Start of change

Subtype 1

Subtype 1 of record type 113 contains event counter deltas for IBM® System z10™ or later CPCs. You can calculate its location in the SMF record using the following formula:
(address of record type 113 + offset value in field SMF113DOF)
Subtype 1 records are CPU Start of changeor coreEnd of change specific. For each hardware data event collection cycle:

Each event counter represents the number of times a specific event has occurred from the start of the current hardware data event collection cycle or since the previous SMF Type 113 subtype 1 record was written. The system captures the valid counters and places them in the appropriate counter data slot, based on the counter event. If a counter data slot is zero, either the counter event is not defined or the counter event has not occurred in the current collection cycle. For example, counter event 0 is located in the 1st counter data slot, and counter event 9 is in the 10th slot.

End of change