IBM Power System E950 server offers a unique blend of enterprise-class capabilities in a reliable, agile, space-efficient 4-socket 4U form factor that can deliver exceptional performance, and it is ideal for cloud deployments with built-in virtualization, flexible capacity, and high utilization
IBM United States Hardware Announcement 118-060August 7, 2018
Table of contents | ||||||||||||||||||||||||
|
Product number and Prices sections were revised.
(Corrected on November 21, 2019)
Changed length of CMC service in the Overview section.
Added IBM Proactive Support for Power Systems topic to Overview and Description sections.
The Description, Terms and conditions, and Product number sections were revised.
(Corrected on October 25, 2018)
Added prices.
(Corrected on August 29, 2018)
Revised the Description, Product structure - Ordering information, Terms and conditions, and Prices sections.
(Corrected on August 22, 2018)
Revised the Planned availability date section.
At a glance
The IBM® Power® System E950 server (9040-MR9) is an enhanced 4-socket, 4U server that provides a significant enhancement to IBM Power Systems 4-socket servers. It is ideal for cloud deployments with built-in virtualization, flexible capacity, and guaranteed utilization.
Summary of Power System E950 features:
- IBM POWER9
processor modules with 8, 10, 11, or 12
POWER9
processor cores
- 8-core processor modules provide up to 32 cores per system typical 3.6 - 3.8 GHz (max).
- 10-core processor modules provide up to 40 cores per system typical 3.4 - 3.8 GHz (max).
- 11-core processor modules provide up to 44 cores per system typical 3.2 - 3.8 GHz (max).
- 12-core processor modules provide up to 48 cores per system typical 3.15 - 3.8 GHz (max).
-
128 GB to 16 TB high-performance industry standard double data rate (ISDDR) memory
- A two-processor module configuration provides 64 ISDIMM slots.
- A four-processor module configuration provides 128 ISDIMM slots and a server maximum of 16 TB.
-
PCIe slots
- System unit supports up to 10 PCIe Gen4 slots.
- One PCIe Gen3 reserved for default Ethernet adapter.
- PCIe I/O Expansion Drawers support up to 48 additional PCIe slots.
-
Standard PCIe3 SAS controllers (#EJ0K) for internal disk bays
- Eight SFF (2.5 in.) SAS bays for HDDs or SSDs
- Four NVMe U.2 bays
- Integrated USB controller provides two front and two rear USB ports. External DVD plugs into front USB port.
-
Additional storage can be attached.
- Up to 1,536 SFF-2 bays for HDDs and SSDs with 64 EXP24SX or EXP12SX I/O drawers
- Fibre Channel and LAN adapters
- Elastic capacity on demand for both cores and memory
- Power to Cloud Rewards
- Active Memory Expansion and Active Memory Mirroring for Hypervisor
- Packaged in a standard 19-inch rack-mount 4U drawer
- Support for IBM AIX® and Linux® operating systems
Overview
IBM Power Systems for enterprise combines cloud management with leadership performance, scale, availability, and security to cloud enable the most data-intensive, mission-critical workloads.
The new Power System E950 server has built-in virtualization, flexible capacity, and high utilization, ideal for growing, medium-size businesses and as a departmental server or data center building block for large enterprises. Built with the new POWER9 architecture, the E950 provides improvements in application delivery and IT services through increased throughput, reduced response times, and increased memory and I/O bandwidths.
With its built-in virtualization and an ecosystem of open cloud solutions, you can cloud-enable any workload without migration and build a cloud that handles the most data-intensive workloads on earth on either a private, hybrid, or multicloud platform.
- Help reduce your operating costs and increase efficiency by consolidating your older, underutilized servers with the new compact, energy-efficient 4U form factor of the Power E950 server with its single backplane and single cooling domain.
- Help reduce maintenance and increase resource utilization and efficiency with up to 48 POWER9 cores and up to 16 TB DDR4 memory (4x more than IBM POWER8® E850C).
- Help enable more agile IT that rapidly adjusts to the demands of an ever-changing business environment. IBM PowerVM® supports dynamic response to workload changes and seamlessly provisions processor or memory capacity permanently, or only as long as required, with capacity on demand for processors and memory.
This new server generation has quadruple the memory footprint of POWER8 servers, making it an ideal platform for in-memory and data-centric applications. Changes in the memory subsystem and the use of industry standard memory DIMMs take POWER9 technology to the next level of balancing affordability and performance. Designed to run commercial, cognitive, and database workloads, POWER9 technology provides a highly competitive server platform. Client references indicate POWER® servers help provide a robust and secure backbone for their IT infrastructure. More companies are using POWER technology in their IT infrastructure, from large data center down to shop level deployments.
By default, the Power Management mode of the Power E950 server is set to Max Performance. This mode can dynamically optimize the processor frequency at any given time based on CPU utilization and operating environmental conditions.
The IBM Power System E950 server offers Elastic Capacity on Demand (Elastic CoD) for both cores and memory, Active Memory Expansion, and Active Memory Mirroring for Hypervisor. The E950 server supports AIX and Linux operating systems and IBM PowerVM Enterprise. The Power System E950 server is a logical follow-on to the IBM Power System E850 and E850C servers.
Each Power System E950 server includes the following additional software and services:
- Cloud Management Console (CMC) for IBM Power Systems - CMC is a cloud-native platform that provides apps that give powerful insights into your Power Systems infrastructure across data centers and geographies. With no additional software or infrastructure setup, get single pane of glass views of your inventory, software levels, resource capacity utilization, as well as launch-in-context of your on-prem software such as PowerVC and PowerHA® . Each new Power E950 server purchase includes 12 months of CMC service, which can be renewed. For more information, see IBM Cloud Management Console website.
-
Open source cloud automation and configuration tooling for
AIX
.
IBM
has expanded its commitment to keep key open source cloud management packages updated and to provide timely security fixes to enable clients to leverage open source skills.
Power
System E950 server clients can take advantage of key packages recently provided to enable cloud automation, including:
- chef automation for configuration, deployment, and management. IBM is collaborating with clients in this community to provide useful resources for using chef with AIX systems.
- yum package management is available with repository access from both ftp and https protocols. rpm is also updated to enable automatic dependency discovery.
- cloud-init and all dependencies are available in the repository and includes support for licensed AIX users. For more information, see the AIX Toolbox for Linux Applications website.
- Securely connect system-of-record workloads and data-to-cloud native applications. IBM API Connect® and IBM WebSphere® Connect provide secure connectivity to cloud-based applications, giving clients the ability to rapidly develop new applications and services, thereby helping accelerate their time to value. IBM 's Power to Cloud services can help clients get started with these solutions and in designing new applications that leverage IBM Cloud . Cloud enables clients to rapidly build, deploy, and manage their cloud applications, while tapping a growing ecosystem of available services and runtime frameworks.
- IBM Power to Cloud Reward Program. The IBM Power to Cloud Reward Program helps clients design, build, and deliver cloud platforms on Power Systems . Clients purchasing an Power System E950 server earn 5,000 IBM Power to Cloud Reward Program points per system. The points can be used for a range of services to transform traditional IT platforms to private and hybrid cloud platforms. Power to Cloud Reward Program services offerings leverage the proven expertise of IBM Systems Lab Services consultants. For additional details, see the IBM Power to Cloud Reward Program website or contact your IBM representative, IBM Business Partner, or ibmsls@us.ibm.com.
Power System E950 hardware components
The Power System E950 server delivers a high-performing and reliable 4-socket system in the marketplace, with simultaneous multithreading of up to eight threads per core (SMT8). Each Power System E950 server's POWER9 single-chip module has two on-chip memory controllers and utilizes up to 128 MB off-chip eDRAM L4 cache to deliver 230 GB/sec of memory bandwidth per socket. I/O bandwidth is also increased to double that of the predecessor POWER8 systems with the introduction of PCIe Gen4 integrated controllers.
The new Power System E950 server utilizes 8-core, 10-core, 11-core, or 12-core POWER9 processor modules and delivers a system with up to 32 cores typical 3.6 - 3.8 GHz (max), up to 40 cores typical 3.4 - 3.8 GHz (max), up to 44 cores typical 3.2 - 3.8 GHz (max), or up to 48 cores typical 3.15 - 3.8 GHz (max). A minimum of two processor modules must be installed in each system, with a minimum quantity of one processor module's cores activated.
An Power System E950 server can utilize 8 GB, 16 GB, 32 GB, 64 GB, or 128 GB DDR4 ISDIMMs (up to 16 industry standard (IS) DIMMs per socket) to enable a maximum configuration of 16 TB. A minimum of 50% or 128 GB, whichever is higher, of installed memory must be activated.
The PCIe capabilities provide up to eight PCIe Gen4 x16, two PCIe Gen4 x8, and one PCIe Gen3 x8. PCIe slots support concurrent maintenance (hot plug). Additional PCIe adapters can be attached through up to four PCIe I/O Expansion Drawers, providing up to 48 additional PCIe Gen3 slots.
Each Power System E950 server has eight SFF (2.5 in.) SAS bays for HDDs or SSDs, plus four NVMe 2.5-inch bays. One or two PCIe SAS adapters support these SAS bays. One of these SAS options must be selected:
- DASD Backplane with no HDD/SDD drive selected. No PCIe SAS adapter is required.
- Base DASD backplane together with one SAS PCIe adapter and select SAS drives.
- Split DASD backplane together with two SAS PCIe adapters and select SAS drives.
NVMe drive options can be selected with any of the above SAS options
All SAS bays support concurrent maintenance (hot plug). In addition to the eight internal drives, more HDD or SSD drives can be attached through EXP24SX or EXP12SX expansion drawers.
The external USB DVD plugs into one of the two front USB ports.
Every Power System E950 server comes standard with phase-redundant, power regulators for processors, memory, disk, and I/O. Hot-plug, redundant power supplies and a hot-plug Time of Day battery are also standard, and Active Memory Mirroring for Hypervisor is available as an option.
IBM Proactive Support for Power Systems
Clients have found significant value in IBM's Proactive Support offerings on mission-critical systems, as this provides personalized support, proactive recommendations, and accelerated response times versus standard support. As a result, IBM is including the IBM Proactive Support in the default configuration for all Mid-Range and Enterprise IBM POWER9 Systems - for IBM AIX, IBM i, Linux, and SAP HANA workloads. Other configurations are also available.
Feature exchange
Not applicable.
Key prerequisites
One of the following operating systems:
- AIX
- Linux : Red Hat Enterprise Linux (RHEL) or SUSE Linux Enterprise Server (SLES)
For more information, see the Software requirements section.
Planned availability date
August 17, 2018, with the following limitations per system:
- EMX0 Initial/MES/Both max = 2
- EMXG Initial/MES/Both max = 4
November 16, 2018, for the following features per system:
- EMX0 Initial/MES/Both max = 4
Description
Summary of features
The following features are available on the Power System E950 server:
-
The
Power
System E950 server
supports 16 to 48 processor cores with two or four
POWER9
processor modules:
- 8-core processor modules provide up to 32 cores per system typical 3.6 - 3.8 GHz (max).
- 10-core processor modules provide up to 40 cores per system typical 3.4 - 3.8 GHz (max).
- 11-core processor modules provide up to 44 cores per system typical 3.2 - 3.8 GHz (max).
- 12-core processor modules provide up to 48 cores per system typical 3.15 - 3.8 GHz (max).
-
128 GB - 16 TB high-performance DDR4 memory with L4 cache:
- 8 GB ISDIMM Memory (#EM6A)
- 16 GB ISDIMM Memory (#EM6B)
- 32 GB ISDIMM Memory (#EM6C)
- 64 GB ISDIMM Memory (#EM6D)
- 128 GB ISDIMM Memory (#EM6E)
- Optional Active Memory Expansion (#EMAM)
-
Choice of three storage backplane features. Each
Power
E950 server has eight SFF (2.5 in.) SAS bays for HDDs or SSDs, plus four NVMe 2.5-inch bays. One or two PCIe SAS adapter support these SAS bays. One of these SAS options must be selected:
- DASD Backplane with no HDD/SDD drive selected. No PCIe SAS adapter is required (#EJ0B).
- Base DASD backplane together with one SAS PCIe adapter and select SAS drives (#EJBB).
- Split DASD backplane together with two SAS PCIe adapters and select SAS drive (#EJSB).
-
Up to 11 hot-swap PCIe slots in the system unit:
- Four, six, or eight x16 Gen4 full-height, half-length slots.
- Two x8 Gen4 full height, half-length slots.
- One x8 Gen3 full-height, half-length slot generally is used for an Ethernet adapter.
- With two processor modules, there are seven PCIe slots; with three modules, there are nine PCIe slots; and with four modules, there are eleven PCIe slots in the system unit.
-
The PCIe I/O Expansion Drawer (#EMX0) expands the number of full-high, hot-swap slots:
- Up to two PCIe drawers with two processor modules (maximum 31 slots on the server)
- Up to four PCIe drawers with four processor modules (maximum 51 slots on the server)
- Up to 64 EXP24SX SFF (#ESLS) or EXP12SX LFF (#ESLL) Drawers can be attached, providing up to 1,536 SAS bays for disks or SSDs.
-
System unit I/O (integrated I/O)
- USB ports: four 3.0 (two front) for general use and 2.0 (rear) for limited use
- HMC ports: two 1 GbE RJ45
- System (serial) port: one RJ45
- Four hot-plug and redundant power supplies 2000 W (200 - 240 V AC) (#EB3M)
- System unit only 4U in a 19-inch rack-mount hardware
-
Primary operating systems:
- AIX (#2146) (small-tier licensing)
- Linux (#2147): RHEL, SLES, and Ubuntu
Processor modules
-
The
Power
E950 server supports 16 to 48 processor cores:
- 8-core typical 3.6 - 3.8 GHz (max) #EPWR POWER9 Processor
- 10-core typical 3.4 - 3.8 GHz (max) #EPWS POWER9 Processor
- 11-core typical 3.2 - 3.8 GHz (max) #EPWY POWER9 Processor
- 12-core typical 3.15 - 3.8 GHz (max) #EPWT POWER9 Processor
- A minimum of two and a maximum of four processor modules are required for each system. The modules can be added to a system at a later time through an MES order, but will require scheduled downtime to install. All processor modules in one server must be the same gigahertz (same processor module feature number). They cannot be mixed.
-
Permanent CoD processor core activations are required for the first processor module in the
configuration and are optional for the second and fourth modules. Specifically:
- Two or four 8-core, typical 3.6 - 3.8 GHz (max) processor modules (#EPWR) require eight processor core activations (#EPWV) at a minimum.
- Two or four 10-core, typical 3.4 - 3.8 GHz (max) processor modules (#EPWS) require ten processor core activations (#EPWW) at a minimum.
- Two or four 11-core, typical 3.2 - 3.8 GHz (max) processor modules (#EPWY) require eleven processor core activations (#EPN3) at a minimum.
- Two or four 12-core, typical 3.15 - 3.8 GHz (max) processor modules (#EPWT) require twelve processor core activations (#EPWX) at a minimum.
-
Temporary CoD capabilities are optionally used for processor cores that are not permanently
activated:
- 90 Days Elastic CoD Processor Core Enablement (#EP9T).
- 1 and 100 Processor Day Elastic CoD billing for #EPWR (#EPN0, #EPN1).
- 1 and 100 Processor Day Elastic CoD billing for #EPWS (#EPN5, #EPN6).
- 1 and 100 Processor Day Elastic CoD billing for #EPWY (#EPN8, #EPN9).
- 1 and 100 Processor Day Elastic CoD billing for #EPWT (#EPNK, #EPNL).
- 100 Processor-minutes Utility CoD billing: for #EPWR (#EPN2), for #EPWS (#EPN7), for #EPWY (#EPNN) or for #EPWT (#EPNM).
- An HMC is required for temporary CoD.
Notes :
- A minimum of two processor features is required on each system.
- Mixing of different processor features on the same system is not allowed.
System memory
-
128 GB - 16 TB high-performance 1600 MHz DDR4 ECC memory with L4 cache:
- 8 GB ISDIMM Memory (#EM6A)
- 16 GB ISDIMM Memory (#EM6B)
- 32 GB ISDIMM Memory (#EM6C)
- 64 GB ISDIMM Memory (#EM6D)
- 128 GB ISDIMM Memory (#EM6E)
-
As the client memory requirements increase, the system capabilities are increased as follows:
- With two processor modules installed, 64 ISDIMM slots are available; minimum memory is 128 GB.
- With four modules, 128 ISDIMM slots are available; minimum memory is 256 GB. Thirty two ISDIMMs are available per socket.
-
The more ISDIMM slots that are filled, the larger the available bandwidth available to the
server.
Permanent CoD memory activations are required for at least 50% of the physically installed memory or 128 GB of activations, whichever is larger. Use 1 GB activation (#EMAP) and 100 GB activation (#EMAQ) features to order permanent memory activations.
-
Temporary CoD for memory is available for memory capacity that is not permanently activated:
- 90 Days Elastic CoD Memory Enablement (#EM9U).
- 8 GB-Day billing for Elastic CoD memory (#EMJE).
- 800 GB-Day billing for Elastic CoD memory (#EMJF).
- An HMC is required.
Temporary CoD Memory Days can also be acquired through IBM Marketplace after system installation. For more information about new Elastic CoD features, see the IBM Digital MarketPlace website.
Notes :
- Memory is ordered in quantity of 8 of the same memory feature.
- Second memory riser card of each processor can have different ISDIMM capacity from that on first riser but it is recommended that the second riser card has the same type and size DIMMs as the first riser card. It is also recommended that the amount of memory per processor should be the same or about the same.
- A minimum of one memory riser with eight ISDIMMs for each installed POWER9 processor is required.
- The minimum memory supported per two POWER9 processors installed is 128 GB.
- The minimum memory supported per four POWER9 processors installed is 256 GB.
I/O support
PCIe slots
The Power System E950 server has up to 10 PCIe Gen4 and 1 PCIOe Gen3 general purpose hot-plug slots, providing configuration flexibility and expandability. Eight adapter slots are x16 Gen4, two adapter slots are x8 Gen4, and one adapter slot x8 Gen3 (generally reserved for base Ethernet adapter). All adapter slots are full height, half length.
The number of slots supported vary by the number of processor modules.
Processor modules | 2 socket | 4 socket |
---|---|---|
x16 Gen4 slots (CAPI capable) | 4 | 8 |
x8 Gen4 slots | 2 | 2 |
x8 Gen3 slots | 1 | 1 |
Notes :
- The PCIe Gen3 slot, C6, is reserved for an Ethernet adapter to help ensure proper manufacture and test of the server.
- Blind-swap cassettes (BSC) are used for adapters in the system unit.
- All PCIe slots in the system unit are SR-IOV capable.
- PCIe slot C12 must contain the SAS RAID adapter (#EJ0K) when controlling the Base internal SAS drive bays. The SAS RAID adapter in this slot will not support a Dual Storage Adapter configuration.
- PCIe slots C12 and C9 must each contain a SAS RAID controller (#EJ0K) when controlling the Split internal SAS drive bays. The SAS RAID adapters in these slots will not support a Dual Storage Adapter configuration.
The x16 slots can provide up to twice the bandwidth of x8 slots because they offer twice as many PCIe lanes. PCIe Gen4 slots can support up to twice the bandwidth of a PCIe Gen3 slot and up to four times the bandwidth of a PCIe Gen2 slot, assuming an equivalent number of PCIe lanes. PCIe Gen1, PCIe Gen2, PCIe Gen3, and PCIe Gen4 adapters can be plugged into a PCIe Gen4 slot, if that adapter is supported. The x16 slots can be used to attach PCI Gen3 I/O Expansion drawers.
This server is smarter than earlier servers about energy efficiency for cooling the PCIe adapter environment. They can sense which IBM PCIe adapters are installed in their PCIe slots. If an adapter is known to require higher levels of cooling, they automatically speed up fans to increase airflow across the PCIe adapters.
SAS bays and storage backplane options
Clients have a choice of three storage features. Each Power E950 server has eight SFF (2.5 in.) SAS bays for HDDs or SSDs, plus four NVMe 2.5-inch bays. One or two PCIe SAS adapter support these SAS bays. One of these SAS options must be selected:
- DASD Backplane with no HDD/SDD drive selected. No PCIe SAS adapter is required (#EJ0B)
- Base DASD backplane together with one SAS PCIe adapter and select SAS drives (#EJBB)
- Split DASD backplane together with two SAS PCIe adapters and select SAS drive (#EJSB)
NVMe drive options can be selected with any of the above SAS options.
The base and the split backplane options provides SFF-3 SAS bays in the system unit. These 2.5-inch or small form factor (SFF) SAS bays can contain SAS drives (HDD or SSD) mounted on a tray or carrier. Thus, any drives that are designated for SFF-1, or SFF-2 bays do not fit in an SFF-3 bay. All SFF-3 bays support concurrent maintenance or hot-plug capability. These backplane options support HDDs or SSDs or a mixture of HDDs and SSDs in the SFF-3 bays. If mixing HDDs and SSDs, they must be in separate arrays.
The base and the split options can offer different drive protection options: RAID 0, RAID 5, RAID 6, or RAID 10. RAID 5 requires a minimum of three drives of the same capacity. RAID 6 requires a minimum of four drives of the same capacity. RAID 10 requires a minimum of two drives. Hot spare capability is supported with RAID 5, RAID 6, or RAID 10.
Note:
- All three of these backplane options are supported by AIX , Linux , and VIOS. It is highly recommended that the drives be protected, but not required. If the client needs a change after the server is already installed, the backplane option can be changed. Scheduled downtime is required to remove the existing storage backplane and install a different backplane.
USB DVD external and boot devices
Power System 9040-MR9 provides two front USB ports, mainly to support the external USB DVD.
System boot is supported through these options:
- NVMe drives
- Internal SAS drives
- Disk or SSD located in an EXP24SX or EXP12SX drawer attached to a PCIe SAS adapter
- A network through LAN adapters
- A SAN attached to Fibre Channel or FCoE adapters and indicated to the server by the 0837 specify code
- USB front port for external USB based DVD
- USB front port for USB memory key / flash drive
Assuming option 1 above, the minimum system configuration requires at least one NVMe disk drive in the system for AIX and Linux . If you are not using option 1 or 2 above, an internal disk is not required.
I/O drawer attachment
Clients migrating from earlier generation servers may have been using I/O drawers such as the GX++ attached feature 5802 or 5877 PCIe 12X I/O Drawers with PCIe Gen1 slots. Though most PCIe adapters in the feature 5802 or 5877 drawers can be moved to this server and its disk drives converted and moved to the feature ESLS EXP24SX drawer, the feature 5802 and 5877 drawers are not supported on this newer Power Systems technology-based server. Similarly, the GX++ attached EXP30 Ultra SSD Drawer (#EDR1 or #5888) is not supported.
Up to 64 EXP24SX or EXP12SX storage drawers can be attached to a Power System E950 server. With 24 drives per drawer, this means up to 1,536 SFF-2 drives are supported. A maximum of 16 EXP24SX per PCIe Gen3 I/O drawer is supported due to cable management considerations.
The older 3.5-inch-based EXP12S SAS Disk Drawer (#5886) and EXP24 SCSI Disk Drawer (#5786) are not supported.
IBM offers a 1U multimedia drawer that can hold one or more DVDs, tape drive, or RDX docking stations. The 7226-1U3 is the most current offering. The earlier 7216-1U2 and 7214-1U2 are also supported. Up to six of these multimedia drawers can be attached.
PCIe I/O Expansion Drawer
PCIe I/O Expansion Drawers (#EMX0) can be attached to the system unit to expand the number of full-high, hot-swap slots available to the server. The maximum number of PCIe I/O drawers depends on the number of processor modules physically installed. The maximum is independent of the number of processor core activations.
- Up to two PCIe drawers with two processor modules.
- Up to four PCIe drawers with four processor modules.
- The 19-inch 4 EIA (4U) PCIe I/O Expansion Drawer (#EMX0) and two PCIe fanout modules (#EMXG) provide 12 PCIe I/O full-length, full-height slots. One fanout module provides six PCIe slots labeled C1 through C6. Slots C1 and C4 are x16 slots, and C2, C3 , C5, and C6 are x8 slots. Slots C1 and C4 of the 6-slot fanout module in a PCIe Gen3 I/O drawer are SR-IOV enabled.
- An EMX0 drawer can be configured with one or two EMXG fanout modules. Adding a second fanout module is not a hot-plug operation and requires scheduled downtime.
- PCIe Gen1, Gen2, and Gen3 full-high adapter cards are supported. The set of full-high PCIe adapters that are supported is found in the Sales Manual, identified by feature number. See the PCI Adapter Placement manual for the 9040-MR9 for details and rules associated with specific adapters supported and their supported placement in x8 or x16 slots.
- Each fanout module requires one PCIe Cable Adapter (#EJ08), which is placed in a x16 PCIe slot of the system unit.
- A cable pair attaches the PCIe Cable Adapter (#EJ08) to the fanout module. Feature ECC7 provides a pair of 3-meter optical cables with transceivers. Feature ECC8 provides a pair of 10-meter optical cables with transceivers. Feature ECCS provides a pair of 3-meter copper cables. Two cables of identical length, or one feature, is required for each fanout module. Optical cables are smaller diameter and more flexible and can be longer than the copper cables. Copper cables are lower cost. Copper and optical cables have the same performance and reliability characteristics.
- The cable adapter (#EJ08) can be placed in any of the system units' available x16 slots and attached to any fanout module in any of the server's PCIe I/O drawers (#EMX0). The PCIe I/O drawer cannot be shared by two different servers.
- Recommendation: Locate any attached PCIe I/O Expansion Drawer in the same rack as the POWER9 server for ease of service. But the drawers can be installed in separate racks if the application or other rack content requires it. It is recommended to use 3-meter cables for PCIe drawers in the same rack as the system unit and 10-meter cables for drawers located in a different rack.
- Concurrent repair and add/removal of PCIe adapter cards is done by HMC-guided menus or by operating system support utilities.
- When the operating system is Linux , PowerVM is required for support of the I/O Expansion Drawer.
Rack cable brackets
The cable bracket is used to secure the communications cables so that they can be raised to remove the blind swap cassettes containing the PCIe adapters. To enable the server to be pulled forward on its rails for service access to memory, processors, and voltage regulator modules requires the disconnecting the cables from the server.
Integrated I/O ports
There are two HMC ports, one system port, and four USB ports (two general purpose and two limited use).
The two HMC ports are located on the service processor in the rear of the server and are RJ45. These ports support 1 Gb Ethernet connections leveraging the second-generation service processor technology called an FSP2 in some IBM publications.
The one integrated system or serial port has an RJ45 style connector and is supported by AIX and Linux for attaching serial devices such as an asynchronous device like a console. If the device does not have an RJ45 connection, a converter cable such as feature 3930 can provide a 9-pin, D-shell connection. Note that serial devices can have very individual characteristics (different pin outs), and the feature 3930 may not be appropriate for all possible devices. In this case, the user should acquire an OEM converter cable appropriate for their device.
Integrated system port is not supported under AIX or Linux when the HMC ports are connected to an HMC. Either the HMC ports or the integrated system ports can be used, but not both. The integrated system port is supported for modem and TTY terminal connections by AIX or Linux . Any other application using serial ports requires a serial port adapter to be installed in a PCI slot. The integrated system port does not support HACMP configurations.
Two USB-3 ports are located on the front of the server for general client use, and two USB-3 ports on the rear are for limited client use. A converter cable, feature ECCF, provides a USB-to-9-pin D-Shell connection to some UPS. The IBM 9910 Uninterruptible Power Systems , models E66 and E67, are supported as purchase options with the 9040-MR9.
Racks
The IBM Power System E950 server is designed to fit a standard 19-inch rack. IBM Development has tested and certified the system for the following rack support:
- 7965-S42 (42U) (Field integration only)
- 7014-T42 (42U) (Field integration only)
Clients can choose to place the server in other racks if they are confident those racks have the strength, rigidity, depth, and hole-pattern characteristics that are needed. Clients should work with IBM Service to determine the appropriateness of other racks. The Power System E950 rails can adjust their depth to fit a rack that is 22.75 inches - 30.5 inches in depth based on the adjustable outer brackets going from the front rail to the rear rail. Racks from IBM include:
- 7014-T00 (36U) (Support only, cannot be ordered from IBM )
IBM Manufacturing does not support the use of other racks with the Power E950 initial system order or model upgrade. The 7965-S42 (#ECR0) and 7014-T42 (#0553) are 2-meter enterprise racks that provide 42U or 42 EIA of space.
Additional E950 PCIe I/O drawers (#EMX0) for an already installed server can be MES ordered with or without a rack.
Typical good cable management practices apply. For example, it is usually a good practice to leave 1U or 2U open at the top or bottom of the rack for cables exiting the rack or to hold extra cable lengths. Or if you have more than four PCIe I/O drawers in the same rack, carefully consider how many 4-port PCIe adapters have cables attached to all their ports. If you are not using something like the 8-inch extension for a 7965-S42 rack for extra space to lay the cables, service access can be a challenge, especially with thicker I/O cables. Or another example, if there are a lot of I/O cables in the rack, horizontally mounting the power distribution units (PDUs) versus mounting them vertically in the side pockets eases service access.
Rack front door options supported are the acoustic door (#6248 or #6249), the attractive geometrically accented door (#ERG7), and the cost-effective plain front door (#6068 or #6069). The front trim kit is also supported (#6263 or #6272).
Power distribution units
Using previously provided IBM PDU features 7188, 7109, and 7196 reduces the number of Power System E950 servers and other equipment that can be held most efficiently in a rack. The high-function PDUs provide more electrical power per PDU and thus offer better "PDU footprint" efficiency. In addition, they are intelligent PDUs that provide insight to actual power usage by receptacle and also provide remote power on/off capability for easier support by individual receptacle. The new PDUs are features EPTJ, EPTL, EPTN, and EPTQ.
IBM Manufacturing will only integrate the newer PDUs with the Power System E950 server. IBM Manufacturing does not support integrating earlier PDUs such as the feature 7188, 7109, or 7196. Clients can choose to use older IBM PDUs in their racks, but will have to install those earlier PDUs at their site.
1-phase or 3-phase wye depending on country wiring standards | 3-phase 208 V depending on country wiring standards | |
---|---|---|
Nine C19 receptacles | EPTJ | EPTL |
Twelve C13 receptacles | EPTN | EPTQ |
- High Function 9xC19 PDU: Switched, Monitoring (#EPTJ). This is an intelligent, switched 200 - 240 V AC PDU with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack, making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. Depending on country wiring standards, the PDU is single-phase or three-phase wye. The PDU can be mounted vertically in rack side pockets, or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One country-specific wall line cord is also ordered separately and attaches to a UTG524-7 connector on the front of the PDU. Supported line cords include features 6489, 6491, 6492, 6653, 6654, 6655, 6656, 6657, 6658, and 6667.
- High Function 9xC19 PDU 3-Phase: Switched, Monitoring (#EPTL). This is an intelligent, switched 208 V 3-phase AC PDU with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack, making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. The PDU can be mounted vertically in rack side pockets, or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One wall line cord is provided with the PDU (no separate feature number) and has an IEC60309 60A plug (3P+G). The PDU supports up to 48 amps. Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password, and IBM strongly urges clients to change it upon installation.
- High Function 12xC13 PDU: Switched, Monitoring (#EPTN). This is an intelligent, switched 200 - 240 V AC PDU with twelve C13 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack, making the twelve C13 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. Depending on country wiring standards, the PDU is single-phase or three-phase wye. The PDU can be mounted vertically in rack side pockets, or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. Device power cords with a C14 plug connect to C13 PDU receptacles and are ordered separately. One country-specific wall line cord is also ordered separately and attaches to a UTG524-7 connector on the front of the PDU. Supported line cords include features 6489, 6491, 6492, 6653, 6654, 6655, 6656, 6657, 6658, and 6667. Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password, and IBM strongly urges clients to change it upon installation.
- High Function 12xC13 PDU 3-Phase: Switched, Monitoring (#EPTQ). This is an intelligent, switched 208 V 3-phase AC PDU with twelve C13 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack, making the twelve C13 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. The PDU can be mounted vertically in rack side pockets, or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. Device power cords with a C14 plug connect to C13 PDU receptacles and are ordered separately. One wall line cord is provided with the PDU (no separate feature number) and has a IEC60309 60A plug (3P+G). The PDU supports up to 48 amps. Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password, and IBM strongly urges clients to change it upon installation.
Lifting considerations
Three to four service personnel are required to manually remove or insert a system unit into a rack, given its dimensions and weight and content. To avoid the need for this many people to assemble at a client site for a service action, a lift tool can be very useful. Similarly, if the client has chosen to install this CSU (customer setup) system, similar lifting considerations apply.
The Power System E950 server has a maximum weight of 70.3 kg (155 lb). However, by temporarily removing the power supplies, fans, and RAID assembly, the weight is easily reduced to a maximum of 55 kg (121 lb).
When lowering the Power System E950 server onto its rails in the rack, the server must be tilted on one end about 15 degrees so that the pins on the server enclosure fit onto the rails. This equates to lifting one end of the server about 4 cm (1.6 in.). This can be done using a tip plate on a lift tool or manually adjusting the load on a lift tool or tilting during the manual lift. Consider the optional feature EB2Z Lift Tool.
PowerVM Enterprise Edition License Entitlement is now included with each Power System E950 server.
PowerVM Enterprise Edition is available as a hardware feature (#EPVV) and supports up to 20 partitions per core, VIOS, and multiple shared processor pools. It also offers Live Partition Mobility, Active Memory Sharing, and PowerVP performance monitoring.
Other PowerVM technologies include:
- System Planning Tool simplifies the process of planning and deploying Power Systems LPARs and virtual I/O.
- Virtual I/O Server (VIOS) is a single-function appliance that resides in an Power System partition. It facilitates the sharing of physical I/O resources between AIX , Linux , and client partitions within the server. VIOS provides shared Ethernet adapter (SEA) virtual I/O to client LPARs.
- Virtual SCSI (VSCSI) enables the sharing of physical storage adapters (Fibre Channel) and storage devices (disk and optical) between logical partitions.
- With virtual networking, a SEA enables connectivity between internal and external virtual LANs (VLANs); virtual Ethernet provides high-speed connections between partitions.
With Live Partition Mobility, you can move a running AIX or Linux VMs from one physical server to another with no downtime. Use this capability to:
- Evacuate workloads from a system before performing scheduled maintenance.
- Move workloads across a pool of different physical resources as business needs shift.
- Move workloads away from underutilized machines so that they can be powered off to save on energy and cooling costs.
- Move your workloads to new POWER8 systems for upgrades without having to schedule an outage. With Active Memory Sharing, memory is dynamically moved between running partitions for optimal resource usage.
Active Memory Expansion
Active Memory Expansion is an innovative technology supporting the AIX operating system that helps enable the effective maximum memory capacity to be larger than the true physical memory maximum. Compression/decompression of memory content can enable memory expansion up to 100% or more. This can enable a partition to do significantly more work or support more users with the same physical amount of memory. Similarly, it can enable a server to run more partitions and do more work for the same physical amount of memory.
Active Memory Expansion uses CPU resource to compress/decompress the memory contents. The trade-off of memory capacity for processor cycles can be an excellent choice, but the degree of expansion varies on how compressible the memory content is. It also depends on having adequate spare CPU capacity available for this compression/decompression.
POWER9 chips include a hardware accelerator designed to boost Active Memory Expansion efficiency and use less POWER core resource. The POWER9 accelerator includes some minor enhancements and also leverages POWER9 higher bandwidth and lower latency characteristics.
You have a great deal of control over Active Memory Expansion usage. Each individual AIX partition can turn on or turn off Active Memory Expansion. Control parameters set the amount of expansion desired in each partition to help control the amount of CPU used by the Active Memory Expansion function. An IPL is required for the specific partition that is turning on memory expansion. When turned on, monitoring capabilities are available in standard AIX performance tools such as lparstat, vmstat, topas, and svmon.
A planning tool is included with AIX , enabling you to sample actual workloads and estimate both how expandable the partition's memory is and how much CPU resource is needed. Any Power Systems model can run the planning tool. In addition, a one-time, 60-day trial of Active Memory Expansion is available to enable more exact memory expansion and CPU measurements. You can request the trial using the Power Systems Capacity on Demand web page.
Active Memory Expansion is enabled by chargeable hardware feature EMAM, which can be ordered with the initial order of the system node or as an MES order. A software key is provided when the enablement feature is ordered, which is applied to the system node. An IPL is not required to enable the system node. The key is specific to an individual system node and is permanent. It cannot be moved to a different server.
The additional CPU resource used to expand memory is part of the CPU resource assigned to the AIX partition running Active Memory Expansion. Normal licensing requirements apply.
Capacity on demand
Several types of capacity on demand (CoD) processors are optionally available for the Power System E950 server. They help meet changing resource requirements in an on demand environment by using resources installed on the system but not activated.
Capacity upgrade on demand (CUoD) enables you to purchase additional permanent processor or memory capacity and dynamically activate it when needed.
There are two ways clients can order Elastic capacity on demand (Elastic CoD). With IBM Marketplace, clients can now order and provision Elastic CoD in minutes through the web. For more information about new Elastic CoD features, see the IBM Digital MarketPlace website.
An additional way to order Elastic COD is through e-config features
Elastic CoD enables processors or memory to be temporarily activated in full-day increments as needed. Charges are based on usage reporting collected monthly. Processors and memory can be activated and turned off an unlimited number of times, whenever you want additional processing resources.
With this offering, system administrators have an interface at the HMC to manage the activation and deactivation of resources. A monitor that resides on the server logs the usage activity. You must send this usage data to IBM monthly. A bill is then generated based on the total amount of processor and memory resources utilized, in increments of processor and memory (8 GB) days. Before using temporary capacity on your server, you must enable your server. To do this, order an enablement feature (MES only) and sign the required contracts.
Use the following features to order activation features and support billing charges on the Power E950 (9040-MR9) server:
Processor module feature | Elastic CoD processor enablement feature | Elastic CoD AIX / Linux processor billing feature (1 and 100 proc-day) |
---|---|---|
EPWR (8-core module) | EP9T | EPN0, EPN1 |
EPWS (10-core module) | EP9T | EPN5, EPN6 |
EPWY (11-core module) | EP9T | EPN8, EPN9 |
EPWT (12-core module) | EP9T | EPNK, EPNL |
Memory feature | Elastic CoD memory enablement feature | Elastic CoD memory billing feature (8 and 800 GB-day) |
---|---|---|
EM8P (16 GB) | EM9U | EMJE, EMJF |
EM8Q (32 GB) | EM9U | EMJE, EMJF |
EM8R (64 GB) | EM9U | EMJE, EMJF |
EM8S (128 GB) | EM9U | EMJE, EMJF |
Note: After CoD contracts are in place, inactive processor cores and inactive memory can be enabled for Elastic CoD usage.
The Elastic CoD processor consists of three steps: enablement, activation, and billing
-
Elastic CoD enablement: Description
Before requesting temporary capacity on a server, you must enable it for Elastic CoD. To do this, order a no-charge enablement feature (MES only) and sign the required contracts or click to accept the terms on the CoD website. IBM will generate an enablement code, mail it to you, and post it on the web for you to retrieve and enter on your server. A processor enablement code lets you request up to 90 processor days of temporary unused CoD processor capacity for all your processor cores that have not been permanently activated. For example, if you have 16 processor cores that are not permanently activated, the processor enablement code allows up to 1,440 processor days (16 x 90). If you have reached or are about to reach the limit of 90 processor days per nonactivated processor core, obtain another enablement code through the web or by placing an order for another processor enablement code to reset the number of days you can request. Similarly, a memory enablement code lets you request up to 90 days of temporary unused CoD memory capacity for all your gigabytes of memory that have not been permanently activated. For example, if you had 100 GB of memory that was not permanently activated, the memory enablement code allows up to 9000 GB memory days (100 x 90). If you have reached the limit of 90 memory days per nonactivated memory, obtain another memory enablement code to reset the number of days you can request. Note that one 90-day enablement can be used over many months (more than three months) assuming your usage is modest.
