Use the ERRORLIMIT parameter in the EXAMINE command to suppress supportive and individual data set structural error messages during an EXAMINE run. This parameter indicates the number of these error messages to print. When EXAMINE reaches this number of errors, it stops issuing error messages but continues to scan the data set. ERRORLIMIT (0) means that none of these messages will be printed. When you do not specify the ERRORLIMIT parameter (the default condition), all supportive and individual data set structural error messages are printed. Note that the status and statistical messages, summary messages, and function-not-performed messages are not under the control of ERRORLIMIT, and print regardless of the ERRORLIMIT settings. The ERRORLIMIT parameter is used separately by INDEXTEST and DATATEST. For more information about using this parameter see z/OS DFSMS Access Method Services Commands.