Tells EREP to
Select for the threshold
summary only those OBR records that contain the specified device serial
numbers.
Syntax
DEVSER=(serial[,serial]…)
- serial
- A six-digit decimal device serial number from the service data.
Defaults
EREP
selects OBR records without regard for the device serial numbers they
contain.
Coding
Maximum
of eight entries.
DEVSER is used only for the threshold
summary report.
Parameter Conflicts
Parameters |
ACC |
EVENT |
PRINT |
SYSEXN |
TRENDS |
CPUCUA |
LIA/LIBADR |
SHORT |
SYSUM |
ZERO |
ERRORID |
MOD |
SYMCDE |
TERMN |
|
Notes
- EREP forces the DEV and TYPE parameters when you use the DEVSER
parameter. See Threshold Summary Report Information in Product-Dependent Information.
- The device serial number is a value in a 2-byte field of a tape
OBR record that corresponds to the external serial number of the device.
If the external serial number is greater than 65535, only the four
low-order digits (decimal) are correct for the device serial. To use
DEVSER to specify numbers larger than 65535, do the following:
- Convert the external serial number to binary
- Reconvert the low-order (rightmost) 16 bits to decimal
- Pad the resulting number with leading zeros to make a six-digit
decimal number.
Examples
DEVSER=(013455,113455,213455)