See the Power Systems Capacity on Demand website for additional detail.
-
Elastic activation requests:
When Elastic CoD temporary capacity is needed, simply use the HMC menu for Elastic CoD and specify how many of the inactive processors or how many gigabytes of memory you would like temporarily activated for some number of days. You will be billed for the days requested, whether the capacity is assigned to partitions or left in the shared processor pool. At the end of the temporary period (days you requested), you must ensure the temporarily activated capacity is available to be reclaimed by the server (not assigned to partitions) or you will be billed for any processor days not returned (per the contract you signed).
-
Elastic CoD billing:
When the Elastic CoD is enabled, you are required to report billing data at least once a month (whether there is activity or not). This data is used to determine the proper amount to bill at the end of each billing period (calendar quarter). Failure to report billing data for use of temporary processor or memory capacity during a billing quarter will result in default billing equivalent to 90 processor days of temporary capacity. The sales channel will be notified of client requests for temporary capacity. As a result, the sales channel must order a quantity of billing features (using the appropriate billing features for each billable processor and memory day reported less any outstanding credit balance of processor and memory days).
For more information regarding registration, enablement, and usage of Elastic CoD, see the Power Systems Capacity on Demand website.
Note: Previously, Elastic CoD was called On/Off CoD. Some documentation still refers to this capability as "On/Off."
Utility CoD
Utility CoD provides additional processor performance on a temporary basis within the shared processor pool. Utility CoD enables you to place a quantity of inactive processors into the system node's shared processor pool, which then becomes available to the pool's resource manager. When the system node recognizes that the combined processor utilization within the shared pool exceeds 100% of the level of base (purchased/active) processors assigned across uncapped partitions, then a Utility CoD Processor Minute is charged and this level of performance is available for the next minute of use. If additional workload requires a higher level of performance, the system will automatically enable the additional Utility CoD processors to be used. The system continuously monitors and charges for the performance needed above the base (permanent) level. Registration and usage reporting for Utility CoD is made using a public website, and payment is based on reported usage. Utility CoD requires PowerVM Enterprise Edition to be active on the 9040-MR9.
Processor module feature | Utility CoD billing feature 100 processor minutes |
---|---|
EPWR (8-core module) | EPN2 |
EPWS (10-core module) | EPN7 |
EPWY (11-core module) | EPNN |
EPWT (12-core module) | EPNM |
For more information regarding registration, enablement, and use of Utility CoD, go to the Utility Capacity on Demand website.
Trial capacity on demand (Trial CoD): You can request either a standard or an exception trial at the Trial Capacity on Demand website.
Software licensing
For software licensing considerations with the various CoD offerings, see the latest revision of the Capacity on Demand Planning Guide at the Power Systems Capacity on Demand website.
IBM Power System E950 Solution Edition for Healthcare
The IBM Power System E950 Solution Edition for Healthcare provides a cost-effective 48-core/512 GB processor and memory activation feature package for eligible healthcare industry clients running approved ISV applications; for example, Epic.
- Solution Edition for Healthcare 12-core typical 3.15 - 3.8 GHz processor (#EHC4)
- Base Processor Activations (12) for #EHC4 (#ELAN)
- Base Memory Activation (128 GB) for #EHC4 (#EMAN)
The Power E950 Solution Edition for Healthcare minimum requirement is a server with 4x typical 3.15 - 3.8 GHz processor modules, 48 cores (all active), and 512 GB memory (all active).
Note: Additional hardware components can be added as desired following normal supported configuration rules.
For eligibility rules and registration of the Power Solution Edition for Healthcare by the sales channel, go to the IBM Power Solution Editions for healthcare website.
Reliability, Availability, and Serviceability
Reliability
The reliability of systems starts with components, devices, and subsystems that are designed to be highly reliable. During the design and development process, subsystems go through rigorous verification and integration testing processes. During system manufacturing, systems go through a thorough testing process ensure product quality.
Power System E950 System RAS
Every Power System E950 server comes standard with phase-redundant power regulators for processors and memory. The memory regulators supply power to the DIMM memory riser cards and several processor voltage domains. Hot-plug, redundant power supplies and a concurrent maintenance of real time clock battery are also standard, and Active Memory Mirroring for Hypervisor is available as an option.
Processor VRM and Memory VRM are pluggable. Standby VRM and IO VRM also come with phase redundancy and are pluggable.
Power E950 comes with dual line cord redundancy along with n+1 power supply redundancy, also has n+1 fan rotor redundancy.
Memory subsystem RAS
The memory has error detection and correction circuitry designed such that the failure of any one specific DRAM module within an ECC word by itself can be corrected absent any other fault. The ECC word spans two DIMMs. In addition, there is a spare DRAM module per rank per DIMM pair.
Mutual surveillance
The service processor monitors the operation of the firmware during the boot process and also monitors the hypervisor for termination. The hypervisor monitors the service processor and reports a service reference code when it detects surveillance loss. In the PowerVM environment, it will perform a reset/reload if it detects the loss of the service processor.
Environmental monitoring functions
The Power Systems family does ambient and over temperature monitoring and reporting.
POWER9 processor functions
As in POWER8 , the POWER9 processor has the ability to do processor instruction retry for some transient errors as well as provide core-contained checkstops for certain solid faults.
Cache availability
The L2 and L3 caches in the POWER9 processor in the memory buffer chip are protected with double-bit detect, single-bit correct error detection code (ECC). In addition, a threshold of correctable errors detected on cache lines can result in the data in the cache lines being purged and the cache lines removed from further operation without requiring a reboot in the PowerVM environment.
Modified data would be handled through Special Uncorrectable Error handling. L1 data and instruction caches also have a retry capability for intermittent errors and a cache set delete mechanism for handling solid failures.
Special Uncorrectable Error handling
Special Uncorrectable Error (SUE) handling prevents an uncorrectable error in memory or modified cache data from immediately causing the system to terminate. Rather, the system tags the data and determines whether it will ever be used again. If the error is irrelevant, it will not force a check stop. When and if data is used, I/O adapters controlled by an I/O hub controller would freeze if data were transferred to an I/O device, otherwise termination may be limited to the program/kernel or the if data is not owned by the hypervisor;
Uncorrectable error recovery
When the auto-restart option is enabled, the system can automatically restart following an unrecoverable software error, hardware failure, or environmentally induced (AC power) failure.
Serviceability
The purpose of serviceability is to efficiently repair the system while attempting to minimize or eliminate impact to system operation. Serviceability includes system installation, MES (system upgrades/downgrades), and system maintenance/repair. Depending upon the system and warranty contract, service may be performed by the client, an IBM representative, or an authorized warranty service provider.
The serviceability features delivered in this system help provide a highly efficient service environment by incorporating the following attributes:
- Design for Customer Set Up (CSU), Customer Installed Features (CIF), and Customer Replaceable Units (CRU)
- Error Detection and Fault Isolation (ED/FI)
- First Failure Data Capture (FFDC)
- Lightpath service indicators
- Service labels and service diagrams available on the system and delivered through IBM Knowledge Center
- Step-by-step service procedures documented in IBM Knowledge Center or available through the Hardware Management Console
- Automatic reporting of serviceable events to IBM through the Electronic Service Agent Call Home application
- CRU videos planned to be available on the web at general availability
- Mobile access to important customer service functions available by scanning a QR label
Service environment
In the PowerVM environment, the HMC is a dedicated server that provides functions for configuring and managing servers for either partitioned or full-system partition using a GUI or command-line interface (CLI) or REST API. An HMC attached to the system enables support personnel (with client authorization) to remotely, or locally to the physical HMC that is in proximity of the server being serviced, log in to review error logs and perform remote maintenance if required.
The POWER9 processor-based platforms support several service environments:
- Attachment to one or more HMCs or vHMCs is a supported option by the system with PowerVM . This is the default configuration for servers supporting logical partitions with dedicated or virtual I/O. In this case, all servers have at least one logical partition.
-
For non-HMC systems.
- Full-system partition with PowerVM : A single partition owns all the server resources and only one operating system may be installed. The primary service interface is through the operating system and the service processor.
Service interface
Support personnel can use the service interface to communicate with the service support applications in a server using an operator console, a graphical user interface on the management console or service processor, or an operating system terminal. The service interface helps to deliver a clear, concise view of available service applications, helping the support team to manage system resources and service information in an efficient and effective way. Applications available through the service interface are carefully configured and placed to give service providers access to important service functions.
Different service interfaces are used, depending on the state of the system, hypervisor, and operating environment. The primary service interfaces are:
- LEDs
- Operator Panel
- Service Processor menu
- Operating system service menu
- Service Focal Point on the HMC or vHMC with PowerVM
In the light path LED implementation, the system can clearly identify components for replacement by using specific component-level LEDs, and can also guide the servicer directly to the component by signaling (turning on solid) the amber system fault LED, enclosure fault LED, and component FRU fault LED. The servicer can also use the identify function to blink the FRU-level LED. When this function is activated, a roll-up to the blue enclosure locate and system locate LEDs will occur. These enclosure LEDs will turn on solid and can be used to follow the light path from the system to the enclosure and down to the specific FRU in the PowerVM environment.
First Failure Data Capture and error data analysis
First Failure Data Capture (FFDC) is a technique that helps ensure that when a fault is detected in a system, the root cause of the fault will be captured without the need to re-create the problem or run any sort of extending tracing or diagnostics program. For the vast majority of faults, a good FFDC design means that the root cause can also be detected automatically without servicer intervention.
FFDC information, error data analysis, and fault isolation are necessary to implement the advanced serviceability techniques that enable efficient service of the systems and to help determine the failing items.
In the rare absence of FFDC and Error Data Analysis, diagnostics are required to re-create the failure and determine the failing items.
Diagnostics
General diagnostic objectives are to detect and identify problems so they can be resolved quickly. Elements of IBM 's diagnostics strategy include:
- Provide a common error code format equivalent to a system reference code with PowerVM , system reference number, checkpoint, or firmware error code.
- Provide fault detection and problem isolation procedures. Support remote connection ability to be used by the IBM Remote Support Center or IBM Designated Service.
- Provide interactive intelligence within the diagnostics with detailed online failure information while connected to IBM 's back-end system.
Automatic diagnostics
The processor and memory FFDC technology is designed to perform without the need for recreate diagnostics nor require user intervention. Solid and intermittent errors are designed to be correctly detected and isolated at the time the failure occurs. Runtime and boot-time diagnostics fall into this category.
Stand-alone diagnostics with PowerVM
As the name implies, stand-alone or user-initiated diagnostics requires user intervention. The user must perform manual steps, including:
- Booting from the diagnostics CD, DVD, USB, or network
- Interactively selecting steps from a list of choices
Concurrent maintenance
The determination of whether a firmware release can be updated concurrently is identified in the readme information file that is released with the firmware. An HMC is required for the concurrent firmware update with PowerVM . In addition, concurrent maintenance of PCIe adapters is supported with PowerVM . Concurrent maintenance of the Operator Panel is supported through ASMI. Additional concurrent maintenance includes power supplies, fans, and HDD/SSD drives.
Service labels
Service providers use these labels to assist them in performing maintenance actions. Service labels are found in various formats and positions and are intended to transmit readily available information to the servicer during the repair process. Following are some of these service labels and their purpose:
- Location diagrams: Location diagrams are located on the system hardware, relating information regarding the placement of hardware components. Location diagrams may include location codes, drawings of physical locations, concurrent maintenance status, or other data pertinent to a repair. Location diagrams are especially useful when multiple components such as DIMMs, CPUs, processor books, fans, adapter cards, LEDs, and power supplies are installed.
- Remove/replace procedures: Service labels that contain remove/replace procedures are often found on a cover of the system or in other spots accessible to the servicer. These labels provide systematic procedures, including diagrams detailing how to remove or replace certain serviceable hardware components.
- Arrows: Numbered arrows are used to indicate the order of operation and the serviceability direction of components. Some serviceable parts such as latches, levers, and touch points need to be pulled or pushed in a certain direction and in a certain order for the mechanical mechanisms to engage or disengage. Arrows generally improve the ease of serviceability.
QR labels
QR labels are placed on the system to provide access to key service functions through a mobile device. When the QR label is scanned, it will go to a landing page specific to that server which contains many of the service functions of interest while physically located at the server. These include things such as installation and repair instructions, service diagrams, reference code look up, and so on.
Packaging for service
The following service enhancements are included in the physical packaging of the systems to facilitate service:
- Color coding (touch points): Blue-colored touch points delineate touchpoints on service components where the component can be safely handled for service actions such as removal or installation.
- Tool-less design: Selected IBM systems support tool-less or simple tool designs. These designs require no tools or simple tools such as flathead screw drivers to service the hardware components.
- Positive retention: Positive retention mechanisms help to assure proper connections between hardware components such as cables to connectors, and between two cards that attach to each other. Without positive retention, hardware components run the risk of becoming loose during shipping or installation, preventing a good electrical connection. Positive retention mechanisms like latches, levers, thumb-screws, pop Nylatches (U-clips), and cables are included to help prevent loose connections and aid in installing (seating) parts correctly. These positive retention items do not require tools.
Error handling and reporting
In the event of system hardware or environmentally induced failure, the system runtime error capture capability systematically analyzes the hardware error signature to determine the cause of failure. The analysis result will be stored in system NVRAM. When the system can be successfully restarted either manually or automatically, or if the system continues to operate, the error will be reported to the operating system. Hardware and software failures are recorded in the system log. When an HMC is attached in the PowerVM environment, an ELA routine analyzes the error, forwards the event to the Service Focal Point (SFP) application running on the HMC, and notifies the system administrator that it has isolated a likely cause of the system problem. The service processor event log also records unrecoverable checkstop conditions, forwards them to the SFP application, and notifies the system administrator.
The system has the ability to call home through the operating system to report platform-recoverable errors and errors associated with PCI adapters/devices.
In the HMC-managed environment, a call home service request will be initiated from the HMC and the pertinent failure data with service parts information and part locations will be sent to an IBM service organization. Customer contact information and specific system-related data such as the machine type, model, and serial number, along with error log data related to the failure, are sent to IBM Service.
Live Partition Mobility
With PowerVM Live Partition Mobility (LPM), users can migrate an AIX , IBM i or Linux VM running on one POWER system to another POWER system without disrupting services. The migration transfers the entire system environment, including processor state, memory, attached virtual devices, and connected users. It provides continuous operating system and application availability during planned outages for repair of hardware and firmware faults. The Power System E950 server (and other servers using POWER9 technology processors with firmware level FW920 or above) supports secure LPM, whereby the VM image is encrypted and compressed prior to transfer. Secure LPM uses on-chip encryption and compression capabilities of the POWER9 processor for optimal performance.
Service processor
Diagnostic monitoring of recoverable error from the processor chipset is performed on the system processor itself, while the fatal diagnostic monitoring of the processor chipset is performed by the service processor.
Under PowerVM , the service processor supports surveillance of the connection to the HMC and to the system firmware (hypervisor). It also provides several remote power control options, environmental monitoring, reset, restart, remote maintenance, and diagnostic functions, including console mirroring. The service processors menus (ASMI) can be accessed concurrently with system operation, allowing nondisruptive abilities to change system default parameters.
Call home
Call home refers to an automatic or manual call from a client location to the IBM support structure with error log data, server status, or other service-related information. Call home invokes the service organization in order for the appropriate service action to begin. Call home can be done through HMC or most non-HMC-managed systems through Electronic Service Agent running on top of the operating system. While configuring call home is optional, clients are encouraged to implement this feature in order to obtain service enhancements such as reduced problem determination and faster and potentially more accurate transmittal of error information. In general, using the call home feature can result in increased system availability. The Electronic Service Agent application can be configured for automated call home. See the next section for specific details on this application.
IBM Electronic Services
Electronic Service Agent and the IBM Electronic Services web portal comprise the IBM Electronic Services solution, which is dedicated to providing fast, exceptional support to IBM clients. IBM Electronic Service Agent is a no-charge tool that proactively monitors and reports hardware events such as system errors, performance issues, and inventory. Electronic Service Agent can help focus on the client's company business initiatives, save time, and spend less effort managing day-to-day IT maintenance issues.
System configuration and inventory information collected by Electronic Service Agent also can be viewed on the secure Electronic Services web portal and used to improve problem determination and resolution between the client and the IBM support team. As part of an increased focus to provide even better service to IBM clients, Electronic Service Agent tool configuration and activation comes standard with the system. In support of this effort, a new HMC External Connectivity security whitepaper has been published, which describes data exchanges between the HMC and the IBM Service Delivery Center (SDC) and the methods and protocols for this exchange. To read the whitepaper and prepare for Electronic Service Agent installation, see the "Security" section at the IBM Electronic Service Agent website.
Select your country. Click " IBM Electronic Service Agent Connectivity Guide."
Benefits: increased uptime
Electronic Service Agent is designed to enhance the warranty and maintenance service by potentially providing faster hardware error reporting and uploading system information to IBM Support. This can optimize the time monitoring the symptoms, diagnosing the error, and manually calling IBM Support to open a problem record. And 24x7 monitoring and reporting means no more dependency on human intervention or off-hours client personnel when errors are encountered in the middle of the night.
Security: The Electronic Service Agent tool is designed to help secure the monitoring, reporting, and storing of the data at IBM . The Electronic Service Agent tool is designed to help securely transmit either through the internet (HTTPS or VPN) or modem to provide clients a single point of exit from their site. Communication is one way. Activating Electronic Service Agent does not enable IBM to call into a client's system.
For additional information, see the IBM Electronic Service Agent website.
More accurate reporting
Because system information and error logs are automatically uploaded to the IBM Support Center in conjunction with the service request, clients are not required to find and send system information, decreasing the risk of misreported or misdiagnosed errors. Once inside IBM , problem error data is run through a data knowledge management system, and knowledge articles are appended to the problem record.
Customized support
By using the IBMid entered during activation, clients can view system and support information in the "My Systems" and "Premium Search" sections of the Electronic Services website.
The Electronic Services web portal is a single internet entry point that replaces the multiple entry points traditionally used to access IBM internet services and support. This web portal enables you to gain easier access to IBM resources for assistance in resolving technical problems. The newly improved My Systems and Premium Search functions make it even easier for Electronic Service Agent -enabled clients to track system inventory and find pertinent fixes.
My Systems provides valuable reports of installed hardware and software using information collected from the systems by IBM Electronic Service Agent . Reports are available for any system associated with the client's IBMid. Premium Search combines the function of search and the value of Electronic Service Agent information, providing advanced search of the technical support knowledgebase. Using Premium Search and the Service Agent information that has been collected from the system, clients are able to see search results that apply specifically to their systems.
For more information on how to utilize the power of IBM Electronic Services, see the following website or contact an IBM Systems Services Representative .
IBM Proactive Support for Power Systems
Clients have found significant value in IBM's Proactive Support offerings on mission-critical systems, as this provides personalized support, proactive recommendations, and accelerated response times versus standard support. As a result, IBM is including the IBM Proactive Support in the default configuration for all Mid-Range and Enterprise IBM POWER9 Systems - for IBM AIX, IBM i, Linux, and SAP HANA workloads. Other configurations are also available.
Section 508 of the US Rehabilitation Act
IBM Power System E950 (9040-MR9) is capable as of August 17, 2018, when used in accordance with IBM 's associated documentation, of satisfying the applicable requirements of Section 508 of the Rehabilitation Act, provided that any assistive technology used with the product properly interoperates with it. A US Section 508 Accessibility Conformance Statement can be requested on the Product accessibility information website.
Statement of general direction
IBM Power System E950 (9040-MR9) for SAP HANA Production Use
IBM intends to support SAP HANA on the IBM Power System E950 (9040-MR9) in production mode, with the following Linux operating systems, following near-term certification of the environment.
