Operator information messages
This topic defines the intervention and informational messages for Library, Media, Tape Drive, Library Manager, VTS/IBM® TS7700, and Controller used by an operator or storage administrator.
A TS7700 or VTS can also generate informational messages. These messages provide information about an operation that is taking place within the machine that may or may not require operator action. Informational messages are always sent to the attached hosts. If the TS7700 generating the message is a member of a grid, the message is sent to all hosts attached to all TS7700s in the grid configuration. If the VTS is a member of a Peer-to-Peer (PTP) VTS, the message is sent to all hosts attached to the Virtual Tape Controllers of that PTP VTS.
CBR3750I Message from library library-name: message-text
Where: - library-name identifies the source of the message. Messages can come from a native library partition, stand-alone VTS or the composite or distributed libraries in a TS7700 or a PTP VTS. This is the eight-character library name that had been previously defined on library definitions panels through z/OS.
- message-text contains the information being provided. Included in the message-text is a five-character message ID field that may be examined by message automation software to filter or route specific messages. The message-text can be up to 240 characters in length.
Impact | Code | Impact Description | Action |
---|---|---|---|
Critical | C | Operations in the reporting TS7700/VTS/Library are stopped, all jobs allocated may fail. | Immediate operator, system administrator or service representative action. |
Serious | S | One or more jobs may fail, some virtual volumes may be inaccessible, mounts are suspended, performance may be degraded. | Important to examine message, take action as needed. |
Impact | I | No immediate impact to operations, but ejects cannot proceed, input station processing problem, early warning for serious type interventions including performance degradation, copies may not be performed or are degraded. | Examine message as time allows. |
Warning | W | No immediate impact to operations, redundant resource lost, installation/configuration problem or change, drive cleaning may be impacted. | Examine message as time allows. |
Information | M | Informational message about operations in the TS7700/VTS/library. | Log for historical review. |
- Library - regarding the physical library
- Media - regarding a physical tape cartridge
- Tape Drive - regarding a physical tape device
- Library Manager - regarding the library manager code and hardware
- VTS/TS7700 - regarding the VTS or TS7700 code and hardware
- Controller - regarding the controller code or hardware
- m
- n
- x
- y
- z
Message ID | Impact Code | Product Area | Intervention Message Text |
---|---|---|---|
None | M | VTS/TS7700 | Temporary Conflict for Volser xxxxxx - LM paused or long drive op |
None | M | VTS/TS7700 | ERROR - Drive types in VTS are mixed or cannot ID drives |
None | M | VTS/TS7700 | Checkfiles created on virgin VTS system |
None | M | VTS/TS7700 | VTS Database Backup written to Physical Tape RSG632. |
AL0000 | M | VTS/TS7700 | Uncopied data of xxxx GB above low warning limit of yyyy GB |
AL0001 | M | VTS/TS7700 | No longer above uncopied data low warning limit of yyyy GB |
AL0002 | M | VTS/TS7700 | Available virtual scratch volumes of nnn below low limit of xxxxx for category yyyy |
AL0003 | M | VTS/TS7700 | Available virtual scratch volumes no longer below low limit of xxxxx for category yyyy |
AL0004 | M | VTS/TS7700 | Available physical drives of nn is below low limit of xx |
AL0005 | M | VTS/TS7700 | Available physical drives no longer below low limit of xx |
AL0006 | M | VTS/TS7700 | Available physical scratch volumes nnn below low limit of xxx for pool yy |
AL0007 | M | VTS/TS7700 | Available physical scratch no longer below low limit of xxx for pool yy |
AL0008 | M | VTS/TS7700 | Resident data of nnnn GB above low warning limit of xxxx GB |
AL0009 | M | VTS/TS7700 | No longer above resident data low warning limit of xxxx GB |
AL0010 | M | TS7700 | Distributed Library xx has a total pending inbound copy backlog of yyyy GB, which is above the low warning limit of zzzz GB |
AL0011 | M | TS7700 | Distributed Library xx has successfully fallen below the inbound copy backlog low warning limit of zzzz GB |
AL2000 | M | VTS/TS7700 | Database Backup written to Encrypted Physical Tape vvvvvv |
AL2001 | M | VTS/TS7700 | No Encryption Key Server is available for encryption key exchanges. |
AL3000 | M | VTS/TS7700 | The TS7700 has restored communication with the primary Encryption Key Server. |
AL3001 | VTS/TS7700 | The TS7700 has restored communication with the alternate Encryption Key Server. | |
AL5000 | M | VTS/TS7700 | Uncopied data of nnnn GB above high warning limit of xxxx GB |
AL5001 | M | VTS/TS7700 | No longer above uncopied data high warning limit of xxxx GB |
AL5002 | M | VTS/TS7700 | Available virtual scratch volumes of nnn below critical limit of xxxxx for category yyyy |
AL5003 | M | VTS/TS7700 | Available virtual scratch volumes no longer below critical limit of xxxxx for category yyyy |
AL5004 | M | VTS/TS7700 | Available physical drives of nnn is below critical limit of xxx |
AL5005 | M | VTS/TS7700 | Available physical drives no longer below critical limit of xxx |
AL5006 | M | VTS/TS7700 | Available physical scratch volumes nnn below critical limit of xxx for pool yy |
AL5007 | M | VTS/TS7700 | Available physical scratch no longer below critical limit of xxx for pool yy |
AL5008 | M | VTS/TS7700 | Resident data of xxxx GB above high warning limit of yyyy GB |
AL5009 | M | VTS/TS7700 | No longer above resident data high warning limit of yyyy GB |
AL5010 | M | TS7700 | Distributed Library xx has a total pending inbound copy backlog of yyyy GB, which is above the critical warning limit of zzzz GB |
AL5011 | M | TS7700 | Distributed Library xx has successfully fallen below the inbound copy backlog critical warning limit of zzzz GB |
AL5012 | M | TS7700 | Auto removal of volumes has completed on this disk-only cluster |
AL5013 | M | TS7700 | Physcial volume xxxxxx from cluster name or library id has been erased |
AL5014 | M | TS7700 | BVIR volume map exceeds record maximum records |
G0001 | M | VTS/TS7700 | Service preparation has started for distributed library xx. |
G0002 | M | VTS/TS7700 | Service preparation has completed for distributed library xx. |
G0003 | W | VTS/TS7700 | Service preparation has failed for distributed library xx. |
G0004 | M | VTS/TS7700 | Service preparation has exited for distributed library xx. |
G0005 | I | VTS/TS7700 | Distributed library xx has entered the immediate deferred state. |
G0006 | M | VTS/TS7700 | Distributed library xx has exited the immediate deferred state. |
G0007 | W | VTS/TS7700 | A user at library xx has enabled Read/Write takeover against library yy. |
G0008 | W | VTS/TS7700 | A user at library xx has enabled Read-Only takeover against library yy. |
G0009 | S | VTS/TS7700 | Autonomic ownership takeover manager within library xx has determined that library yy is unavailable. The Read/Write ownership takeover mode has been enabled. |
