This part of the exception report series provides the primary listing of events to determine if the TAPE subsystem has excessive errors or is operating within acceptable limits.
This report provides the information to connect these events to the other reports in the series that have more details.
Examples of these reports are listed as follows.
REPORT | SEE TOPIC |
---|---|
3590 Subsystem Exception Report Example | Figure 1 |
3592 Subsystem Exception Report Example | Figure 2 |
TAPE SUBSYSTEM EXCEPTION REPORT REPORT DATE 080 97
PERIOD FROM 037 97
TO 079 97
*** SEQUENCE BY PROBABLE FAILING UNIT ***
6
PROBABLE DEVICE 4 5 --------TOTALS--------
FAILING TYPE/ FAILURE DEVNO OBR OBR
UNIT VOLID AFFECT CPU /CUA SIMS MIMS PERM TEMP
******************************************************************************************************
2 1 3
MEDIA TOTAL 0 2 0 0
JANZ01 DATA DEGRADED IN PARTITION 08 0883 0 1 0 0
JANZ99 DATA DEGRADED IN PARTITION 00 08A9 0 1 0 0
DEVICE TOTAL 1 0 0 1
3590-B11 PREVENTIVE MAINTENANCE COMPLETED 08 0883 1 0 0 0
3590-B11 LOADER INTERVENTION REQUIRED 0A 0883 0 0 0 1
CONTROLLER TOTAL 1 0 0 3
3590-A00 RESETTING EVENT 08 0880 0 0 0 1
3591/3490EMU RECOVERED CHECK-ONE FAILURE 08 0880 0 0 0 1
3590/3490EMU TAPE LENGTH INCOMPATIBLE 08 0880 0 0 0 1
3590-A00 EFFECT OF FAILURE IS UNKNOWN 08 0887 1 0 0 0
CPU MODEL SERIAL NUMBER
00 3090XA 045783
01 9021XA 110341
02 9221XA 0D0481
03 3090XA 245783
04 3090XA 145783
05 3090XA 155783
06 3090XA 055783
07 3090XA 255783
08 9672XA 061035
09 9672XA 461035
0A 9672XA 161035
PFU | DESCRIPTION |
---|---|
MEDIA | Media (tape volume) |
DEVICE | Device involved (3590) |
CONTROLLER | Controller (drive string controller, or something common to more than one device on the string) |
LIBRARY | Tape library |
TYPE | DESCRIPTION |
---|---|
SIMS | The count of SIM messages reported by the unit and totaled for the PFU within the given failure. |
MIMS | The count of MIM messages reported by the unit and totaled for the PFU within the given failure. |
PERM | The count of permanent errors recorded against the unit and totaled for the PFU within the given failure affect. (A permanent error is indicated by a zero temporary error bit in the OBR record.) |
TEMP | The count of temporary errors recorded against the unit and totaled for the PFU within the given failure affect. |
TAPE SUBSYSTEM EXCEPTION REPORT REPORT DATE 220 05
PERIOD FROM 076 02
TO 077 02
*** SEQUENCE BY PROBABLE FAILING UNIT ***
PROBABLE DEVICE --------TOTALS----------
FAILING TYPE/ FAILURE DEVNO OBR OBR
UNIT VOLID AFFECT CPU /CUA SIMS MIMS PERM TEMP
******************************************************************************************************
LIBRARY TOTAL 0 0 0 1
3570-CXX LIBRARY INFORMATIONAL DATA 00 07C2 0 0 0 1
DEVICE TOTAL 0 0 2 1
3590-H1X LIBRARY DRIVE NOT UNLOADED 02 0C24 0 0 1 0
3592-J1X WORM OVERWRITE REJECTED 03 0C27 0 0 0 1
3592-E05 LIBRARY DRIVE NOT UNLOADED 00 1B90 0 0 0 1
3592-E06 LIBRARY DRIVE NOT UNLOADED 00 1B90 0 0 0 1
3590 DEVICE SUMMARY REPORT DATE 295 07
PERIOD FROM 195 06
TO 195 06
DEVICE ADDRESS REAL / EMULATED DEVICE TYPE
0FA2 3592-J1X / 3490-CXX
0FA3 3592-E05 / 3590-B1X
0FA4 3592-E06 / 3590-B1X
CPU MODEL SERIAL NUMBER
00 2084XA 132906
01 2084XA 142906