Common Section for External Writer

Offsets Name Length Format Description
0 0 SMF6LN3 2 binary Length of the common section, including this field.
2 2 SMF6ROUT 4 binary Output route code (this field is always set to zero). The route code is specified on the /*OUTPUT or DD statement.
6 6 SMF6EFMN 8 EBCDIC Output form number. This field is set regardless of the number of characters in the forms field (SMF6FMN). The form number is specified on the FORM= parameter of the DD statement.
14 E   16   Reserved.
30 1E SMF6JBID 8 EBCDIC Job ID, or transaction ID (for APPC output).
The following fields (up to and including SMF6OTOK) are only present if SMF6INDC is equal to or greater than X'04':
38 26 SMF6STNM 8 EBCDIC This field is not filled in for an output writer.
46 2E SMF6PRNM 8 EBCDIC This field is not filled in for an output writer.
54 36 SMF6DDNM 8 EBCDIC This field is not filled in for an output writer.
62 3E SMF6USID 8 EBCDIC The user ID associated with the job/session that created the data set, or the user ID associated with the transaction ID (for APPC output).
70 46 SMF6SECS 8 EBCDIC The security label of the created data set, or data set level seclabel.
78 4E SMF6PRMD 8 EBCDIC The processing mode of the data set.
86 56 SMF6DSNM 53 EBCDIC The name of the data set being printed.
139 8B   3   Reserved.
142 8E SMF6OTOK 20 EBCDIC Reserved.