Data set I/O statistics section

Note: I/O response and service time components are recorded in multiples of 128 micro-seconds.
Offsets Name Length Format Description
0 0 S42DSIOR 4 binary Average response time.
4 4 S42DSIOC 4 binary Average I/O connect time. There is one SMF subtype 6 record per data set, and each record has its own S42DSIOC field.
8 8 S42DSIOP 4 binary Average I/O pending time.
12 C S42DSIOD 4 binary Average I/O disconnect time.
16 10 S42DSIOQ 4 binary Average control unit queue time.
20 14 S42DSION 4 binary Total number of I/Os. There is one SMF subtype 6 record per data set, and each record has its own S42DSION field.
24 18 S42DSCND 4 binary Number of cache candidates.
28 1C S42DSSHTS 4 binary Number of cache hits.
32 20 S42DSWCN 4 binary Number of write candidates.
36 24 S42DSWHI 4 binary Number of write hits.
40 28 S42DSSEQ 4 binary Number of sequential I/O operations. Operations counted here are not accumulated in S42DSCND and S42DSWCN.
44 2C S42DSRLC 4 binary Number of record level cache I/O operations.
48 30 S42DSICL 4 binary Number of inhibit cache load I/O operations.
52 34 S42DSDA0 4 binary Average I/O device-active-only time.
56 38 S42DSMXR 4 binary Maximum data set I/O response time.
60 3C S42DSMXS 4 binary Maximum data set service time.
64 40 S42DSRDD 4 binary Average disconnect time for reads.
68 44 S42DSRDT 4 binary Total number of read operations.
Start of change72End of change Start of change48End of change Start of changeS42DSHRDEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeNumber of zHPF read operations.End of change
Start of change76End of change Start of change4CEnd of change Start of changeS42DSHWREnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeNumber of zHPF write operations.End of change
Start of change80End of change Start of change50End of change Start of changeS42DSR1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage response time (one microsecond).End of change
Start of change84End of change Start of change54End of change Start of changeS42DSC1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage I/O connect time (one microsecond). There is one SMF subtype 6 record per data set, and each record has its own S42DSIOC field.End of change
Start of change88End of change Start of change58End of change Start of changeS42DSP1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage I/O pending time (one microsecond).End of change
Start of change92End of change Start of change5CEnd of change Start of changeS42DSD1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage I/O disconnect time (one microsecond).End of change
Start of change96End of change Start of change60End of change Start of changeS42DSQ1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage control unit queue time (one microsecond).End of change
Start of change100End of change Start of change64End of change Start of changeS42DSA1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage I/O device-active-only time (one microsecond).End of change
Start of change104End of change Start of change68End of change Start of changeS42DST1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage disconnect time for reads (one microsecond).End of change
Start of change108End of change Start of change6CEnd of change Start of changeS42DSB1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage device busy time (one microsecond).End of change
Start of change112End of change Start of change70End of change Start of changeS42DSM1UEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeAverage initial command response time (one microsecond).End of change
Start of change116End of change Start of change74End of change Start of changeS42DSIOSEnd of change Start of change4End of change Start of changebinaryEnd of change Start of changeTotal number of read/write operations to Metro Mirror secondary.
Note: I/O operations to the Metro Mirror secondary volume are included in the Data Set I/O reporting fields.
End of change