DFS7412I ADJUSTED OTMA TPIPE COUNT FOR MEMBER member IS nnnnnnn (FETP=xxxxxxx, BETP=yyyyyyy, WGF=zz%).
Explanation
The DFS7412I message is an additional informational message that is issued after an OTMA member’s flood-related messages are issued, such as DFS4382W, DFS4383E, or DFS4384I. It shows the adjusted member tpipe count that is used for detecting the flood condition for the specified OTMA member.This message is issued only after the OTMA lightweight tpipe function is enabled by specifying LITETP=YES in the DFSYDTx member of the IMS.PROCLIB data set.
In the message text:
- member
- The OTMA client member.
- nnnnnnn
- The adjusted tpipe count that accounts for the less storage used by back-end tpipes.This value is calculated as follows:
- adjusted tpipe count = xxxxxxx + (yyyyyyy * zz)
- xxxxxxx
- The front-end tpipe count.
- yyyyyyy
- The back-end tpipe count.
- zz
- The percentage of the weighting factor in calculating the adjusted tpipe count for tpipe flood control.