0 |
0 |
SMF6LN6 |
2 |
binary |
Length of File Transfer section (including this
field). |
2 |
2 |
SMF6BYTE |
4 |
binary |
Total number of bytes transmitted, described in
the section introduction. |
6 |
6 |
SMF6IP1 |
1 |
binary |
1st segment of IP address of target address. If these records are written in IP PrintWay™ extended mode, these fields contain
0. IP PrintWay basic mode
fills in the IP address only when it uses the LPR or direct sockets
protocols to send data to the printer. |
7 |
7 |
SMF6IP2 |
1 |
binary |
2nd segment of IP address of target address. If these records are written in IP PrintWay extended mode, these fields contain
0. IP PrintWay basic mode
fills in the IP address only when it uses the LPR or direct sockets
protocols to send data to the printer. |
8 |
8 |
SMF6IP3 |
1 |
binary |
3rd segment of IP address of target address. If these records are written in IP PrintWay extended mode, these fields contain
0. IP PrintWay basic mode
fills in the IP address only when it uses the LPR or direct sockets
protocols to send data to the printer. |
9 |
9 |
SMF6IP4 |
1 |
binary |
4th segment of IP address of target address. If these records are written in IP PrintWay extended mode, these fields contain
0. IP PrintWay basic mode
fills in the IP address only when it uses the LPR or direct sockets
protocols to send data to the printer. |
10 |
A |
SMF6FTL |
1 |
binary |
File transfer level indicator- Value
- Meaning
- 0
- IP PrintWay basic mode
wrote the record.
- 1
- IP PrintWay extended
mode wrote the record. Fields SMF6ACTL and SMF6ACCT are not present.
- 3
- IP PrintWay extended
mode wrote the record. Fields SMF6ACTL and SMF6ACCT are present.
|
11 |
B |
|
11 |
|
Reserved. |
22 |
16 |
SMF6PQLN |
2 |
binary |
Length of the Print Queue Name field.
When IP PrintWay basic
mode writes the record, SMF6PQLN contains the length of the SMF6PRTQ
field. When IP PrintWay extended
mode writes the record, SMF6PQLN contains the length of the meaningful
portion of SMF6PRTQ. |
24 |
18 |
SMF6PRTQ |
24 |
EBCDIC |
Print Queue Name. If IP PrintWay basic mode writes the record, SMF6PRTQ
is variable in length, with the length as specified in SMF6PQLN.
If IP PrintWay extended
mode writes the record, SMF6PRTQ is always 24 bytes in length and
the print queue name is padded to the right with blanks. SMF6PQLN
can be used to extract the print queue name from SMF6PRTQ. |
48 |
30 |
SMF6BYTD |
8 |
binary |
For IP PrintWay extended mode, the total bytes
transmitted (64-bit integer), described in the section introduction.
For IP PrintWay basic mode,
the SMF6BYTD field is not present. |
56 |
38 |
|
16 |
|
Reserved |
72 |
48 |
SMF6URIL |
2 |
binary |
For IP PrintWay extended mode, the length of the
target device universal resource indicator (URI). For IP PrintWay basic mode, the SMF6URIL field
is not present. |
74 |
4A |
SMF6URI |
variable |
EBCDIC |
For IP PrintWay extended mode, the target device
universal resource indicator (URI). For IP PrintWay basic mode, the SMF6URI field is
not present. |
329 |
149 |
* |
3 |
|
Reserved |
332 |
14C |
SMF6ACTL |
2 |
binary |
For IP PrintWay extended mode, the length of the
accounting information in the SMF6ACCT field. If this field contains
0, there is no accounting information in SMF6ACCT. This situation
can occur if Print Interface or NetSpool dynamically allocated the
print job on the JES spool. For IP PrintWay basic
mode, this field is not present. |
334 |
14E |
SMF6ACCT |
143 |
EBCDIC |
For IP PrintWay extended mode, accounting information
from the JOB JCL statement. The first byte contains the number (in
binary) of accounting pairs that follow. Each accounting pair has
this format:- 1 byte with the length (in binary) of accounting information that
follows. If the length is zero, there is no string of accounting information
in this accounting pair.
- A variable length string that contains the accounting information
(in EBCDIC).
For example, if the JOB JCL statement contains:(TSS40000,JROMXB,1234,5,4321,,3,N,254)
The
SMF SMF6ACCT field contains:‘0908e3e2e2f4f0f0f0f006d1d9d6d4e7c204f1f2f3f401f5
04f4f3f2f10001f301d503f2f5f4’x
For IP PrintWay basic mode, this field is not present. |
477 |
1DD |
* |
3 |
|
Reserved |