System Error Summary, Part 2

Part 2 of the system error summary is a chronological listing of the following: System Error Summary, Part 2 shows an example of part 2 of the system error summary report.

System Error Summary, Part 2

SYSTEM ERROR SUMMARY                                REPORT DATE 065 97
      (PART 2)                                      PERIOD FROM 041 97
                                                           TO   059 97

                            PHYSICAL       PHYSICAL  ERROR                                                   PROBABLE
    TIME       JOBNAME  CPU    ID     TYPE ADDRESS    PATH VOLUME   ERROR DESCRIPTION                      FAILING UNIT

 DATE 041/97
 11:59:12:87   GAM297    05 FF.X-17   3380-JK 0297 02-0297 RAS297   PERMANENT DATA CHECK                   VOLUME
 12:07:58:52   P$SPOOL2  01 36-XX-XX  3880    0470 0C-0470          PERMANENT OVERRUN                      CHANNEL

 DATE 042/97
 02:24:35:55   I$ITA80   03 XX-10-02  3380    0A82 56-0A82          PERMANENT EQUIPMENT CHECK              DEVICE
 09:10:37:29   OCT9USG1  07   N/A     3422    0156 01-0156 340002   N/A                                    HARDWARE
 09:55:02:83   MAINT     00   N/A     9347    0C70    0C70          N/A                                    HARDWARE
 13:28:25:71   D#CLP471  01 32-XX-XX  3880    0471 02-0471          PERMANENT OVERRUN                      CHANNEL

 DATE 043/97
 00:F3:F9:4E   ICFSMPLB  08   N/A     3420    0180    0180          NOT CAPABLE                            HARDWARE
 01:53:41:99   PAUSEBG   00   N/A     9335    0D53    0D53 KEST53   PERMANENT EQUIPMENT CHECK              DEVICE
 04:22:15:46   SORTCHK   08   N/A     3430    0190    0190          N/A                                    HARDWARE
 09:53:09:10   GAM704    00 20.X-04   3380-JK 0704 17-0704 RAS704   PERMANENT DATA CHECK                   VOLUME
 14:28:49:77   TSIMLRW   04   N/A     3480    03EB    EB40 TPF490   PERMANENT EQUIPMENT CHECK              DEVICE

 DATE 044/97
 00:46:37:09   MAINT     00   N/A     9347    0C70    0C70          N/A                                    HARDWARE
 01:01:EE:7B   ICFSMPLB  08   N/A     3420    0181    0181          UNDEFINED                              HARDWARE
 04:08:28:13   MAINT     00   N/A     9347    0C70    0C70          N/A                                    HARDWARE
 12:31:46:69   GAM7C3    05 60.X-03   3380-JK 07C3 17-07C3 RAS7C3   PERMANENT EQUIPMENT CHECK              DEVICE
 12:31:46:70   GAM7C3    05 60.X-03   3380-JK 7C3B 07-07C3 RAS7C3   PERMANENT EQUIPMENT CHECK              DEVICE
 18:18:31:01   #IPORES   06   N/A     3330    0428    0428 IPORES   PERMANENT EQUIPMENT CHECK              DEVICE
 18:43:38:16   #IPORES   06   N/A     3330    0428    0E28 IPORES   PERMANENT EQUIPMENT CHECK              DEVICE

 DATE 045/97
 10:26:02:92   GAM7C3    05 60.X-03   3380-JK 07C3 17-07C3 RAS7C3   PERMANENT EQUIPMENT CHECK              DEVICE
 10:26:03:25   GAM7C3    05 60.X-03   3380-JK 07C3 17-07C3 RAS7C3   PERMANENT EQUIPMENT CHECK              DEVICE
 10:26:03:67   GAM7C3    05 60.1-XX   3380-JK 07C3 17-07C3 RAS7C3   PERMANENT EQUIPMENT CHECK              CONTROLL
ER
 14:25:47:01   DSF       0D XX-84-04  3380    0734    0734 PAK167   PERMANENT DATA CHECK                   VOLUME
 18:03:30:85   #IPORES   06   N/A     3330    0428    0428 IPORES   PERMANENT EQUIPMENT CHECK              DEVICE
 18:48:02:12   BSAM01    0E XX-95-XX  3380-DE 0DB6 00-0DB6 EVERD6   PERMANENT PATH ERROR                   CONTROLL
ER