- Red Hat Enterprise Linux for SAP with Red Hat Enterprise Linux 7 for Power LE version 7.5, or later
- SUSE Linux Enterprise Server for SAP with SUSE Linux Enterprise Server 11 Service Pack 4, or later
- SUSE Linux Enterprise Server for SAP with SUSE Linux Enterprise Server 12 Service Pack 3, or later
Statements by IBM regarding its plans, directions, and intent are subject to change or withdrawal without notice at the sole discretion of IBM . Information regarding potential future products is intended to outline general product direction and should not be relied on in making a purchasing decision. The information mentioned regarding potential future products is not a commitment, promise, or legal obligation to deliver any material, code, or functionality. Information about potential future products may not be incorporated into any contract. The development, release, and timing of any future features or functionality described for IBM products remain at the sole discretion of IBM .
Product number
The following are newly announced features on the specific models of the IBM Power Systems 9040 machine type:
Machine Feature Description type Model number
IBM Power System E950 9040 MR9
One CSC Billing Unit 9040 MR9 0010 Ten CSC Billing Units 9040 MR9 0011
AIX Partition Specify 9040 MR9 0265 Linux Partition Specify 9040 MR9 0266 V.24/EIA232 6.1m (20-Ft) PCI Cable 9040 MR9 0348 V.35 6.1m (20-Ft) PCI Cable 9040 MR9 0353 X.21 6.1m (20-Ft) PCI Cable 9040 MR9 0359
UPS Factory Integration Specify 9040 MR9 0373 HMC Factory Integration Specify 9040 MR9 0374 Display Factory Integration Specify 9040 MR9 0375 Reserve Rack Space for UPS 9040 MR9 0376 Reserve Rack Space for HMC 9040 MR9 0377 Reserve Rack Space for Display 9040 MR9 0378 Customer Specified Placement 9040 MR9 0456 19 inch, 1.8 meter high rack 9040 MR9 0551 19 inch, 2.0 meter high rack 9040 MR9 0553 Rack Filler Panel Kit 9040 MR9 0599 Load Source Not in CEC 9040 MR9 0719 SAN Load Source Specify 9040 MR9 0837
US TAA Compliance Indicator 9040 MR9 0983 Product assembled in USA manufacturing plant 9040 MR9 0984
Modem Cable - US/Canada and General Use 9040 MR9 1025 USB 500 GB Removable Disk Drive 9040 MR9 1107 3m, Blue Cat5e Cable 9040 MR9 1111 10m, Blue Cat5e Cable 9040 MR9 1112 25m, Blue Cat5e Cable 9040 MR9 1113 Custom Service Specify, Rochester Minn, USA 9040 MR9 1140 Quantity 150 of #1964 9040 MR9 1818 Quantity 150 of #1953 9040 MR9 1929 300GB 15k RPM SAS SFF-2 Disk Drive (AIX/Linux) 9040 MR9 1953 600GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux) 9040 MR9 1964 Primary OS - AIX 9040 MR9 2146 Primary OS - Linux 9040 MR9 2147 2M LC-SC 50 Micron Fiber Converter Cable 9040 MR9 2456 2M LC-SC 62.5 Micron Fiber Converter Cable 9040 MR9 2459 3M Asynchronous Terminal/Printer Cable EIA-232 9040 MR9 2934 Asynchronous Cable EIA-232/V.24 3M 9040 MR9 2936 Serial-to-Serial Port Cable for Drawer/Drawer- 3.7M 9040 MR9 3124 Serial-to-Serial Port Cable for Rack/Rack- 8M 9040 MR9 3125 Widescreen LCD Monitor 9040 MR9 3632 0.3M Serial Port Converter Cable, 9-Pin to 25-Pin 9040 MR9 3925 Serial Port Null Modem Cable, 9-pin to 9-pin, 3.7M 9040 MR9 3927 Serial Port Null Modem Cable, 9-pin to 9-pin, 10M 9040 MR9 3928 System Serial Port Converter Cable 9040 MR9 3930 1.8 M (6-ft) Extender Cable for Displays (15-pin D-shell to 15-pin D-shell) 9040 MR9 4242 Extender Cable - USB Keyboards, 1.8M 9040 MR9 4256 VGA to DVI Connection Converter 9040 MR9 4276 Power Cord To PDU/UPS, (100-240V/16A) 9040 MR9 4558 Rack Integration Services: BP only 9040 MR9 4648 Rack Integration Services 9040 MR9 4649 Rack Indicator- Not Factory Integrated 9040 MR9 4650 Software Preload Required 9040 MR9 5000 PCIe2 8Gb 4-port Fibre Channel Adapter 9040 MR9 5729 8 Gigabit PCI Express Dual Port Fibre Channel Adapter 9040 MR9 5735 PCIe2 4-port 1GbE Adapter 9040 MR9 5899 Opt Front Door for 1.8m Rack 9040 MR9 6068 Opt Front Door for 2.0m Rack 9040 MR9 6069 1.8m Rack Acoustic Doors 9040 MR9 6248 2.0m Rack Acoustic Doors 9040 MR9 6249 1.8m Rack Trim Kit 9040 MR9 6263 2.0m Rack Trim Kit 9040 MR9 6272 Power Cord 4.3m (14-ft), Drawer to IBM PDU (250V/ 10A) 9040 MR9 6458 Power Cord 4.3m (14-ft), Drawer To OEM PDU (125V, 15A) 9040 MR9 6460 Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (250V/15A) U. S. 9040 MR9 6469 Power Cord 1.8m (6-ft), Drawer to Wall (125V/15A) 9040 MR9 6470 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A) 9040 MR9 6471 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/16A) 9040 MR9 6472 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A) 9040 MR9 6473 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/13A) 9040 MR9 6474 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A) 9040 MR9 6475 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A) 9040 MR9 6476 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A) 9040 MR9 6477 Power Cord 2.7 M(9-foot), To Wall/OEM PDU, (250V, 16A) 9040 MR9 6478 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (125V/15A or 250V/10A ) 9040 MR9 6488 4.3m (14-Ft) 3PH/24A 380-415V Power Cord 9040 MR9 6489 4.3m (14-Ft) 1PH/63A 200-240V Power Cord 9040 MR9 6491 4.3m (14-Ft) 1PH/48-60A 200-240V Power Cord 9040 MR9 6492 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A) 9040 MR9 6493 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A) 9040 MR9 6494 Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 10A) 9040 MR9 6496 Power Cable - Drawer to IBM PDU, 200-240V/10A 9040 MR9 6577 Optional Rack Security Kit 9040 MR9 6580 Power Cord 2.7M (9-foot), To Wall/OEM PDU, (125V, 15A) 9040 MR9 6651 4.3m (14-Ft) 3PH/16A 380-415V Power Cord 9040 MR9 6653 4.3m (14-Ft) 1PH/24-30A Pwr Cord 9040 MR9 6654 4.3m (14-Ft) 1PH/24-30A WR Pwr Cord 9040 MR9 6655 4.3m (14-Ft) 1PH/24A Power Cord 9040 MR9 6656 4.3m (14-Ft) 1PH/32A Power Cord 9040 MR9 6657 4.3m (14-Ft) 1PH/24A Pwr Cd-Korea 9040 MR9 6658 Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 15A) 9040 MR9 6659 Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (125V/15A) 9040 MR9 6660 Power Cord 2.8m (9.2-ft), Drawer to IBM PDU, (250V/10A) 9040 MR9 6665 4.3m (14-Ft) 3PH/32A 380-415V Power Cord-Australia 9040 MR9 6667 Power Cord 4.3M (14-foot), Drawer to OEM PDU, (250V, 15A) 9040 MR9 6669 Power Cord 2.7M (9-foot), Drawer to IBM PDU, 250V/10A 9040 MR9 6671 Power Cord 2M (6.5-foot), Drawer to IBM PDU, 250V/10A 9040 MR9 6672 Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A) 9040 MR9 6680 Environmental Monitoring Probe 9040 MR9 7118 OEM (Generic) Indicator 9040 MR9 7770 OEM (GROUPE BULL) Indicator 9040 MR9 7773 OEM (Hitachi) Indicator 9040 MR9 7775 OEM Publications for IBM Logo Product 9040 MR9 7779 Indicator for Inspur Power servers 9040 MR9 777A Ethernet Cable, 15m, Hardware Management Console to System Unit 9040 MR9 7802 Linux Software Preinstall 9040 MR9 8143 Linux Software Preinstall (Business Partners) 9040 MR9 8144 USB Mouse 9040 MR9 8845 Order Routing Indicator- System Plant 9040 MR9 9169 Language Group Specify - US English 9040 MR9 9300 New AIX License Core Counter 9040 MR9 9440 New Red Hat License Core Counter 9040 MR9 9442 New SUSE License Core Counter 9040 MR9 9443 Other AIX License Core Counter 9040 MR9 9444 Other Linux License Core Counter 9040 MR9 9445 3rd Party Linux License Core Counter 9040 MR9 9446 VIOS Core Counter 9040 MR9 9447 Other License Core Counter 9040 MR9 9449 Ubuntu Linux License Core Counter 9040 MR9 9450 Month Indicator 9040 MR9 9461 Day Indicator 9040 MR9 9462 Hour Indicator 9040 MR9 9463 Minute Indicator 9040 MR9 9464 Qty Indicator 9040 MR9 9465 Countable Member Indicator 9040 MR9 9466 Language Group Specify - Dutch 9040 MR9 9700 Language Group Specify - French 9040 MR9 9703 Language Group Specify - German 9040 MR9 9704 Language Group Specify - Polish 9040 MR9 9705 Language Group Specify - Norwegian 9040 MR9 9706 Language Group Specify - Portuguese 9040 MR9 9707 Language Group Specify - Spanish 9040 MR9 9708 Language Group Specify - Italian 9040 MR9 9711 Language Group Specify - Canadian French 9040 MR9 9712 Language Group Specify - Japanese 9040 MR9 9714 Language Group Specify - Traditional Chinese (Taiwan) 9040 MR9 9715 Language Group Specify - Korean 9040 MR9 9716 Language Group Specify - Turkish 9040 MR9 9718 Language Group Specify - Hungarian 9040 MR9 9719 Language Group Specify - Slovakian 9040 MR9 9720 Language Group Specify - Russian 9040 MR9 9721 Language Group Specify - Simplified Chinese (PRC) 9040 MR9 9722 Language Group Specify - Czech 9040 MR9 9724 Language Group Specify - Romanian 9040 MR9 9725 Language Group Specify - Croatian 9040 MR9 9726 Language Group Specify - Slovenian 9040 MR9 9727 Language Group Specify - Brazilian Portuguese 9040 MR9 9728 Language Group Specify - Thai 9040 MR9 9729 QSFP+ 40GbE Base-SR Transceiver 9040 MR9 EB27 1m (3.3-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC) 9040 MR9 EB2B 3m (9.8-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC) 9040 MR9 EB2H 10m (30.3-ft), IBM Passive QSFP+ MTP Optical Cable 9040 MR9 EB2J 30m (90.3-ft), IBM Passive QSFP+ MTP Optical Cable 9040 MR9 EB2K Lift Tool 9040 MR9 EB2Z Power Supply - 2000W for Server (200-240 VAC) 9040 MR9 EB3M Lift tool based on GenieLift GL-8 (standard) 9040 MR9 EB3Z 10GbE Optical Transceiver SFP+ SR 9040 MR9 EB46 25GbE Optical Transceiver SFP28 9040 MR9 EB47 0.5m SFP28/25GbE copper Cable 9040 MR9 EB4J 1.0m SFP28/25GbE copper Cable 9040 MR9 EB4K 1.5m SFP28/25GbE copper Cable 9040 MR9 EB4L 2.0m SFP28/25GbE copper Cable 9040 MR9 EB4M 2.0m QSFP28/100GbE copper split Cable to SFP28 4x25GbE 9040 MR9 EB4P Service wedge shelf tool kit for EB3Z 9040 MR9 EB4Z 0.5m EDR IB Copper Cable QSFP28 9040 MR9 EB50 1.0m EDR IB Copper Cable QSFP28 9040 MR9 EB51 2.0M EDR IB Copper Cable QSFP28 9040 MR9 EB52 1.5M EDR IB Copper Cable QSFP28 9040 MR9 EB54 100GbE Optical Transceiver QSFP28 9040 MR9 EB59 3M EDR IB Optical Cable QSFP28 9040 MR9 EB5A 5M EDR IB Optical Cable QSFP28 9040 MR9 EB5B 10M EDR IB Optical Cable QSFP28 9040 MR9 EB5C 15M EDR IB Optical Cable QSFP28 9040 MR9 EB5D 20M EDR IB Optical Cable QSFP28 9040 MR9 EB5E 30M EDR IB Optical Cable QSFP28 9040 MR9 EB5F 50M EDR IB Optical Cable QSFP28 9040 MR9 EB5G 100M EDR IB Optical Cable QSFP28 9040 MR9 EB5H 0.5M 100GbE Copper Cable QSFP28 9040 MR9 EB5J 1.0M 100GbE Copper Cable QSFP28 9040 MR9 EB5K 1.5M 100GbE Copper Cable QSFP28 9040 MR9 EB5L 2.0M 100GbE Copper Cable QSFP28 9040 MR9 EB5M 3M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5R 5M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5S 10M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5T 15M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5U 20M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5V 30M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5W 50M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5X 100M 100GbE Optical Cable QSFP28 (AOC) 9040 MR9 EB5Y Rack Front Door (Black) 9040 MR9 EC01 Rack Rear Door 9040 MR9 EC02 Rack Side Cover 9040 MR9 EC03 Rack Suite Attachment Kit 9040 MR9 EC04 Slim Rear Acoustic Door 9040 MR9 EC07 Slim Front Acoustic Door 9040 MR9 EC08 Rear Door Heat Exchanger for 2.0 Meter Slim Rack 9040 MR9 EC15 PCIe3 2-Port 10Gb NIC&ROCE SR/Cu Adapter 9040 MR9 EC2S PCIe3 2-Port 25/10Gb NIC&ROCE SR/Cu Adapter 9040 MR9 EC2U Mainstream 800 GB SSD NVMe U.2 module 9040 MR9 EC5J Mainstream 1.6 TB SSD NVMe U.2 module 9040 MR9 EC5K Mainstream 3.2 TB SSD NVMe U.2 module 9040 MR9 EC5L PCIe4 2-port 100Gb ROCE EN adapter 9040 MR9 EC66 0.6m (2.0-ft), Blue CAT5 Ethernet Cable 9040 MR9 ECB0 1.5m (4.9-ft), Blue CAT5 Ethernet Cable 9040 MR9 ECB2 SAS X Cable 3m - HD Narrow 6Gb 2-Adapters to Enclosure 9040 MR9 ECBJ SAS X Cable 6m - HD Narrow 6Gb 2-Adapters to Enclosure 9040 MR9 ECBK SAS X Cable 10m - HD Narrow 6Gb 2-Adapters to Enclosure 9040 MR9 ECBL SAS X Cable 15m - HD Narrow 3Gb 2-Adapters to Enclosure 9040 MR9 ECBM SAS YO Cable 1.5m - HD Narrow 6Gb Adapter to Enclosure 9040 MR9 ECBT SAS YO Cable 3m - HD Narrow 6Gb Adapter to Enclosure 9040 MR9 ECBU SAS YO Cable 6m - HD Narrow 6Gb Adapter to Enclosure 9040 MR9 ECBV SAS YO Cable 10m - HD Narrow 6Gb Adapter to Enclosure 9040 MR9 ECBW SAS YO Cable 15m - HD Narrow 3Gb Adapter to Enclosure 9040 MR9 ECBX SAS AE1 Cable 4m - HD Narrow 6Gb Adapter to Enclosure 9040 MR9 ECBY SAS YE1 Cable 3m - HD Narrow 6Gb Adapter to Enclosure 9040 MR9 ECBZ SAS AA Cable 0.6m - HD Narrow 6Gb Adapter to Adapter 9040 MR9 ECC0 SAS AA Cable 1.5m - HD Narrow 6Gb Adapter to Adapter 9040 MR9 ECC2 SAS AA Cable 3m - HD Narrow 6Gb Adapter to Adapter 9040 MR9 ECC3 SAS AA Cable 6m - HD Narrow 6Gb Adapter to Adapter 9040 MR9 ECC4 3M Optical Cable Pair for PCIe3 Expansion Drawer 9040 MR9 ECC7 10M Optical Cable Pair for PCIe3 Expansion Drawer 9040 MR9 ECC8 System Port Converter Cable for UPS 9040 MR9 ECCF 3M Copper CXP Cable Pair for PCIe3 Expansion Drawer 9040 MR9 ECCS 3.0M SAS X12 Cable (Two Adapter to Enclosure) 9040 MR9 ECDJ 4.5M SAS X12 Active Optical Cable (Two Adapter to Enclosure) 9040 MR9 ECDK 10M SAS X12 Active Optical Cable (Two Adapter to Enclosure) 9040 MR9 ECDL 1.5M SAS YO12 Cable (Adapter to Enclosure) 9040 MR9 ECDT 3.0M SAS YO12 Cable (Adapter to Enclosure) 9040 MR9 ECDU 4.5M SAS YO12 Active Optical Cable (Adapter to Enclosure) 9040 MR9 ECDV 10M SAS YO12 Active Optical Cable (Adapter to Enclosure) 9040 MR9 ECDW 0.6M SAS AA12 Cable (Adapter to Adapter) 9040 MR9 ECE0 3.0M SAS AA12 Cable 9040 MR9 ECE3 4.5M SAS AA12 Active Optical Cable (Adapter to Adapter) 9040 MR9 ECE4 Cloud Private Solution 9040 MR9 ECP0 2.0 Meter Slim Rack 9040 MR9 ECR0 Rack Front Door High-End appearance 9040 MR9 ECRF Rack Rear Door Black 9040 MR9 ECRG Rack Side Cover 9040 MR9 ECRJ Rack Rear Extension 5-In 9040 MR9 ECRK Rack Front Door for Rack (Black/Flat) 9040 MR9 ECRM Custom Service Specify, Montpellier, France 9040 MR9 ECSF NeuCloud Indicator/Specify 9040 MR9 ECSJ Custom Service Specify, Mexico 9040 MR9 ECSM Custom Service Specify, Poughkeepsie, USA 9040 MR9 ECSP Optical Wrap Plug 9040 MR9 ECW0
Solution Edition for Healthcare typical 3.15 to 3.8 GHz, 12-core Processor Module 9040 MR9 EHC4
