Starting device parity protection

The best time to start device parity protection is when you add new or non-configured disk units. The Add a disk unit or disk pool wizard has steps for including disk units in a parity set and starting device parity protection.

Notes:
  • All disk units in a parity set must be the same capacity.
  • Systems with IOAs released before V5R2 of OS/400®, the minimum number of disk units for a RAID 5 parity set is 4. The maximum number of disk units in a parity set is 10.
  • Systems with IOAs released after V5R2 can have a minimum number of 3 disk units for a RAID 5 parity set. The maximum number of disk units in a parity set is 18.
  • The minimum number of disk units in a RAID 6 parity set is 4. The maximum number of disk units in a parity set is 18.

Start of changeFollow these steps to start parity protection using IBM® Navigator for i.End of change

Start of change
  1. Select Configuration and Service from your IBM Navigator for i.
  2. Select All Tasks > Disk Management > Start Parity.
  3. Follow the instructions on the dialog box that is displayed.
End of change