 or Technology Refresh 11 or later for IBM i 7.1 is required. Multiple IBM i partitions each up to a maximum of two cores are supported. IBM i partitions needing more than two cores can be run on a different model server. The Power S822 software tier is only P10.
Virtual I/O Server (VIOS) is required for all the I/O that IBM i accesses. There is no "native" IBM i support for I/O. Note that async or bisync adapters or crypto cards are not supported under VIOS. Thus IBM i applications requiring use of these adapters are not a good fit for the Power S822. Note IBM i 7.2 clients can connect to a LAN-attached OEM device that has downstream async connections. IBM i partitions accessing direct attached disk or SSD through VIOS must use 4k byte sector drives, not 5xx byte sector drives. The 4k drives are required for performance reasons.
PCIe Gen3 I/O Drawer RAS
The 8.4 firmware level provides the PCIe Gen3 I/O Drawer (feature #EMX0 or #ELMX) with expanded reliability, availability, and serviceability (RAS) capabilities.
All POWER8 models with firmware 8.4 are enhanced with the ability to concurrently service a Fan-out Module in a PCIe Gen3 I/O Drawer without taking the server down or taking down a Fan-out Module located in the same PCIe Gen3 I/O Drawer. After the service action is completed the Fan-out Module is returned to the server while the server is running. Note that when a Fan-out Module is being serviced, all six PCIe slots in the module are not available to the server.
All POWER8 models with firmware 8.4 are enhanced with the ability to disconnect either of the cables attaching a Fan-out Module to a system PCIe3 Optical Cable Adapter (#EJ05, #EJ07, or #EJ08). Previously only the top cable could be disconnected and still have the I/O drawer continue running. And previously restoring the configuration to full two-cable bandwidth required scheduled downtime of both sides of the I/O drawer (two Fan-out Modules). With firmware 8.4 the detached cable can be replaced or reattached while the system is running and scheduled downtime is required only for the one Fan-out Module with cabling changes to restore two-cable bandwidth.
The Power E870/E880 with firmware 8.4 can now concurrently add one or more PCIe3 Optical Cable Adapters (feature #EJ07) to a system node and one or more PCIe Gen3 I/O Drawers (feature #EMX0) with either one or two 6-Slot Fan-out Modules (EMXF) while the server is running. Other server models do not have this concurrent add capability. Note adding a second Fan-out Module to an already installed PCIe Gen3 I/O Drawer with only one Fan-out Module initially installed does not have concurrent add capability.
HVDC
Using high voltage dc (HVDC) power instead of ac power to run servers in a data center saves energy and avoids heat. The savings is not to the server or I/O drawer itself. The savings is to the data center since there are fewer conversions being done to the electrical power before being given to the HVDC servers and HVDC I/O. The amount of savings depends on how much electrical power is being used and on the voltage initially being brought into the data center and the efficiency of different ac components. Typical savings will be about 4.5% to 8% for HVDC equipment.
Power Systems adding this capability are the models S822, S814, S824, E850, E870, E880, S812L, S822L, and S824L. System units using HVDC need the appropriate HVDC power supplies (feature #EB2N , #EL1D, or #EBAD) instead of ac power supplies. HVDC power supply feature #EMXB is used for a PCIe Gen3 I/O Drawer. The ac and dc power supplies can not be mixed in the same system unit or CEC. But two different components of the same system, such as a CEC and an I/O drawer, can have different types of power.
Mixing of dc and ac power in the same rack must use grounding that is done in accordance with the applicable electrical code. IBM provides documentation for different ac and dc products as to their disconnecting means for service. Refer to that documentation to determine if the disconnecting means should differ. Mixing ac and dc in the same rack is atypical and given the possibility a client might easily incorrectly wire the grounding, IBM Manufacturing does not support integrating both ac and dc power in the same rack for client safety reasons. Note this might cause more than one rack to be configured in e-config if factory integration has been requested or it might cause some components to be shipped outside of a rack.
The HVDC power supply uses HVDC power cords and attaches to HVDC power distribution units (PDUs). Use feature #EPAD to select a 2.5-meter HVDC power cord for the server or I/O drawer. Or alternatively, use feature #EPAC to let IBM Manufacturing select an HVDC power cord (either 1.0 m, 1.5 m, or 2.5 m) for the server or I/O drawer.