SAP HANA TRACKING FEATURE 9040 MR9 EHKV Boot Drive / Load Source in EXP12SX Specify (in #ESLL or #ELLL) 9040 MR9 EHR1 Boot Drive / Load Source in EXP24SX Specify (in #ESLS or #ELLS) 9040 MR9 EHR2 SSD Placement Indicator - #ESLS/#ELLS 9040 MR9 EHS2 PCIe3 Optical Cable Adapter for PCIe3 Expansion Drawer 9040 MR9 EJ08 Storage Backplane with Zero DASD 8 SAS 2.5" HDD/ SDD Controllers 9040 MR9 EJ0B PCIe3 RAID SAS Adapter Quad-port 6Gb x8 9040 MR9 EJ0J PCIe3 RAID SAS Adapter Quad-port 6Gb x8 for MR9 9040 MR9 EJ0K PCIe3 SAS Tape/DVD Adapter Quad-port 6Gb x8 9040 MR9 EJ10 PCIe3 12GB Cache RAID PLUS SAS Adapter Quad-port 6Gb x8 9040 MR9 EJ14 PCIe3 Crypto Coprocessor BSC-Gen3 4767 9040 MR9 EJ33 Storage Backplane Base DASD 8 SAS 2.5" HDD/SDD Controllers 9040 MR9 EJBB Non-paired Indicator EJ14 PCIe SAS RAID+ Adapter 9040 MR9 EJRL Storage Backplane Split DASD 8 SAS 2.5" HDD/SDD Controllers 9040 MR9 EJSB Specify Mode-1 & (1)EJ0J/EJ0M/EL3B/EL59 & (1)YO12 for EXP12SX #ESLL/ELLL 9040 MR9 EJV1 Specify Mode-1 & (2)EJ0J/EJ0M/EL3B/EL59 & (2)YO12 for EXP12SX #ESLL/ELLL 9040 MR9 EJV2 Specify Mode-2 & (2)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP12SX #ESLL/ELLL 9040 MR9 EJV3 Specify Mode-2 & (4)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP12SX #ESLL/ELLL 9040 MR9 EJV4 Specify Mode-4 & (4)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP12SX #ESLL/ELLL 9040 MR9 EJV5 Specify Mode-2 & (1)EJ0J/EJ0M/EL3B/EL59 & (2)YO12 for EXP12SX #ESLL/ELLL 9040 MR9 EJV6 Specify Mode-2 & (2)EJ0J/EJ0M/EL3B/EL59 & (2)YO12 for EXP12SX #ESLL/ELLL 9040 MR9 EJV7 Specify Mode-2 & (1)EJ0J/EJ0M/EL3B/EL59 & (1)YO12 for EXP12SX #ESLL/ELLL 9040 MR9 EJVA Specify Mode-2 & (2)EJ0J/EJ0M/EL3B/EL59 & (1)X12 for EXP12SX #ESLL/ELLL 9040 MR9 EJVB Specify Mode-4 & (1)EJ0J/EJ0M/EL3B/EL59 & (1)X12 for EXP12SX #ESLL/ELLL 9040 MR9 EJVC Specify Mode-4 & (2)EJ0J/EJ0M/EL3B/EL59 & (1)X12 for EXP12SX #ESLL/ELLL 9040 MR9 EJVD Specify Mode-4 & (3)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP12SX #ESLL/ELLL 9040 MR9 EJVE Specify Mode-1 & (2)EJ14 & (2)YO12 for EXP12SX #ESLL/ELLL 9040 MR9 EJVF Specify Mode-2 & (1)EJ0K & (2)YO12 for EXP12SX #ESLL/ELLL 9040 MR9 EJVW Specify Mode-1 & (1)EJ0J/EJ0M/EL3B/EL59 & (1)YO12 for EXP24SX #ESLS/ELLS 9040 MR9 EJW1 Specify Mode-1 & (2)EJ0J/EJ0M/EL3B/EL59 & (2)YO12 for EXP24SX #ESLS/ELLS 9040 MR9 EJW2 Specify Mode-2 & (2)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJW3 Specify Mode-2 & (4)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJW4 Specify Mode-4 & (4)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJW5 Specify Mode-2 & (1)EJ0J/EJ0M/EL3B/EL59 & (2)YO12 for EXP24SX #ESLS/ELLS 9040 MR9 EJW6 Specify Mode-2 & (2)EJ0J/EJ0M/EL3B/EL59 & (2)YO12 for EXP24SX #ESLS/ELLS 9040 MR9 EJW7 Specify Mode-2 & (1)EJ0J/EJ0M/EL3B/EL59 & (1)YO12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWA Specify Mode-2 & (2)EJ0J/EJ0M/EL3B/EL59 & (1)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWB Specify Mode-4 & (1)EJ0J/EJ0M/EL3B/EL59 & (1)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWC Specify Mode-4 & (2)EJ0J/EJ0M/EL3B/EL59 & (1)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWD Specify Mode-4 & (3)EJ0J/EJ0M/EL3B/EL59 & (2)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWE Specify Mode-1 & (2)EJ14 & (2)YO12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWF Specify Mode-2 & (2)EJ14 & (2)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWG Specify Mode-2 & (2)EJ14 & (1)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWH Specify Mode-2 & (4)EJ14 & (2)X12 for EXP24SX #ESLS/ELLS 9040 MR9 EJWJ Specify Mode-1 & (2)EJ0k & (2)YO12G for EXP24SX #ESLS/ELLS 9040 MR9 EJWW
Base Processor Activation (12) for Healthcare Solution (#EHC4) 9040 MR9 ELAN
1-core Linux Processor Activation for #EPWR 9040 MR9 ELBG 1-core Linux Processor Activation for #EPWT 9040 MR9 ELBH PowerVM for Linux indicator 9040 MR9 ELBJ 1-core Linux Processor Activation for #EPWS 9040 MR9 ELBP 1-core Linux Processor Activation for #EPWY 9040 MR9 ELBR PDU Access Cord 0.38m 9040 MR9 ELC0 Power Cable - Drawer to IBM PDU (250V/10A) 9040 MR9 ELC5 Power IFL Memory Activation 9040 MR9 ELNP Memory Riser Card 9040 MR9 EM03 8 GB DDR4 Memory 9040 MR9 EM6A 16 GB DDR4 Memory 9040 MR9 EM6B 32 GB DDR4 Memory 9040 MR9 EM6C 64 GB DDR4 Memory 9040 MR9 EM6D 128 GB DDR4 Memory 9040 MR9 EM6E Active Memory Mirroring 9040 MR9 EM81 90 Days Elastic CoD Memory Enablement 9040 MR9 EM9U Power Active Memory Expansion 9040 MR9 EMAM
128 GB Base Memory activation for MR9 #EHC4 9040 MR9 EMAN
1GB Memory Activation 9040 MR9 EMAP Quantity of 100 1GB Memory Activations 9040 MR9 EMAQ 512 GB Linux Memory Activations for MR9 9040 MR9 EMBE VRM DDR4 Memory for MR9 9040 MR9 EMEF 8 GB-Day Billing for Elastic CoD Memory 9040 MR9 EMJE 800 GB-Day Billing for Elastic CoD Memory 9040 MR9 EMJF PCIe Gen3 I/O Expansion Drawer 9040 MR9 EMX0 AC Power Supply Conduit for PCIe3 Expansion Drawer 9040 MR9 EMXA PCIe3 6-Slot Fanout Module for PCIe3 Expansion Drawer 9040 MR9 EMXF PCIe3 6-Slot Fanout Module for PCIe3 Expansion Drawer 9040 MR9 EMXG 1m (3.3-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper 9040 MR9 EN01 3m (9.8-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper 9040 MR9 EN02 5m (16.4-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper 9040 MR9 EN03 PCIe3 16Gb 2-port Fibre Channel Adapter 9040 MR9 EN0A PCIe3 4-port (10Gb FCoE & 1GbE) SR&RJ45 9040 MR9 EN0H PCIe3 4-port (10Gb FCoE & 1GbE) SFP+Copper&RJ45 9040 MR9 EN0K PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter 9040 MR9 EN0S PCIe2 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter 9040 MR9 EN0U PCIe2 2-port 10/1GbE BaseT RJ45 Adapter 9040 MR9 EN0W PCIe2 8Gb 4-port Fibre Channel Adapter 9040 MR9 EN12 PCIe3 4-port 10GbE SR Adapter 9040 MR9 EN15 PCIe3 32Gb 2-port Fibre Channel Adapter 9040 MR9 EN1A PCIe3 16Gb 4-port Fibre Channel Adapter 9040 MR9 EN1C 90 Days Elastic CoD Processor Core Enablement 9040 MR9 EP9T 1 Proc-day Elastic billing for #EPWR/EPWK 9040 MR9 EPN0 100 Proc-day Elastic COD billing #EPWR/EPWK AIX 9040 MR9 EPN1 100 Proc-mins Utility COD billing #EPWR/EPWK 9040 MR9 EPN2 1-core Processor Activation for #EPWY 9040 MR9 EPN3 1 Proc-day Elastic billing for #EPWS/EPWL 9040 MR9 EPN5 100 Proc-day Elastic COD billing #EPWS/EPWL AIX 9040 MR9 EPN6 100 Proc-mins Utility COD billing #EPWS/EPWL 9040 MR9 EPN7 1 Proc-day Elastic billing for #EPWY/EPWZ 9040 MR9 EPN8 100 Proc-day Elastic COD billing #EPWY/EPWZ AIX 9040 MR9 EPN9 1 Proc-day Elastic billing for #EPWT/EPWM 9040 MR9 EPNK 100 Proc-day Elastic COD billing #EPWT/EPWM AIX 9040 MR9 EPNL 100 Proc-mins Utility COD billing #EPWT/EPWM 9040 MR9 EPNM 100 Proc-mins Utility COD billing #EPWY/EPWZ 9040 MR9 EPNN Horizontal PDU Mounting Hardware 9040 MR9 EPTH High Function 9xC19 PDU: Switched, Monitoring 9040 MR9 EPTJ High Function 9xC19 PDU 3-Phase: Switched, Monitoring 9040 MR9 EPTL High Function 12xC13 PDU: Switched, Monitoring 9040 MR9 EPTN High Function 12xC13 PDU 3-Phase: Switched, Monitoring 9040 MR9 EPTQ PowerVM - Enterprise Edition 9040 MR9 EPVV 8-core Typical 3.6 to 3.8 GHZ (max) processor 9040 MR9 EPWR 10-core Typical 3.4 to 3.8 GHZ (max) processor 9040 MR9 EPWS 12-core Typical 3.15 to 3.8 GHZ (max) processor 9040 MR9 EPWT 1-core Processor Activation for #EPWR 9040 MR9 EPWV 1-core Processor Activation for #EPWS 9040 MR9 EPWW 1W Processor activation for #EPWT 9040 MR9 EPWX 11-core Typical 3.2 to 3.8 GHZ (max) processor 9040 MR9 EPWY Quantity 150 of #ES62 3.86-4.0 TB 7200 rpm 4k LFF-1 Disk 9040 MR9 EQ62 Quantity 150 of #ES64 7.72-8.0 TB 7200 rpm 4k LFF-1 Disk 9040 MR9 EQ64 Qty 150 of #6577 9040 MR9 EQ77 Quantity 150 of #ES78 387GB SFF-2 SSD 5xx 9040 MR9 EQ78 Quantity 150 of #ES7E 775GB SFF-2 SSD 5xx 9040 MR9 EQ7E Quantity 150 of #ES80 1.9TB SFF-2 SSD 4k 9040 MR9 EQ80 Quantity 150 of #ES85 387GB SFF-2 SSD 4k 9040 MR9 EQ85 Quantity 150 of #ES8C 775GB SFF-2 SSD 4k 9040 MR9 EQ8C Quantity 150 of #ES8F 1.55TB SFF-2 SSD 4k 9040 MR9 EQ8F Quantity 150 of #ES8Y 931GB SFF-2 SSD 4k 9040 MR9 EQ8Y Quantity 150 of ES96 1.86TB SFF-2 SSD 4k 9040 MR9 EQ96 Quantity 150 of #ESE7 3.72TB SFF-2 SSD 4k 9040 MR9 EQE7 Quantity 150 of #ESEV (600GB 10k SFF-2) 9040 MR9 EQEV Quantity 150 of #ESEZ (300GB SFF-2) 9040 MR9 EQEZ Quantity 150 of #ESF3 (1.2TB 10k SFF-2) 9040 MR9 EQF3 Quantity 150 of #ESFP (600GB SFF-2) 9040 MR9 EQFP Quantity 150 of #ESFT (1.8TB 10k SFF-2) 9040 MR9 EQFT Quantity 150 of #ESG5 (387GB SAS 5xx) 9040 MR9 EQG5 Quantity 150 of #ESGB (387GB SAS 4k) 9040 MR9 EQGB Quantity 150 of #ESGF (775GB SAS 5xx) 9040 MR9 EQGF Quantity 150 of #ESGK (775GB SAS 4k) 9040 MR9 EQGK Quantity 150 of #ESGP (1.55TB SAS 4k) 9040 MR9 EQGP 42U Slim Rack 9040 MR9 ER05 RFID Tags for Servers, Compute Nodes, Chassis, Racks, and HMCs 9040 MR9 ERF1 Rear rack extension 9040 MR9 ERG0 Optional Origami Front Door for 2.0m Rack 9040 MR9 ERG7 Quantity 150 of #ESHJ 931 GB SSD 4k SFF-2 9040 MR9 ERHJ Quantity 150 of #ESHL 1.86 TB SSD 4k SFF-2 9040 MR9 ERHL Quantity 150 of #ESHN 7.45 TB SSD 4k SFF-2 9040 MR9 ERHN Quantity 150 of #ESM8 3.72 TB SSD 4k SFF-2 9040 MR9 ERM8 3.86-4.0 TB 7200 RPM 4K SAS LFF-1 Nearline Disk Drive (AIX/Linux) 9040 MR9 ES62 7.72-8.0 TB 7200 RPM 4K SAS LFF-1 Nearline Disk Drive (AIX/Linux) 9040 MR9 ES64 387GB SFF-2 SSD 5xx eMLC4 for AIX/Linux 9040 MR9 ES78 775GB SFF-2 SSD 5xx eMLC4 for AIX/Linux 9040 MR9 ES7E 387GB SFF-3 SSD 5xx eMLC4 for AIX/Linux 9040 MR9 ES7K 775GB SFF-3 SSD 5xx eMLC4 for AIX/Linux 9040 MR9 ES7P 1.9TB Read Intensive SAS 4k SFF-2 SSD for AIX/ Linux 9040 MR9 ES80 931GB Mainstream SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ES83 387GB SFF-2 SSD 4k eMLC4 for AIX/Linux 9040 MR9 ES85 775GB SFF-2 SSD 4k eMLC4 for AIX/Linux 9040 MR9 ES8C 1.55TB SFF-2 SSD 4k eMLC4 for AIX/Linux 9040 MR9 ES8F 1.9TB Read Intensive SAS 4k SFF-3 SSD for AIX/ Linux 9040 MR9 ES8J 387GB SFF-3 SSD 4k eMLC4 for AIX/Linux 9040 MR9 ES8N 775GB SFF-3 SSD 4k eMLC4 for AIX/Linux 9040 MR9 ES8Q 1.55TB SFF-3 SSD 4k eMLC4 for AIX/Linux 9040 MR9 ES8V 931GB Mainstream SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ES8Y 1.86TB Mainstream SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ES92 1.86TB Mainstream SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ES96 S&H - No Charge 9040 MR9 ESC0 S&H 9040 MR9 ESC7 600GB 10K RPM SAS SFF-3 Disk Drive (AIX/Linux) 9040 MR9 ESD5 300GB 15K RPM SAS SFF-3 Disk Drive (AIX/Linux) 9040 MR9 ESDB 3.72TB Mainstream SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESE1 3.72TB Mainstream SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESE7 600GB 10K RPM SAS SFF-2 Disk Drive 4K Block - 4096 9040 MR9 ESEV 300GB 15K RPM SAS SFF-2 4K Block - 4096 Disk Drive 9040 MR9 ESEZ 1.2TB 10K RPM SAS SFF-2 Disk Drive 4K Block - 4096 9040 MR9 ESF3 600GB 10K RPM SAS SFF-3 Disk Drive 4K Block - 4096 9040 MR9 ESF5 1.2TB 10K RPM SAS SFF-3 Disk Drive 4K Block - 4096 9040 MR9 ESF9 300GB 15K RPM SAS SFF-3 4K Block - 4096 Disk Drive 9040 MR9 ESFB 600GB 15K RPM SAS SFF-3 4K Block - 4096 Disk Drive 9040 MR9 ESFF 600GB 15K RPM SAS SFF-2 4K Block - 4096 Disk Drive 9040 MR9 ESFP 1.8TB 10K RPM SAS SFF-2 Disk Drive 4K Block - 4096 9040 MR9 ESFT 1.8TB 10K RPM SAS SFF-3 Disk Drive 4K Block - 4096 9040 MR9 ESFV 387GB Enterprise SAS 5xx SFF-2 SSD for AIX/Linux 9040 MR9 ESG5 387GB Enterprise SAS 5xx SFF-3 SSD for AIX/Linux 9040 MR9 ESG9 387GB Enterprise SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESGB 387GB Enterprise SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESGD 775GB Enterprise SAS 5xx SFF-2 SSD for AIX/Linux 9040 MR9 ESGF 775GB Enterprise SAS 5xx SFF-3 SSD for AIX/Linux 9040 MR9 ESGH 775GB Enterprise SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESGK 775GB Enterprise SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESGM 1.55TB Enterprise SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESGP 1.55TB Enterprise SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESGR 931 GB Mainstream SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESHJ 1.86 TB Mainstream SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESHL 7.45 TB Mainstream SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESHN 931 GB Mainstream SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESHS 1.86 TB Mainstream SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESHU 7.45 TB Mainstream SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESHW Specify AC Power Supply for EXP12SX/EXP24SX Storage Enclosure 9040 MR9 ESLA EXP12SX SAS Storage Enclosure 9040 MR9 ESLL EXP24SX SAS Storage Enclosure 9040 MR9 ESLS 3.72 TB Mainstream SAS 4k SFF-2 SSD for AIX/Linux 9040 MR9 ESM8 3.72 TB Mainstream SAS 4k SFF-3 SSD for AIX/Linux 9040 MR9 ESMQ 300GB 15K RPM SAS SFF-3 4k Block Cached Disk Drive (AIX/Linux) 9040 MR9 ESNK 300GB 15K RPM SAS SFF-2 4k Block Cached Disk Drive (AIX/Linux) 9040 MR9 ESNM 600GB 15K RPM SAS SFF-3 4k Block Cached Disk Drive (AIX/Linux) 9040 MR9 ESNP 600GB 15K RPM SAS SFF-2 4k Block Cached Disk Drive (AIX/Linux) 9040 MR9 ESNR Quantity 150 of #ESNM (300GB 15k SFF-2) 9040 MR9 ESPM Quantity 150 of #ESNR (600GB 15k SFF-2) 9040 MR9 ESPR 1TB Removable Disk Drive Cartridge 9040 MR9 EU01 RDX USB External Docking Station for Removable Disk Cartridge 9040 MR9 EU04 RDX 320 GB Removable Disk Drive 9040 MR9 EU08 1.5TB Removable Disk Drive Cartridge 9040 MR9 EU15
2TB Removable Disk Drive Cartridge (RDX) 9040 MR9 EU2T
RDX USB External Docking Station 9040 MR9 EUA4
Standalone USB DVD drive w/cable 9040 MR9 EUA5 Core Use HW Feature 9040 MR9 EUC6 Core Use HW Feature 10X 9040 MR9 EUC7 5000 Power to Cloud Reward points 9040 MR9 SVPC
The following are newly announced features on the specific models of the IBM Power Systems 7014 and 7965 machine type:
New features available August 17, 2018
Machine Feature Description type Model number
Rack Content Specify 9040-MR9 -4EIA 7014 T42 ERCZ 7965 S42
Pricing terms
Prices in the following PDF prices link are suggested list prices on day of announcement for the U.S. only. They are provided for your information only. Dealer prices may vary, and prices may also vary by country. IBM list price does not include tax or shipping and is subject to change without notice.
Business Partner information
If you are a Direct Reseller - System Reseller acquiring products from IBM , you may link directly to Business Partner information for this announcement. A PartnerWorld® ID and password are required (use IBMid).
Publications
Power Systems hardware documentation provides you with the following topical information:
- Licenses, notices, safety, and warranty information
- Planning for the system
- Installing and configuring the system
- Troubleshooting, service, and support
- Installing, configuring, and managing consoles, terminals, and interfaces
- Installing operating systems
- Creating a virtual computing environment
- Enclosures and expansion units
- Glossary
You can access the POWER9 systems information at IBM Knowledge Center .
Product documentation is also available on DVD (SK5T-7087).
The following information is shipped with the 9040-MR9:
- Power Hardware Information DVD (SK5T-7087)
- Important Notices
- Warranty Information
- License Agreement for Machine Code
Hardware documentation such as installation instructions, user's information, and service information is available to download or view at the IBM Support Portal website.
The IBM Systems Information Center provides you with a single information center where you can access product documentation for IBM systems hardware, operating systems, and server software. Through a consistent framework, you can efficiently find information and personalize your access. Go the IBM Systems Information Center, at IBM Knowledge Center .