G0010 | S | VTS/TS7700 | Autonomic ownership takeover manager within library xx has determined that library yy is unavailable. The Read-Only ownership takeover mode has been enabled. |
G0011 | M | VTS/TS7700 | Ownership takeover mode within library xx has been automatically disabled now that library yy has become available. |
G0012 | W | VTS/TS7700 | A user at library xx has disabled the ownership takeover mode within the grid against library yy. |
G0013 | S | VTS/TS7700 | Library xx has experienced an unexpected outage with its peer library yy. Library yy may be unavailable or a communication issue may be present. |
G0014 | M | VTS/TS7700 | Library xx is now available to the peer library yy. |
G0015 | M | VTS/TS7700 | Library xx has restored communication and is now available to the peer library yy. |
G0020 | M | VTS/TS7700 | Library xx has taken over ownership of volume yyyyyy from library zz using a read/write takeover mode. mmmmmm total volumes have been taken over from peer clusters. |
G0021 | M | VTS/TS7700 | Library xx has taken over ownership of volume yyyyyy from library zz using a read-only takeover mode. mmmmmm total volumes have been taken over from peer clusters. |
G0022 | M | VTS/TS7700 | Library xx has reconciled volume yyyyyy against library zz with respect to ownership takeover. mmmmmm total volumes remain in the takeover state against one or more peer libraries. |
G0023 | S | VTS/TS7700 | Library xx has moved volume yyyyyy into the damaged state due to ownership takeover conflict. mmmmmm total volumes now exist in the damaged state. |
G0024 | S | VTS/TS7700 | Library xx has moved volume yyyyyy into the damaged state due to token corruption. mmmmmm total volumes now exist in the damaged state. |
G0025 | S | VTS/TS7700 | Library xx has moved volume yyyyyy into the damaged state due to disaster recovery. mmmmmm total volumes now exist in the damaged state. |
G0026 | S | VTS/TS7700 | Library xx has moved volume yyyyyy into the damaged state. mmmmmm total volumes now exist in the damaged state. |
G0027 | M | VTS/TS7700 | Library xx has moved volume yyyyyy out of the damaged state and into the insert category. mmmmmm total volumes remain in the damaged state. |
G0030 | I | VTS/TS7700 | Library xx Primary, Alternate, Primary2, and Alternate2 grid links are degraded. The degraded grid link port is reported. |
G0031 | M | VTS/TS7700 | All grid links for this cluster have left the degraded state. |
G0032 | I | TS7700 | XX copies have been queued for over 24 hours. Check Incoming Copy Queue on the management interface for details. |
G0033 | M | VTS/TS7700 | Distributed Library xx has entered the synchronous deferred state due to VOLSER yyyyyy. |
G0034 | M | VTS/TS7700 | Distributed Library xx has exited the synchronous deferred state. |
G0035 | M | VTS/TS7700 | Distributed Library xxxx mount failed due to excessive large volume mounts. |
OP0001 | S | Library | The convenience I/O station should be empty but is not. Visually check the station. |
OP0002 | S | Library | A cartridge has been dropped. |
OP0003 | I | Library | * The Convenience I/O station is full. |
OP0004 | I | Library | * The virtual library is full. |
OP0005 | S | Media | A duplicate VOLSER (xxxxxx) was ejected to the convenience I/O station. |
OP0006 | I | Media | A duplicate VOLSER (xxxxxx) was left in the convenience I/O station. |
OP0007 | I | Media | A VOLSER (xxxxxx) with an unknown media type has been ejected to the convenience I/O station. |
OP0008 | W | Media | * The library is out of CST/ECCST cleaner cartridges. |
OP0009 | I | Media | An invalid VOLSER (xxxxxx) has been ejected to the convenience I/O station. |
OP0010 | I | Library | *During an inventory update operation, a VOLSER (xxxxxx) was ejected to the convenience I/O station because there were no free cells. |
OP0011 | I | Media | An error occurred for cartridge xxxxxx during
insert from convenience I/O slot number yy to cell: Rack number: nn |
OP0012 | I | Media | An unreadable VOLSER was left in high-capacity input rack cell yyyy. |
OP0013 | I | Media | The cartridge label located at cell (rack number: nn, rack column: mm, rack row: zz) has an unknown media type. |
OP0014 | I | Media | An invalid VOLSER (xxxxxx) was left in the convenience I/O station. |
OP0015 | I | Media | The cartridge label located at cell (rack number: nn, rack column: mm, rack row: zz) is unreadable. |
OP0016 | I | Media | The cartridge label located at cell (rack number: nn, rack column: mm, rack row: zz) is invalid. |
OP0017 | S | Tape Library | A load or unload failure on device nnnn. |
OP0018 | I | Media | Target Storage Pool nn is out of physical volumes. |
OP0019 | I | Media | VOLSER xxxxxx is damaged. |
OP0020 | I | Library | * The convenience I/O station door is open. |
OP0021 | I | Library | * The convenience I/O station door is open. |
OP0022 | S | Media | Unknown intervention for condition xxxxxx. |
OP0023 | S | Media | VOLSER (xxxxxx) could not be put away. It was ejected to high-capacity output rack cell: yyyy. |
OP0024 | I | Library | A duplicate VOLSER has been found at cell nnn. |
OP0025 | S | Library | A duplicate VOLSER has been found at cell nnn. |
OP0026 | S | Library | A cartridge has been dropped. |
OP0027 | S | Library | Pool nn is defined with a different media class and was reset to match. |
OP0028 | C,S Note 1 | Library | An emergency stop has occurred. |
OP0029 | S | Media | Damaged VOLSER (xxxxxx) ejected to the convenience I/O station. |
OP0030 | S | Media | Cartridge (xxxxxx) has been left in uninstalled device. |
OP0031 | I | Tape Drive | Device xxx is not ready. |
OP0032 | I | Tape Drive | Device xxx is reporting an element address of zero. Call service. |
OP0033 | I | Library | High capacity input station should be empty but is not. |
OP0034 | I | Media | A mislabeled cleaner cartridge has been left in device xxx feed slot. Remove the cartridge. |
OP0035 | W | Tape Drive | A recoverable error occurred on device xxx. A service call may be needed if the error persists. |
OP0036 | W | Media | A cartridge containing invalid media has been left in device xxx feed slot. Remove the cartridge. |
OP0037 | W | Media | An invalid media VOLSER <xxxxxx> has been ejected to the convenience I/O station. |
OP0038 | S | Media | A cartridge or cartridge label located at cell x y zz is upside-down. |
OP0039 | S | Media | A duplicate VOLSER has been found at cell yyyy. |
OP0040 | S | Media | The cartridge label located at cell yyyy is unreadable. |
OP0041 | S | Media | The cartridge label located at cell yyyy is invalid. |
OP0042 | C,S Note 1 | Library | The system has failed. A service call is required. |
OP0043 | C | Library | * The accessor or gripper configuration has changed. The 3494 must be retaught. |
OP0044 | I | Library | * The top two I/O station cells are inaccessible. Move cartridges to cell 3. |
OP0045 | S | Library | VOLSER xxxxxx cannot be removed from its home location. |
OP0046 | I | Library | VOLSER (xxxxxx) cannot be removed from the high-capacity station cell: yyyy. |
