Symptom data required in the SDWA for dump suppression
If the installation is using DAE to suppress duplicate dumps, the recovery routine must provide the following minimum data to enable dump suppression. See z/OS MVS Programming: Assembler Services Guide for more information about dump suppression.
SDWA Field | Data | Example |
---|---|---|
SDWAMODN | Failing module name | IEAVTCXX |
SDWACSCT | Failing CSECT name | IEAVTC22 |
SDWACID | Product or component identifier | SCDMP |
SDWACIB | ||
SDWACIDB | Component identifier base | 5655 |
SDWAREXN | Recovery routine name | IEAVTC2R |
SDWASC | Subcomponent or module subfunction | RSM-PGFIX |