Actuals section

Offsets Name Length Format Description
244 F4 SMF26LN3 2 binary Length of actuals section, including this field.
246 F6 SMF26RV4 2   Reserved.
248 F8 SMF26ICD 4 binary Number of input statements for the job. This field includes JCL and SYSIN statements.
252 FC SMF26XLN 4 binary Number of output lines generated to spool. This field if filled in when the job is ended on a JES3 local or global processor.
256 100 SMF26XPU 4 binary Number of punched cards generated to spool. This field is filled in when the job is ended on a JES3 local or global processor.
260 104 SMF26RID 4 EBCDIC Input processor system (CPU) identification.
264 108 SMF26CID 4 EBCDIC Conversion processor system (CPU) identification.
268 10C SMF26XID 4 EBCDIC Execution processor system (CPU) identification.
272 110 SMF26OID 4 EBCDIC Output processor system (CPU) identification.
276 114 SMF26JAF 42   Reserved for job accounting fields.
318 13E NJEJMRID 8 EBCDIC Networking identifier ‘NJEJMR’.
326 146 NJEJMRLN 2 binary Length of data that follows, including this field.
328 148 NJEJOBNO 2   Reserved.
330 14A NJEJOBNM 8 EBCDIC Job name.
338 152 NJEXEQM 8 EBCDIC Processing node name.
346 15A NJEPRGMR 20 EBCDIC Programmer name.
366 16E NJEUSRID 8 EBCDIC Origin or notify identification.
374 176 NJEACCT 8 EBCDIC Networking account number.
382 17E NJEDEPT 8 EBCDIC Programmer's department number.
390 186 NJEBLDG 8 EBCDIC Programmer's building number.
398 18E NJEROOM 8 EBCDIC Programmer's room number.
406 196 NJEXEQU 8 EBCDIC Processing user identifier.
414 19E NJEJOBNX 4 EBCDIC Origin node job number.
418 1A2 SMF26SRC 4 binary Number of spool records.