OP0047 | I | Tape Drive | The device xxxxxx has failed and a service call is required to correct the problem. |
OP0048 | I | Media | A VOLSER xxxxxx has an incorrect media on the external label. |
OP0049 | S | Media | A physical device's install status or online status has changed for a device attached to the TS7700. |
OP0050 | S | Media | Control of this physical device has been switched to the node on this cluster (the cluster where the operator intervention is listed). |
OP0051 | W | Media | * The library is out of HPCT cleaner cartridges. |
OP0052 | S | Media | A VOLSER (xxxxxx) with an unknown media type has been ejected to the convenience I/O station. |
OP0053 | S | Media | A VOLSER (xxxxxx) with an unknown media type has been ejected to high-capacity output facility cell: yyyy. |
OP0054 | I | Media | VOLSER (xxxxxx) cannot be removed from convenience I/O station. |
OP0055 | I | VTS/TS7700 | Free storage threshold has been crossed for VTS z. |
OP0056 | I | Media | A VOLSER (xxxxxx) with an unknown media type has been left in the convenience input station. |
OP0057 | I | Media | A VOLSER (xxxxxx) with an unknown media type has been left in the high-capacity input station. |
OP0058 | S | Media | An invalid VOLSER (xxxxxx) has been ejected to the convenience I/O station. |
OP0059 | S | Media | The cartridge label located at cell yyyy has an unknown media type. |
OP0060 | S | Media | During an Inventory Update operation, VOLSER xxxxxx was ejected to the convenience I/O station because there were no free cells. |
OP0061 | S | Media | During an Inventory Update operation, VOLSER xxxxxx was ejected to the high capacity station because there were no free cells. |
OP0062 | C,I Note 1 | Library | Power failure on accessor x. A service call is required. |
OP0063 | W | TS7700 | Limited cache free space. |
OP0064 | W | Library Manager | Dual Write has failed. A service call is required. |
OP0065 | I | TS7700 | Out of cache resources. |
OP0066 | M | VTS/TS7700 | *One or more volumes have been inserted into the library and marked unassigned. |
OP0067 | I | Media | Eject failed for VOLSER xxxxxx. This operation was initiated by the Library Manager. |
OP0068 | M | Library Manager | A Library Manager switch has completed. This switch was initiated by the operator. |
OP0069 | W | Library Manager | A Library Manager switch has completed. This switch was due to an error. |
OP0070 | W | Library Manager | A hard drive has failed. Call service. |
OP0071 | W | Library Manager | Mirroring disabled. Call service. Library is operational but degraded. Or LM-x mirroring disabled. Call service. Library is operational but degraded. |
OP0072 | C | Library | Barrier door A is not fully retracted. Call service. |
OP0073 | C | Library | Barrier door B is not fully retracted. Call service. |
OP0074 | S | Library Manager | Controller on port xx requires a higher level of Library Manager. |
OP0075 | I | Library Manager | Database discrepancies have been found. Call service. Library is still operational. |
OP0076 | S | Media | VOLSER xxxxxx cannot be found. Check home cell: yyyy and accessor A, gripper 1. |
OP0077 | S | Media | VOLSER xxxxxx cannot be found. Check home cell: yyyy and accessor A, gripper 2. |
OP0078 | S | Media | VOLSER xxxxxx cannot be found. Check home cell: yyyy and accessor B, gripper 1. |
OP0079 | S | Media | VOLSER xxxxxx cannot be found. Check home cell: yyyy and accessor B, gripper 2. |
OP0080 | W | Library | Error writing to dual write log (on Library Manager A or B). |
OP0081 | C | Library | An emergency stop has occurred, or accessor A or B has failed. A service call is required. |
OP0082 | I | Media | VOLSER xxxxxx left in convenience I/O slot nn due to vision system failure. |
OP0083 | I | Media | VOLSER xxxxxx left in high capacity rack cell xx y zz due to vision system failure. |
OP0084 | W | Library Manager | Scratch mount performance is degraded. A service call is required. |
OP0085 | W | Library Manager | Database performance is degraded. |
OP0086 | W | Library Manager | Problem detected with Token Ring connection. Call service. |
OP0087 | W | Library Manager | Logging is now disabled on LM-x. Call service. |
OP0088 | S | VTS/TS7700 | Target Storage Pool xx is out of stacked volumes for VTS y. |
OP0089 | W | VTS/TS7700 | The number of xxxxxxxx constructs has reached the maximum number allowed (yyy). |
OP0090 | W | Library Manager | The number of xxxxxxxx constructs has exceeded yyy. The maximum number allowed is zzz. |
OP0091 | S | Library Manager | The yyyyy internal LAN switch (HUB) has failed or is not configured correctly. Call service. |
OP0092 | S | Library Manager | A database error has occurred. View help panel for SQL error code xxxx. Call service. |
OP0093 | W | Library Manager | NVRAM read failure on LM-A. Call service. |
OP0094 | W | Library Manager | NVRAM write failure on LM-A. Call service. |
OP0095 | W | Library Manager | NVRAM read failure on LM-B. Call service. |
OP0096 | W | Library Manager | NVRAM write failure on LM-B. Call service. |
OP0098 | S | Library Manager | The yyyyy internal LAN switch (HUB) is not configured correctly. Call service. |
OP0099 | M | VTS/TS7700 | VOLSER xxxxxx was ejected during recovery processing. |
OP0100 | W | VTS/TS7700 | A read-only status physical volume xxxxxx has been ejected. |
OP0101 | C | VTS/TS7700 | * This cluster is out of empty physical volumes. |
OP0102 | S | VTS/TS7700 | A physical volume has a label error. Internal: xxxxxx, External: yyyyyy. |
OP0103 | C | VTS/TS7700 | A permanent, nonrecoverable tape volume cache error has occurred. (VTS z) |
OP0104 | S | VTS/TS7700 | An orphaned virtual volume (xxxxxx) has been found. Call service. |
OP0105 | S | VTS/TS7700 | A VTS has a CHECK-1 (xxxx) failure. (VTS z) |
OP0106 | S | VTS/TS7700 | Virtual volume xxxxxx was only partially read. |
OP0107 | S | VTS/TS7700 | Virtual volume xxxxxx was not fully recovered from damaged physical volume yyyyyy. |
OP0108 | W | VTS/TS7700 | The Tape Volume Cache is degraded (xxxx). (VTS z) |
OP0109 | W | VTS/TS7700 | Database restore from volume xxxxxx failed, attempting restore from next most recent. (VTS z) |
OP0110 | S | VTS/TS7700 | Insert of virtual volume xxxxxx failed during disaster recovery. (VTS z) |
OP0111 | S | VTS/TS7700 | Damaged volume xxxxxx ejected during disaster recovery. Could not be read on 2 drives. (VTS z) |
OP0112 | W | VTS/TS7700 | Device serial number nnnnn has been made offline and/or unavailable by the TS7700 with a reason code of mmmm. |
OP0113 | C | VTS/TS7700 | A VTS does not have enough available physical drives (359x) to continue operation. (VTS z) |
OP0114 | S | VTS/TS7700 | The grid partition attempted unsuccessfully to eject a stacked volume (xxxxxx) during disaster recovery. (VTS z) |
OP0115 | S | VTS/TS7700 | The cluster attempted unsuccessfully to eject a damaged physical volume xxxxxx. |
OP0116 | S | VTS/TS7700 | VTS physical device xxx is cabled incorrectly. It has been made unavailable. (VTS z) |
OP0117 | W | VTS/TS7700 | The TS7700 cannot communicate with device xxx. It has been made unavailable. (VTS z) |
