Processor (CPU) Subsystem Exception

The processor (CPU) subsystem exception report is organized by service level for:

TYPE DESCRIPTION
Termination errors The total number of incidents and the date and time of the last incident are shown for termination errors and hard errors.
Hard errors
Soft machine checks The total number of 60-minute intervals in which the number of events that occur equals or exceeds the LIMIT values is shown for soft machine checks. The LIMIT value is set by the LIMIT control statement, which sets the minimum number of errors (1–99). When the minimum has been reached, errors are recorded in the EXCEPTION COUNT column.
Figure 1 shows an example of the processor subsystem exception report.
Figure 1. Processor (CPU) Subsystem Exception Report
     1  

SUBSYSTEM EXCEPTION                       REPORT DATE 065 97
     PROCESSOR                            PERIOD FROM 041 97
                                                 TO   059 97
      2 
MODEL 3033   SERIAL 021595   CPU B


   TERMINATION ERROR     3                                 4           5 
SERVICE LEVEL INDICATOR                               TOTAL COUNT    DATE/TIME OF LAST ERROR

    POWER WARNING    . . . . . . . . . . . . . . . .          2      042/97   11:23:45:37
    INVALID LOGOUT   . . . . . . . . . . . . . . . .          2      042/97   23:24:35:87



      HARD ERROR
SERVICE LEVEL INDICATOR                               TOTAL COUNT    DATE/TIME OF LAST ERROR

    REGISTER/PSW INVALID           . . . . . . . . .          8      042/97   13:25:46:57
    HARD STORAGE ERROR             . . . . . . . . .          4      045/97   13:35:58:77
    SYSTEM DAMAGE                  . . . . . . . . .          2      049/97   14:34:34:87
    INSTRUCTION PROCESSOR DAMAGE   . . . . . . . . .          2      053/97   11:43:45:47
    STORAGE PROTECT KEY ERROR      . . . . . . . . .          2      057/97   11:23:45:37


                                         6 
  SOFT MACHINE CHECK               EXCEPTION COUNT
SERVICE LEVEL INDICATOR          60 MINUTE REFERENCE  TOTAL COUNT    DATE/TIME OF LAST ERROR

    EXTERNAL DAMAGE     . . . . . . .        2  . . .         4      044/97   13:35:58:77
    BUFFER ERROR        . . . . . . .        2  . . .         2      051/97   17:54:45:87
    HIR SUCCESSFUL      . . . . . . .        1  . . .         1      056/97   12:22:33:46



LIMITS APPLIED   EXTD=01,BUFE=01,HIRS=01   7 
    0 UNITS EXCLUDED DUE TO LIMITS

   20 MCH RECORDS PROCESSED
    1 MCH RECORDS UNDEFINED TO MCH ALGORITHMS   8 
 1 
This space is used for self-explanatory SCP and device-dependent messages specific to this subsystem exception report. For example:
** WARNING ** REPORT SPANS MORE THAN 3 DAYS
 2 
This report is provided for the following CPUs only:
  • 0158
  • 0168
  • 3031
  • 3032
  • 3033
 3 
The types of errors are:
  • TERMINATION ERROR
  • HARD ERROR
  • SOFT MACHINE CHECK
 4 
The count of input records containing this particular error.
 5 
Date and time of the last MCH record that includes this error. If the date and time are the same for several service level indicators, it means that a single record includes all the indicators.
 6 
The number of 60-minute intervals in which the number of events that occur equals or exceeds the LIMIT values for each type of soft machine check.
 7 
The LIMIT values applied to this report. If the LIMIT value is zero, the EXCEPTION COUNT field is also zero.
 8 
Execution-time notes. These may be:
NOTE DESCRIPTION
nn UNITS EXCLUDED DUE TO LIMITS If LIMIT values are present
nn MCH RECORDS PROCESSED Number of valid MCH records processed
nn MCH RECORDS UNDEFINED Not identifiable to EREP as valid MCH records
nn MCH RECORDS IGNORED DUE TO CCH DUPLICATION 0158 models only, from which MCH records might be double-reporting an assumed channel failure