The SLH records format subchannel detected errors that do not terminate system operation.
The SLH record and the CRW record combine to replace the CCH record written for S⁄370 ™ channel checks.
The record contains subchannel dependent error information from the extended status word (ESW) showing the type and location of the error.
Figures containing examples of these reports are on the pages shown in the following table:
REPORT | SEE FIGURE |
---|---|
SLH Detail Edit Report, Device Type 3390 | Subchannel Logout Handler (SLH) Detail Edit Report, 3390 |
SLH Detail Edit Report, Device Type FCTC | Subchannel Logout Handler (SLH) Detail Edit Report, FCTC |
SLH Detail Summary Report | Subchannel Logout Handler Summary Report |
SLH Detail Edit Report for zHPF | Subchannel Logout Handler (SLH) Detail Edit Report for zHPF |
SLH Detail Summary Report for zHPF | Subchannel Logout Handler Summary Report for zHPF |
DEVICE NUMBER: 01000 REPORT: SLH EDIT DAY YEAR JOB IDENTITY: CHNDRV
SCP: MVS/XA V2 R1 DATE: 260 04 C3C8D5C4D9E54040
DEVICE TYPE: 3390
CPU MODEL: 2084XA HH MM SS.TH
CHANNEL PATH ID: 12 LOGICAL CPU ID: 170044 TIME: 06 54 28.40
PHYSICAL CHAN ID: 0290 PHYSICAL CPU ADDRESS: 07 1
CC CA FL CT
FAILING CCW 31 C3605A 40 00 0005 VOLUME SERIAL 1D01D0
SUBCHANNEL ID NUMBER 00010018
K FLAGS CA US SS CT ERROR TYPE OTHER 2
SCSW 84 024017 0032F0F8 00 04 0000
---UNIT STATUS---- SUB-CHANNEL STATUS --------------------------SCSW FLAGS------------------------
FLAG 0 3 FLAG 1 FLAG 2
ATTENTION 0 PGM-CTLD IRPT 0 CCW FORMAT 0 RESERVED 0 SUBCHANNEL ACTIV 0
STATUS MODIFIER 0 INCORRECT LENGTH 0 PRE-FETCH CCW 0 SSCH FUNCTION 1 DEVICE ACTIVE 0
CONTROL UNIT END 0 PROGRAM CHECK 0 INIT STATUS 0 HSCH FUNCTION 0 SUSPENDED 0
BUSY 0 PROTECTION CHECK 0 ADDR LIMIT 0 CSCH FUNCTION 0 ALERT STATUS 1
CHANNEL END 0 CHAN DATA CHECK 0 SUPP SUSPEND INT 0 RESUME PENDING 0 INTERMED STATUS 0
DEVICE END 0 CHAN CTL CHECK 1 ZERO COND CODE 0 START PENDING 0 PRIMARY STATUS 1
UNIT CHECK 0 I/F CTL CHECK 0 EXTENDED CONTROL 1 HALT PENDING 0 SECONDARY STATUS 1
UNIT EXCEPTION 0 CHAINING CHECK 0 PATH NOT OPER 0 CLEAR PENDING 0 STATUS PENDING 1
----SOFTWARE RECOVERY STATUS-----
HARD FAIL 0
DEGRADE FAIL 0
SOFT FAIL 0
PASSED 0
CHANNEL ERROR ANALYSIS
IRB STORED BY INTERRUPT
TERMINATION BY -- SELECTIVE RESET -- CODE 2
SEQ CODE 2 - COMMAND ACCEPTED BY DEVICE BUT NO DATA TRANSFERRED
VALIDITY OF RECORDED DATA
COUNT INVALID
TERMINATION CODE VALID
SEQUENCE CODE VALID
DEVICE STATUS INVALID
CCW ADDRESS VALID
DEVICE NUMBER VALID
SENSE DATA NOT STORED
*MODEL-DEPENDENT DATA*
HARDWARE CHECKS-------(BYTE 0) MICROPROGRAM ERROR ID-(BYTE 1) LOG ID----------------(BYTE 2) PRESENT STATUS BYTE---(BYTE 3)
00 ** 01 25
REFER TO INCIDENT LOG 1
IO INTERFACE TIME OUT 0
MICROPROGRAM DETECT ERR 0
INVAL IO INTERF TAG SEQ 0
IO ALERT (DISCONN IN) 0
MULT IO INTERF IN TAGS 0
IO INTERF BUS IN PAR ERR 0
INJECTED ERROR 0
SERV OR DAT TAG DUR SHORT 0
SERVICE/DATA ACTIVE 0
OPERATIONAL IN FELL EARLY 0
CHANNEL TAG CONTROL 1-(BYTE 4) CHANNEL TAG CONTROL 2-(BYTE 5) I/O BUS IN------------(BYTE 6) UNIT ADDRESS----------(BYTE 7)
