PCI-X SAS RAID card comparison
This table compares the main features of PCI-X SAS RAID cards.
CCIN (custom card identification number) | 2BD9 | 2BE0 | 2BE1 | 572A | 572B | 572C | 572F / 575C | 57B8 |
---|---|---|---|---|---|---|---|---|
Description | PCI-X266 Planar 3 Gb SAS RAID Adapter (RAID/Cache Storage Controller) | PCI-X266 Planar 3 Gb SAS Adapter (RAID-10 Storage Controller) | PCI-X266 Planar 3 Gb SAS RAID Adapter (RAID/Cache Enablement) | PCI-X 266 Ext Dual-x4 3 Gb SAS Adapter | PCI-X 266 Ext Dual-x4 3 Gb SAS RAID Adapter | PCI-X 266 Planar 3 Gb SAS Adapter | PCI-X 266 Ext Tri-x4 3 Gb SAS RAID Adapter | PCI-X 266 Planar 3 Gb SAS RAID Adapter |
Form factor | Planar unique 64-bit PCI-X | Planar unique 64-bit PCI-X | Planar RAID enablement | Low profile 64-bit PCI-X | Long 64-bit PCI-X | Planar integrated | Long 64-bit PCI-X, double-wide card set | Planar RAID enablement |
Adapter failing function code LED value | 2D18 | 2D16 | 2D17 | 2515 | 2517 | 2502 | 2519 / 251D | 2505 |
Physical links | 6 (two 2x wide ports to shared SAS Drives and one 2x wide port to 2BE1 adapter) | 3 (Direct attach SAS Drives) | 8 (two 2x wide ports to shared SAS Drives, one 2x wide port to 2BD9 adapter, one phy to DVD, and optionally one physical link to Tape Drive) | 8 (two mini SAS 4x connectors) | 8 (two mini SAS 4x connectors) | 81 | 12 (bottom 3 mini SAS 4x connectors) and 2 (top mini SAS 4x connector for HA only) | 81 |
RAID levels supported | RAID 0, 5, 6, 10 | RAID 0, 54, 10 | RAID 0, 5, 6, 10 | RAID 0, 54, 64, 10 | RAID 0, 5, 6, 10 | RAID 0 | RAID 0, 5, 6, 10 | RAID 0, 5, 6, 10 |
Adding disks to an existing disk array supported RAID levels | RAID 5, 6 | RAID 5 | RAID 5, 6 | RAID 5, 6 | RAID 5, 6 | RAID 5, 6 | RAID 5, 6 | |
Write cache size | 175 MB | 175 MB | 175 MB | Up to 1.5 Gb (compressed) | 175 MB | |||
Read cache size | Up to 1.6 Gb (compressed) | |||||||
Cache battery pack technology | Lilon | Lilon | LiIon | LiIon | Not applicable2 | |||
Cache battery pack FFC | 2D1B | 2D1B | 2D03 | 2D065 | Not applicable2 | |||
Cache battery concurrent maintenance | No | No | No | No | No | No | Yes | Not applicable2 |
Cache data present LED | Yes | No | Yes | No | No | No | No | No |
Removable cache card | No | No | No | No | Yes | No | No | No |
Auxiliary write cache (AWC) support | No | No | No | No | No | No | Yes | Yes |
High availability (HA) two system RAID | Yes | No | Yes | Yes3 | Yes | No | No | No |
HA two system JBOD | No | No | No | Yes3 | No | No | No | No |
HA single system RAID | Yes | No | Yes | Yes3 | Yes | No | No | No |
Requires HA RAID configuration | Yes | No | Yes | No | Yes | No | No | No |
JBOD support | No | Yes | No | Yes | No | Yes | No | Yes |
|
Figure 1. CCIN 572A PCI-X266 External Dual-x4 3 Gb SAS adapter
Figure 2. CCIN 572B PCI-X266 Ext Dual-x4 3 Gb SAS RAID adapter
Figure 3. CCIN 572F PCI-X266 Ext Tri-x4 3 Gb SAS RAID adapter and
CCIN 575C PCI-X266 auxiliary cache adapter
Figure 4. CCIN 57B8 planar RAID enablement card
Figure 5. CCIN 2BE1 PCI-X266 Planar 3 Gb SAS Adapter
Figure 6. CCIN 2BE0 PCI-X266 Planar 3 Gb SAS Adapter
Figure 7. CCIN 2BD9 PCI-X266 Planar 3 Gb SAS RAID Adapter