OP0118 | S | VTS/TS7700 | Mount of virtual volume xxxxxx failed because physical volume yyyyyy is not in the library. (rc=rrrr) (VTS z) |
OP0119 | Database restore from volume <xxxxxx> failed. Attempting to restore from next most recent event. | ||
OP0120 | S | VTS/TS7700 | Mount of virtual volume xxxxxx failed because physical volume yyyyyy is misplaced. (reason code=nnn) |
OP0121 | S | VTS/TS7700 | Mount of virtual volume xxxxxx failed because physical volume yyyyyy is inaccessible. |
OP0122 | S | VTS/TS7700 | Mount of virtual volume xxxxxx located on physical volume yyyyyy failed. (reason code=mmm) |
OP0123 | W | VTS/TS7700 | Physical volume xxxxxx is in read-only status due to successive media errors. |
OP0124 | S | VTS/TS7700 | Physical volume xxxxxx is unavailable. |
OP0125 | W | VTS/TS7700 | TS7700 controller degraded. Error code yyyyy. Call service. (VTS z) |
OP0126 | W | VTS/TS7700 | TS7700 requested that device xxx be made unavailable but a mount/demount is in progress. (VTS z). |
OP0127 | C | VTS/TS7700 | An invalid mixture of physical drive types was detected. |
OP0128 | C | VTS/TS7700 | *The TS7700 does not have enough physical drives to continue operation. (VTS z). |
OP0130 | W | VTS/TS7700 | Physical volume xxxxxx failed scratch mount. Its label cannot be read and the tape must be re-initialized. |
OP0131 | I | VTS/TS7700 | Stacked volume xxxxxx ejected due to incompatible media type. (VTS z). |
OP0132 | W | VTS/TS7700 | Stacked volume xxxxxx could not be ejected because the convenience I/O station is full, or the door is open. |
OP0134 | M | VTS/TS7700 | Physical volume xxxxxx is write-protected. |
OP0135 | W | VTS/TS7700 | The TS7700 unsuccessfully attempted to eject write-protected physical volume xxxxxx. |
OP0136 | W | VTS/TS7700 | Physical volume xxxxxx moved to category FF08 due to unrecovered active data. |
OP0138 | C | VTS/TS7700 | The common scratch pool (Pool 00) is out of mmmm media physical volumes. |
OP0139 | C | VTS/TS7700 | Storage pool nn is out of scratch physical volumes. |
OP0140 | W | VTS/TS7700 | VOLSER xxxxxx could not be moved from Storage Pool nn to Storage Pool mm. Error code = yyyy. |
OP0141 | I | VTS/TS7700 | VTS x was unable to obtain construct information for VOLSER xxxxxx. |
OP0142 | S | VTS/TS7700 | Stacked volume xxxxxx exists in the VTS database but doesn't exist in the Library Manager database. |
OP0143 | M | VTS/TS7700 | VTS x has completed processing the stacked volumes as part of the Disaster Recovery inventory. |
OP0144 | W | VTS/TS7700 | Eject failed on physical volume xxxxxx that contains active data. Error code = nnnn. |
OP0145 | W | VTS/TS7700 | Unable to make stacked volume xxxxxx read-only. |
OP0146 | W | VTS/TS7700 | Unable to make stacked volume xxxxxx read-write. |
OP0147 | W | VTS/TS7700 | Stacked volume xxxxxx is in an invalid state. |
OP0148 | S | VTS/TS7700 | There are stacked volumes in the VTS database that can't be found in the library. |
OP0149 | C | TS7700 | Storage pool nn is out of write compatible physical scratch volumes. |
OP0150 | I | TS7700 | The physical volume xxxxxx has become degraded. This condition is the result of a media condition report. |
OP0151 | W | VTS/TS7700 | The time on the TS7700 could not be adjusted. Contact your IBM service representative. |
OP0152 | S | VTS/TS7700 | Active data on ejected physical volume xxxxxx need to be recovered. |
OP0153 | S | VTS/TS7700 | Physical volume xxxxxx is misplaced. |
OP0154 | I | VTS/TS7700 | Pool nn has stacked volumes of wrong (opposite) media class. (VTS z). |
OP0155 | I | TS7700 | Device nnnn is configured incorrectly. 3592-E05 must be set to emulate a 3592-J1A. |
OP0160 | S | VTS/TS7700 | Above threshold for uncopied data in cache, throttling possible (VTS z). |
OP0161 | M | VTS/TS7700 | Below threshold for uncopied data in cache (VTS z). |
OP0164 | M | TS7700 | Auto removal of volumes has begun on this disk-only cluster. |
OP0165 | M | TS7700 | One or more non-writable physical volumes were found. |
OP0166 | M | TS7700 | Copy export did not export physical volume xxxxxx because of an incorrect format. |
OP0167 | M | TS7700 | Unsupported media (for example: JA, JJ) is set for First Media and /or Second Media for Physical Volume Pools(s): xx. |
OP0168 | I | TS7700 | One or more unsupported empty media has been found and cannot be used by the installed tape drives. |
OP0169 | C | TS7700 | The cache type is out of cache resources. The total used, space usage TiB, is greater than 95% of the total cache space, total space TiB. |
OP0170 | W | TS7700 | The cache type has limited cache free space. The total used, space usage TiB, is approaching 95% of the total cache space, total space TiB. |
OP0200 | W | TS7700 | The local cluster is operating in immediate copy mode and at least one copy did not finish prior to the completion of the Rewind/Unload command. |
OP0201 | I | TS7700 | All immediate deferred copy operations are complete. |
OP0202 | W | TS7700 | One or more volumes opened as part of a synchronous mode copy operation did not synchronize completely across both clusters. |
OP0203 | I | TS7700 | Synchronization across both clusters has completed for all volumes that were in the synchronous deferred state. |
OP0204 | W | TS7700 | Copy operations for the local cluster are disabled by the system. |
OP0205 | I | TS7700 | The system has enabled copy operations at the local cluster. |
OP0206 | I | TS7700 | Copy operations for the local cluster are disabled by the host. |
OP0207 | I | TS7700 | Copy operations for the local cluster are enabled by the host. |
OP0300 | I | VTS/TS7700 | One or more virtual volumes have corrupted tokens. Call service. |
OP0301 | S | VTS/TS7700 | Previous Peer-to-Peer Virtual Volume Restore did not complete. Call service. (VTS z). |
OP0302 | W | VTS/TS7700 | VOLSER xxxxxx is damaged. (VTS z). |
OP0303 | S | VTS/TS7700 | VOLSER xxxxxx is in the manual eject category. (VTS z). |
OP0304 | S | VTS/TS7700 | VTS ADSM port xx has failed. Call service. (VTS z). |
OP0305 | W | VTS/TS7700 | More than nn errors encountered for stacked volume xxxxxx. (VTS z). |
OP0306 | W | VTS/TS7700 | Pool nn has stacked volumes of different media class and was reset to default values. (VTS z). |
OP0307 | I | VTS/TS7700 | VTS attempted High Capacity Cache Option with xxxxx volumes but yyyyy volumes already exist. (VTS z). |
OP0308 | C | VTS/TS7700 | A TS7700 has been taught/configured incorrectly as a cluster. |
OP0309 | C | VTS/TS7700 | Cluster has been taught/configured incorrectly as a TS7700. |
OP0310 | I | TS7700 | The data class nnnn was automatically created with the default actions for volume virtual volume xxxxxx |
OP0311 | I | TS7700 | The Storage Class nnnn was automatically created with the default actions for volume xxxxxx. |
OP0312 | I | TS7700 | The Management Class nnnn was automatically created with the default actions for volume xxxxxx. |
OP0313 | I | TS7700 | The Storage Group nnnn was automatically created with the default actions for volume xxxxxx. |
OP0314 | I | TS7700 | The inhibit create command was ignored and one or more constructs were automatically created with the default actions for volume xxxxxx as a result of an imbalance of defined SMS constructs across the Domain |