A0 C1 00 D0
OPERATIONAL OUT 1 OPERATIONAL IN 1
ADDRESS OUT 0 STATUS IN 1
SELECT OUT 1 SELECT IN 0
* BUS OUT TAG 0 ADDRESS IN 0
* SERVICE OUT 0 REQUEST IN 0
* DATA OUT 0 SERVICE OR DATA IN 0
SUPPRESS OUT 0 FIRST DATA 0
COMMAND OUT 0 COMMAND SENT 1
USTATS/CONFIG---------(BYTE 8) CUCW STATUS-----------(BYTE 9) CONFIGURATION BYTE 0-(BYTE 10) CONFIGURATION BYTE 1-(BYTE 11)
06 00 70 88
ENABLE SIM IO 0 RESERVED 0
ENABLE TIMEOUT CHECK 1 TYPE 1 CONTROL UNIT 0
ENABLE DEV TRACE 1 TYPE 2 CONTROL UNIT 1
INTERLOCK PROTOCOL 00 0 RESERVED 0
INTERLOCK PROTOCOL 01 0 DYNAMIC PATHING 0
STREAMING PROTOCOL 1 RESERVED 0
RESERVED 0 IOCP CONFIGURED 1
BYTE MULTIPLEX 0 RESERVED 0
RESERVED 0 RESERVED 0
RESERVED 0 RESERVED 0
PHYSICAL PATH--------(BYTE 12) ZERO-----------------(BYTE 13) ZERO-----------------(BYTE 14) ZERO-----------------(BYTE 15)
12 00 34 82
CHANNEL LOGOUT DATA
0000 00000000 00000002 00000000 00000000 00000002 00000000 00000000 00000000
0020 00000000 00000000 00000000 00000000 00000000 9000AB00 80000000 00000000
0040 00000000 00693713 00006942 10000800 88A0745E 10000800 88A0745E 50050764
0060 01006573 50050764 00C890CC 001A0047 00000000 00000000 0800009B 00000000
0080 22000022 00000000 02000000 18100020 50050769 00C414E7 00000000 00000000
00A0 00800100 30303231 30373030 3049424D 30303030 30303030 30303030 30300211
00C0 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00E0 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
CONTROL UNIT LOGOUT DATA
0000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0020 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0040 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0060 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0080 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00A0 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00C0 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00E0 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
HEX DUMP OF RECORD
HEADER 23831800 00030000 0004260F 10483163 000190CC 20848000
0018 C3C8C4C4 F3F14040 04200020 00FFF420 801F2024 00000000 00000000 04C24017
0038 00861A38 00020000 00406480 20000000 40000000 00000000 00000000 00000000
0058 00000000 00000000 00000000 00000000 00000000 00000001 00A000A8 02096808
0078 1003D4D4 F1F0F0F2 01000000 01010091 00018EAE 00000000 00000000 00000000
0098 800002A0 00000001 000000B8 02000100 00000000 00000000 00000000 00000000
00B8 00000000 00000002 00000000 00000000 00000002 00000000 00000000 00000000
00D8 00000000 00000000 00000000 00000000 0C000000 9000AB00 80000000 00000000
00F8 00000000 00693713 00006942 10000800 88A0745E 10000800 88A0745E 50050764
0118 01006573 50050764 00C890CC 001A0047 00000000 00000000 0800009B 00000000
0138 22000022 00000000 02000000 18100020 50050769 00C414E7 00000000 00000000
0158 00800100 30303231 30373030 3049424D 30303030 30303030 30303030 30300211
