Messages and service system values: History log file size

The History log file size system value is also known as QHSTLOGSIZ. You can use this system value to specify the maximum number of records in the history log.

Quick reference
Location From IBM® Navigator for i, select Configuration and Service > System Values. Right-click on Messages and Service and click Properties, then select the General tab.
Special authority None.
Default value Start of change*DAILY.End of change
Changes take effect The next time a history log is created.
Lockable No.

What can I do with this system value?

You can specify the maximum number of records for each version of the history log. When a version is full (the maximum has been reached), a new version is created. You can save the full (old) version and then delete it.

Create daily (*DAILY)
Select this option if you want a new version of the history log created each day. If a history log reaches the maximum of 10,000,000 records, an additional history log file is created for that day. Therefore, you can have more than one history log file for each day.
Maximum records (1-10,000,000)