The IBM Power Systems HVDC PDU feature code used depends on country-specific electrical codes (feature #EPAA or #EPAF). The PDU includes vertical mounting hardware for a rack side pocket or horizontal mounting hardware. Often horizontal mounting is preferred to provide better access to power cords and an optional horizontal mounting specify feature #EBA5 communicates this desire to IBM Manufacturing.
LTO-7
The new LTO-7 tape drives available in IBM Storage products such as the 7226-1U3 Multimedia Storage Enclosure are supported by POWER8 servers. LTO-7 offers more than 2X more capacity, providing approximately 6 TB vs the previous 2.5 TB LTO-6 capacity. This provides a lower cost per TB. The drive is attached using an 8Gb or 16Gb Fibre Channel adapter with a maximum bandwidth on Power Systems of 8 Gb.
Business Partner information |
If you are a Direct Reseller - System Reseller acquiring products from IBM, you may link directly to Business Partner information for this announcement. A PartnerWorld® ID and password are required (use IBM ID).
Product number |
The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:
Planned Availability Date October 30, 2015
New Feature
Description MT Model Feature
DC Power Supply - 1400W (180-400V) 8284 22A EB2N 8286 41A 8286 42A 8408 E8E HVDC PDU Horizontal Mounting 7014 T00 EBA5 7014 T42 7965 94Y 8247 21L 8247 22L 8247 42L 8284 22A 8286 41A 8286 42A 8408 E8E 9119 MHE 9119 MME DC Power Chunnels 9119 MHE EBAD 9119 MME DC Power Supply - 1400W (180-400V) 8247 21L EL1D 8247 22L 8247 42L DC Power Supply Conduit for PCIe3 Expansion Drawer 8247 21L EMXB 8247 22L 8247 42L 8284 22A 8286 41A 8286 42A 8408 E8E 9119 MHE 9119 MME HVDC PDU - 90A 6xOutlet 7014 T00 EPAA 7014 T42 7965 94Y 8247 21L 8247 22L 8247 42L 8284 22A 8286 41A 8286 42A 8408 E8E 9119 MHE 9119 MME Auto Selected HVDC Power Cord 8247 21L EPAC 8247 22L 8247 42L 8284 22A 8286 41A 8286 42A 8408 E8E 9119 MHE 9119 MME 2.5 Meter HVDC Power Cord 8247 21L EPAD 8247 22L 8247 42L 8284 22A 8286 41A 8286 42A 8408 E8E 9119 MHE 9119 MME HVDC PDU - 90A 6xOutlet Alternate Base 7014 T00 EPAF 7014 T42 Rack Content Specify 1U Horizontal PDU - 1 EIA 7965 94Y ER14
The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:
Planned Availability Date November 20, 2015
New Feature
Description MT Model Feature
10Gb FCoE PCIe Dual Port Adapter 8408 E8E 5708 Lift Tool 8408 E8E EB2Z OPAL with PowerKVM 3.1 8247 21L EC40 8247 22L 8247 42L PCIe Crypto Coprocessor No BSC 4765-001 8408 E8E EJ27 Quantity 150 of #EL1Q 8247 42L ELQQ PCIe2 8Gb 4-port Fibre Channel Adapter 8247 21L EN12 8247 22L 8247 42L 8284 22A 8286 41A 8286 42A 8408 E8E 9119 MHE 9119 MME Rear rack extension 8408 E8E ERG0
The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:
Planned Availability Date December 11, 2015
New Feature
Description MT Model Feature
PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter 8202 E4D EC2M 8205 E6D 8231 E1D 8231 E2D 8268 E1D PCIe3 2-port 10GbE NIC&RoCE SR Adapter 8202 E4D EC2N 8205 E6D 8248 L4T 8412 EAD 9109 RMD 9117 MMD 9179 MHD PCIe3 2-port 10GbE NIC&RoCE SR Adapter 8408 E8D EC2N PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper Adapter 8202 E4D EC37 8205 E6D 8231 E1D 8231 E2D 8268 E1D PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter 8202 E4D EC38 8205 E6D 8248 L4T 8412 EAD 9109 RMD 9117 MMD 9179 MHD PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter 8408 E8D EC38 PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper Adapter 8246 L1D EL3X 8246 L1T 8246 L2D 8246 L2T PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter 8246 L1D EL40 8246 L1T 8246 L2D 8246 L2T
Feature conversions
The existing components being replaced during a model or feature conversion become the property of IBM and must be returned.