0178 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0198 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01B8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01D8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01F8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0218 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0238 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0258 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0278 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0298 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
DEVICE NUMBER: 00E26 REPORT: SLH EDIT DAY YEAR JOB IDENTITY: XCFAR
SCP: VS 2 REL. 3 DATE: 260 04 E7C3C6C1D9404040
DEVICE NED: 002105.000.IBM.075.000000012252.0615
DEVICE TYPE: FCTC
CPU MODEL: 2084XA HH MM SS.TH
CHANNEL PATH ID: A4 LOGICAL CPU ID: 1084XA TIME: 22 38 05.43
PHYSICAL CHAN ID: 0210 PHYSICAL CPU ADDRESS: 3A
CC CA FL CT
FAILING CCW E3 680000 00 00 0000 VOLUME SERIAL N/A
SUBCHANNEL ID NUMBER 00010B50
K FLAGS CA US SS CT ERROR TYPE OTHER
SCSW 0C 024017 5B791860 00 02 0000
---UNIT STATUS---- SUB-CHANNEL STATUS --------------------------SCSW FLAGS------------------------
FLAG 0 3 FLAG 1 FLAG 2
ATTENTION 0 PGM-CTLD IRPT 0 CCW FORMAT 0 RESERVED 0 SUBCHANNEL ACTIV 0
STATUS MODIFIER 0 INCORRECT LENGTH 0 PRE-FETCH CCW 0 SSCH FUNCTION 1 DEVICE ACTIVE 0
CONTROL UNIT END 0 PROGRAM CHECK 0 INIT STATUS 0 HSCH FUNCTION 0 SUSPENDED 0
BUSY 0 PROTECTION CHECK 0 ADDR LIMIT 0 CSCH FUNCTION 0 ALERT STATUS 1
CHANNEL END 0 CHAN DATA CHECK 0 SUPP SUSPEND INT 0 RESUME PENDING 0 INTERMED STATUS 0
DEVICE END 0 CHAN CTL CHECK 0 ZERO COND CODE 0 START PENDING 0 PRIMARY STATUS 1
UNIT CHECK 0 I/F CTL CHECK 1 EXTENDED CONTROL 1 HALT PENDING 0 SECONDARY STATUS 1
UNIT EXCEPTION 0 CHAINING CHECK 0 PATH NOT OPER 0 CLEAR PENDING 0 STATUS PENDING 1
----SOFTWARE RECOVERY STATUS-----
HARD FAIL 0
DEGRADE FAIL 0
SOFT FAIL 1
PASSED 0
CHANNEL ERROR ANALYSIS
IRB STORED BY INTERRUPT
TERMINATION BY -- SELECTIVE RESET -- CODE 2
SEQ CODE *** INVALID ***
VALIDITY OF RECORDED DATA
COUNT INVALID
TERMINATION CODE VALID
SEQUENCE CODE INVALID
DEVICE STATUS INVALID
CCW ADDRESS VALID
DEVICE NUMBER VALID
SENSE DATA NOT STORED
EXTENDED SUBCHANNEL LOGOUT DATA
CHANNEL LOGOUT DATA
N-PORT LINK ERROR STATUS BLOCK
LINK FAILURE COUNT: 00000000 LOSS OF SYNCHRONIZATION COUNT: 00000000 34
LOSS OF SIGNAL COUNT: 00049A8E PRIMITIVE SEG PROTOCOL ERROR: 0000001F 34
INVALID TRANSMISSION WORD: 0C000000 INVALID CRC COUNT: 9000AB00 34
FABRIC ENTRY PORT LINK ERROR STATUS
LINK FAILURE COUNT: 00000000 LOSS OF SYNCHRONIZATION COUNT: 0C200000 34
LOSS OF SIGNAL COUNT: 00049A8E PRIMITIVE SEG PROTOCOL ERROR: 00617B13 34
INVALID TRANSMISSION WORD: 0C000000 INVALID CRC COUNT: 10000800 34
ERROR CODE: 88 - Reserved: No Meaning
MODEL DEPENDENT DATA:
0000 88A08EFB 10000800 88A08EFB 50050764 01000758 50050764 00C1AA0A 00000001
0020 00000000 00000000 08000037 00004000 22000022 00000000 02000000 18100020
0040 50050764 01400758 50050764 00C1AA0A 102001A5 30303230 38344433 3249424D
0060 30323030 30303030 30314141 3041C0A5 00000000 00000000 00000000 00000000