 DATE 046/97
 03:00:13:92   RMF       0F A8-XX-XX  3880    0100 01=0100 PAGE01   PERMANENT SUB-STG EQPMT CHECK          SCU
 14:24:12:55   D15ELP1F  06   N/A     34XX     575     N/A L00200   DDR INDICATES SWAP TO PCUA 570         N/A
 18:10:48:55   MAINT     00   N/A     9347    0C70    0C70          N/A                                    HARDWARE

 DATE 047/97
 01:50:41:32   DSSDUMP   0F   N/A     3480    02B2    02B2          N/A                                    VOLUME/C
D
 02:41:29:62   PAGE ERR  03 A8-XX-XX  3880    0119 51-0111          SUB-STORAGE MUST BE INITIALIZED        SCU
 02:58:03:77   PAGE ERR  03 A8-XX-XX  3880    0119 01-0111          SUB-STORAGE IS UNUSABLE                SCU
 05:32:25:77   MAINT     00   N/A     9347    0C70    0C70          N/A                                    HARDWARE
     *****    2 DUPLICATE LINES WITHIN THIS TIME INTERVAL HAVE NOT BEEN PRINTED
 10:14:52:90   MAINT     00   N/A     9347    0C70    0C70          N/A                                    HARDWARE
 13:50:16:74   NO NAME   00   N/A     9335    0F50    0F50 DSFF50   PERMANENT EQUIPMENT CHECK              DEVICE
SYSTEM ERROR SUMMARY                                REPORT DATE 065 97
      (PART 2)                                      PERIOD FROM 041 97
                                                           TO   059 97
                               1                                          2                                      3 
                            PHYSICAL       PHYSICAL  ERROR                                                   PROBABLE
    TIME       JOBNAME  CPU    ID     TYPE ADDRESS    PATH VOLUME   ERROR DESCRIPTION                      FAILING UNIT

 DATE 054/97
 13:18:24:18   EREP      0A   N/A     9348    0490    0490 V00002   N/A                                    HARDWARE
 13:20:34:47   EREP      0A   N/A     9348    0490    0490 V00002   N/A                                    VOLUME/C
D
 13:27:02:64   EREP      0A   N/A     9348    0490    0490 V00002   N/A                                    HARDWARE
     *****    2 DUPLICATE LINES WITHIN THIS TIME INTERVAL HAVE NOT BEEN PRINTED
 13:27:52:33   EREP      0A   N/A     9348    0490    0490 V00002   N/A                                    HARDWARE
 14:00:22:39   EREP      0A   N/A     9348    0490    0490 V00004   N/A                                    HARDWARE
 14:00:29:43   EREP      0A   N/A     9348    0490    0490 V00004   N/A                                    VOLUME/C
D
 14:05:16:99   EREP      0A   N/A     9348    0490    0490 V00004   N/A                                    HARDWARE
 14:31:50:57   EREP      0A   N/A     9348    0490    0490 V00006   N/A                                    HARDWARE

************************************************************************ ***************************************************

CPU  MODEL   SERIAL
 00  9375    234567
 01  9371    000000
 02  9021XA  110947
 03  9021XA  210947
 04  4341    015760
 05  3033    021929
 06  2094XA  048940
 07  2084XA  05A8BA
 08  2084XA  05A5BA
 09  2084XA  04A8BA
 0A  2084XA  03A8BA
 0B  2084XA  0356BF
 0C  2084XA  02A8BA
 0D  2084XA  02A5BA
 0E  2084XA  0256BF
 0F  2084XA  019F1A
 1 
The PHYSICAL ID field contents are described in the following table:
DEVICE FIELD CONTAINS
DASD providing physical ID or DASDID statements A combination of the storage controller, control unit, and device (SCUID-CTLID-DEVID)
Tape The field contains N/A (not available)
DASD without physical ID or DASDID statements
 2 
The ERROR DESCRIPTION field contains subsystem-dependent information. The DDR swap description appears in this field.
 3 
The possible PROBABLE FAILING UNITS are:
Units
CHANNEL CONTROLLER
DEVICE HARDWARE
SCU (Storage Control Unit) UNDETERMINED
UNKNOWN VOLUME
VOLUME/CD (for tape)  
Note: A PFU of N/A appears in the case of a DDR record.