Feature conversions are always implemented on a "quantity of one for quantity of one" basis. Multiple existing features may not be converted to a single new feature. Single existing features may not be converted to multiple new features.
The following conversions are available to customers.
Feature conversions for 9119-MHE processor features:
Return From FC: To FC: parts
ELJ6 - Power IFL Processor ELJ8 - Power IFL Processor No Activation Activation EPBB - 4.35 GHz, 32-core EPBD - 4.02 GHz 48-core Yes POWER8 processor POWER8 processor EPBK - 1 core Processor EPBM - 1 core Processor No Activation for #EPBB Activation for #EPBD EPBP - 1 core Processor EPBR - 1 core Processor No Activation for #EPBB, Activation for #EPBD, Mobile Eabled Mobile Eabled
Publications |
No publications are shipped with the announced products.
The IBM Publications Center Portal is located on
The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, which can currently be downloaded.
Services |
Global Technology Services
IBM services include business consulting, outsourcing, hosting services, applications, and other technology management.
These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an on-demand business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-IBM offerings. IBM is your one-stop shop for IT support needs.
For details on available services, contact your IBM representative or see
For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or go to
For details on education offerings related to specific products, go to
Technical information |
Specified operating environment
Physical specifications
For physical specifications, refer to the Sales Manual.
To assure installability and serviceability in non-IBM industry-standard racks, review the installation planning information for any product-specific installation requirements.
Planning information
Cable orders
No cables are required.
Security, auditability, and control
The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.
IBM Electronic Services |
IBM has transformed its delivery of hardware and software support services to help you achieve higher system availability. Electronic Services is a web-enabled solution that offers an exclusive, no-additional-charge enhancement to the service and support available for IBM servers. These services are designed to provide the opportunity for greater system availability with faster problem resolution and preemptive monitoring. Electronic Services comprises two separate, but complementary, elements: Electronic Services news page and Electronic Services Agent.
The Electronic Services news page is a single Internet entry point that replaces the multiple entry points traditionally used to access IBM Internet services and support. The news page enables you to gain easier access to IBM resources for assistance in resolving technical problems.
The Electronic Service Agent is no-additional-charge software that resides on your server. It monitors events and transmits system inventory information to IBM on a periodic, client-defined timetable. The Electronic Service Agent automatically reports hardware problems to IBM. Early knowledge about potential problems enables IBM to deliver proactive service that may result in higher system availability and performance. In addition, information collected through the Service Agent is made available to IBM service support representatives when they help answer your questions or diagnose problems. Installation and use of IBM Electronic Service Agent for problem reporting enables IBM to provide better support and service for your IBM server.
To learn how Electronic Services can work for you, see
Terms and conditions |
MES discount
applicable
Equal to the volume commitment discount
Field-installable feature
Yes
Warranty
period
To obtain copies of the IBM Statement of Limited Warranty, contact your reseller or IBM.
An IBM part or feature installed during the initial installation of an IBM machine is subject to the full warranty period specified by IBM. An IBM part or feature that replaces a previously installed part or feature assumes the remainder of the warranty period for the replaced part or feature. An IBM part or feature added to a machine without replacing a previously installed part or feature is subject to a full warranty. Unless specified otherwise, the warranty period, type of warranty service, and service level of a part or feature are the same as those for the machine in which it is installed.