To access the IBM Publications Center Portal, go to the IBM Publications Center website.
The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, which can currently be downloaded.
Services
IBM Systems Lab Services
IBM Systems Lab Services offers a wide array of services available for your enterprise. It brings expertise on the latest technologies from the IBM development community and can help with your most difficult technical challenges.
IBM Systems Lab Services exists to help you successfully implement emerging technologies so as to accelerate your return on investment and improve your satisfaction with your IBM systems and solutions. Services examples include initial implementation, integration, migration, and skills transfer on IBM systems solution capabilities and recommended practices. IBM Systems Lab Services is one of the service organizations of IBM 's world-renowned IBM Systems Group development labs.
For details on available services, contact your IBM representative or go to the IBM Systems Lab Services website.
Power to Cloud Reward Program
The IBM Power to Cloud Reward Program is designed to accelerate the transformation of your IT infrastructure to private and hybrid cloud, by helping you design, build and deliver a cloud platform on IBM Power Systems servers with help from IBM Systems Lab Services. You can earn reward points on purchases of select IBM Power Systems servers. Reward points can be used for a range of services focused on helping the transition from traditional IT platforms to private and hybrid cloud platforms by leveraging the proven expertise of IBM Systems Lab Services consultants.
The Power to Cloud Reward option is included with new Power E950 systems and MES upgrades into a Power E950. The Lab Services Power to Cloud team will contact the account team/customer after the shipment to help with the selection of a Power to Cloud service offer. Optionally, the account team or the client may contact the Worldwide Power to Cloud team at pwrcloud@us.ibm.com. The customer has up to 90 days from the installation date of the Power E950 to select a Power to Cloud offering. Delivery of the selected service must be completed within 12 months of the installation date of the Power E950 system.
For more details on available Power to Cloud options, see the IBM Power to Cloud Reward Program website.
Global Technology Services
IBM services include business consulting, outsourcing, hosting services, applications, and other technology management.
These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an on-demand business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non- IBM offerings. IBM is your one-stop shop for IT support needs.
For details on available services, contact your IBM representative or go to the IBM Global Technology Services® website.
For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or go to the Business Resiliency Services website.
Details on education offerings related to specific products can be found on the IBM authorized training website.
Technical information
Specified operating environment
Physical specifications
Power E950 (9040-MR9)
System node
- Width: 448 mm (17.5 in.)
- Depth: 902 mm (35.5 in.)
- Height: 175 mm (6.9 in.), 4 EIA units
- Weight: 69 kg (152 lb)
Note: The EMX0 Remote I/O Drawer connection in the T42 and S42 racks will stop the rear door from closing, thus requiring the mandatory 8 inches rack extensions.
PCIe I/O Expansion Drawer
- Width: 448 mm (17.5 in.)
- Depth: 736.6 mm (29 in.)
- Height: 177.8 mm (7.0 in.), 4 EIA units
- Weight: 54.4 kg (120 lb)
To assure installability and serviceability in non- IBM industry-standard racks, review the installation planning information for any product-specific installation requirements.
Operating environment
-
Temperature:
- 5°C - 45°C (41°F - 113°F) nonoperating
- 18°C - 27°C (64°F - 80°F) recommended operating
- 10°C - 40°C (50°F - 104°F) allowable operating
- Derate maximum allowable dry-bulb temperature 1°C (1.8°F) per 175 m (574 ft) above 900 m (2,953 ft) up to a maximum allowable elevation of 3050 m (10,000 ft).
-
Relative humidity (noncondensing):
- 5% - 80% RH nonoperating
- 8% - 80% operating
-
Maximum dew point:
- 27°C (80°F) nonoperating
- 24°C (75°F) operating
-
Operating voltage: 200 - 240 V AC
- Operating frequency: 50 - 60 Hz +/- 3 Hz
- Power consumption: 3,850 watts maximum (per system node)
- Power source loading: 3.9 kVA maximum (per system node)
- Thermal output: 14,403 Btu/hr maximum (per system node)
-
Maximum altitude: 3,050 m (10,000 ft)
- Notes
:
- To calculate the amperage, multiply the kVA by 1000 and divide that number by the operating voltage.
- Model 9040-MR9 use four power supply units.
- Notes
:
-
Noise level: (Acoustics A-weighted Upper-Limit Sound
Power
Levels)
-
One typically configured four 8-core or 12-core, 2 TB memory:
- 7.4 bels (operating/idle: 25 C, 500 m)
-
One maximum configured four 12-core, 2 TB memory:
- 8.1 bels (heavy workload, 25 C, 500 m)
The Power E950 server must be installed in a rack with a rear door and side panels for EMC compliance. The native HMC Ethernet ports must use shielded Ethernet cables.
Note: Government regulations, such as those prescribed by OSHA or European Community Directives, may govern noise level exposure in the workplace and may apply to you and your server installation. This IBM system is available with an optional acoustical door feature that can help reduce the noise emitted from this system. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room where you designate the racks to be installed; the noise levels from other equipment; the room ambient temperature, and employees' location in relation to the equipment. Further, compliance with such government regulations also depends upon a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. IBM recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.
EMC conformance classification
This equipment is subject to Electromagnetic Compatibility (EMC) regulations and shall comply with the appropriate country EMC regulations before final delivery to the buyer or centers of distribution.
- US: FCC CFR, Title 47, Part 15, EMI Class A
- EEA, Turkey: EU Council Directive 2014/30/EU, EMI Class A
- Japan: VCCI Council, EMI Class A
- Korea: RRA, EMI Class A
- China (PRC): CPCS, EMI Class A
- Taiwan R.O.C.: BSMI CNS 13438, EMI Class A
- Australia\New Zealand: ACMA, EMI Class A
- Canada: ICES-003, EMI Class A
- Eurasian Economic Area (EAEU), EMI Class A
- Saudi Arabia: MoCI, EMI Class A
- Vietnam: MIC, EMI Class A
- Morocco EMC Order, EMC Class A
Homologation - Telecom type approval
Homologation approval for specific countries has been initiated with the IBM Homologation and Type Approval (HT&A) organization in Nice, France.
The Power System E950 server nodes or system control unit or PCIe Expansion units are not certified for connection to interfaces of public telecommunications networks. Certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions and for information on PCIe adapters that can be used in the system and which are certified.
Product safety/country testing/certification
- UL 60950-1:2007 Underwriters Laboratory
- CAN/CSA22.2 No. 60950-1-07
- EN60950-1:2006 European Norm
- IEC 60950-1 2nd Edition + all National Differences
-
One typically configured four 8-core or 12-core, 2 TB memory:
Homologation
The Power System E950 server nodes or system control unit or PCIe Expansion units are not certified for direct connection to interfaces of public telecommunications networks. Certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions and for information on PCIe adapters that can be used in the system and which are certified.
Software requirements
If installing the AIX operating system LPAR with any I/O configuration (one of these):
- AIX Version 7.2 with the 7200-02 Technology Level and Service Pack 7200-02-02-1832, or later
- AIX Version 7.1 with the 7100-05 Technology Level and Service Pack 7100-05-02-1832, or later
- AIX Version 7.2 with the 7200-03 Technology Level, or later (planned availability September 14, 2018)
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 6100-09-12-1838, or later (planned availability September 14, 2018)( AIX 6.1 service extension required)
- AIX Version 7.2 with the 7200-01 Technology Level and Service Pack 7200-01-05-1845, or later (planned availability January 31, 2019)
- AIX Version 7.1 with the 7100-04 Technology Level and Service Pack 7100-04-07-1845, or later (planned availability January 31, 2019)
If installing the AIX operating system Virtual I/O only LPAR (one of these):
- AIX Version 7.2 with the 7200-03 Technology Level, or later (planned availability September 14, 2018)
- AIX Version 7.2 with the 7200-02 Technology Level and Service Pack 7200-02-01-1732, or later
- AIX Version 7.2 with the 7200-01 Technology Level and Service Pack 7200-01-01-1642, or later
- AIX Version 7.1 with the 7100-05 Technology Level and Service Pack 7100-05-01-1731, or later
- AIX Version 7.1 with the 7100-04 Technology Level and Service Pack 7100-04-02-1614, or later
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 6100-09-07-1614, or later ( AIX 6.1 service extension required)
See the Power Systems Prerequisites website for compatibility information for hardware features and the corresponding AIX and IBM i Technology Levels.
If installing the Linux operating system (one of these):
- Red Hat Enterprise Linux 7.5 for Power LE (p8compat), or later
- Red Hat Enterprise Linux for SAP with Red Hat Enterprise Linux 7 for Power LE version 7.5, or later
- SUSE Linux Enterprise Server for SAP with SUSE Linux Enterprise Server 11 Service Pack 4, or later
- SUSE Linux Enterprise Server 12 Service Pack 3, or later
- SUSE Linux Enterprise Server for SAP with SUSE Linux Enterprise Server 12 Service Pack 3, or later
- SUSE Linux Enterprise Server 15, or later
Note: The above list applies to the installation of the Linux operating system LPAR in nonproduction SAP HANA implementations. See the Statement of general direction for IBM Power System E950 (9040-MR9) for SAP HANA Production Use.
If installing VIOS:
- VIOS 2.2.6.23, or later
Java is supported on POWER9 servers. For best use of the performance capabilities and the most recent improvements of POWER9 technology, IBM recommends upgrading Java -based applications to Java 7, Java 8, or later, whenever possible. For those clients who want to run Java in AIX environments, see the AIX Download and service information website.
For Linux (including PowerLinux ), see the Linux Download information website.
Recommendation: Clients are strongly encouraged to move to a more current supported version: Java 7, Java 7.1, Java 8, or later.
Limitations
- The PCIe I/O Expansion Drawer (#EMX0) will be limited to a maximum of two for August 7, 2018, announcement.
- IBM Power System 9040-MR9 Rack does not support earthquake regions.
Planning information
Cable orders
No additional cables are required.
Security, auditability, and control
This product uses the security and auditability features of host hardware, host software, and application software.
The client is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.
IBM Systems Lab Services
For details on available services, contact your IBM representative or go to the IBM Systems Lab Services website.
IBM Electronic Services
IBM has transformed its delivery of hardware and software support services to help you achieve higher system availability. Electronic Services is a web-enabled solution that offers an exclusive, no-additional-charge enhancement to the service and support available for IBM servers. These services are designed to provide the opportunity for greater system availability with faster problem resolution and preemptive monitoring. Electronic Services comprises two separate, but complementary, elements: Electronic Services news page and Electronic Services Agent.
The Electronic Services news page is a single internet entry point that replaces the multiple entry points traditionally used to access IBM Internet services and support. The news page enables you to gain easier access to IBM resources for assistance in resolving technical problems.
The Electronic Service Agent is no-additional-charge software that resides on your server. It monitors events and transmits system inventory information to IBM on a periodic, client-defined timetable. The Electronic Service Agent automatically reports hardware problems to IBM . Early knowledge about potential problems enables IBM to deliver proactive service that may result in higher system availability and performance. In addition, information collected through the Service Agent is made available to IBM service support representatives when they help answer your questions or diagnose problems. Installation and use of IBM Electronic Service Agent for problem reporting enables IBM to provide better support and service for your IBM server.
To learn how Electronic Services can work for you, go to the IBM Electronic Service Agent website.
Terms and conditions
Volume orders
Contact your IBM representative.
IBM Global Financing
Yes
Products - terms and conditions
Warranty period
Warranty and Additional Coverage Options: | Coverage summary: |
---|---|
Warranty period: | 3 years (1 year of standard warranty + 2 additional years of extended support and warranty services upgrade) 1 |
Service Level: | IBM On-Site Repair, 24x7 Same Day |
Service Upgrade options : | |
Warranty Service Upgrade | IBM On-Site Repair, Same Day, 2 hour response 2 |
Maintenance Services (Post-Warranty): | IBM On-Site Repair, Same Day |
IBM Hardware Maintenance Services - committed maintenance 3 : | Y |
- 1 Known exception:
- China:
- Warranty period: 1 Year
- Service Level: 9x5 Next Business Day
- 2 Offered in US only
- 3 Not offered in the US.
To obtain copies of the IBM Statement of Limited Warranty, contact your reseller or IBM . An IBM part or feature installed during the initial installation of an IBM machine is subject to the full warranty period specified by IBM . An IBM part or feature that replaces a previously installed part or feature assumes the remainder of the warranty period for the replaced part or feature. An IBM part or feature added to a machine without replacing a previously installed part or feature is subject to a full warranty. Unless specified otherwise, the warranty period, type of warranty service, and service level of a part or feature are the same as those for the machine in which it is installed.
Any IBM mainstream devices (previously called read intensive device ) identified in this document have a maximum number of write cycles. IBM mainstream device failures will be replaced during standard warranty and maintenance period for devices that have not reached the maximum number of write cycles. Devices that reach this limit may fail to operate according to specifications and must be replaced at the client's expense. Individual service life may vary and can be monitored using an operating system command.
Extended Warranty Service
This product is provided with one year of standard warranty 4 .
For your convenience, IBM has provided two additional years of extended warranty services, plus an upgrade to 24x7 coverage to make this offering. Consult with your advisers about the appropriate financial treatment for this offering.
4 Clients have a choice whether or not to accept the additional two years of extended warranty services plus the upgrade that IBM has provided for this offering. If the choice is to not accept the stated extended warranty services and/or the upgrade, contact your adviser about pricing and other options.
Warranty Services
If required, IBM provides repair or exchange service depending on the types of warranty service specified for the machine. IBM will attempt to resolve your problem over the telephone, or electronically through an IBM website. Certain machines contain remote support capabilities for direct problem reporting, remote problem determination, and resolution with IBM . You must follow the problem determination and resolution procedures that IBM specifies. Following problem determination, if IBM determines on-site service is required, scheduling of service will depend upon the time of your call, machine technology and redundancy, and availability of parts. If applicable to your product, parts considered Customer Replaceable Units (CRUs) will be provided as part of the machine's standard warranty service.
Service levels are response-time objectives and are not guaranteed. The specified level of warranty service may not be available in all worldwide locations. Additional charges may apply outside IBM 's normal service area. Contact your local IBM representative or your reseller for country-specific and location-specific information.
CRU Service
IBM provides replacement CRUs to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request. CRUs are designated as being either a Tier 1 (mandatory) or a Tier 2 (optional) CRU.
Tier 1 (mandatory) CRU
Installation of Tier 1 CRUs, as specified in this announcement, is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation.
The following parts have been designated as Tier 1 CRUs:
- Keyboard
- Mouse
- Display
- Fan
- Disk Drive
- RDX drive
- NVMe carrier card
- NVMe flash module
- Op Panel - Base
- Op Panel - LCD
- TOD Battery
- IO Cassette
- PCIe adapter
- Power Supply
- FSP Card
- Memory Riser
- Memory DIMM
- Memory VRM
- IO VRM
- Processor VRM
- TPM Card
- Front Bezel
- Power Cable
- Service Cover
Tier 2 (optional) CRU
You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge.
Based upon availability, CRUs will be shipped for next-business-day (NBD) delivery. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM . When return is required, return instructions and a container are shipped with the replacement CRU. You may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.
The following parts have been designated as Tier 2 CRUs:
Processor module
CRU and On-site Service
At IBM 's discretion, you will receive specified CRU service, or IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.
Service level is:
- 24 hours per day, 7 days a week, , same-day response. Same day service level includes the installation of Tier 1 CRUs at no additional charge
Warranty services
IBM is now shipping machines with selected non- IBM parts that contain an IBM field replaceable unit (FRU) part number label. These parts are to be serviced during the IBM machine warranty period. IBM is covering the service on these selected non- IBM parts as an accommodation to their customers, and normal warranty service procedures for the IBM machine apply.
International Warranty Service
International Warranty Service allows you to relocate any machine that is eligible for International Warranty Service and receive continued warranty service in any country where the IBM machine is serviced. If you move your machine to a different country, you are required to report the machine information to your Business Partner or IBM representative.
The warranty service type and the service level provided in the servicing country may be different from that provided in the country in which the machine was purchased. Warranty service will be provided with the prevailing warranty service type and service level available for the eligible machine type in the servicing country, and the warranty period observed will be that of the country in which the machine was purchased.
The following types of information can be found on the International Warranty Service website
- Machine warranty entitlement and eligibility
- Directory of contacts by country with technical support contact information
- Announcement Letters
Warranty service upgrades
During the warranty period, warranty service upgrades provide an enhanced level of On-site Service for an additional charge. Service levels are response-time objectives and are not guaranteed. See the Warranty services section for additional details.
IBM will attempt to resolve your problem over the telephone or electronically by access to an IBM website. Certain machines contain remote support capabilities for direct problem reporting, remote problem determination, and resolution with IBM . You must follow the problem determination and resolution procedures that IBM specifies. Following problem determination, if IBM determines on-site service is required, scheduling of service will depend upon the time of your call, machine technology and redundancy, and availability of parts.
CRU and On-site Service
At IBM 's discretion, you will receive CRU service or IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.
The following on-site response-time objectives are available as warranty service upgrades for your machine. Available offerings are:
- On-Site Repair, 7 days a week, 24 hrs/day, 2-hour response objective. Response times are objectives and are not guaranteed.
Customer Replaceable Units (CRUs) may be provided as part of the machine's standard warranty CRU Service except that you may install a CRU yourself or request IBM installation, at no additional charge, under the CRU and On-site Service level specified above. For additional information on the CRU Service, see the warranty information.
If required, IBM provides repair or exchange service depending on the types of maintenance service specified for the machine. IBM will attempt to resolve your problem over the telephone or electronically, through an IBM website. Certain machines contain remote support capabilities for direct problem reporting, remote problem determination, and resolution with IBM . You must follow the problem determination and resolution procedures that IBM specifies. Following problem determination, if IBM determines on-site service is required, scheduling of service will depend upon the time of your call, machine technology and redundancy, and availability of parts. Service levels are response-time objectives and are not guaranteed. The specified level of maintenance service may not be available in all worldwide locations. Additional charges may apply outside IBM 's normal service area. Contact your local IBM representative or your reseller for country-specific and location-specific information.
The following service selections are available as maintenance options, at additional cost, for your machine type.
- On-Site Repair, Monday through Friday (excluding holidays), 8:00 AM to 5:00 PM, next business day.
- On-Site Repair, Monday through Friday (excluding holidays), 8:00 AM to 5:00 PM, 4-hour response objective. Response times are objectives and are not guaranteed.
- On-Site Repair, 7 days a week, 24 hrs/day 5 .
- On-Site Repair, 7 days a week, 24 hrs/day, 2 hour response objective. Response times are objectives and are not guaranteed.
5 Recommended for this product.
IBM
Hardware Maintenance
Services - committed maintenance
6
Organizations can lose as much as USD $100 million per year to downtime related to information and communications technology. IBM Hardware Maintenance Services -- committed maintenance can deliver different types of hardware service for IBM equipment from the moment you call for support worldwide (based on the countries in which IBM has a presence) and around the clock. Through clear response targets and standardized service-delivery metrics, we can help you optimize your IT infrastructure and can help reduce the threat of hardware-related outages.
For more information, see the IBM Hardware Maintenance Services - committed maintenance Data Sheet (D) - USEN .
6 Currently not available in the US.
On-site Service
IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well-lit, and suitable for the purpose.
Customer Replaceable Unit (CRU) Service
If your problem can be resolved with a CRU (for example, keyboard, mouse, speaker, memory, or hard disk drive), and depending upon the maintenance service offerings in your geography, IBM will ship the replacement CRU to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request.
CRUs will be shipped based upon availability. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM . When return is required, 1) return instructions and a container are shipped with the replacement CRU, and 2) you may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.
CRUs are designated as being either a Tier 1 (mandatory) or a Tier 2 (optional) CRU.
Tier 1 (mandatory) CRUs: Installation of Tier 1 CRUs, as specified in this announcement, is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation.
For machines with On-site Same-day Response Service, IBM will replace a Tier 1 CRU part at your request, at no additional charge.
