IEA939D QUICK AND WARM START DATA IS INVALID, RE-IPL OR REPLY ‘GO’ FOR COLD START
Explanation
A system initialization without the CLPA option
was attempted. Information on the PLPA paging data set was inaccessible:
- The specified PLPA paging data set must be the same as that used on the previous successful cold start (CLPA IPL), and must not be *NONE*.
- If the same data set was being used, then the system could not read the necessary information.
System action
The system waits for the operator to reply.
Operator response
Either enter REPLY id,GO if a cold start is desired, or reIPL with a different data set specified for PLPA paging. Notify the system programmer.
System programmer response
Verify that the correct IEASYSxx parmlib member is being used. Also, verify the previous use of the PLPA paging data set.
Source
Auxiliary storage manager (ASM)
Module
ILRASRIM
Routing code
Note 9
Descriptor code
2