Control data section

Offsets Name Length Format Description
0 0 R748CLVL 1 binary Gatherer level.
1 1 R748CTYP 6 EBCDIC Control unit type.
7 7 R748CMDL 3 EBCDIC Control unit model.
10 A R748CSER 10 EBCDIC Primary control unit serial number.
20 14 R748CVSN 1 binary Version of link statistics definition:

X'00' = Original version of link statistics
X'01' = Link statistics extended

21 15 R748CAE 3 binary Abend code (SDWACMPC) with:

First 12 bits = System completion code.
Second 12 bits = User completion code.

24 18 R748CRTN 2 binary IDCSS01 return code.
26 1A R748CSC 1 binary Status code:
00
successfully processed.
04
IOS return code. R748CIOC ¬= 0.
08
IDCSS01 return code. R748CRTN ¬= 0.
98
SYSTEM or USER ABEND. R748CAE ¬= 0.
27 1B R748CIOC 1 binary IOS return code. If this field is not zero, no Link Statistic sections are available.
28 1C R748CFDV 2 binary Failing device.
30 1E R748CVOL 6 EBCDIC Volume serial of the device from which statistics are measured.
36 24 R748CDEV 2 EBCDIC Device number of the device from which statistics are measured.
38 26 R748CFLG 1 binary Flags
Bit
Meaning when set
0
Extent pool statistics valid
1-7
Reserved.
39 27   1   Reserved.
40 28 R748CINT 4 binary Number of seconds that passed since the link statistics have been collected for the last time.
44 2C R748CFTM 4 EBCDIC Time when first record was written. Reserved for duration processing.
48 30 R748CFDT 4 EBCDIC Date when first record was written. Reserved for duration processing.
52 34 R748CFCI 4 EBCDIC Interval length of first record. Reserved for duration processing.