3995 Volume Statistics Summary

This volume statistics summary presents all 3995 cartridge statistical data and all 3995 permanent errors counted and sorted by volume, date, and time.

Figure 1 shows an example of the 3995 volume statistics summary.
Figure 1. 3995 Volume Statistics Summary
3995 VOLUME STATISTICS SUMMARY                    1 REPORT DATE 167 97
                                                    PERIOD FROM 102 97
**** SORTED BY VOLUME DATE AND TIME ****                   TO   118 97
 2     3          4   5      6    7  8   9    10  11      12         13          14          15          16            17 
                                              PCT TOTAL
                                  C           SPR NO.
VOLUME USER INFO. DTE TIME        P  DRV MED. SEC SPARE   MB/ERR PERM----------- MB/ERR TEMP----------- SEEK ERRS---- LOAD ERRS----
ID     10 BYTES   DAY HHMMSS CUA  U  NO. TYPE USD SECTRS  READ(CT)   WRITE(CT)   READ(CT)   WRITE(CT)   PERM   TEMP   PERM   TEMP
------ ---------- --- ------ ---- -- --- ---- --- ------  ---------------------- ---------------------- ------------- -------------
O00578            117 110545 0285 00   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00578 NAME OF CO 117 110653 0284 01   3 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00578 NAME OF CO 117 110702 0284 01   3 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0

O00582            117 104727 0280 01   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00582 NAME OF CO 117 110629 0283 00   2 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00582 NAME OF CO 117 110638 0283 01   2 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0

O00602            117 111014 0285 01   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00602 NAME OF CO 117 111119 0284 01   3 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00602 NAME OF CO 117 111129 0284 02   3 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0

O00642            117 111726 0285 01   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00642 NAME OF CO 117 111833 0283 01   2 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00642 NAME OF CO 117 111844 0283 01   2 8000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0

O00671            117 104727 0285 01   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0

O00673            117 104727 0282 01   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0

O00677            117 103340 0280 00   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0
O00677            117 104727 0280 00   0 0000   0      0    --  (  0)  --  (  0)   --  (  0)  --  (  0)      0      0      0      0

 18 
CPU   MODEL    SERIAL NUMBER
00    9021XA   110947
01    9021XA   210947
02    9021XA   010947
 1 
REPORT DATE is the Julian date the report ran.

PERIOD FROM is the Julian date of the earliest record.

PERIOD TO is the Julian date of the latest record.

 2 
VOLUME ID is the volume ID used with the command to be processed for the addressed device.
 3 
USER INFO. 10 BYTES are the first 10 bytes of owner information.
 4 
DTE DAY is the date of incident.
 5 
TIME HHMMSS is the time of incident.
 6 
CUA is the device number consisting of channel address and unit address.
 7 
CPU is the CPU version/serial number.
 8 
DRV NO. is the drive number.
 9 
MED. TYPE is the media type.
 10 
PCT SPR SEC USD is the percent used of spare sectors.
 11 
TOTAL NO. SPARE SECTRS is the total number of spare sectors.
 12 
Total number of megabytes read (READ) divided by the number of permanent read errors (CT) on a specific CUA/CPU.
 13 
Total number of megabytes written (WRITE) divided by the number of permanent write errors (CT) on a specific CUA/CPU.
 14 
Total number of megabytes read (READ) divided by the number of temporary read errors (CT) on a specific CUA/CPU.
 15 
Total number of megabytes written (WRITE) divided by the number of temporary write errors (CT) on a specific CUA/CPU.
 16 
Total number of permanent (PERM) and temporary (TEMP) seek errors on a specific CUA/CPU.
 17 
Total number of permanent (PERM) and temporary (TEMP) load/unload errors on a specific CUA/CPU.
 18 