0080 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00A0 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00C0 00000000 00000000 00000000 00000000
CONTROL UNIT LOGOUT DATA
N-PORT LINK ERROR STATUS BLOCK
LINK FAILURE COUNT: 00000000 LOSS OF SYNCHRONIZATION COUNT: 00000000 34
LOSS OF SIGNAL COUNT: 00000000 PRIMITIVE SEG PROTOCOL ERROR: 00000000 34
INVALID TRANSMISSION WORD: 00000000 INVALID CRC COUNT: 00000000 34
FABRIC ENTRY PORT LINK ERROR STATUS
LINK FAILURE COUNT: 00000000 LOSS OF SYNCHRONIZATION COUNT: 00000000 34
LOSS OF SIGNAL COUNT: 00000000 PRIMITIVE SEG PROTOCOL ERROR: 00000000 34
INVALID TRANSMISSION WORD: 00000000 INVALID CRC COUNT: 00000000 34
ERROR CODE: 00 - Error code transfer not supported
MODEL DEPENDENT DATA:
0000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0020 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0040 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0060 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0080 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00A0 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
00C0 00000000 00000000 00000000 00000000
HEX DUMP OF RECORD
HEADER 23831800 00030000 0006104F 22380543 0012AA0A 20848000
0018 E7C3C6C1 D9404040 E3680000 00000000 00004120 00000000 40806780 0C024017
0038 5B791860 00020000 00806480 20000000 80000000 00000000 00000000 00000000
0058 00000000 00000000 00000000 00000000 00000000 00000012 003A00A1 021907A8
0078 0E260000 00000000 01000000 010200A4 00010B50 00000000 00000000 00000000
0098 80000210 00000001 000000D8 02000100 00000201 00050101 01020202 04050102
00B8 F0F0F2F1 F0F5F1F1 F1F2F2F2 F4F5F1F2 F3F4F5F6 F7F1F9F8 F3F1F4F3 F2F10000
00D8 00000000 00000000 00049A8E 0000001F 0C000000 9000AB00 08000000 0C200000
00F8 00400000 00617B13 0000617A 10000800 88A08EFB 10000800 88A08EFB 50050764
0118 01000758 50050764 00C1AA0A 00000001 00000000 00000000 08000037 00004000
0138 22000022 00000000 02000000 18100020 50050764 01400758 50050764 00C1AA0A
0158 102001A5 30303230 38344433 3249424D 30323030 30303030 30314141 3041C0A5
0178 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0198 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01B8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01D8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01F8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0218 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0238 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0258 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0278 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0298 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
CHANNEL PATH ID: 12 REPORT: SLH SUMMARY REPORT DATE: 073 97
PERIOD FROM: 043 97
NUMBER OF RECORDS: 0001 CPU MODEL: 3090XA TO: 043 97
CPU ID : 170044
ERROR TYPE: STORAGE 0000
KEY 0000
OTHER 0001
----UNIT STATUS---- --SUB-CHANNEL STATUS--
ATTENTION 0000 PGM-CTLD IRPT 0000
STATUS MODIFIER 0000 INCORRECT LENGTH 0000
CONTROL UNIT END 0000 PROGRAM CHECK 0000
BUSY 0000 PROTECTION CHECK 0000
CHANNEL END 0000 CHAN DATA CHECK 0000