The following parts have been designated as Tier 1 CRUs:
- Keyboard
- Mouse
- Display
- Fan
- Disk Drive
- RDX drive
- NVMe carrier card
- NVMe flash module
- Op Panel Base
- Op Panel LCD
- TOD Battery
- IO Cassette
- PCIe adapter
- Power Supply
- FSP Card
- Memory Riser
- Memory DIMM
- Memory VRM
- IO VRM
- Processor VRM
- TPM Card
- Front Bezel
- Power Cable
- Service Cover
Tier 2 (optional) CRUs: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge.
Non- IBM parts service
Under certain conditions, IBM provides services for selected non- IBM parts at no additional charge for machines that are covered under warranty service upgrades or maintenance services.
This service includes hardware problem determination (PD) on the non- IBM parts (for example, adapter cards, PCMCIA cards, disk drives, memory) installed within IBM machines and provides the labor to replace the failing parts at no additional charge.
If IBM has a Technical Service Agreement with the manufacturer of the failing part, or if the failing part is an accommodations part (a part with an IBM FRU label), IBM may also source and replace the failing part at no additional charge. For all other non- IBM parts, customers are responsible for sourcing the parts. Installation labor is provided at no additional charge, if the machine is covered under a warranty service upgrade or a maintenance service.
Usage plan machine
No
IBM hourly service rate classification
Two
When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order.
General terms and conditions
Field-installable features
Yes
Model conversions
Yes
Machine installation
Customer setup. Customers are responsible for installation according to the instructions IBM provides with the machine.
Graduated program license charges apply
No
Licensed Machine Code
IBM Machine Code is licensed for use by a customer on the IBM machine for which it was provided by IBM under the terms and conditions of the IBM License Agreement for Machine Code, to enable the machine to function in accordance with its specifications, and only for the capacity authorized by IBM and acquired by the customer. You can obtain the agreement by contacting your IBM representative. It can also be found on the License Agreement for Machine Code and Licensed Internal Code.
Access to Machine Code updates is conditioned on entitlement and license validation in accordance with IBM policy and practice. IBM may verify entitlement through customer number, serial number, electronic restrictions, or any other means or methods employed by IBM in its discretion.
If the machine does not function as warranted and your problem can be resolved through your application of downloadable Machine Code, you are responsible for downloading and installing these designated Machine Code changes as IBM specifies. If you would prefer, you may request IBM to install downloadable Machine Code changes; however, you may be charged for that service.
Machine Code License Acceptance Requirement
B.) Acceptance-By-Use Machine: No, the Machine Code license requires signed acceptance by the machine's end user directly with IBM , applicable to orders for a new machine, machine type conversion MES, and to machines transferred to another user.
Educational allowance
A reduced charge is available to qualified education customers. The educational allowance may not be added to any other discount or allowance.
The educational allowance is 5% for the products in this announcement.
Prices
For additional information and current prices, contact your local IBM representative.
The following are newly announced features on the specific models of the Power Systems 9040 machine type:
Minimum Initial/ Monthly MES/ Model Feature Purchase Maint. Both/ RP Description number number price Charge Support CSU MES
IBM Power System E950 MR9 Yes
One CSC Billing Unit MR9 0010 Both Yes No Ten CSC Billing Units MR9 0011 Both Yes No
AIX Partition Specify MR9 0265 Both Yes No Linux Partition Specify MR9 0266 Both Yes No V.24/EIA232 6.1m (20 Ft) PCI C MR9 0348 Both Yes No V.35 6.1m (20 Ft) PCI Cable MR9 0353 Both Yes No X.21 6.1m (20 Ft) PCI Cable MR9 0359 Both Yes No
UPS Factory Integration Spcfy MR9 0373 MES Yes No HMC Factory Integration Spcfy MR9 0374 MES Yes No Display Factory Int. Specify MR9 0375 MES Yes No Rack Space for UPS MR9 0376 MES Yes No Reserve Rack for HMC MR9 0377 MES Yes No Reserve Rack Space for Display MR9 0378 MES Yes No Customer Specified Placement MR9 0456 Initial N/A No 19 inch, 1.8 meter high rack MR9 0551 MES Yes No 19 inch, 2.0 meter high rack MR9 0553 MES Yes No Rack Filler Panel Kit MR9 0599 Both Yes No Load Source Not in CEC MR9 0719 Both Yes No SAN Load Source Specify MR9 0837 Both Yes No
US TAA Compliance Indicator MR9 0983 Both N/A No Asm in USA manufacturing plant MR9 0984 Both Yes No
Modem Cable US/Canada and GU MR9 1025 Both Yes No USB 500 GB Removable Disk Dr MR9 1107 Both Yes No 3m, Blue Cat5e Cable MR9 1111 Both Yes No 10m, Blue Cat5e Cable MR9 1112 Both Yes No 25m, Blue Cat5e Cable MR9 1113 Both Yes No Custom Serv. Specify, Roch MR9 1140 Both Yes No Quantity 150 of #1964 MR9 1818 Both Yes No Quantity 150 of #1953 MR9 1929 Both Yes No 300GB 15k RPM SAS SFF-2 Disk MR9 1953 Both Yes No 600GB 10k RPM SAS SFF-2 Disk MR9 1964 Both Yes No Primary OS AIX MR9 2146 Both Yes No Primary OS Linux MR9 2147 Both Yes No LC-SC 50 Micron Fiber Conv Cab MR9 2456 Both Yes No LC-SC 62.5 Mic.Fib.Conv.Cable MR9 2459 Both Yes No Asynch.Termin/Print.Cbl EIA232 MR9 2934 Both Yes No Asynchronous Cable EIA 232/V MR9 2936 Both Yes No Ser to Ser Port Cab Draw/Draw MR9 3124 Both Yes No Serial to Se.Port Cbl Rack 8M MR9 3125 Both Yes No Widescreen LCD Monitor MR9 3632 Support Yes No 0.3M Serial Prt Converter Cbl MR9 3925 Both Yes No Serial Port Null Mod Cab 3.7M MR9 3927 Both Yes No Ser.Port Null Modem Cable,10M MR9 3928 Both Yes No System Serial Port Converter C MR9 3930 Both Yes No 6Foot Extend.Cbl for Displays MR9 4242 Support Yes No Extender Cable USB Keybo 1.8M MR9 4256 Both Yes No VGA to DVI Connection Converte MR9 4276 Both Yes No Power Cord To PDU/UPS MR9 4558 Both Yes No Rack Integration Services: BP MR9 4648 Initial N/A No Rack Integration Services MR9 4649 Initial N/A No One and only one rack indicator feature is required onall orders (#4650 to #4666). No Factory Integration Ind. MR9 4650 Initial N/A No Software Preload Required MR9 5000 Initial N/A No PCIe2 8Gb 4-port Fibre Channel MR9 5729 Both Yes No 8 Gigabit PCI Express Dual Por MR9 5735 Both Yes No PCIe2 4-port 1GbE Adapter MR9 5899 Both Yes No Opt Front Door for 1.8m Rack MR9 6068 MES Yes No Opt Front Door for 2.0m Rack MR9 6069 MES Yes No 1.8m Rack Acoustic Doors MR9 6248 MES Yes No 2.0m Rack Acoustic Doors MR9 6249 MES Yes No 1.8m Rack Trim Kit MR9 6263 MES Yes No 2.0m Rack Trim Kit MR9 6272 MES Yes No Pwr Crd 4.3m 14ft to IBM PDU MR9 6458 Both Yes No Pwr Crd (14FT), Drwr - OEM PDU MR9 6460 Both Yes No Pwr Crd 4.3m 14ft Wall OEM PDU MR9 6469 Both Yes No Pwr Crd 1.8m 6ft Wall 125V/15A MR9 6470 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6471 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6472 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6473 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6474 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6475 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6476 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6477 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6478 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6488 Both Yes No 4.3m (14 Ft) 3PH/24A Power Cor MR9 6489 Both Yes No 4.3m (14 Ft) 1PH/63A Pwr Cord MR9 6491 Both Yes No 4.3m (14 Ft) 1PH/48 60A Pwr Co MR9 6492 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6493 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6494 Both Yes No Pwr Crd 2.7m 9ft Wall 250V,10A MR9 6496 Both Yes No Power Cable Drawer to IBM PD MR9 6577 Both Yes No Optional Rack Security Kit MR9 6580 MES Yes No Pwr Crd 2.7m 9ft Wall 125V,15A MR9 6651 Both Yes No 4.3m 3PH/16A Power Cord MR9 6653 Both Yes No 4.3m 1PH/24-30A Pwr Cord MR9 6654 Both Yes No 4.3m 14Ft 1PH/24 30A WR Pwr MR9 6655 Both Yes No 4.3m 14Ft 1PH/24A Power Cord MR9 6656 Both Yes No 4.3m 14Ft 1PH/32A Power Cord MR9 6657 Both Yes No 4.3m 14Ft 1PH/24A Pwr Cd Kor MR9 6658 Both Yes No Pwr.Cord(9ft),To Wall/OEM PDU MR9 6659 Both Yes No Pwr Crd 14ft 4.3m WallOEM PDU MR9 6660 Both Yes No Pwr Crd 2.8m 9.2ft PDU MR9 6665 Both Yes No 4.3m 14Ft 3PH/32A Pwr Cd Aus MR9 6667 Both Yes No Pwr Crd 4.3M, Drwr - OEM PDU MR9 6669 Both Yes No Pwr Crd 2.7m, Drwr - IBM PDU MR9 6671 Both Yes No Pwr Crd 2M, Drwr - IBM PDU MR9 6672 Both Yes No Pwr Crd 2.7m 9ft Wall OEM PDU MR9 6680 Both Yes No Environmental Monitoring Probe MR9 7118 Both Yes No Eth Cbl 15M HW Management MR9 7802 Both Yes No Linux Software Preinstall MR9 8143 Initial N/A No Linux Software Preinstall BP MR9 8144 Initial N/A No USB Mouse MR9 8845 Support Yes No Order Routing Indicator Syste MR9 9169 Initial N/A No Language Group Spcf-US Eng MR9 9300 Initial N/A No New AIX License Core Counter MR9 9440 Initial N/A No New Red Hat Lic Core Counter MR9 9442 Initial N/A No New SUSE Lic Core Counter MR9 9443 Initial N/A No Other AIX Lic Core Counter MR9 9444 Initial N/A No Other Linux Lic Core Counter MR9 9445 Initial N/A No 3rd Party Linux Lic Core Cnt MR9 9446 Initial N/A No VIOS Core Counter MR9 9447 Initial N/A No Other License Core Counter MR9 9449 Initial N/A No Ubuntu Linux License Core Cntr MR9 9450 Initial N/A No Month Indicator MR9 9461 Initial N/A No Day Indicator MR9 9462 Initial N/A No Hour Indicator MR9 9463 Initial N/A No Minute Indicator MR9 9464 Initial N/A No Qty Indicator MR9 9465 Initial N/A No Countable Member Indicator MR9 9466 Initial N/A No Language Group Spcf-Dutch MR9 9700 Initial N/A No Language Group Spcf-French MR9 9703 Initial N/A No Language Group Spcf-German MR9 9704 Initial N/A No Language Group Spcf-Polish MR9 9705 Initial N/A No Lang Group Specify - Norwegian MR9 9706 Initial N/A No Lang.Group Spcf-Portuguese MR9 9707 Initial N/A No Language Group Spcf-Spanish MR9 9708 Initial N/A No Language Group Spcf-Italian MR9 9711 Initial N/A No Langua Gr Speci Canadian Frenc MR9 9712 Initial N/A No Language Group Spcf-Japanese MR9 9714 Initial N/A No Language Group Specify Tr Chin MR9 9715 Initial N/A No Language Group Spcf-Korean MR9 9716 Initial N/A No Language Group Spcf-Turkish MR9 9718 Initial N/A No Language Group Spcf-Hungarian MR9 9719 Initial N/A No Language Group Spcf-Slovakian MR9 9720 Initial N/A No Language Group Spcf-Russian MR9 9721 Initial N/A No Lang Group Spcf Simpl Chinese MR9 9722 Initial N/A No Language Group Spcf-Czech MR9 9724 Initial N/A No Language Group Spcf-Romanian MR9 9725 Initial N/A No Lang Group Specify - Croatian MR9 9726 Initial N/A No Language Group Spcf-Slovenian MR9 9727 Initial N/A No Lang Group Specify - Braz Port MR9 9728 Initial N/A No Lang Group Specify - Thai MR9 9729 Initial N/A No QSFP+ 40GbE Transceiver MR9 EB27 Both Yes No 1m Passive QSFP+ to QSFP+ Cbl MR9 EB2B Both Yes No 3m Passive QSFP+ to QSFP+ Cbl MR9 EB2H Both Yes No 10m QSFP+ MTP Optical Cable MR9 EB2J Both Yes No 30m QSFP+ MTP Optical Cable MR9 EB2K Both Yes No Lift Tool MR9 EB2Z Both Yes No Power Supply 2000W 200-240 VAC MR9 EB3M Both Yes No Lift tool GenieLift GL-8 MR9 EB3Z Both Yes No 10GbE Optical Transc SFP+ SR MR9 EB46 Both Yes No 25GbE Opt Transceiver SFP28 MR9 EB47 Both Yes No 0.5 SFP/25GbE CU Cable MR9 EB4J Both Yes No 1.0 SFP/25GbE CU Cable MR9 EB4K Both Yes No 1.5 SFP/25GbE CU Cable MR9 EB4L Both Yes No 2.0 SFP/25GbE CU Cable MR9 EB4M Both Yes No 2.5 QSFP28/100GbE CU Cable MR9 EB4P Both Yes No Service wedge shelf for EB3Z MR9 EB4Z Both No No 0.5m EDR IB Copper Cable MR9 EB50 Both Yes No 1.0m EDR IB Copper Cable MR9 EB51 Both Yes No 2.0M EDR IB Copper Cable MR9 EB52 Both Yes No 1.5M EDR IB Copper Cable MR9 EB54 Both Yes No 100GbE Optic Transceiver QSFP28 MR9 EB59 Both Yes No 3M EDR IB Optical Cable MR9 EB5A Both Yes No 5M EDR IB Optical Cable MR9 EB5B Both Yes No 10M EDR IB Optical Cable MR9 EB5C Both Yes No 15M EDR IB Optical Cable MR9 EB5D Both Yes No 20M EDR IB Optical Cable MR9 EB5E Both Yes No 30M EDR IB Optical Cable MR9 EB5F Both Yes No 50M EDR IB Optical Cable MR9 EB5G Both Yes No 100M EDR IB Optical Cable MR9 EB5H Both Yes No 0.5M 100GbE Cu Cable QSFP28 MR9 EB5J Both Yes No 1.0M 100GbE Cu Cable QSFP28 MR9 EB5K Both Yes No 1.5M 100GbE Cu Cable QSFP28 MR9 EB5L Both Yes No 2.0M 100GbE Cu Cable QSFP28 MR9 EB5M Both Yes No 3M 100GbE Optic Cable QSFP28 MR9 EB5R Both Yes No 5M 100GbE Optic Cable QSFP28 MR9 EB5S Both Yes No 10M 100GbE Optic Cable QSFP28 MR9 EB5T Both Yes No 15M 100GbE Optic Cable QSFP28 MR9 EB5U Both Yes No 20M 100GbE Optic Cable QSFP28 MR9 EB5V Both Yes No 30M 100GbE Optic Cable QSFP28 MR9 EB5W Both Yes No 50M 100GbE Optic Cable QSFP28 MR9 EB5X Both Yes No 100M 100GbE Optic Cable QSFP28 MR9 EB5Y Both Yes No Rack Front Door (Black) MR9 EC01 MES Yes No Rack Rear Door MR9 EC02 MES Yes No Rack Side Cover MR9 EC03 MES Yes No Rack Suite Attachment Kit MR9 EC04 MES Yes No Slim Rear Acoustic Door MR9 EC07 MES Yes No Slim Front Acoustic Door MR9 EC08 MES Yes No Rear Door Heat Exchanger MR9 EC15 MES Yes No PCIe3 2-Port 10Gb NIC&ROCE MR9 EC2S Both Yes No PCIe3 2-Port 25/10Gb NIC&Ro MR9 EC2U Both Yes No Mainstream 800GB SSD NVMe MR9 EC5J Both Yes No Mainstream 1.6TB SSD NVMe MR9 EC5K Both Yes No Mainstream 3.2TB SSD NVMe MR9 EC5L Both Yes No PCIe4 2-port 100Gb ROCE EN MR9 EC66 Both Yes No 0.6m Blue CAT5 Ethernet Cable MR9 ECB0 Both Yes No 1.5m Blue CAT5 Ethernet Cable MR9 ECB2 Both Yes No SAS X Cable 3m - HD Narrow MR9 ECBJ Both Yes No SAS X Cable 6m - HD Narrow MR9 ECBK Both Yes No SAS X Cable 10m - HD Narrow MR9 ECBL Both Yes No SAS X Cable 15m -HD Narrow 3Gb MR9 ECBM Both Yes No SAS YO Cable 1.5m - HD Narrow MR9 ECBT Both Yes No SAS YO Cable 3m - HD Narrow MR9 ECBU Both Yes No SAS YO Cable 6m - HD Narrow MR9 ECBV Both Yes No SAS YO Cable 10m - HD Narrow MR9 ECBW Both Yes No SAS YO Cable 15m-HD Narrow 3Gb MR9 ECBX Both Yes No SAS AE1 Cable 4m - HD Narrow MR9 ECBY Both Yes No SAS YE1 Cable 3m - HD Narrow MR9 ECBZ Both Yes No SAS AA Cable 0.6m - HD Narrow MR9 ECC0 Support Yes No SAS AA Cable 1.5m - HD Narrow MR9 ECC2 Support Yes No SAS AA Cable 3m - HD Narrow MR9 ECC3 Support Yes No SAS AA Cable 6m - HD Narrow MR9 ECC4 Support Yes No 3M Optical Cable Pair MR9 ECC7 Both Yes No 10M Optical Cable Pair MR9 ECC8 Both Yes No Port Converter Cable for UPS MR9 ECCF Both N/A No 3M Copper CXP Cable Pair MR9 ECCS Both Yes No 3.0M SAS X12 Cable MR9 ECDJ Both Yes No 4.5M SAS X12 Cable MR9 ECDK Both Yes No 10M SAS X12 Cable MR9 ECDL Both Yes No 1.5M SAS YO12 Cable MR9 ECDT Both Yes No 3.0M SAS YO12 Cable MR9 ECDU Both Yes No 4.5M SAS YO12 Cable MR9 ECDV Both Yes No 10M SAS YO12 Cable MR9 ECDW Both Yes No 0.6M SAS AA12 Cable MR9 ECE0 Both Yes No 3.0M SAS AA12 Cable MR9 ECE3 Both Yes No 4.5M SAS AA12 Cable MR9 ECE4 Both Yes No Cloud Private Solution MR9 ECP0 Initial N/A No 2.0 M Slim Rack MR9 ECR0 MES Yes No Rack Front Door MR9 ECRF MES Yes No Rack Rear Door Black MR9 ECRG MES Yes No Rack Side Cover MR9 ECRJ MES Yes No Rack Rear Extension 5-In MR9 ECRK MES Yes No Rack Front Door (Black/Flat) MR9 ECRM MES Yes No Custom Serv. Specify, France MR9 ECSF Both Yes No Custom Serv. Specify, Mexico MR9 ECSM Both Yes No Custom Serv. Spec Poughkeepsie MR9 ECSP Both Yes No Optical Wrap Plug MR9 ECW0 Both Yes No