OP0315 | I | TS7700 | The maximum number of defined constructs has been reached. An imbalance of defined SMS constructs across the domain has occurred. Default constructs were assigned for volume xxxxxx. |
OP0316 | C | TS7700 | The TS7700 has detected corrupted tokens for one or more virtual volumes. |
OP0400 | W | Media | * The library is out of ETC cleaner cartridges. |
OP0401 | M | Media | * xxxxx cleaner cartridge (yyyyyy) was ejected due to maximum use. |
OP0402 | W | Library | xx percent of mounts performed by accessor y over the past hour required excessive mount recovery. Call service. |
OP0403 | W | Library | xx percent of mounts performed by accessor y over the past 24 hours required excessive mount recovery. Call service. |
OP0404 | W | Library | Device zzz required excessive mount recovery (xx percent of mounts) over the past hour (accessor y). Call service. |
OP0405 | W | Library | Device zzz required excessive mount recovery (xx percent of mounts) over the past 24 hours (accessor y). Call service. |
OP0406 | W | Library Manager | Logging is degraded on LM-x. Call service. |
OP0407 | W | Library Manager | Communication with the MasterConsole has failed (LM rc = xx, MasterConsole rc = yy). Call service. |
OP0408 | W | Library Manager | LM-x: MasterConsole configuration has failed (rc = yy). Call service. |
OP0409 | M | TS7700 | The volume hold function was disabled for fast-ready category xxxx. |
OP0410 | M | TS7700 | The hold/expire time has been changed to nnn hours for fast-ready category xxxx. |
OP0411 | M | TS7700 | A fast-ready attribute was deleted for category xxxx. |
OP0412 | W | Media | VOLSER (xxxxxx) has been returned to the station. A service cartridge cannot be inserted via CIO or HCIO. |
OP0413 | W | Library Manager | Possible hard drive failure detected. View help panel for error code = yy. |
OP0414 | I | Library | Error threshold exceeded for accessor x. View help panel for error code = yy. |
OP0415 | S | VTS/TS7700 | During an insert/inventory the media type of VOLSER xxxxxx did not match its destination pool. VOLSER is not assigned to a VTS. |
OP0416 | W | Library | Preferred EASH in frame xx is not responding. Call service. |
OP0417 | W | Library | Non-preferred EASH in frame xx is not responding. Call service. |
OP0418 | W | Library | Port xx on the preferred EASH in frame yy has failed. Call service. |
OP0419 | W | Library | Port xx on the non-preferred EASH in frame yy has failed. Call service. |
OP0420 | W | Library | Library Serial Number xxxxxxx from CU/VTS on port yy does not match the number entered during Configuration. |
OP0421 | W | Library | Library First Storage Element xxxx from CU/VTS on port yy does not match the element entered during Configuration. |
OP0422 | W | Library | Device xxx with World Wide Node Name yy..yy is cabled incorrectly. It is in the wrong virtual or physical library. |
OP0423 | W | Media | A VOLSER (xxxxxx) with an unsupported media type has been left in the convenience input station. |
OP0424 | I | Media | An unreadable VOLSER was left in the convenience I/O station, element address xxxx. |
OP0425 | W | Tape Drive | Two devices (xxx, yyy) have the same serial number (zzzzzzz). Both have been uninstalled. Call service. |
OP0426 | W | Tape Drive | Two devices (xxx, yyy) have the same element addr (zzzz). Both have been uninstalled. Call service. |
OP0427 | W | Library | The 3584 library reported that calibration is required. |
OP0428 | S | Library | The 3584 reported a hardware error (nnnn) . Contact your IBM service representative. |
OP0430 | W | Library Manager | The Primary Link has encountered multiple failures. Call service. |
OP0431 | M | Reserved | |
OP0432 | M | Reserved | |
OP0433 | W | Library Manager/TS7700 | The Send Interventions to Host Console settings on the Events panel has been turned on. |
OP0434 | W | Library Manager/TS7700 | The Send Interventions to Host Console settings on the Events panel has been turned off. |
OP0435 | S | Tape Drive | Two devices (xxx;yyy) have the same serial number (zzzzzzz). Second has been uninstalled. Call service. |
OP0436 | W | Tape Drive | Two devices (xxx;yyy) have the same element address (zzzz). Second has been uninstalled. Call service. |
OP0437 | S | Tape Drive | Cartridge xxxxxx has been left in uninstalled device yyy. Call service. |
OP0438 | W | Tape Drive | Device yyy is reporting an element address of zero. Call service. |
OP0439 | W,S See note 2 | TS7700 | The virtual tape library has lost communication with the primary Encryption Key Server. |
OP0440 | W,S See note 2 | TS7700 | The virtual tape library has lost communication with the alternate Encryption Key Server. |
OP0441 | M | Library | Possible degradation due to 3584 TapeAlert error (nnnn). Service call Home has been generated. |
OP0442 | W | Media | Physical volume xxxxxx is inaccessible. |
OP0443 | W | VTS/TS7700 | The virtual tape library has detected an inconsistency with the TS3500. |
OP0444 | W | Tape Drive | LM PC has not been rebooted in 6 months |
OP0445 | W | TS7700 | The primary Encryption Key Server was set to UNAVAILABLE |
OP0446 | W | TS7700 | The alternate Encryption Key Server was set to UNAVAILABLE |
OP0448 | M | Media | More than nn errors were encountered for physical volume xxxxxx. |
OP0449 | M | VTS/TS7700 | Pool nn has physical volumes of the wrong media class. |
OP0450 | M | VTS/TS7700 | The media type of VOLSER xxxxxx does not match its VOLSER range. The VOLSER was not assigned to a cluster. |
OP0451 | M | VTS/TS7700 | Encryption is enabled. No Encryption Key Server are configured. |
OP0452 | W | VTS/TS7700 | Device nnn could not encrypt data in storage pool nn (Encryption Key Server error mmm). |
OP0453 | W | VTS/TS7700 | Device nnnn could not append encrypted data to cartridge xxxxxx (Encryption Key Server error mmm). |
OP0454 | W | VTS/TS7700 | Device nnnn could not decrypt data from cartridge xxxxxx (Encryption Key Server error mmm). |
OP0455 | W | Tape Drive | Device nnnnn is not in 3592 E05 Native mode. The Device was made unavailable. |
OP0456 | W | VTS/TS7700 | Encryption is enabled on the virtual tape library. Device nnnnn is not enabled for System Managed Encryption. The encryption capability of the TS7700 is not affected by this configuration, but for efficiency it is recommended that the drive be permanently set to System Managed Encryption using the Tape Library Management GUI. |
OP0457 | W | Tape Drive | Device nnnnn is not in 3592 J1A emulation mode. The device was made unavailable. |
OP0458 | S | TS7700 | An internal hardware/software error has occurred. |
OP0459 | S | TS7700 | A disk cache error has occurred. |
OP0460 | W | TS7700 | A Grid link error xxxxxx has occurred. |
OP0461 | I | Tape Drive | A tape drive error: xxxxxx has occurred. |
OP0462 | I | TS7700 | A fibre switch error xxxxxx has occurred. |
OP0463 | W | VTS/TS7700 | A TSSC error has occurred. The TSSC is unable to call home. |
OP0464 | I | Library | A library error has occurred. |
OP0465 | I | VTS/TS7700 | An Autonomic Ownership Takeover Mode communications error occurred. The device is unable to communicate with the remote cluster. |
