Part 2 of the system error summary is a chronological listing of
the following:
- Permanent DASD, optical, and tape errors
- DDR calls
System Error Summary, Part 2 shows an example of part
2 of the system error summary report.
System Error Summary, Part 2
SYSTEM ERROR SUMMARY REPORT DATE 065 97
(PART 2) PERIOD FROM 041 97
TO 059 97
PHYSICAL PHYSICAL ERROR PROBABLE
TIME JOBNAME CPU ID TYPE ADDRESS PATH VOLUME ERROR DESCRIPTION FAILING UNIT
DATE 041/97
11:59:12:87 GAM297 05 FF.X-17 3380-JK 0297 02-0297 RAS297 PERMANENT DATA CHECK VOLUME
12:07:58:52 P$SPOOL2 01 36-XX-XX 3880 0470 0C-0470 PERMANENT OVERRUN CHANNEL
DATE 042/97
02:24:35:55 I$ITA80 03 XX-10-02 3380 0A82 56-0A82 PERMANENT EQUIPMENT CHECK DEVICE
09:10:37:29 OCT9USG1 07 N/A 3422 0156 01-0156 340002 N/A HARDWARE
09:55:02:83 MAINT 00 N/A 9347 0C70 0C70 N/A HARDWARE
13:28:25:71 D#CLP471 01 32-XX-XX 3880 0471 02-0471 PERMANENT OVERRUN CHANNEL
DATE 043/97
00:F3:F9:4E ICFSMPLB 08 N/A 3420 0180 0180 NOT CAPABLE HARDWARE
01:53:41:99 PAUSEBG 00 N/A 9335 0D53 0D53 KEST53 PERMANENT EQUIPMENT CHECK DEVICE
04:22:15:46 SORTCHK 08 N/A 3430 0190 0190 N/A HARDWARE
09:53:09:10 GAM704 00 20.X-04 3380-JK 0704 17-0704 RAS704 PERMANENT DATA CHECK VOLUME
14:28:49:77 TSIMLRW 04 N/A 3480 03EB EB40 TPF490 PERMANENT EQUIPMENT CHECK DEVICE
DATE 044/97
00:46:37:09 MAINT 00 N/A 9347 0C70 0C70 N/A HARDWARE
01:01:EE:7B ICFSMPLB 08 N/A 3420 0181 0181 UNDEFINED HARDWARE
04:08:28:13 MAINT 00 N/A 9347 0C70 0C70 N/A HARDWARE
12:31:46:69 GAM7C3 05 60.X-03 3380-JK 07C3 17-07C3 RAS7C3 PERMANENT EQUIPMENT CHECK DEVICE
12:31:46:70 GAM7C3 05 60.X-03 3380-JK 7C3B 07-07C3 RAS7C3 PERMANENT EQUIPMENT CHECK DEVICE
18:18:31:01 #IPORES 06 N/A 3330 0428 0428 IPORES PERMANENT EQUIPMENT CHECK DEVICE
18:43:38:16 #IPORES 06 N/A 3330 0428 0E28 IPORES PERMANENT EQUIPMENT CHECK DEVICE
DATE 045/97
10:26:02:92 GAM7C3 05 60.X-03 3380-JK 07C3 17-07C3 RAS7C3 PERMANENT EQUIPMENT CHECK DEVICE
10:26:03:25 GAM7C3 05 60.X-03 3380-JK 07C3 17-07C3 RAS7C3 PERMANENT EQUIPMENT CHECK DEVICE
10:26:03:67 GAM7C3 05 60.1-XX 3380-JK 07C3 17-07C3 RAS7C3 PERMANENT EQUIPMENT CHECK CONTROLL
ER
14:25:47:01 DSF 0D XX-84-04 3380 0734 0734 PAK167 PERMANENT DATA CHECK VOLUME
18:03:30:85 #IPORES 06 N/A 3330 0428 0428 IPORES PERMANENT EQUIPMENT CHECK DEVICE
18:48:02:12 BSAM01 0E XX-95-XX 3380-DE 0DB6 00-0DB6 EVERD6 PERMANENT PATH ERROR CONTROLL
ER
DATE 046/97
03:00:13:92 RMF 0F A8-XX-XX 3880 0100 01=0100 PAGE01 PERMANENT SUB-STG EQPMT CHECK SCU