Healthcare 3.15 GHz, 12-core MR9 EHC4 Initial N/A No
SAP HANA TRACKING FEAT MR9 EHKV Initial N/A No Boot Drive in EXP12SX Specify MR9 EHR1 Both N/A No Boot / Load in EXP24SX Specify MR9 EHR2 Both N/A No SSD Placement Ind- #ESLS/#ELLS MR9 EHS2 Both Yes No PCIe3 Optical Cable Adapter MR9 EJ08 Both Yes No Backplane 8-SAS Zero DASD MR9 EJ0B Both No No PCIe3 RAID SAS Adapter 4-port MR9 EJ0J Support Yes No PCIe3 RAID SAS Ad 4-port MR9 MR9 EJ0K Both Yes No PCIe3 SAS Tape/DVD Adapter MR9 EJ10 Both Yes No PCIe3 12GB Cache RAID+ SAS Ada MR9 EJ14 Both Yes No PCIe3 Crypto Coproc BSC-3 4767 MR9 EJ33 Both Yes No Backplane base 8-SAS HDD/SDD MR9 EJBB Both No No Non-paired Indicator EJ0L PCIe MR9 EJRL Both Yes No Backplane spli 8-SAS HDD/SDD MR9 EJSB Both No No Specify Mode-1 for EXP12SX 1&1 MR9 EJV1 Both Yes No Specify Mode-1 for EXP12SX 2&2 MR9 EJV2 Both Yes No Specify Mode-2 for EXP12SX 2&2 MR9 EJV3 Both Yes No Specify Mode-2 for EXP12SX 4&2 MR9 EJV4 Both Yes No Specify Mode-4 for EXP12SX 4&2 MR9 EJV5 Both Yes No Specify Mode-2 for EXP12SX 1&2 MR9 EJV6 Both Yes No Specify Mode-2 for EXP12SX 2&2 MR9 EJV7 Both Yes No Specify Mode-2 for EXP12SX 1&1 MR9 EJVA Both Yes No Specify Mode-2 for EXP12SX 2&1 MR9 EJVB Both Yes No Specify Mode-4 for EXP12SX 1&1 MR9 EJVC Both Yes No Specify Mode-4 for EXP12SX 2&1 MR9 EJVD Both Yes No Specify Mode-4 for EXP12SX 3&2 MR9 EJVE Both Yes No Specify Mode-1 for EXP12SX 2&2 MR9 EJVF Both Yes No Speci Mode-2 for EXP12SX 2&2 MR9 EJVW Both Yes No Specify Mode-1 for EXP24SX 1&1 MR9 EJW1 Both Yes No Specify Mode-1 for EXP24SX 2&2 MR9 EJW2 Both Yes No Specify Mode-2 for EXP24SX 2&2 MR9 EJW3 Both Yes No Specify Mode-2 for EXP24SX 4&2 MR9 EJW4 Both Yes No Specify Mode-4 for EXP24SX 4&2 MR9 EJW5 Both Yes No Specify Mode-2 for EXP24SX 1&2 MR9 EJW6 Both Yes No Specify Mode-2 for EXP24SX 2&2 MR9 EJW7 Both Yes No Specify Mode-2 for EXP24SX 1&1 MR9 EJWA Both Yes No Specify Mode-2 for EXP24SX 2&1 MR9 EJWB Both Yes No Specify Mode-4 for EXP24SX 1&1 MR9 EJWC Both Yes No Specify Mode-4 for EXP24SX 2&1 MR9 EJWD Both Yes No Specify Mode-4 for EXP24SX 3&2 MR9 EJWE Both Yes No Specify Mode-1 for EXP24SX 2&2 MR9 EJWF Both Yes No Specify Mode-2 for EXP24SX 2&2 MR9 EJWG Both Yes No Specify Mode-2 for EXP24SX 2&1 MR9 EJWH Both Yes No Specify Mode-2 for EXP24SX 4&2 MR9 EJWJ Both Yes No Spec Mode2 for EEXP24SX 2&2 MR9 EJWW Both Yes No
Base proc act (12) for #EHC4 MR9 ELAN Initial N/A No
1-core Linux Pro Ac for EPWR MR9 ELBG Both Yes No 1-core Linux Pro Ac forEPWT MR9 ELBH Both Yes No PowerVM for Linux indicator MR9 ELBJ Both Yes No 1-core Linux Pro Ac for EPWS MR9 ELBP Both Yes No 1-core Linux Pro Ac for EPWY MR9 ELBR Both Yes No PDU Access Cord 0.38m MR9 ELC0 MES Yes No Power Cord - Drawer to PDU MR9 ELC5 Both Yes No Power IFL Memory Activation MR9 ELNP Both Yes No Memory Riser Card MR9 EM03 Both Yes No 8 GB DDR4 Memory MR9 EM6A Both Yes No 16 GB DDR4 Memory MR9 EM6B Both Yes No 32 GB DDR4 Memory MR9 EM6C Both Yes No 64 GB DDR4 Memory MR9 EM6D Both Yes No 128 GB DDR4 Memory MR9 EM6E Both Yes No Active Memory Mirroring MR9 EM81 Both Yes No 90 Days Elast CoD Mem Ena MR9 EM9U MES Yes No Power Active Mem Expansion MR9 EMAM Both Yes No
128GB Base Mem Act for EHC4 MR9 EMAN Initial N/A No
1GB Memory Activation MR9 EMAP Both Yes No QTY 100 1GB Mem Act MR9 EMAQ Both Yes No 512GB Linux Mem Activation MR9 EMBE Both Yes No VRM DDR4 Memory for MR9 MR9 EMEF Both Yes No 8 GB-Day Bill CoD men MR9 EMJE Both Yes No 800 GB-Day Bill CoD mem MR9 EMJF Both Yes No PCIe Gen3 I/O Expansion Drawer MR9 EMX0 Both Yes No AC Power Supply Conduit MR9 EMXA Both Yes No PCIe3 6-Slot Fanout Module MR9 EMXF Support Yes No PCIe3 6-Slot Fanout Module MR9 EMXG Both Yes No 1m 10GbE Cable SFP+ Act Twinax MR9 EN01 Both Yes No 3m 10GbE Cable SFP+ Act Twinax MR9 EN02 Both Yes No 5m 10GbE Cable SFP+ Act Twinax MR9 EN03 Both Yes No PCIe3 16Gb 2-port Fibre Channe MR9 EN0A Both Yes No PICe3 4-port 10Gb FCoE & 1GbE MR9 EN0H Both Yes No PCIe3 4-port 10GB FCoE & 1GbE MR9 EN0K Both Yes No PCIe2 4-pt(10+1 GbE)SR+RJ45 MR9 EN0S Both Yes No PCIe2 4-pt(10+1GbE)CRSR+RJ45 MR9 EN0U Both Yes No PCIe2 2-pt 10/1GbE BaseT RJ45 MR9 EN0W Both Yes No PCIe2 8Gb 4-port Fibre Channel MR9 EN12 Both Yes No PCIe3 4-port 10GbE SR Adapter MR9 EN15 Both Yes No PCIe3 32Gb 2-port FC Adapter MR9 EN1A Both Yes No PCIe3 16Gb 4-port FC Adapter MR9 EN1C Both Yes No 90 Days Elastic CoDProc Enable MR9 EP9T MES Yes No 1 Proc-day Elast bill EWR MR9 EPN0 Both Yes No 100 Proc-day ECOD bill EPWR MR9 EPN1 Both Yes No 100 Proc-min UCOD bill EPWR MR9 EPN2 Both Yes No 1-core Proc Act for EPWY MR9 EPN3 Both Yes No 1 Proc-day Elast bill EPWS MR9 EPN5 Both Yes No 100 Proc-day ECOD bill EPWS MR9 EPN6 Both Yes No 100 Proc-min UCOD bill EPWS MR9 EPN7 Both Yes No 1 Proc-day Elast bill EPWY MR9 EPN8 Both Yes No 100 Proc-day ECOD bill EPWY MR9 EPN9 Both Yes No 1 Proc-day Elast bill EPWT MR9 EPNK Both Yes No 100 Proc-day ECOD bill EPWT MR9 EPNL Both Yes No 100 Proc-min UCOD bill EPWT MR9 EPNM Both Yes No 100 Proc-min UCOD bill EPWY MR9 EPNN Both Yes No Horizontal PDU Mounting Hardwr MR9 EPTH Both Yes No High Function 9xC19 PDU MR9 EPTJ Both Yes No High Function 9xC19 PDU 3Phase MR9 EPTL Both Yes No High Function 12xC13 PDU MR9 EPTN Both Yes No High Function 12xC13 PDU 3-Phs MR9 EPTQ Both Yes No PowerVM Enterprise Edition MR9 EPVV Both Yes No 8-core 3.6 GHZ processor MR9 EPWR Both No No 10-core 3.4 GHZ processor MR9 EPWS Both No No 12-core 3.15 GHZ processor MR9 EPWT Both No No 1-core Proc Act for EPWR MR9 EPWV Both Yes No 1-core Proc Act for EPWS MR9 EPWW Both Yes No 1-core Proc Act for EPWT MR9 EPWX Both Yes No 11-core 3.2 GHZ processor MR9 EPWY Both No No Qty 150 #ES62 3.86TB LFF Dsk MR9 EQ62 Both Yes No Qty 150 #ES64 7.72TB LFF Dsk MR9 EQ64 Both Yes No Qty 150 of #6577 MR9 EQ77 Both Yes No Qty 150 #ES78 SSD 387GB 5xx MR9 EQ78 Support Yes No Qty 150 #ES7E SSD 775GB 5xx MR9 EQ7E Support Yes No Quantity 150 of ES80 1.9TB SSD MR9 EQ80 Support Yes No Qty 150 #ES85 SSD 387GB 4k MR9 EQ85 Support Yes No Qty 150 #ES8C SSD 775GB 4k MR9 EQ8C Support Yes No Qty 150 #ES8F SSD 1.55TB 4k MR9 EQ8F Support Yes No Quantity 150 of ES8Y 931GB MR9 EQ8Y Both Yes No Quantity 150 of ES96 1.86TB MR9 EQ96 Both Yes No Quantity 150 of #ESE7 3.72TB MR9 EQE7 Both Yes No Quantity 150 of #ESEV 600GB MR9 EQEV Both Yes No Quantity 150 of #ESEZ 300GB MR9 EQEZ Both Yes No Quantity 150 of #ESF3 1.2TB MR9 EQF3 Both Yes No Quantity 150 of #ESFP 600GB MR9 EQFP Both Yes No Quantity 150 of #ESFT 1.8TB MR9 EQFT Both Yes No Quantity 150 of #ESG5 MR9 EQG5 Both Yes No Quantity 150 of #ESGB MR9 EQGB Both Yes No Quantity 150 of #ESGF MR9 EQGF Both Yes No Quantity 150 of #ESGK MR9 EQGK Both Yes No Quantity 150 of #ESGP MR9 EQGP Both Yes No 42U Slim Rack MR9 ER05 MES Yes No RFID Tags for Compute Nodes MR9 ERF1 Initial N/A No Rear rack extension MR9 ERG0 MES Yes No Origami Front Door 2m Rack MR9 ERG7 MES Yes No Quantity 150 of ESHJ MR9 ERHJ Both Yes No Quantity 150 of ESHL MR9 ERHL Both Yes No Quantity 150 of ESHN MR9 ERHN Both Yes No Quantity 150 of ESM8 MR9 ERM8 Both Yes No 3.86TB 7200 RPM SAS LFF Disk MR9 ES62 Both Yes No 7.72TB 7200 RPM SAS LFF Disk MR9 ES64 Both Yes No 387GB SFF-2 SSD 5xx for AIX/L MR9 ES78 Support Yes No 775GB SFF-2 SSD 5xx for AIX/L MR9 ES7E Support Yes No 387GB SFF-3 SSD 5xx for AIX/L MR9 ES7K Support Yes No 775GB SFF-3 SSD 5xx for AIX/L MR9 ES7P Support Yes No 1.9TB RI SAS 4k SFF-2 SSD AIX MR9 ES80 Support Yes No 931GB Mainstream SAS 4k SSD MR9 ES83 Both Yes No 387GB SFF-2 SSD 4k for AIX/Li MR9 ES85 Support Yes No 775GB SFF-2 SSD 4k for AIX/Li MR9 ES8C Support Yes No 1.55TB SFF-2 SSD 4k for AIX/L MR9 ES8F Support Yes No 1.9TB RI SAS 4k SFF-3 SSD AIX MR9 ES8J Support Yes No 387GB SFF-3 SSD 4k for AIX/Li MR9 ES8N Support Yes No 775GB SFF-3 SSD 4k for AIX/Li MR9 ES8Q Support Yes No 1.55TB SFF-3 SSD 4k for AIX/L MR9 ES8V Support Yes No 931GB Mainstream SAS 4k SSD MR9 ES8Y Both Yes No 1.86TB Mainstream SAS 4k SSD MR9 ES92 Both Yes No 1.86TB Mainstream SAS 4k SSD MR9 ES96 Both Yes No S&H - No Charge MR9 ESC0 Both N/A No S&H MR9 ESC7 Initial N/A No 600GB 10K RPM SAS SFF3 Disk MR9 ESD5 Both Yes No 300GB 15K RPM SAS SFF-3 Disk MR9 ESDB Both Yes No 3.72TB Mainstream SAS 4k SSD MR9 ESE1 Both Yes No 3.72TB Mainstream SAS 4k SSD MR9 ESE7 Both Yes No 600GB 10K RPM SFF-2 Disk 4K MR9 ESEV Both Yes No 300GB 15K SAS SFF-2 4K BLK HDD MR9 ESEZ Both Yes No 1.2TB 10K RPM SFF-2 Disk 4K MR9 ESF3 Both Yes No 600GB 10K RPM SFF-3 Disk 4K MR9 ESF5 Both Yes No 1.2TB 10K RPM SFF-3 Disk 4K MR9 ESF9 Both Yes No 300GB 15K SAS SFF-3 4K BLK HDD MR9 ESFB Both Yes No 600GB 15K SAS SFF-3 4K BLK HDD MR9 ESFF Both Yes No 600GB 15K SAS SFF-2 4K BLK HDD MR9 ESFP Both Yes No 1.8TB 10K RPM SFF-2 Disk 4K MR9 ESFT Both Yes No 1.8TB 10K RPM SFF-3 Disk 4K MR9 ESFV Both Yes No 387GB Enterprise SAS 5xx SSD MR9 ESG5 Both Yes No 387GB Enterprise SAS 5xx SSD MR9 ESG9 Both Yes No 387GB Enterprise SAS 4k SSD MR9 ESGB Both Yes No 387GB Enterprise SAS 4k SSD MR9 ESGD Both Yes No 775GB Enterprise SAS 5xx SSD MR9 ESGF Both Yes No 775GB Enterprise SAS 5xx SSD MR9 ESGH Both Yes No 775GB Enterprise SAS 4k SSD MR9 ESGK Both Yes No 775GB Enterprise SAS 4k SSD MR9 ESGM Both Yes No 1.55TB Enterprise SAS 4k SSD MR9 ESGP Both Yes No 1.55TB Enterprise SAS 4k SSD MR9 ESGR Both Yes No 931GB Mainstream SAS 4k SSD MR9 ESHJ Both Yes No 1.86TB Mainstream SAS 4k SSD MR9 ESHL Both Yes No 7.45TB Mainstream SAS 4k SSD MR9 ESHN Both Yes No 931GB Mainstream SAS 4k SSD MR9 ESHS Both Yes No 1.86TB Mainstream SAS 4k SSD MR9 ESHU Both Yes No 7.45TB Mainstream SAS 4k SSD MR9 ESHW Both Yes No Specify AC Power Supply MR9 ESLA Both Yes No EXP12SX SAS Storage Enclosure MR9 ESLL Both Yes No EXP24SX SAS Storage Enclosure MR9 ESLS Both Yes No 3.72TB Mainstream SAS 4k SSD MR9 ESM8 Both Yes No 3.72TB Mainstream SAS 4k SSD MR9 ESMQ Both Yes No 300GB 15K SAS SFF-3 4k HDD MR9 ESNK Both Yes 300GB 15K SAS SFF-2 4k HDD MR9 ESNM Both Yes No 600GB 15K SAS SFF-3 4k HDD MR9 ESNP Both Yes 600GB 15K SAS SFF-2 4k HDD MR9 ESNR Both Yes No Quantity 150 of #ESNM 300GB MR9 ESPM Both Yes Quantity 150 of #ESNR 600GB MR9 ESPR Both Yes 1TB Removable Disk Cartridge MR9 EU01 Both Yes No RDX USB External Docking MR9 EU04 Support Yes No RDX 320 GB Removable Disk Driv MR9 EU08 Support Yes 1.5TB Removable Disk Cartridge MR9 EU15 Support Yes
2TB Removable Disk Cartrdg-RDX MR9 EU2T Both Yes No
RDX USB External Docking Sta MR9 EUA4 Both Yes
Standalone USB DVD drive w/c MR9 EUA5 Both Yes Core Use HW Feature MR9 EUC6 MES Yes No Core Use HW Feature 10 MR9 EUC7 MES Yes No 5000 Cloud Reward Points MR9 SVPC Initial N/A No
The following are newly announced features on the specific models of the Power Systems 7014 and 7965 machine type:
Minimum Initial/ Monthly MES/ Description Model Feature Purchase Maint. Both/ RP Machine type 7014 number number price Charge Support CSU MES
Rack Specify 9040 -4EIA T42 ERCZ Initial N/A
Minimum Initial/ Monthly MES/ Description Model Feature Purchase Maint. Both/ RP Machine type 7965 number number price Charge Support CSU MES
Rack Specify 9040 -4EIA S42 ERCZ Initial N/A No
- CSU = Customer setup
- RP MES = Return parts, miscellaneous equipment specifications
Pricing terms
Prices in the following PDF prices link are suggested list prices on day of announcement for the U.S. only. They are provided for your information only. Dealer prices may vary, and prices may also vary by country. IBM list price does not include tax or shipping and is subject to change without notice.
Annual minimum maintenance charges
Not applicable.
ServiceElect (ESA) charges
For ServiceElect (ESA) maintenance service charges, contact IBM Global Services at 888- IBM -4343 (426-4343).
Model conversion purchase price
Parts removed or replaced become the property of IBM and must be returned.
IBM Global Financing
IBM Global Financing offers competitive financing to credit-qualified customers to assist them in acquiring IT solutions. Offerings include financing for IT acquisition, including hardware, software, and services, from both IBM and other manufacturers or vendors. Offerings (for all customer segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or go to the IBM Global Financing website for more information.
IBM Global Financing offerings are provided through IBM Credit LLC in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government customers. Rates are based on a customer's credit rating, financing terms, offering type, equipment type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension, or withdrawal without notice.
Order now
To order, contact the IBM Digital Sales Center, your local IBM representative, or your IBM Business Partner. To identify your local IBM representative or IBM Business Partner, call 800- IBM -4YOU (426-4968). For more information, contact the IBM Digital Sales Center.
Phone: 800- IBM -CALL (426-2255)
Fax: 800-2IBM-FAX (242-6329)
For IBM representative: askibm@ca.ibm.com
For IBM Business Partner: pwcs@us.ibm.com
IBM
Digital Sales Offices
1177 S Belt Line Rd
Coppell, TX 75019-4642, US
The IBM Digital Sales Center, our national direct marketing organization, can add your name to the mailing list for catalogs of IBM products.
Note: Shipments will begin after the planned availability date.
Trademarks
Power Systems, POWER9, Active Memory, IBM Cloud, PowerLinux, HACMP, PowerVP and Electronic Service Agent are trademarks of IBM Corporation in the United States, other countries, or both.
IBM, Power, AIX, POWER8, PowerVM, POWER, PowerHA, IBM API Connect, WebSphere, PartnerWorld and Global Technology Services are registered trademarks of IBM Corporation in the United States, other countries, or both.
The registered trademark Linux® is used pursuant to a sublicense from the Linux Foundation, the exclusive licensee of Linus Torvalds, owner of the mark on a worldÂwide basis.
Oracle and Java are trademarks of Oracle and/or its affiliates in the United States, other countries, or both.
Other company, product, and service names may be trademarks or service marks of others.
Terms of use
IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this announcement at any time without notice. This announcement is provided for your information only. Additional terms of use are located at
For the most current information regarding IBM products, consult your IBM representative or reseller, or go to the IBM worldwide contacts page