IEA958I EXCP APPENDAGE NAME TABLE NOT BUILT
Explanation
During system initialization, the nucleus initialization program (NIP) accessed the IEAAPP00 parmlib member to build a table of valid modules that can be loaded as run channel program (EXCP) appendages. Due to an I/O error or to a syntax error in IEAAPP00, NIP could not complete construction of this table.
If installation supplied modules are being loaded as appendages for a data control block (DCB) with MACRF=(E), the modules must operate in protection key 0-7 or be authorized under authorized program facility (APF).
System action
If unauthorized installation-supplied appendages are loaded for a DCB with MACRF=(E), the system issues abend code X'913'with a return code X'20'.
Operator response
Notify to the system programmer.
System programmer response
Rebuild IEAAPP00 prior to the next IPL for.
Source
DFSMSdfp
Module
IEAVNP16