DEVICE END 0000 CHAN CTN CHECK 0001
UNIT CHECK 0000 I/F CTL CHECK 0000
UNIT EXCEPTION 0000 CHAINING CHECK 0000
-----SOFTWARE RECOVERY STATUS-----
HARD FAIL 0000
DEGRADE FAIL 0000
SOFT FAIL 0000
PASSED 0000
DEVICE NUMBER: 00E26 REPORT: SLH EDIT DAY YEAR JOB IDENTITY: XCFAS
SCP: MVS/XA V2 R3 DATE: 104 06 E7C3C6C1E2404040
DEVICE TYPE: FCTC
CPU MODEL: 2084XA HH MM SS.TH
CHANNEL PATH ID: A4 LOGICAL CPU ID: 12AA0A TIME: 22 38 05.43
PHYSICAL CHAN ID: 0210 PHYSICAL CPU ADDRESS: 3A
FAILING CCW N/A VOLUME SERIAL N/A
SUBCHANNEL ID NUMBER 00010B50
K FLAGS TA US SS FX ES ERROR TYPE OTHER
SCSW 0C 424017 5B791860 00 02 00 00
---UNIT STATUS---- SUB-CHANNEL STATUS --------------------------SCSW FLAGS------------------------
FLAG 0 FLAG 1 FLAG 2
ATTENTION 0 PGM-CTLD IRPT 0 IRB FORMAT 2 RESERVED 0 SUBCHANNEL ACTIV 0
STATUS MODIFIER 0 INCORRECT LENGTH 0 --- SSCH FUNCTION 1 DEVICE ACTIVE 0
CONTROL UNIT END 0 PROGRAM CHECK 0 --- HSCH FUNCTION 0 SUSPENDED 0
BUSY 0 PROTECTION CHECK 0 FORMAT CONTROL 0 CSCH FUNCTION 0 ALERT STATUS 1
CHANNEL END 0 CHAN DATA CHECK 0 INTERROGATE COMP 0 RESUME PENDING 0 INTERMED STATUS 0
DEVICE END 0 CHAN CTL CHECK 0 RESERVED 0 START PENDING 0 PRIMARY STATUS 1
UNIT CHECK 0 I/F CTL CHECK 1 EXTENDED CONTROL 1 HALT PENDING 0 SECONDARY STATUS 1
UNIT EXCEPTION 0 CHAINING CHECK 0 PATH NOT OPER 0 CLEAR PENDING 0 STATUS PENDING 1
----SOFTWARE RECOVERY STATUS-----
HARD FAIL 0
DEGRADE FAIL 0
SOFT FAIL 1
PASSED 0
CHANNEL ERROR ANALYSIS
IRB STORED BY INTERRUPT
TERMINATION BY -- SELECTIVE RESET -- CODE 2
SEQ CODE 2 *** INVALID ***
VALIDITY OF RECORDED DATA
COUNT INVALID
TERMINATION CODE VALID
SEQUENCE CODE INVALID
DEVICE STATUS INVALID
TCW ADDRESS VALID
DEVICE NUMBER VALID
SENSE DATA NOT STORED
EXTENDED SUBCHANNEL LOGOUT DATA
CHANNEL LOGOUT DATA
N-PORT LINK ERROR STATUS BLOCK
LINK FAILURE COUNT: 00000001 LOSS OF SYNCHRONIZATION COUNT: 00000002
LOSS OF SIGNAL COUNT: 00000000 PRIMITIVE SEG PROTOCOL ERROR: 00000000
INVALID TRANSMISSION WORD: 00000000 INVALID CRC COUNT: 00000000
FABRIC ENTRY PORT LINK ERROR STATUS
LINK FAILURE COUNT: 00000002 LOSS OF SYNCHRONIZATION COUNT: 00000000
LOSS OF SIGNAL COUNT: 00000000 PRIMITIVE SEG PROTOCOL ERROR: 00000000
INVALID TRANSMISSION WORD: 00049A8E INVALID CRC COUNT: 0000001F
ERROR CODE: 0C - Receive ABTS
MODEL DEPENDENT DATA:
0000 0C000000 9000AB00 08000000 0C200000 00400000 00617B13 000 0617A 10000800
0020 88A08EFB 10000800 88A08EFB 50050764 01000758 50050764 00C 1AA0A 00000001
0040 00000000 00000000 08000037 00004000 22000022 00000000 020 00000 18100020
0060 50050764 01400758 50050764 00C1AA0A 102001A5 30303230 383 44433 3249424D
0080 30323030 30303030 30314141 3041C0A5 00000000 00000000 000 00000 00000000
00A0 00000000 00000000 00000000 00000000 00000000 00000000 000 00000 00000000
00C0 00000000 00000000 00000000 00000000
CONTROL UNIT LOGOUT DATA
N-PORT LINK ERROR STATUS BLOCK
LINK FAILURE COUNT: 00000000 LOSS OF SYNCHRONIZATION COUNT: 00000000
LOSS OF SIGNAL COUNT: 00000000 PRIMITIVE SEG PROTOCOL ERROR: 00000000
