Tells EREP to
Produce a threshold summary
for your 3410, 3420, and 8809 tape devices. The report includes only
those records with read/write error counts equal to or greater than
the values specified on the parameter.
Syntax
THRESHOLD=(xxx,yyy)
- xxx
- The one-to-three digit decimal (leading zeros not required) threshold
value for temporary read errors. Maximum value is 255.
- yyy
- The one-to-three digit decimal (leading zeros not required) threshold
value for temporary write errors. Maximum value is 255.
Defaults
Unless
you specifically code THRESHOLD and some threshold values, EREP produces
no threshold summary.
Coding
- You cannot code THRESHOLD alone; you also need the threshold values
on the parameter.
- If you do not specifically code DEV=(3410), DEV=(3420), or DEV=(8809),
EREP processes records from all three device types. If you code DEV=(34XX),
EREP processes records from all three device types.
- You cannot code ACC=Y with THRESHOLD.
- You cannot code ZERO=Y with THRESHOLD; not all the records are
used for the report, so EREP does not clear the ERDS even if you request
it.
Parameter Conflicts
Parameters |
ACC |
CPUCUA |
LIA/LIBADR |
SHORT |
TERMN |
ZERO |
CPU |
ERRORID |
MOD |
SYMCDE |
TYPE |
|
Notes
- The threshold summary uses only OBR and MDR records; you cannot
select records by type.
- For this report, EREP accumulates STARTIO (SIO) counts for records
flagged as demount records.
Examples
THRESHOLD=(1,5)
THRESHOLD=(005,015)