Customer
setup
Yes
Machine
code
Same license terms and conditions as base machine
Prices |
The following are newly announced features on the specific models of the IBM Power Systems 7014, 7965, 8202, 8205, 8231, 8246, 8247, 8248, 8268, 8284, 8286, 8408, 8412, 9109, 9117, 9119, and 9179 machine types:
Initial/ MES/ Description Model Feature Both RP Machine type 7014 number number support CSU MES
HVDC PDU Horizontal Mounting T00 EBA5 Both Yes No T42 Both Yes No HVDC PDU - 90A 6xOutlet T00 EPAA Both Yes No T42 Both Yes No HVDC PDU 90A 6xOutlet Alt Base T00 EPAF Initial N/A No T42 Initial N/A No
Initial/ MES/ Description Model Feature Both RP Machine type 7965 number number support CSU MES
HVDC PDU Horizontal Mounting 94Y EBA5 Both Yes No HVDC PDU - 90A 6xOutlet 94Y EPAA Both Yes No Specify 1U PDU - 1 EIA 94Y ER14 Initial N/A No
Initial/ MES/ Description Model Feature Both RP Machine type 8202 number number support CSU MES
PCIe3 LP 2-port 10GbE NIC&R SR E4D EC2M Both Yes No PCIe3 2-port 10GbE NIC&RoCE SR E4D EC2N Both Yes No PCIe3 LP 2-port 10GbE NIC&R Cu E4D EC37 Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu E4D EC38 Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8205 number numbers support CSU MES
PCIe3 LP 2-port 10GbE NIC&R SR E6D EC2M Both Yes No PCIe3 2-port 10GbE NIC&RoCE SR E6D EC2N Both Yes No PCIe3 LP 2-port 10GbE NIC&R Cu E6D EC37 Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu E6D EC38 Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8231 number number support CSU MES
PCIe3 LP 2-port 10GbE NIC&R SR E1D EC2M Both Yes No E2D Both Yes No PCIe3 LP 2-port 10GbE NIC&R Cu E1D EC37 Both Yes No E2D Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8246 number number support CSU MES
PCIe3 LP 2-port 10GbE NIC&R CU L1D EL3X Both Yes No L1T Both Yes No L2D Both Yes No L2T Both Yes No PCIe3 LP 2-port 10GbE NIC&R SR L1D EL40 Both Yes No L1T Both Yes No L2D Both Yes No L2T Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8247 number number support CSU MES
HVDC PDU Horizontal Mounting 21L EBA5 MES Yes No 22L MES Yes No 42L MES Yes No Opal with PowerKVM 3.1 21L EC40 Initial N/A No 22L Initial N/A No 42L Initial N/A No DC Power Supply - 1400W 21L EL1D Both Yes No 22L Both Yes No 42L Both Yes No DC Power Supply Conduit 21L EMXB Both Yes No 22L Both Yes No 42L Both Yes No PCIe2 8Gb 4-port Fibre Channel 21L EN12 Both Yes No 22L Both Yes No 42L Both Yes No HVDC PDU - 90A 6xOutlet 21L EPAA MES Yes No 22L MES Yes No 42L MES Yes No Auto Selected HVDC Power Cord 21L EPAC Initial N/A No 22L Initial N/A No 42L Initial N/A No 2.5 Meter HVDC Power Cord 21L EPAD Both Yes No 22L Both Yes No 42L Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8248 number number support CSU MES
PCIe3 2-port 10GbE NIC&RoCE SR L4T EC2N Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu L4T EC38 Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8268 number number support CSU MES
PCIe3 LP 2-port 10GbE NIC&R SR E1D EC2M Both Yes No PCIe3 LP 2-port 10GbE NIC&R Cu E1D EC37 Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8284 number number support CSU MES
DC Power Supply - 1400W 22A EB2N Both Yes No HVDC PDU Horizontal Mounting 22A EBA5 MES Yes No DC Power Supply Conduit 22A EMXB Both Yes No PCIe2 8Gb 4-port Fibre Channel 22A EN12 Both Yes No HVDC PDU - 90A 6xOutlet 22A EPAA MES Yes No Auto Selected HVDC Power Cord 22A EPAC Initial N/A No 2.5 Meter HVDC Power Cord 22A EPAD Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8286 number number support CSU MES
DC Power Supply - 1400W 41A EB2N Both Yes No 42A Both Yes No HVDC PDU Horizontal Mounting 41A EBA5 MES Yes No 42A MES Yes No DC Power Supply Conduit 41A EMXB Both Yes No 42A Both Yes No PCIe2 8Gb 4-port Fibre Channel 41A EN12 Both Yes No 42A Both Yes No HVDC PDU - 90A 6xOutlet 41A EPAA MES Yes No 42A MES Yes No Auto Selected HVDC Power Cord 41A EPAC Initial N/A No 42A Initial N/A No 2.5 Meter HVDC Power Cord 41A EPAD Both Yes No 42A Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8408 number number support CSU MES
