z/OS MVS Programming: Assembler Services Reference ABE-HSP
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


DSPSERV—Execute form

z/OS MVS Programming: Assembler Services Reference ABE-HSP
SA23-1369-00

The execute form of the DSPSERV macro can refer to and modify the parameter list constructed by the list form of the macro.

Syntax

The execute form of the DSPSERV macro is written as follows:

Syntax Description
   
   name name: Symbol. Begin name in column 1.
   
One or more blanks must precede DSPSERV.
   
DSPSERV  
   
One or more blanks must follow DSPSERV.
   
  Valid parameters (Required parameters are underlined.)
CREATE STOKEN, NAME, TYPE, GENNAME, OUTNAME, BACK,
  BLOCKS, TTOKEN, ORIGIN, NUMBLKS
RELEASE STOKEN, START, BLOCKS, INLIST, RANGLIST, NUMRANGE
DELETE STOKEN
EXTEND STOKEN, BLOCKS, VAR, NUMBLKS
LOAD STOKEN, BLOCKS, START
OUT STOKEN, BLOCKS, START
   
,STOKEN=stoken-addr stoken-addr: RX-type address or register (2) - (12).
   
   ,TYPE=BASIC Default: TYPE=BASIC
   
   ,NAME=name-addr name-addr: RX-type address or register (2) - (12).
   
   ,GENNAME=NO Default: GENNAME=NO
   ,GENNAME=COND  
   ,GENNAME=YES  
   
   ,OUTNAME=outname-addr outname-addr: RX-type address or register (2) - (12).
   
   ,START=start-addr start-addr: RX-type address or register (2) - (12).
   
   ,BLOCKS=(max-addr,init-addr) max-addr: RX-type address or register (2) - (12).
   ,BLOCKS=(max,init) init-addr: RX-type address or register (2) - (12).
   ,BLOCKS=max max: Number up to 524288.
   ,BLOCKS=(0,init) init: Number up to 524288.
   ,BLOCKS=0 0 specifies the installation default size.
   ,BLOCKS=(0,init-addr) Default for CREATE: BLOCKS=0
   ,BLOCKS=(size-addr) size-addr: RX-type address or register (2) - (12)
   ,BLOCKS=(size) size: Number up to 524288.
   
   ,BACK=31 Default: BACK=31
   ,BACK=64  
   
   ,TTOKEN=ttoken-addr ttoken-addr: RX-type address or register (2) - (12).
   
   ,ORIGIN=origin-addr origin-addr: RX-type address or register (2) - (12).
   
   ,NUMBLKS=numblks-addr numblks-addr: RX-type address or register (2) - (12).
   
   ,INLIST=NO Default: INLIST=NO
   ,INLIST=YES  
   
   ,RANGLIST=rangelist-addr rangelist-addr: RS-type address or register (2) - (12). Required with INLIST=YES
   ,NUMRANGE=numrange-addr numrange-addr: RS-type address or register (2) - (12).
   ,NUMRANGE=1 Default: NUMRANGE=1
   
   ,VAR=NO Default: VAR=NO
   ,VAR=YES  
   
   ,PLISTVER=IMPLIED_VERSION  
   ,PLISTVER=MAX Default: IMPLIED_VERSION
   ,PLISTVER=plistver plistver: 0
   

,MF=(E,list addr)
,MF=(E,list addr,COMPLETE)

 
   

The parameters are explained under the standard form of the DSPSERV macro with the following exception:

,MF=(E,list addr)
,MF=(E,list addr,COMPLETE)
Specifies the execute form of the DSPSERV macro. list addr defines the area that the system uses for the parameter list. The system checks for required parameters and supplies optional parameters that are not specified.

COMPLETE specifies that the system is to check for required parameters and supply optional parameters that are not specified.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014