Tells EREP to
Use only the records containing
the serial number and channel unit address specified.
Syntax
CPUCUA=(serial.{cua|cuX}[,serial.{cua|cuX}]…)
- serial
- The six-digit hexadecimal CPU serial number.
- cua
- A unique three- or four-digit hexadecimal channel or unit address
(the device number in a 370/XA environment).
- cuX
- Two or three hexadecimal digits followed by an X to
denote the range of device addresses with those digits ending in 0
through F.
Defaults
EREP processes
all available records.
Coding
Maximum of
four entries.
When using PR/SM to create logical partitions,
use the logical partition identifier in conjunction with the last
four digits of the serial number. See PR/SM Feature for
more information.
Parameter Conflicts
CPU
CUA
DEVSER
MOD
THRESHOLD
ZERO
Notes
- If you use the CPUCUA parameter, you cannot use ZERO=Y because
you have excluded some records from processing.
- CPUCUA only affects the selection of record types (TYPE parameter)
that contain a CUA: