DASD Subsystem Exception, Part 2

Subsystem exception DASD (2) reports list only the SIM (A3) records. Units which rely on SIMs for statement of service requirement are shown in this report.

Figure 1 shows an example of the DASD subsystem exception, part 2.
Figure 1. DASD Subsystem Exception, Part 2
SUBSYSTEM  EXCEPTION                                REPORT DATE 105 97
        DASD (2)                                    PERIOD FROM 100 97
                                                           TO   104 97
PROBABLE
FAILING              FAILURE            PHYSICAL
UNIT                 AFFECT     CPU     ADDRESS     SIMS
*********************************************************************
CHAN    07          CHAN/SCU            TOTAL         1
                                 01     10221.2       1
------------------+----------+--------+--------------+------+-------+
SCU  34988.3        SCU/CTRL            TOTAL          3
       9341                      03+    22887.3-XX     3
------------------+----------+--------+--------------+------+-------+
CTLR FFFFF.0-XX     SCU/CTLR            TOTAL          1
       9343                      01     FFFFF.0-XX     1
------------------+----------+--------+--------------+------+-------+
MULT 12245.X-XX     MULTIPLE            TOTAL          2
       9345                      01     12245.1-1A     1
                                 02     12245.2-1B     1
------------------+----------+--------+--------------+------+-------+
DEV  23345.X-02     CTLR/DEV            TOTAL          2
       9345                      01+    23345.0-02     2
*********************************************************************
   0 UNIT(S) EXCLUDED DUE TO LIMITS