14:24:12:55 D15ELP1F 06 N/A 34XX 575 N/A L00200 DDR INDICATES SWAP TO PCUA 570 N/A
18:10:48:55 MAINT 00 N/A 9347 0C70 0C70 N/A HARDWARE
DATE 047/97
01:50:41:32 DSSDUMP 0F N/A 3480 02B2 02B2 N/A VOLUME/C
D
02:41:29:62 PAGE ERR 03 A8-XX-XX 3880 0119 51-0111 SUB-STORAGE MUST BE INITIALIZED SCU
02:58:03:77 PAGE ERR 03 A8-XX-XX 3880 0119 01-0111 SUB-STORAGE IS UNUSABLE SCU
05:32:25:77 MAINT 00 N/A 9347 0C70 0C70 N/A HARDWARE
***** 2 DUPLICATE LINES WITHIN THIS TIME INTERVAL HAVE NOT BEEN PRINTED
10:14:52:90 MAINT 00 N/A 9347 0C70 0C70 N/A HARDWARE
13:50:16:74 NO NAME 00 N/A 9335 0F50 0F50 DSFF50 PERMANENT EQUIPMENT CHECK DEVICE
SYSTEM ERROR SUMMARY REPORT DATE 065 97
(PART 2) PERIOD FROM 041 97
TO 059 97
1 2 3
PHYSICAL PHYSICAL ERROR PROBABLE
TIME JOBNAME CPU ID TYPE ADDRESS PATH VOLUME ERROR DESCRIPTION FAILING UNIT
DATE 054/97
13:18:24:18 EREP 0A N/A 9348 0490 0490 V00002 N/A HARDWARE
13:20:34:47 EREP 0A N/A 9348 0490 0490 V00002 N/A VOLUME/C
D
13:27:02:64 EREP 0A N/A 9348 0490 0490 V00002 N/A HARDWARE
***** 2 DUPLICATE LINES WITHIN THIS TIME INTERVAL HAVE NOT BEEN PRINTED
13:27:52:33 EREP 0A N/A 9348 0490 0490 V00002 N/A HARDWARE
14:00:22:39 EREP 0A N/A 9348 0490 0490 V00004 N/A HARDWARE
14:00:29:43 EREP 0A N/A 9348 0490 0490 V00004 N/A VOLUME/C
D
14:05:16:99 EREP 0A N/A 9348 0490 0490 V00004 N/A HARDWARE
14:31:50:57 EREP 0A N/A 9348 0490 0490 V00006 N/A HARDWARE
************************************************************************ ***************************************************
CPU MODEL SERIAL
00 9375 234567
01 9371 000000
02 9021XA 110947
03 9021XA 210947
04 4341 015760
05 3033 021929
06 2094XA 048940
07 2084XA 05A8BA
08 2084XA 05A5BA
09 2084XA 04A8BA
0A 2084XA 03A8BA
0B 2084XA 0356BF
0C 2084XA 02A8BA
0D 2084XA 02A5BA
0E 2084XA 0256BF
0F 2084XA 019F1A
- 1
- The PHYSICAL ID field contents are described
in the following table:
DEVICE |
FIELD CONTAINS |
DASD providing physical ID or DASDID statements |
A combination of the storage controller, control
unit, and device (SCUID-CTLID-DEVID) |
Tape |
The field contains N/A (not available) |
DASD without physical ID or DASDID statements |
- 2
- The ERROR DESCRIPTION field contains subsystem-dependent
information. The DDR swap description appears in this field.
- 3
- The possible PROBABLE FAILING UNITS are:
Units |
CHANNEL |
CONTROLLER |
DEVICE |
HARDWARE |
SCU (Storage Control Unit) |
UNDETERMINED |
UNKNOWN |
VOLUME |
VOLUME/CD (for tape) |
|
Note: A PFU of N/A
appears in the case of a DDR record.
|