OP0466 | I | VTS/TS7700 | An encryption key server error xxxxxx error has occurred. |
OP0467 | I | Media | Tape cartridge xxxxxx is stuck in a storage cell. |
OP0468 | W | Library Manager | The 3494 Library Manager has an Event. |
OP0469 | W | Library Manager | The 3494 Library Manager is in a degraded state. |
OP0470 | M | TS7700 | Delete Expire capability has been disabled. |
OP0471 | I | TS7700 | The Field Microcode Replacement tape xxxxxx cannot be used as a data cartridge. |
OP0472 | M | TS7700 | The database backup to physical volume xxxxxx failed during the Copy Export operation as a result of a media error. |
OP0473 | M | TS7700 | A media error occurred during the Copy Export operation and the physical volume xxxxxx has been ejected. The medium may be degraded, and should not be reused in an export pool. |
OP0474 | M | TS7700 | The Copy Export operation did not export physical volume xxxxxx because the primary copy for virtual volume yyyyyy is currently unavailable. |
OP0475 | M | TS7700 | Copy Export did not export virtual volume xxxxxx because it was not able to premigrate the volume to the export pool. |
OP0476 | M | TS7700 | The event was cleared automatically. |
OP0480 | M | TS7700 | Service Call Home will be initiated. |
OP0481 | M | TS7700 | Service Call Home was initiated. |
OP0482 | M | TS7700 | Service Call Home was initiated with PMR number xxxxx,yyy,zzz. |
OP0483 | C | TS7700 | A permanent cache problem was encountered. |
OP0484 | C | TS7700 | A permanent cache problem was encountered. |
OP0485 | C | TS7700 | A 3956-CC6 permanent check was encountered. |
OP0486 | C | TS7700 | A CHECK1 condition was encountered. |
OP0487 | C | TS7700 | An adapter microcode CHECK1 condition occurred. |
OP0488 | C | TS7700 | A channel event occurred. |
OP0489 | C | TS7700 | An undetermined error occurred. |
OP0490 | C | TS7700 | An operator notification occurred. |
OP0491 | C | TS7700 | A microcode exception occurred in the ATL daemon. |
OP0492 | C | TS7700 | An undetermined error occurred. |
OP0493 | C | TS7700 | An informational message was presented by CU. |
OP0494 | C | TS7700 | An environmental problem has occurred. |
OP0495 | C | TS7700 | A microcode exception occurred in the tape daemon. |
OP0496 | C | TS7700 | The tape daemon detected a CRC error. |
OP0497 | C | TS7700 | A microcode exception occurred in the tape daemon. |
OP0498 | C | TS7700 | A microcode exception occurred in the BATE daemon. |
OP0499 | C | TS7700 | An error was detected and a Call Home has been generated |
OP0500 | M | TS7700 | The times displayed by the local and remote clusters nnnn differ by more than 5 seconds. |
OP0510 | M | TS7700 | nnnn logged into the Web interface. |
OP0511 | M | TS7700 | nnnn logged out of the Web interface. |
OP0512 | M | TS7700 | User mmmm the setting to send future events to host. |
OP0514 | M | TS7700 | Custom Role mmmm has been changed. |
OP0515 | M | TS7700 | SNMP settings have changed. Values are: SNMP Version: nn Enable SNMP Traps: mmmm Trap Community Name: xxxx |
OP0516 | M | TS7700 | Stand-alone mount was initiated for volume xxxxxx on device zzz. |
OP0517 | M | TS7700 | Stand-alone demount was initiated on device zzz. |
OP0518 | M | TS7700 | Node nnnn has been shut down. |
OP0519 | M | TS7700 | Custom Role mmmm has been created. |
OP0520 | M | TS7700 | Custom Role mmmm has been deleted. |
OP0521 | M | TS7700 | The security settings for local authentication have changed. Local Account Expiration: mmmm. The account will expire if the password is not changed in n days. |
OP0522 | M | TS7700 | The security settings for local authentication have changed. Local Account Expiration: mmmm. |
OP0523 | M | TS7700 | The security settings for local authentication have changed. Local Account Lock: mmmm. The account will be locked after n unsuccessful attempts to enter the password. |
OP0524 | M | TS7700 | The security settings for local authentication have changed. Local Account Lock: mmmm. |
OP0525 | C | TS7700 | A TAPE DRIVE FAILURE has occurred |
OP0526 | C | TS7700 | A FibrePath, FibreSwitch, or FibreInterface error has occurred. |
OP0527 | M | TS7700 | Stand-alone mount for volume xxxxxx on device zzz completed successfully. |
OP0528 | M | TS7700 | Stand-alone demount for volume xxxxxx on device zzz completed successfully. |
OP0529 | W | TS7700 | Stand-alone mount for volume xxxxxx on device zzz failed with error code nnnn. |
OP0530 | W | TS7700 | Stand-alone demount for volume xxxxxx on device zzz failed with error code nnnn. |
OP0531 | W | TS7700 | The network connection on grid port xx with IP address: n.m.y.z experienced a possible loss of connectivity. |
OP0532 | C | TS7700 | The network connection on grid port xx with IP address: n.m.y.z is not responding. |
OP0533 | M | TS7700 | The connection of local cluster to remote cluster nnnn with remote port xx and IP address: n.m.y.z of the remote cluster was unavailable for a brief time. |
OP0534 | W | TS7700 | The connection of local cluster to remote cluster nnnn with remote port xx and IP address: n.m.y.z of the remote cluster is losing packages, or the connection was unavailable. |
OP0535 | C | TS7700 | The connection of local cluster to remote cluster nnnn with remote port xx and IP address: n.m.y.z of the remote cluster, was not available. |
OP0536 | C | TS7700 | The link to remote cluster: nnnn with IP address: n.m.y.z is in the offline state. |
OP0537 | M | TS7700 | The connection of local cluster to remote cluster nnnn with remote port xx and remote IP address: n.m.y.z was unavailable for a brief time or because the local cluster was unable to retrieve the status of the remote adapter. |
OP0538 | W | TS7700 | The connection of local cluster to remote cluster nnnn with remote port xx and remote IP address: n.m.y.z was not available, because the local cluster reports the status of the remote adapter as not available. |
OP0539 | C | TS7700 | The connection of local cluster to remote cluster nnnn with remote port xx and IP address: n.m.y.z of the remote cluster was not available, because the state of the remote adapter appears as Failed. |
OP0540 | C | TS7700 | The link to remote cluster: nnnn With IP address: n.m.y.z is in the offline state. NTC (Network Traffic Controller) reports link state: mmmm |
OP0541 | W | TS7700 | Degraded state to gateway IP: gateway IP address. |
OP0542 | C | TS7700 | Failed state to gateway IP:gateway IP address. |
OP0543 | W | TS7700 | The primary and alternate grid adapters have different speeds: Primary nnnn link speed is: xxx Alternate mmmm link speed is: yyy |
OP0544 | C | TS7700 | The primary grid Ethernet adapter nnnn is down. |
OP0545 | C | TS7700 | The alternate grid Ethernet adapter nnnn is down. |
OP0546 | M | TS7700 | Could not retrieve the date on cluster nnnn. |
OP0547 | C | TS7700 | A time synchronization failure was detected between cluster nnnn and Cluster mmmm. |
OP0548 | W | TS7700 | There is no communication with one or more clusters in the Grid. |
OP0549 | W | TS7700 | One or more clusters in the Grid are in Service status. |
