IAR011I RSM COMPONENT TRACE EXTERNAL WRITER MAY HAVE LOST ENTRIES
Explanation
The operator started the real storage manager (RSM)
component trace and requested that the system write the trace entries
to a trace data set through the external writer. The system could
not write the trace entries to the data set for one of the following
reasons:
- The operator did not start the external writer before connecting the RSM component trace to the external writer.
- RSM reused the full trace buffer before the system could write the trace entries out to the trace data set. Some older trace entries have been lost.
System action
The system continues processing the RSM component trace.
System programmer response
Do one of the following:
- If you did not start the external writer, start it before connecting the RSM component trace to the external writer,
- Use IPCS to examine the trace entries that the system collected.
If the trace did not collect enough data to successfully diagnose
the problem, start the trace again and either:
- Use more trace buffers.
- Increase the size of the trace buffers.
Source
Real storage manager (RSM)
Module
IARQZ, IAXQZ
Routing code
1
Descriptor code
4