DC Power Supply - 1400W E8E EB2N Both Yes No Lift Tool E8E EB2Z Both Yes No HVDC PDU Horizontal Mounting E8E EBA5 MES Yes No PCIe Crypto Coprocessor No BSC E8E EJ27 Both Yes No DC Power Supply Conduit E8E EMXB Both Yes No PCIe2 8Gb 4-port Fibre Channel E8E EN12 Both Yes No HVDC PDU - 90A 6xOutlet E8E EPAA MES Yes No Auto Selected HVDC Power Cord E8E EPAC Initial N/A No 2.5 Meter HVDC Power Cord E8E EPAD Both Yes No Rear rack extension E8E ERG0 MES Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 8412 number number support CSU MES
PCIe3 2-port 10GbE NIC&RoCE SR EAD EC2N Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu EAD EC38 Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 9109 number numbers support CSU MES
PCIe3 2-port 10GbE NIC&RoCE SR RMD EC2N Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu RMD EC38 Both Yes No
Initial/ MES/ Description Model Feature Both/ RP Machine type 9117 number number support CSU MES
PCIe3 2-port 10GbE NIC&RoCE SR MMD EC2N Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu MMD EC38 Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 9119 number number support CSU MES
HVDC PDU Horizontal Mounting MHE EBA5 MES Yes No MME MES Yes No DC Power Chunnels MHE EBAD Both Yes No MME Both Yes No DC Power Supply Conduit MHE EMXB Both Yes No MME Both Yes No PCIe2 8Gb 4-port Fibre Channel MHE EN12 Both Yes No MME Both Yes No HVDC PDU - 90A 6xOutlet MHE EPAA MES Yes No MME MES Yes No Auto Selected HVDC Power Cord MHE EPAC Initial N/A No MME Initial N/A No 2.5 Meter HVDC Power Cord MHE EPAD Both Yes No MME Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine type 9179 number number support CSU MES
PCIe3 2-port 10GbE NIC&RoCE SR MHD EC2N Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu MHD EC38 Both Yes No
The following are features already announced for the IBM Power Systems 8247 and 8408 machine types:
Initial/ MES/ Description Model Feature Both RP Machine type 8247 number number support CSU MES
Quantity 150 of #EL1Q 42L ELQQ Both Yes No
Initial/ MES/ Description Model Feature Both RP Machine Type 8408 number number support CSU MES
10Gb FCoE PCIe Dual Port Adapt E8E 5708 Support Yes No PCIe3 2-port 10GbE NIC&RoCE SR E8D EC2N Both Yes No PCIe3 2-port 10GbE NIC&RoCE Cu E8D EC38 Both Yes No
Feature conversions
Feature conversions for 9119-MHE processor features:
Parts From FC: To FC: returned ELJ6 - Power IFL ELJ8 - Power IFL No Processor Activation Processor Activation EPBB - 4.35 GHz, 32-core EPBD - 4.02 GHz 48-core Yes POWER8 processor POWER8 processor EPBK - 1 core Processor EPBM - 1 core Processor No Activation for #EPBB Activation for #EPBD EPBP - 1 core Processor EPBR - 1 core Processor No Activation for #EPBB, Activation for #EPBD, Mobile Eabled Mobile Eabled
Pricing terms |
Prices in the following PDF prices link are suggested list prices on day of announcement for the U.S. only. They are provided for your information only. Dealer prices may vary, and prices may also vary by country. IBM list price does not include tax or shipping and is subject to change without notice.
Trademarks
Power Systems, POWER7+ and Electronic Service Agent are trademarks of IBM Corporation in the United States, other countries, or both.
Power, IBM, POWER8, PartnerWorld and Global Technology Services are registered trademarks of IBM Corporation in the United States, other countries, or both.
Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.
Other company, product, and service names may be trademarks or service marks of others.
Terms of use
IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this announcement at any time without notice. This announcement is provided for your information only. Additional terms of use are located on
For the most current information regarding IBM products, consult your IBM representative or reseller, or visit the IBM worldwide contacts page