OP0550 | C | TS7700 | Service Call Home, TSSC was unable to generate a PMR number |
OP0551 | C | TS7700 | A permanent cache problem was encountered. |
OP0552 | C | TS7700 | A temporary cache problem was encountered. |
OP0553 | C | TS7700 | The cache has an unreadable sector. |
OP0554 | C | TS7700 | A cache power supply has failed. |
OP0555 | C | TS7700 | A cache power or fan assembly has failed. |
OP0556 | C | TS7700 | The cache has lost redundancy. |
OP0557 | C | TS7700 | A problem exists with the cabling or drive path inside the cache enclosure. |
OP0558 | C | TS7700 | A cache component has failed or been removed. |
OP0559 | C | TS7700 | A cache controller has failed or been removed. |
OP0560 | C | TS7700 | An environmental service module (ESM) canister in the cache has failed or been removed. |
OP0561 | C | TS7700 | A cache drive is missing. |
OP0562 | C | TS7700 | A cache drive is in a degraded state. |
OP0563 | C | TS7700 | A cache disk has reported errors. |
OP0564 | C | TS7700 | A cache RAID array has failed drives. |
OP0565 | C | TS7700 | An unsupported number of drive enclosures exists on a cache loop. |
OP0566 | C | TS7700 | The reported data rate of a cache drive channel is outside the expected range. |
OP0567 | C | TS7700 | The data rate could not be obtained on a drive channel for the cache. |
OP0568 | C | TS7700 | An incorrect number of enclosures exists on a cache loop. |
OP0569 | C | TS7700 | The number of enclosures on a cache loop cannot be determined. |
OP0570 | C | TS7700 | Mismatched drives exist in a cache array. |
OP0571 | C | TS7700 | Disk operation in the cache is degraded. |
OP0572 | C | TS7700 | Network errors were detected while connecting to the cache. |
OP0573 | C | TS7700 | An unreadable sector exists in the cache. |
OP0574 | C | TS7700 | A parity error occurred in the cache. |
OP0575 | C | TS7700 | A cache media error occurred. |
OP0576 | C | TS7700 | A temporary cache problem was encountered. |
OP0577 | C | TS7700 | The cache has an unreadable sector. |
OP0578 | C | TS7700 | A cache power supply has failed. |
OP0579 | C | TS7700 | A cache power or fan assembly has failed. |
OP0580 | C | TS7700 | The cache has lost redundancy. |
OP0581 | C | TS7700 | A problem exists with the cabling or drive path inside the cache enclosure. |
OP0582 | C | TS7700 | A cache component has failed or been removed. |
OP0583 | C | TS7700 | A cache controller has failed or been removed. |
OP0584 | C | TS7700 | An environmental service module (ESM) canister in the cache has failed or been removed. |
OP0585 | C | TS7700 | A cache drive is missing. |
OP0586 | C | TS7700 | A cache drive is in a degraded state. |
OP0587 | C | TS7700 | A cache disk has reported errors. |
OP0588 | C | TS7700 | A cache RAID array has failed drives. |
OP0589 | C | TS7700 | An unsupported number of drive enclosures exists on a cache loop. |
OP0590 | C | TS7700 | The reported data rate of a cache drive channel is outside the expected range. |
OP0591 | C | TS7700 | The data rate could not be obtained on a drive channel for the cache. |
OP0592 | C | TS7700 | An incorrect number of enclosures exists on a cache loop. |
OP0593 | C | TS7700 | The number of enclosures on a cache loop cannot be determined. |
OP0594 | C | TS7700 | Mismatched drives exist in a cache array. |
OP0595 | C | TS7700 | Disk operation in the cache is degraded. |
OP0596 | C | TS7700 | Network errors were detected while connecting to the cache. |
OP0597 | C | TS7700 | An unreadable sector exists in the cache. |
OP0598 | C | TS7700 | A parity error occurred in the cache. |
OP0599 | C | TS7700 | A cache media error occurred. |
OP0600 | W,S See note 2 | C | A temporary cache problem was encountered. |
OP0601 | C | TS7700 | The cache has an unreadable sector. |
OP0602 | C | TS7700 | A cache power supply has failed. |
OP0603 | C | TS7700 | A cache power or fan assembly has failed. |
OP0604 | C | TS7700 | The cache has lost redundancy. |
OP0605 | C | TS7700 | A problem exists with the cabling or drive path inside the cache enclosure. |
OP0606 | C | TS7700 | A cache component has failed or been removed. |
OP0607 | C | TS7700 | A cache controller has failed or been removed. |
OP0608 | C | TS7700 | An environmental service module (ESM) canister in the cache has failed or been removed. |
OP0609 | C | TS7700 | A cache drive is missing. |
OP0610 | C | TS7700 | A cache drive is in a degraded state. |
OP0611 | C | TS7700 | A cache disk has reported errors. |
OP0612 | C | TS7700 | A cache RAID array has failed drives. |
OP0613 | C | TS7700 | An unsupported number of drive enclosures exists on a cache loop. |
OP0614 | C | TS7700 | The reported data rate of a cache drive channel is outside the expected range. |
OP0615 | C | TS7700 | The data rate could not be obtained on a drive channel for the cache. |
OP0616 | C | TS7700 | An incorrect number of enclosures exists on a cache loop. |
OP0617 | C | TS7700 | The number of enclosures on a cache loop cannot be determined. |
OP0618 | C | TS7700 | Mismatched drives exist in a cache array. |
OP0619 | C | TS7700 | Disk operation in the cache is degraded. |
OP0620 | C | TS7700 | Network errors were detected while connecting to the cache. |
OP0621 | C | TS7700 | An unreadable sector exists in the cache. |
OP0622 | C | TS7700 | A parity error occurred in the cache. |
OP0623 | C | TS7700 | A cache media error occurred. |
OP0624 | C | TS7700 | An error was detected in the disk cache. |
OP0625 | C | TS7700 | A system reboot interrupted a call home. |
OP0626 | C | TS7700 | One or more issues on the system have persisted for longer than 24 hours. |
OP0627 | C | TS7700 | There is a problem with network communication required for autonomic ownership takeover. |
OP0628 | C | TS7700 | The cache controller is not configured. |
OP0629 | C | TS7700 | The cache file system is inefficiently allocating its available space. |
OP0630 | C | TS7700 | There is a problem with the network fail over code. |
OP0631 | C | TS7700 | The error detection feature has restarted five times in 24 hours. |
OP0632 | C | TS7700 | The available memory is not configured correctly. |
OP0633 | C | TS7700 | A CPU has failed. |
OP0634 | C | TS7700 | Port 0 on the customer network has failed. |
OP0635 | C | TS7700 | Port 1 on the customer network has failed. |
OP0636 | C | TS7700 | Both Ethernet routers have failed. |
OP0637 | C | TS7700 | The primary Ethernet router has failed. |
OP0638 | C | TS7700 | The alternate Ethernet router has failed. |
OP0639 | C | TS7700 | The Network Time Protocol (NTP) server is not responding. |
OP0640 | C | TS7700 | A port in an Ethernet router has failed. |
OP0641 | C | TS7700 | A port in an Ethernet router shows increasing errors. |
OP0642 | C | TS7700 | Communication between the disk cache and the primary switch has failed. |
OP0643 | C | TS7700 | Communication between the disk cache and the alternate switch has failed. |
OP0644 | C | TS7700 | One or more arrays are not encrypted. |
OP0645 | C | TS7700 | This is a cache Call Home test. |
OP0646 | W | TS7700 | Encryption is enabled on the virtual tape library. Device xxxxxxx is not encryption-capable. The device was made unavailable. |
