Tells EREP to
Select for the requested
report only those records created while the system was operating in
the specified mode.
Syntax
MODE={370
| 370XA | ALL}
- 370
- means 370 mode only.
- 370/XA
- means 370XA and 370/ESA modes
only.
- ALL
- means 370, 370XA and 370/ESA modes.
Defaults
If
you omit this selection parameter, EREP assumes MODE=ALL and processes
all available records, regardless of the mode they were recorded in.
Coding
- ZERO=Y is valid only with MODE=ALL.
- If you code:
- MODE=370 and TYPE=C, EREP processes CCH records
- MODE=370XA and TYPE=C, EREP processes SLH and CRW records
- MODE=ALL and TYPE=C, EREP processes all available CCH, SLH, and
CRW records
Parameter Conflicts
None.
Notes
- If EREP is running under any MVS system except MVS/XA, it treats
software (SFT) records produced by MVS/XA as unknown records. Therefore,
the combination of MODE=370XA or MODE=ALL and TYPE=S is
meaningful only if the records were produced by MVS/XA.
- If a device is supported in 370XA mode,
any detail summary reports you request for the device reflect that
mode, regardless of what you specify on the MODE parameter.