INVALID TRANSMISSION WORD: 00000000 INVALID CRC COUNT: 00000000
FABRIC ENTRY PORT LINK ERROR STATUS
LINK FAILURE COUNT: 00000000 LOSS OF SYNCHRONIZATION COUNT: 00000000
LOSS OF SIGNAL COUNT: 00000000 PRIMITIVE SEG PROTOCOL ERROR: 00000000
INVALID TRANSMISSION WORD: 00000000 INVALID CRC COUNT: 00000000
ERROR CODE: 00 - Error code transfer not supported
MODEL DEPENDENT DATA:
0000 00000000 00000000 00000000 00000000 00000000 00000000 000 00000 00000000
0020 00000000 00000000 00000000 00000000 00000000 00000000 000 00000 00000000
0040 00000000 00000000 00000000 00000000 00000000 00000000 000 00000 00000000
0060 00000000 00000000 00000000 00000000 00000000 00000000 000 00000 00000000
0080 00000000 00000000 00000000 00000000 00000000 00000000 000 00000 00000000
00A0 00000000 00000000 00000000 00000000 00000000 00000000 000 00000 00000000
00C0 00000000 00000000 00000000 00000000
HEX DUMP OF RECORD
HEADER 23831800 00030000 0006104F 22380543 0012AA0A 20848000
0018 E7C3C6C1 E2404040 E3680000 00000000 00004120 00000000 40806780 0CC24017
0038 5B791860 00020000 00806480 20000000 80000000 00000000 00000000 00000000
0058 00000000 00000000 00000000 00000000 00000000 00000012 003A00A1 021907A8
0078 0E260000 00000000 01000000 010100A4 00010B50 00000000 000000000 00000000
0098 80000210 00000001 000000B8 02000100 00000000 00000000 00000000 00000000
00B8 00000001 00000002 00000000 00000000 00000000 00000000 00000002 00000000
00D8 00000000 00000000 00049A8E 0000001F 0C000000 9000AB00 08000000 0C200000
00F8 00400000 00617B13 0000617A 10000800 88A08EFB 10000800 88A08EFB 50050764
0118 01000758 50050764 00C1AA0A 00000001 00000000 00000000 08000037 00004000
0138 22000022 00000000 02000000 18100020 50050764 01400758 50050764 00C1AA0A
0158 102001A5 30303230 38344433 3249424D 30323030 30303030 30314141 3041C0A5
0178 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0198 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01B8 00000001 00000002 00000000 00000000 00000000 00000000 00000012 00000000
01D8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
01F8 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0218 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0238 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0258 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0278 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
0298 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
CHANNEL PATH ID: A4 REPORT: SLH SUMMARY REPORT DATE: 111 06
PERIOD FROM: 104 06
NUMBER OF RECORDS: 0001 CPU MODEL: 2084XA TO: 104 06
CPU ID : 12AA0A
ERROR TYPE: STORAGE 0000
KEY 0000
OTHER 0001
----UNIT STATUS---- --SUB-CHANNEL STATUS--
ATTENTION 0000 PGM-CTLD IRPT 0000
STATUS MODIFIER 0000 INCORRECT LENGTH 0000
CONTROL UNIT END 0000 PROGRAM CHECK 0000
BUSY 0000 PROTECTION CHECK 0000
CHANNEL END 0000 CHAN DATA CHECK 0000
DEVICE END 0000 CHAN CTN CHECK 0000
UNIT CHECK 0000 I/F CTL CHECK 0001
UNIT EXCEPTION 0000 CHAINING CHECK 0000
-----SOFTWARE RECOVERY STATUS-----
HARD FAIL 0000
DEGRADE FAIL 0000
SOFT FAIL 0001
PASSED 0000