OP0647 | C | TS7700 | Host Adapter adapter is not available and offline. |
OP0648 | I | TS7700 | Host Adapter ficon adapter link link number is down. |
OP0649 | C | TS7700 | No IBM media changer devices were found on the system. |
OP0650 | W | TS7700 | The system identified number of smc devices IBM media changer devices. This is an incorrect number of devices. |
OP0651 | I | TS7700 | The IBM media changer smc device name is in an unknown state. |
OP0652 | I | TS7700 | The fibre channel adapter for tape interface interface number cannot be identified. |
OP0653 | I | TS7700 | The drive name drive name does not match port port name. |
OP0654 | C | TS7700 | Drives could not be configured on a 3590 or 3592 tape drive. |
OP0655 | W | TS7700 | The physical tape SCSI device rmt device is in the state: device state. |
OP0656 | C | TS7700 | Primary and alternate paths for tape SCSI device rmt device are unavailable. |
OP0657 | W | TS7700 | The tape drive device rmt device is shown as device state in the cluster. |
OP0658 | I | TS7700 | The tape drive device rmt device is in the state device state. |
OP0659 | W | TS7700 | The path primary or alternate for tape drive rmt device name is unavailable. |
OP0660 | C | TS7700 | Both primary and alternate paths for tape drive device rmt device name are unavailable. |
OP0661 | I | TS7700 | Tape device rmt device name is in an unknown state. |
OP0662 | I | TS7700 | The path Primary or Alternate to tape device rmt device name is disabled. |
OP0663 | C | TS7700 | No tape drives were found in the system. |
OP0664 | W | TS7700 | All paths on the primary or alternate lower channel protocol interface failed. |
OP0665 | C | TS7700 | All paths on the primary and alternate lower fibre channel protocol interface failed. |
OP0666 | C | TS7700 | The primary and alternate paths for rmt device name on the lower fibre channel protocol interface failed. |
OP0667 | W | TS7700 | The tape SCSI device path rmt device name on lower fibre channel protocol interface failed. |
OP0668 | I | TS7700 | The state of the drive device name on the Library type model could not be obtained. |
OP0669 | I | TS7700 | The tape drive device name is not available to the phyiscal library Library type model. |
OP0670 | I | TS7700 | This system contains both E05 drives in native mode and J1A drives. |
OP0671 | I | TS7700 | All drives are reported as in the busy state. |
OP0672 | I | TS7700 | The world wide node name (WWNN) could not be obtained for drive device name. |
OP0673 | I | TS7700 | The physical volume status could not be obtained. |
OP0674 | I | TS7700 | No physical volumes are found on the system. |
OP0675 | I | TS7700 | The physical volume pool status could not be obtained. |
OP0676 | W | TS7700 | Physical volume pool pool name is out of scratch volumes. |
OP0677 | I | TS7700 | Volume volume name reports a state volume state with access in access status status. |
OP0678 | I | TS7700 | LDAP server Primary or Secondary connection (IP) experienced a loss of connectivity. |
OP0679 | C | TS7700 | LDAP server Primary or Secondary connection (IP) is not responding. |
OP0680 | C | TS7700 | LDAP server Primary or Secondary service is down. IP:IP Port:Port Number |
OP0681 | W | TS7700 | LDAP server Primary or Secondary connection is not correctly configured. IP: IP Port:port number |
OP0682 | I | TS7700 | Authentication server AuthServer id connection (IP) experienced a loss of connectivity. |
OP0683 | C | TS7700 | Authentication server AuthServer id service is down. IP:IP Port:Port number |
OP0684 | W | TS7700 | The connection to authentication server AuthServer id is not correctly configured. IP: IP Port:Port number |
OP0687 | C | TS7700 | An unknown cache problem was encountered. Disk Model:Disk Model |
OP0688 | C | TS7700 | The cache has an unreadable sector error. Disk Model:Disk Model |
OP0689 | C | TS7700 | A cache power supply has failed. Disk Model:Disk Model |
OP0690 | C | TS7700 | A loss of redundancy has occurred in cache. The disk model is:Disk Model |
OP0691 | C | TS7700 | A problem exists with the cabling or drive path inside the cache enclosure. Disk Model:Disk Model |
OP0692 | C | TS7700 | A DDM is missing. The disk model is:Disk Model |
OP0693 | C | TS7700 | A cache controller has failed or been removed. The disk model is:Disk Model |
OP0694 | C | TS7700 | An environmental service module (ESM) canister in the cache has failed or been removed. Disk Model:Disk Model |
OP0695 | C | TS7700 | A cache component has failed or been removed. Disk Model:Disk Model |
OP0696 | C | TS7700 | Failed drives exist in a cache RAID array. The disk model is:Disk Model |
OP0697 | C | TS7700 | Mismatched drives exist in a cache array. Disk Model:Disk Model |
OP0698 | C | TS7700 | Disk operation in the cache is degraded. Disk Model:Disk Model |
OP0699 | C | TS7700 | Network errors were detected while connecting to the cache. Disk Model:Disk Model |
OP0700 | C | TS7700 | An unsupported number of drive enclosures exists on a cache loop. Disk Model:Disk Model |
OP0701 | C | TS7700 | The reported data rate of a cache drive channel is outside the expected range. Disk Model:Disk Model |
OP0702 | C | TS7700 | The data rate could not be obtained on a drive channel for the cache. Disk Model:Disk Model |
OP0703 | C | TS7700 | An incorrect number of enclosures exists on a cache loop. Disk Model:Disk Model |
OP0704 | C | TS7700 | The number of enclosures on a cache loop cannot be determined. Disk Model:Disk Model |
OP0705 | C | TS7700 | An unreadable sector exists in the cache. Disk Model:Disk Model |
OP0706 | C | TS7700 | A disk cache parity mismatch error occurred in the cache. Disk Model:Disk Model |
OP0707 | C | TS7700 | A cache media error occurred. Disk Model:Disk Model |
OP0708 | C | TS7700 | A cache power or fan assembly has failed. Disk Model:Disk Model |
OP0709 | C | TS7700 | A cache drive is in a degraded state. Disk Model:Disk Model |
OP0710 | C | TS7700 | A cache disk has reported errors. Disk Model:Disk Model |
OP0711 | C | TS7700 | The cache battery in a degraded state. The disk model is:Disk Model |
OP0712 | C | TS7700 | The cache controller in a degraded state. The disk model is:Disk Model |
OP0713 | C | TS7700 | Information for this event cannot be displayed on this cluster. |
PP0010 | M | VTS/TS7700 | Due to an imbalance of defined SMS constructs across the Domain, the constructs were automatically created with the default actions on the following distributed Cluster(s): xx. |
PP0011 | M | VTS/TS7700 | Due to an imbalance of defined SMS constructs across the Domain, the default constructs were assigned on the following distributed Cluster(s): xx. |
VT0103 | M | VTS/TS7700 | Warning: Primary Cluster volume xxxxxx copied from Secondary. |
- Two impact codes are listed. The first has to do with the physical library the condition occurred in, the second the impact if there is a VTS or TS7700 that the host is connected to.
- Two impact codes are listed. The first one is if communication is lost to just one of the two encryption key servers. The second is if communication is lost to both encryption key servers.